Records from 1997 to 2025. Most recent: inspection, 17 November 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
17 November 2025
Administrative Inspection · COI Inspection · Hull Examination · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8249943
21 November 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8020578
6 June 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7929546
3 November 2022
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7580514
3 November 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7336910
8 October 2020
Administrative Inspection · Drydock Exam · DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7074246
26 November 2019
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6854185
16 October 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6547641
4 October 2017
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6281112
30 September 2016
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5995424
28 September 2015
COI Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5726650
16 October 2014
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5014309
20 January 2012
Hull Examination · Construction Oversight · Administrative Inspection · Deadweight Survey · Plan Review "T" Boat
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4230262
27 September 2011
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4154660
9 March 2010
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3693133
9 March 2010
Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 3694551
9 July 2009
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 3529320
29 September 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3334912
2 October 2007
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3072260
17 October 2006
Hull Examination · Simplified Stability Test · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2803497
20 June 2006
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2689551
13 July 2005
Annual Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2432084
11 February 2003
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1741280
6 November 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1423681
2 February 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1444298
19 November 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446733
25 November 1997
Initial Certification · Plan Review "T" Boat · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1433283
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2024
Resolved
46 CFR 183.380 (j)
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. MI observed that over current protection fuses were blade type. Vessel shall install cartridge type fuses. To the satisfaction of USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2024
Resolved 17 July 2024
Resolution: Fuses were replaced with UL rated cartridge type fuses.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2024
Resolved
46 CFR 183.200 (b)
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI observed exposed dead end wires under the console. Vessel shall enact permanent repairs to the satisfaction of USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2024
Resolved 17 July 2024
Resolution: Dead end wires were removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 June 2024
Resolved
46 CFR 182.410 (b)
Gauges to indicate engine revolutions per minute (RPM)
must be provided for all propulsion engines installed in the vessel. MI observed that engine RPM gauge was not operational. Vessel shall enact permanent repairs to the satisfaction of USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2024
Resolved 17 July 2024
Resolution: RPM gauge replaced. Operational test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 June 2024
Resolved
46 CFR 180.68 (b)
A vessel on a rivers route must carry three hand red flare distress signals and three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. MI observed that vessel was missing one distress signal. O/O replaced it on the spot.
Action required: 10 - Deficiency Rectified
Due 20 June 2024
Resolved 20 June 2024
Resolution: O/O replaced it on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2024
Resolved
46 CFR 180.71 (a)
An adult life jacket must be provided for each person carried on board a vessel. MI observed one adult life jacket that was not serviceable. O/O replaced it on the spot.
Action required: 10 - Deficiency Rectified
Due 20 June 2024
Resolved 20 June 2024
Resolution: O/O replaced it on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 June 2024
Resolved
Vessel must undergo an annual inspection as specified in paragraph (b)(1) of this section. Vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessels anniversary date was 03DEC2023, and vessel is past 3 months from said date.
Vessel shall not operate with passengers until an annual inspection has been completed. - 46 CFR 176.500(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2024
Resolution: Completed annual inspection.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 November 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
MI identified the fuel shutoff quick release was not labeled.
46 CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 29 November 2022
Resolution: O/O provided photograph via e-mail of labeled fuel shutoff quick release, deficiency rectified.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 November 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible.
MI identified that the vessel was missing charts for it's area of operation.
46 CFR 184.420(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 29 November 2022
Resolution: O/O provided photograph via e-mail of vessel chart, deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 December 2020
Resolved
Ring life buoy was deteriorated.
Action required: 10 - Deficiency Rectified
Due 3 December 2020
Resolved 3 December 2020
Resolution: Owner replaced with new buoy during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 December 2020
Resolved
All flares onboard vessel were expired.
Action required: 10 - Deficiency Rectified
Due 3 December 2020
Resolved 3 December 2020
Resolution: Owner replaced with new flares during inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 December 2020
Resolved
Required 40B:C portable fire extinguisher was passed servicing date.
Action required: 10 - Deficiency Rectified
Due 3 December 2020
Resolved 3 December 2020
Resolution: Owner had servicing company member attend vessel during inspection to service out of date extinguisher.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 October 2020
Resolved
46 CFR 176.404 - An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, equipment, and on a sailing vessel, rigging and sails.
O/O failed to renew vsl COI on 28SEP2020.
Action required: 10 - Deficiency Rectified
Due 22 October 2020
Resolved 3 December 2020
Resolution: Vessel completed COI inspection on 03Dec2020:
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 October 2020
Resolved
46 CFR 176.600 (c)(2) - A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every five years. Vessel did not conduct a scheduled dry dock prior to September 30, 2020.
Action required: 10 - Deficiency Rectified
Due 22 October 2020
Resolved 3 December 2020
Resolution: Vessel completed drydock exam on 03Dec2020:
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 16 October 2018
Resolved
Life jacket donning instructions placard missing. 46CFR185.516
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2018
Resolved 30 October 2018
Resolution: Donning instructions for life jackets were placed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 October 2018
Resolved
Ring life Buoy was not servicable. 46CFR180.70(a)
Action required: 10 - Deficiency Rectified
Due 16 October 2018
Resolved 16 October 2018
Resolution: A new Coast Guard approved ring life buoy was added to the vessel.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 October 2018
Resolved
No log book for drills conducted onboard. 46CFR185.520(f)
46CFR185.524(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2018
Resolved 30 October 2018
Resolution: Owner has created a log book containing drills completed by crew.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 October 2018
Resolved
First aid kit did not contain all required items. 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2018
Resolved 30 October 2018
Resolution: Coast Guard approved medical kit was added to the vessel.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 16 October 2017
Resolved
Missing Emergency Instructions
Due 23 October 2017
Resolved 16 October 2017
Resolution: Provided Emergency Instructions
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 16 October 2017
Resolved
Provide one additional B-I fire extinguisher.
Due 16 October 2017
Resolved 16 October 2017
Resolution: One additional fire extinguisher provided
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 30 September 2016
Resolved
Missing type II retro reflective tape IAW 46CFR185.604i.
Due 14 October 2016
Resolved 13 October 2016
Resolution: retro reflective tape was attached to the ring.
Documentation › Certificates/Documents › Stability Letter
Issued 27 September 2011
Resolved
Provide written acknowledgement of passenger reduction to 6 passengers. COI to expire on 01DEC2011 due to the implementation of AAWPP (185LBS) and vessel will only be permitted to carry 6 passengers. Return original COI to [name withheld] on 01DEC2011. 46 CFR 178.215(c)
Due 1 December 2011
Resolved 21 March 2012
Resolution: No longer required as vessel had new hulls constructed and COI reissued.
Stability › Water on Deck › General
Issued 31 May 2010
Resolved
PROVIDE FREEING PORTS AT DECK LEVEL AT EACH CORNER OF THE VESSEL (AT LEAST 3" HIGH X 5" WIDE).
Action required: 705 - Other - as specified
Due 30 June 2010
Resolved 10 March 2011
Electrical › Electrical Distribution System (emergency) › Metallic Enclosure/Frame
Issued 13 July 2005
Resolved
PROPERLY MOUNT BATTERY BOX.
Due 13 August 2005
Resolved 2 October 2007
Resolution: Battery box was mounted.
Stability › Incline Test › General
Issued 13 July 2005
Resolved
CONDUCT PONTOON STABILITY TEST IAW COAST GUARD PROCEDURES.
Due 13 August 2005
Resolved 20 September 2005
Construction/Loadline › Hull › Hull Plating
Issued 11 February 2003
Resolved
Replace missing drain plug from center pontoon prior to next trip.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 February 2003
Resolved 11 February 2003
Fire Fighting
Issued 19 November 1998
Resolved
PROVIDE THREE (3) 2 1/2 GALLON METAL BUCKETS LABLED "FIRE BUCKET"
Condition: Unknown
Due 20 November 1998
Resolved 12 March 1999
Electrical
Issued 19 November 1998
Resolved
BUNDLE AND SUPPORT WIRING UNDER CONTROL PANEL.
Condition: Unknown
Due 20 November 1998
Resolved 12 March 1999
Engineering
Issued 19 November 1998
Resolved
REPLACE EMERCENCY CUT-OFF VALVE.
Condition: Unknown
Due 20 November 1998
Resolved 12 March 1999
Fire Fighting
Issued 19 November 1998
Resolved
PROVIDE PROOF OF REINSPECTION OF ONE B-I AND ONE B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 20 November 1998
Resolved 12 March 1999
Lifesaving
Issued 25 November 1997
Resolved
PROVIDE 2 PORTABLE BATTERY OPERATED LIGHTS.
Condition: Unknown
Due 5 December 1997
Resolved 17 December 1997
Unknown
Issued 25 November 1997
Resolved
REMOUNT PADEYE FOR HAULING VSL OUT OF WATER TO A MORE SUBSTANTIAL BASE.
Condition: Unknown
Due 25 December 1997
Resolved 19 February 1998
Construction/Loadline
Issued 25 November 1997
Resolved
VESSEL RESTRICTED TO TWELVE (12) PASSENGERS PER 46 CFR 177.315 UNTIL ACCEPTANCE OF STRUCTURAL CALCULATIONS PROVIDED BY A PROFESSIONAL ENGINEER OR NAVAL ARCHITECT.
Condition: Unknown
Due 25 November 1997
Resolved 25 November 1997
Lifesaving
Issued 25 November 1997
Resolved
INSTALL RAILING WITH SPACES LESS THAN 4 INCHES APART.
Condition: Unknown
Due 5 December 1997
Resolved 17 December 1997
Navigation
Issued 25 November 1997
Resolved
REMOUNT HORN OUTSIDE OF CONTROL CONSOLE.
Condition: Unknown
Due 2 December 1997
Resolved 17 December 1997
Documentation
Issued 25 November 1997
Resolved
ADDRESS ALL INCORRECT PLAN REVIEW ITEMS AS IDENTIFIED BY USCG INSPECTOR ANDRESUBMITT PACKAGE FOR FINAL APPROVAL.
Condition: Unknown
Due 14 December 1997
Resolved 19 February 1998
Documentation
Issued 25 November 1997
Resolved
PROVIDE FCC STATION LICENSE.
Condition: Unknown
Due 25 December 1997
Resolved 18 December 1997
Documentation
Issued 25 November 1997
Resolved
PROVIDE RADIOTELPHONY CERTIFICATE.
Condition: Unknown
Due 25 December 1997
Resolved 18 December 1997
Engineering
Issued 25 November 1997
Resolved
INSTALL INDEPENDENT FUEL TANK ALONG W/SUBMITTING PLANS TO [name withheld]. YOUR VESSEL IS RESTRICTED TO 12 OR LESS TOTAL PERSONS UNTIL THISREQUIREMENT IS MET.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Navigation
Issued 25 November 1997
Resolved
REPAIR BROKEN ANCHOR LIGHT COVER.
Condition: Unknown
Due 2 December 1997
Resolved 17 December 1997
Documentation
Issued 25 November 1997
Resolved
PROVIDE PROOF OF USER FEE PAYMENT.
Condition: Unknown
Due 25 December 1997
Resolved 19 February 1998
Documentation
Issued 25 November 1997
Resolved
PROVIDE DRUG TESTING INFORMATION AND PROVE IN COMPLIANCE WITH DRUG TESTING PROCEDURES.
Condition: Unknown
Due 25 December 1997
Resolved 17 December 1997
Engineering
Issued 25 November 1997
Resolved
PROPERLY LABEL FUEL SHUTOFF VALVE ONCE INSTALLED AS PER NEW FUEL TANK INSTALLATION.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Lifesaving
Issued 25 November 1997
Resolved
INSTALL LIFEJACKET PLACARDS WITH DONNING INSTRUCTIONS.
Condition: Unknown
Due 2 December 1997
Resolved 19 February 1998
Fire Fighting
Issued 25 November 1997
Resolved
PROVIDE 3 FIRE BUCKETS AS PER SUBCHAPTER "T".
Condition: Unknown
Due 2 December 1997
Resolved 17 December 1997
Lifesaving
Issued 25 November 1997
Resolved
PROVIDE DISTRESS SIGNALS AS PER SUBCHAPTER "T"
Condition: Unknown
Due 2 December 1997
Resolved 17 December 1997
Construction/Loadline
Issued 25 November 1997
Resolved
CONDUCT A PROPER AIR TEST IN PRESENCE OF USCG INSPECTOR ON ALL 3 PONTOONS.
Condition: Unknown
Due 25 December 1997
Resolved 19 February 1998