Records from 1982 to 1999. Most recent: inspection, 9 March 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
9 March 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 802388
24 April 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1402445
19 March 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1457330
29 February 1996
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1394477
19 July 1994
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1467418
16 November 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141359
14 October 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459827
23 March 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 836314
21 January 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 830526
30 July 1992
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 960934
11 July 1991
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 937171
11 September 1990
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 913715
21 September 1989
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333659
13 December 1988
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1210742
21 October 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1200534
21 June 1988
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 892008
10 September 1987
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007591
24 July 1986
Re-Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296516
18 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977990
8 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972724
22 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964934
14 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970232
Engineering
Issued 29 February 1996
Resolved
Remove flexible hose on F/O return line and renew with approved material onstarboard engine.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Engineering
Issued 29 February 1996
Resolved
Renew flexible hoses on water and hydraulic systems as needed.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Engineering
Issued 29 February 1996
Resolved
Remove petcocks and plug F/O filter drains on generator and stbd main eng.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Electrical
Issued 29 February 1996
Resolved
Install globe and guard on light in engine room.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Electrical
Issued 14 October 1993
Resolved
PLACE GUARD AROUND ALL ROTATING MACHINARY ON GENERATOR.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Engineering
Issued 14 October 1993
Resolved
REPLACE FLAME SCREEN ON FUEL TANK VENT.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Construction/Loadline
Issued 30 July 1992
Resolved
PROVIDE PROOF OF STABILITY, OR DOCUMENTATION SHOWING EVIDENCE OF THE TOTAL NUMBER OF PEOPLE CARRIED FOR DETERMINING SATISFACTORY STABILITY IN SERVICE,OR CONDUCT A SATISFACTORY SIMPLIFIED STABILITY TEST IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR IAW 46 CFR 170.120(b) AND 46 CFR 170.160(b).
Condition: Unknown
Due 30 July 1992
Resolved 30 July 1992