MAURY USCG vessel records Sign in
← All vessels

AMERICAN VETERAN

AMERICAN VETERAN is a 1973 freight ship. The Coast Guard has recorded 45 inspections since 1985, most recently in December 1995, along with 47 deficiencies.

Records from 1985 to 1995. Most recent: inspection, 15 December 1995.

Built
1973
Last inspected
15 December 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7225714 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
366425000 (licence lapsed)
Maury page id
psix-46789

Inspections, by type

…with no type recorded25
Years with a record 9 calendar years (1985–1995)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it39493 - Dead Weight, Ton
26456 - Regulatory (Subpart C or D), Gross Ton
18706 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WEZTMMSI 366425000 · expired · compulsorily equipped · granted 16 January 1992, cancelled 16 January 1997
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

REID MCALLISTER Towing Vessel · MISLE 69407 · 3 May 1994 · activity 107599REID MCALLISTER Towing Vessel · MISLE 69407 · 3 May 1994 · activity 174204

Inspection history · 45

15 December 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 884027
6 April 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1150714
24 March 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1432894
11 November 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1172667
10 November 1994 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 492881
30 August 1994 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1177946
11 July 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 442779
10 July 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 140490
1 June 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 861135
31 May 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 367242
3 May 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 107599
3 May 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 174204
22 April 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 450139
15 March 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 507681
26 February 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 229128
9 February 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1162832
7 February 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 180013
5 February 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 478110
21 January 1994 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 854282
7 January 1994 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1162117
4 January 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 460343
4 November 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 162953
8 October 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 128803
25 April 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 125830
22 April 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431218
23 December 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 826678
21 November 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 66359
10 October 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 27116
6 October 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1255204
5 August 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 73046
4 August 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1256946
29 July 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 127320
20 July 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 442966
2 July 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 951107
25 January 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 958900
23 January 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 132643
18 December 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 948182
10 February 1989 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1341658
14 July 1987 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1016600
9 April 1987 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1327925
27 January 1987 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1322256
20 May 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1295236
2 April 1986 Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1293790
7 April 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1290641
26 February 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1285716

Deficiency record · 47

Electrical
Issued 21 January 1994 Resolved
REPACK DIESEL GEN SALT WATER COOLING PUMP.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Fire Fighting
Issued 21 January 1994 Resolved
TEST ALL FLEX LOOP IN CO2 ROOM. (REMAINDER NOT TESTED 12-93).
Condition: Unknown
Due 25 March 1994
Resolved 25 March 1994
Electrical
Issued 21 January 1994 Resolved
PROVIDE [name withheld] A COPY OF U.S.C.G APPROVED TEST PROCEDURE FOR BOILER/ENG RM AUTOMATION.
Condition: Unknown
Due 25 March 1994
Resolved 25 March 1994
Lifesaving
Issued 21 January 1994 Resolved
REPACK PORT OUTSIDE WATERTIGHT DOOR HYDRAULIC RAM AT FRAME.
Condition: Unknown
Due 25 March 1994
Resolved 25 March 1994
Documentation
Issued 21 January 1994 Resolved
PROVIDE [name withheld] A COPY OF ABS ENDORSED LOADLINE CERTIFICATE.
Condition: Unknown
Due 25 March 1994
Resolved 25 March 1994
Fire Fighting
Issued 21 January 1994 Resolved
TEST ALL SMOKE DETECTORS FOR CARGO HOLDS.
Condition: Unknown
Due 25 March 1994
Resolved 25 March 1994
Engineering
Issued 2 July 1992 Resolved
CONDUCT TEST OD DC HEATER RELIEF VALVE.
Condition: Unknown
Due 2 July 1992
Resolved 2 July 1992
Deck/Cargo
Issued 2 July 1992 Resolved
TEST AND PROVE PROPER OPERATION OF BOW PORT/STBD, AFT PORT/STBD AND MID- SHIP PORT CONSTANT TENSION WINCHES
Condition: Unknown
Due 2 July 1992
Resolved 2 July 1992
Construction/Loadline
Issued 2 July 1992 Resolved
PROVE INTERGRITY OF ENGINEER'S CARGO HATCH MID-SHIP STBD SIDE.
Condition: Unknown
Due 2 July 1992
Resolved 2 July 1992
Lifesaving
Issued 2 July 1992 Resolved
RELOCATE WELDING MACHINE AND/OR GROUND CONNECTION FROM OVER TOP OF DIESEL OIL TAMK IN MACHINE SHOP TO A SPACE OTHER THAN OVER DIESEL OIL TANK.
Condition: Unknown
Due 2 July 1992
Resolved 2 July 1992
Deck/Cargo
Issued 18 December 1991 Resolved
TEST AIR RECEIVER RELIEF VALVES ON D/C HEATER, H/W HEATER, P/W TANK.
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Electrical
Issued 18 December 1991 Resolved
PROVIDE AND INSTALL PERMANENT PLAQUES ON BREAKER BOXES IN TUNNELS INDICATING THAT LIGHT BREAKERS FOR CARGO HOLDS HAVE BEEN DISCONNECTED AND INDICATE BREAKER NUMBERS.
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Deck/Cargo
Issued 18 December 1991 Resolved
TEST AND PROVE OPERATION OF ALL CONSTANT TENSION WINCHES. VESSEL IS REQUIRED TO CARRY THREE EXTRA ORDINARY SEAMEN UNTIL ITEM IS COMPLETED.
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Lifesaving
Issued 18 December 1991 Resolved
PROVE OPERATION OF SSRG LOW LEVEL ALARM.
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Accommodation/Occupational Safety
Issued 18 December 1991 Resolved
PROVE OPERATION OF A/C UNIT.
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Engineering
Issued 18 December 1991 Resolved
TEST OPERATION OF RELIEVING GEAR ON BOILERS.
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Lifesaving
Issued 18 December 1991 Resolved
SEAL WIREWAY THROUGH DECK BEHIND LADDER NEXT TO TANK IN THE EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Lifesaving
Issued 18 December 1991 Resolved
SEAL HOLE ABOVE WTD TO EMERGENCY GENERATOR SPACE AND STENCIL DOOR TO READ "KEEP CLOSED AT ALL TIMES."
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Electrical
Issued 18 December 1991 Resolved
PLACE BLANKS OVER OPENINGS IN POWER PANEL 2-100-2 BOTTOM OF LADDER PORT STACK ACROSS FROM ENGINEROOM ENTRANCE.
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Lifesaving
Issued 9 April 1987 Resolved
RENEW LIFEBOAT FALLS PORT AND STARBOARD LIFEBOATS.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Lifesaving
Issued 9 April 1987 Resolved
REPLACE ALL RINGBUOYS. CURRENT RING BUOYS UNSAT DUE TO ROTTED LINES.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Lifesaving
Issued 9 April 1987 Resolved
RENEW EXPIRED PARACHUTE FLARES IN PORT AND STBD LIFEBOATS.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Lifesaving
Issued 9 April 1987 Resolved
REPLACE ALL OUTDATED WATERLIGHT BATTERIES WITH AN APPROVED TYPE.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Lifesaving
Issued 9 April 1987 Resolved
PROVIDE (1) MISSING EXPOSURE SUIT, FITTED WITH STANDARD REQUIRED EQUIPMENT,AND STENCILED WITH NAME OF VESSEL.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Fire Fighting
Issued 9 April 1987 Resolved
CONDUCT ANNUAL SERVICING OF ALL FIXED, SEMI-PORTABLE, AND PORTABLE FIRE EX-TINGUISHING EQUIPMENT. PROVIDE [name withheld] WITH COPY OF SERVICING CERTIFICATES.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Lifesaving
Issued 9 April 1987 Resolved
PROVIDE APPROVED MARINE- TYPE RUDDER AS ORIGINAL FOR STBD LIFEBOAT. ADVISE [name withheld] IN WRITING UPON INSTALLATION. PROVIDE DOCUMEN- TATION.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Electrical
Issued 9 April 1987 Resolved
REPLACE THE GOVERNOR SERVO MOTOR IN THE 'ALCO' AUXILIARY DIESEL GENERATOR.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Lifesaving
Issued 9 April 1987 Resolved
PROVIDE DATED BATTERIES FOR LIFEBOAT FLASHLIGHTS.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Fire Fighting
Issued 9 April 1987 Resolved
CONDUCT ANNUAL SERVICING AND TESTING OF SMOKE DETECTION SYSTEM. ENSURE NO FAULTS IN SYSTEM, SENSORS OPERATE PROPERLY, BRIDGE REPEATER AGREES WITH MAIN CABINET IN CO2 ROOM.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Accommodation/Occupational Safety
Issued 9 April 1987 Resolved
MAKE PERMANENT REPAIRS TO BARGE WASHDOWN PUMP SO AS TO DISCONNEDT DEHUMIDI-FICATION SYSTEM FROM FIREMAIN PERMANENTLY. ADVISE [name withheld] IN WRITING UPON COMPLETION.
Condition: Unknown
Due 9 April 1987
Resolved 9 April 1987
Unknown
Issued 2 April 1986 Resolved
FRESH AND TROPICAL MARKS ON PORT AND STBD LOADLINE MARKS DO NOT COINCIDE WITH THE ABS ISSUED LOADLINE CERTIFICATE OF 13 JULY 1984. CONTACT ABS AND CORRECT. NOTIFY COGNIZANT U.S. COAST GUARD OCMI OF ACTION TAKEN.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
PROVIDE NO. 1 AND NO. 2 PROT AND STARBOARD TANKS, SPACE EDUCTORS AND ASSOCIATED PIPING FOR INSPECTION PRIOR TO CARRYING LIQUID CARGO IN BULK.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
PREPARE ALL BALLAST TANKS, FOREPEAK, FLUME TANKS AND VOIDS FOR INTERNAL INSPECTION.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
RENEW THE RUBBER EXPANSION JOINTS FOR THE BOILER MAIN CONDENSER SUCTION AND DISCHARGE LINES.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
HOSE TEST ALL CARGO HOLD HATCH COVERS.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
PROVIDE PORT & STBD INTERNATIONAL SHORE CONNECTION FACILITY, SUITABLE CHECKAND CUTOFF VALVES.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
RETEST ADDRESS AND TALKBACK SYSTEM ON FORECASTLE, BRIDGE WINGS AND GANGWAY.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
FIRE CONTROL PLANS TO BE SUBMITTED TO [name withheld] AND APPROVAL. APPROVED PLANS TO BE POSTED.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
NO OIL TRANSFER PROCEDURES CURRENTLY ONBOARD VESSEL. SUBMIT FOR APPROVAL TO [name withheld], HAWAII.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
SAREX OILY WATER SEPERATOR RECIRCULATING PIPING TO HOLDING TANK TO BE HARD PIPED AND PROPERLY SUPPORTED.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
MAINTAIN OIL RECORD BOOK, AND PROVIDE COPY TO COGNIZANT U. S. COAST GUARD OCMI.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
PROVIDE NEW GASKETS ON WATERTIGHT CLOSURES AS REQUIRED.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
REPAIR OR RENEW COVERS FOR CO2 FIXED SYSTEM PULL BOXES ON AFT BULKHEAD OF PORT STACKHOUSE ON MAIN DECK.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
RENEW HYDROSTATIC RELEASES FOR BOTH (2) LIFERAFT STATIONS.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
REPAIR OR RENEW THE APPROXIMATELY TWENTY (20) FIRE DAMPERS/CLOSURES LOCATEDON OPEN DECK AREAS WHICH ARE INOPERATIVE OR MISSING.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Unknown
Issued 2 April 1986 Resolved
MEANS OF STORING EXPOSURE SUIT AT BOW LOOKOUT STATION.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Fire Fighting
Issued 7 April 1985 Resolved
INSTALL A CLASS "A" BOUNDARY AND SELF CLOSING DOOR IN WAY OF STAIRWAY CONNECTING THE EMERGENCY GENERATOR ROOM AND SPACE BELOW IT.
Condition: Unknown
Due 7 April 1985
Resolved 7 April 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.