Records from 1985 to 1997. Most recent: inspection, 10 August 1997.
Inspection history · 29
10 August 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1117490
25 July 1996
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1088699
22 July 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 483256
14 February 1995
Hull Examination · Damage Survey · COI Inspection · Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 830211
30 January 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 29123
27 June 1994
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1137978
8 February 1994
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 852862
13 July 1993
COI Inspection · Hull Examination · Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1160184
16 September 1992
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 951272
7 July 1992
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1270363
16 June 1992
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 945914
5 June 1992
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 950001
22 May 1992
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 952352
2 February 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 113944
20 September 1991
Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1255465
28 August 1991
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 935753
6 July 1990
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1241976
12 March 1990
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1219642
22 January 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 913546
1 September 1989
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 895350
8 July 1988
COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1342506
27 June 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 540467
7 January 1988
Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1015247
19 October 1987
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1324465
16 December 1986
Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1004229
28 May 1986
COI Inspection · Credit Drydock
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 984975
3 December 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1293449
18 July 1985
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 982045
13 February 1985
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 976002
Documentation
Issued 28 August 1991
Resolved
THE VAPOR RECOVERY SYSTEM SHALL NOT BE USED FOR COLLECTION OF CARGO VAPORS_x001C_UNTIL PLANS HAVE BEEN APPROVED BY THE COAST GUARD MARINE SAFETY CENTER AND THE VESSEL'S CERTIFICATE OF INSPECTION HAS BEEN ENDORSED AUTHORIZING USE OFSAME._x001C_
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Deck/Cargo
Issued 22 January 1990
Resolved
PROVIDE COPY OF APPROVED PLANS FOR THE INSTALLED VAPOR RECOVERY SYSTEM, STRIPPING SYSTEM, GAUGING (SIGHT GLASSES) AND DEEP WELL PUMP TO [name withheld]
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Deck/Cargo
Issued 22 January 1990
Resolved
PROVIDE COPY OF CORRECTED PIPING DIAGRAM TO [name withheld].
Condition: Unknown
Due 22 January 1990
Resolved 22 January 1990
Unknown
Issued 28 May 1986
Resolved
THE VESSEL MUST BE BOARDED AND CHECKED FOR DAMAGE AND CARGO TANK INTEGRITY AT LEAST ONCE A WEEK BY AN OWNER'S REPRESENTATIVE PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Deck/Cargo
Issued 28 May 1986
Resolved
TEST THE CARGO HANDLING EQUIPMENT IN ACCORDANCE WITH 33CFR156.170 PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Deck/Cargo
Issued 28 May 1986
Resolved
INSTALL NEW GAUGE OR MAKE REPAIRS TO PRESSURE GAUGES IN HYDRAULIC CARGO PUMP SYSTEM IN ACCORDANCE WITH 46CFR56.07-10(G) PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Deck/Cargo
Issued 28 May 1986
Resolved
PROVIDE RECORD OF TEST OF SAFETY RELIEF VALVES IN HYDRAULIC CARGO PUMP SYSTEM IN ACCORDANCE WITH 46CFR151.04-5(G) PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Deck/Cargo
Issued 28 May 1986
Resolved
CLEAN OR REPAIR ALL PRESSURE-VACUUM VALVES IN ACCORDANCE WITH 46CFR31.10-15(B) PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Construction/Loadline
Issued 28 May 1986
Resolved
PRESENT VESSEL FOR DRYDOCKING IN ACCORDANCE WITH 46CFR31.10-20(A) PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986