Records from 1982 to 1999. Most recent: inspection, 9 September 1999.
Inspection history · 81
9 September 1999
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 784399
16 August 1999
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1113021
6 August 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 795704
3 August 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 72427
16 June 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1364757
21 May 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 791946
7 April 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 164495
7 April 1998
Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1122707
10 October 1997
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1418249
29 August 1997
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 35697
9 July 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 716565
28 June 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 212739
18 June 1997
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 775973
17 June 1997
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 775617
1 May 1997
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 524219
9 January 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1098009
17 December 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1418066
13 August 1996
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1367884
30 January 1996
Type not recorded
No type recorded · Commandant (CG-INV) · Activity 229220
10 December 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 515993
8 November 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 88950
7 November 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 87548
2 November 1995
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1185090
2 November 1995
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1437024
5 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 65307
28 April 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 377903
11 March 1995
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1387719
6 February 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 11231
3 February 1995
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1367293
3 February 1995
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1454148
25 January 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 132048
25 January 1995
Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1142289
19 December 1994
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 841355
15 October 1994
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 476086
24 May 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 860045
15 March 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444820
11 March 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1415952
27 January 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 364044
24 May 1993
Hull Examination · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1152176
31 March 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1144259
25 March 1993
Examination of Repairs
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1149333
18 February 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 491773
6 February 1993
Examination of Repairs
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1362726
14 November 1992
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1135240
12 November 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 354398
1 September 1992
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 492168
20 July 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 496326
21 March 1992
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1260047
28 September 1991
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 473989
30 April 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 908040
5 April 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 924369
6 March 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 922226
5 December 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 491898
15 August 1990
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 919797
2 April 1990
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1231178
4 January 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 928217
19 July 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 521766
5 May 1989
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1044158
10 March 1989
Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 891341
11 November 1988
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 536125
14 September 1988
Damage Survey · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1351441
25 July 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 443162
16 April 1988
Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1338881
24 February 1988
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 446424
21 December 1987
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1006876
5 August 1987
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1337171
24 July 1987
Drydock Extension · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1311045
3 June 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1334994
4 March 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 443216
4 December 1986
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1022340
28 November 1986
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1326709
9 November 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 312572
3 October 1986
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1016572
26 September 1986
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1317825
10 September 1986
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1320209
20 March 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 509042
3 August 1985
Credit Drydock · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1302496
2 May 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1289166
7 November 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 440854
13 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965650
13 April 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1273471
Deck/Cargo
Issued 16 June 1998
Resolved
#3 STBD CARGO TANK - FRACTURED SIDE LONGITUDINAL IWO FORWARD STBD VERTICAL AND THE THIRD TRANSVERSE SHELF.
Condition: Unknown
Due 19 June 1998
Resolved 24 June 1998
Deck/Cargo
Issued 16 June 1998
Resolved
#3 PORT CARGO TANK - FRACTURED SIDE LONGITUDINAL IWO FORWARD PORT VERTICAL AND THE FIRST TRANSVERSE SHELF.
Condition: Unknown
Due 19 June 1998
Resolved 24 June 1998
Deck/Cargo
Issued 7 April 1998
Resolved
LEAK ON NUMBER 1 CARGO LINE MIDSHIPS. LINE IS PATCHED AND TO REMAIN ISOLATED UNTIL REPAIRED NLT 01MAY98.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Construction/Loadline
Issued 10 October 1997
Resolved
REMOVE OF PERMANENTLY INSTALL TELEVISIN ANTENNAS ON MAIN DECK SUPERSTRUCTURE.
Condition: Unknown
Due 23 October 1997
Resolved 23 October 1997
Fire Fighting
Issued 10 October 1997
Resolved
PROVIDE FOAM ANALYSIS REPORT
Condition: Unknown
Due 17 October 1997
Resolved 17 October 1997
Deck/Cargo
Issued 10 October 1997
Resolved
REPLACE FASTENINGS ON FLANGE OF WATER SUPPLY LINE TO DECK WATER SEAL OF IGS
Condition: Unknown
Due 23 October 1997
Resolved 23 October 1997
Engineering
Issued 10 October 1997
Resolved
DC HEATER TO BE INTERNALLY INSPECTED AT NEXT DRYDOCK.
Condition: Unknown
Due 10 October 1997
Resolved 10 October 1997
Deck/Cargo
Issued 10 October 1997
Resolved
REPLACE FASTENINGS ON STEAM HEATING MANIFOLDS ON THE CARGO DECK
Condition: Unknown
Due 23 October 1997
Resolved 23 October 1997
Fire Fighting
Issued 17 December 1996
Resolved
STEAM FIRE PUMP PACKING GLAND IS LEAKING PROFUSELY.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Navigation
Issued 17 December 1996
Resolved
RUDDER ANGLE INDICATOR BUSHING IS WORN. INDICATOR SHAFT IS SLOPPY.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Accommodation/Occupational Safety
Issued 17 December 1996
Resolved
REPAIR OR REPLACE INOPERATIVE GENERAL ALARM BELL LOCATED IN THE FOSCLE ELECTRICAL CAGE. PROVE PROPER OPERATION IN THE PRESENCE OF CG MARINE INSPECTOR.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 2 November 1995
Resolved
1 GENERAL ALARM BELL IN E/R NOT WORKING, 1 WEAK.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Construction/Loadline
Issued 2 November 1995
Resolved
AFT PEAK TANK HAS SEVERAL SWASH BULKHEADS WASTED.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Lifesaving
Issued 2 November 1995
Resolved
LIFE BOAT WINCH BRAKE HANDLE BROKE OFF WHEN LIFTED, STBD SIDE.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Electrical
Issued 2 November 1995
Resolved
DEAD WIRES LOCATED IN BACK OF POWER PANEL AT E/R CONTROL STATION. CAP, REMOVE OR REPLACE MISSING COMPONENT.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Lifesaving
Issued 2 November 1995
Resolved
BRAKE PAD AND BAND ON STBD LIFE BOAT WINCH BURNED OFF WHILE LOWERING BOAT AT WEIGHT TEST. FAILED AFTER THIRD STOPPING OF BOAT.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Engineering
Issued 2 November 1995
Resolved
FLAME SCREENS IN F/O VENTS AND COFFFERDAMS CORRODED OR IN NEED OF REPLACEMENT.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Accommodation/Occupational Safety
Issued 2 November 1995
Resolved
EMERGENCY STATION BILL AND LIFE BOAT ASSIGNMENT INSTRUCTIONS MISSING FROM INDIVIDUAL CREW QUARTERS.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Construction/Loadline
Issued 2 November 1995
Resolved
HULL INSET AT FR 78-81 CARGO TANK #3 PORT. TO BE REPAIRED WITH 10'X30' INSERT ALONG WITH 3 LONGS.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Lifesaving
Issued 2 November 1995
Resolved
LIFE BOAT EMBARKATION LADDER PORT SIDE HAS CHAIN LINKS APRROX 50% WASTED WHERE LADDER CONNECTS TO VSL.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Navigation
Issued 2 November 1995
Resolved
PORT STEERING GEAR MOTOR FAILED AT STEERING TEST JUST PRIOR TO DEPARTING.
Condition: Unknown
Due 3 November 1995
Resolved 3 November 1995
Deck/Cargo
Issued 2 November 1995
Resolved
INDICATOR LIGHTS AT LOCAL TEST LOCATION OF TANK OVERFLOW ALARM EXTINGUISHED. AUDIBLE ALARM AND MAIN INDICATOR LIGHT WORKING.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Electrical
Issued 2 November 1995
Resolved
SOME LAMPS EXTINGUISHED AND SOME EMER MARKINGS NOT ADEQUATE, ie PAINTED OVER.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Fire Fighting
Issued 2 November 1995
Resolved
3 1&1/2 INCH HOSES CONDEMED AT TIME OF HYDRO.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Deck/Cargo
Issued 2 November 1995
Resolved
SEVERAL FRACTURES NOTED BY ABS WHILE RAFTING CARGO TANKS. TO BE ADDRESSED IN YARD REPAIR PLAN.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Lifesaving
Issued 2 November 1995
Resolved
MANILA LINE USE FOR "MONKEY LINES" ROTTED AT TOP OF THIMBLE WHERE SPLICED AND CONNECTED TO SPAN WIRE.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Electrical
Issued 2 November 1995
Resolved
SEVERAL LAMPS IN EMER LIGHTING ON DECK EXTINGUISHED.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Lifesaving
Issued 3 February 1995
Resolved
CONDUCT SATISFACTORY WEIGHT TEST OF PORT LIFEBOAT
Condition: Unknown
Due 3 February 1995
Resolved 3 February 1995
Deck/Cargo
Issued 11 March 1994
Resolved
Complete repairs to anchor windlass and prove operation in presence of Coast Guard inspector.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Engineering
Issued 11 March 1994
Resolved
Complete port and stbd main propulsion boiler waterside and fireside examinations in presence of Coast Guard inspector.
Condition: Unknown
Due 11 April 1994
Resolved 24 May 1994
Deck/Cargo
Issued 25 March 1993
Resolved
REPAIR AND PROVE PROPER OPERATION OF ANCHOR WINLASS TO SATISFACTION OF ATTENDING MARINE INSPECTOR PRIOR TO DEPARTURE FROM NEXT PORT CALL (LONG BEACH, CALIFORNIA) OR NO LATER THAN 2 APRIL 1993.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Construction/Loadline
Issued 14 November 1992
Resolved
MAKE PERMANENT REPAIRS IN THE AFT CENTERLINE SLOP TANK TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 November 1992
Resolved 14 November 1992
Engineering
Issued 21 March 1992
Resolved
OPEN AND PRESENT FOR COAST GUARD INTERNAL EXAM THE DC HEATER.
Condition: Unknown
Due 21 March 1992
Resolved 21 March 1992
Engineering
Issued 21 March 1992
Resolved
OPEN AND PRESENT FOR COAST GUARD EXAM BOTH MAIN PROPULSION BOILER, FIRESIDEAND WATERSIDE, AND MOUNTS AND CONDUCT SATISFACTORY HYDROSTATIC TEST OF BOTHBOILERS.
Condition: Unknown
Due 21 March 1992
Resolved 21 March 1992
Construction/Loadline
Issued 4 January 1990
Resolved
MAKE PERMANENT REPAIRS TO DAMAGED AREA IN WAY OF #1 STBD CARGO TANK AT FWD FAIRLEAD TO THE SATISFACTION OF THE COGNIZANT OCMI AT VESSEL'S NEXT DRYDOCK AVAILIBILITY BUT NO LATER THAN 16 OCT 90.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Construction/Loadline
Issued 14 September 1988
Resolved
MAKE PERMANENT REPAIRS TO THE LEAK IN #55 CARGO TANK. DO NOT LOAD THIS TANKUNTIL REPAIRS ARE MADE.
Condition: Unknown
Due 14 September 1988
Resolved 14 September 1988
Engineering
Issued 24 July 1987
Resolved
PERFORM A 1.5 MAWP HYDROSTATIC TEST AND A WATERSIDE EXAM ON BOTH BOILERS.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Engineering
Issued 24 July 1987
Resolved
PERFORM AN INTERNAL EXAM OR A HYDROSTATIC TEST OF THE DC HEATER.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Fire Fighting
Issued 10 September 1986
Resolved
CREATE AND STOCK A SECOND EMERGENCY GEAR LOCKER AND CORRECT FIRE CONTROL PLAN TO REFLECT BOTH EMERGENCY GEAR LOCKERS.
Condition: Unknown
Due 10 September 1986
Resolved 10 September 1986
Navigation
Issued 10 September 1986
Resolved
REPLACE BURNT OUT BULBS IN NOT UNDER COMMAND LIGHTS.
Condition: Unknown
Due 10 September 1986
Resolved 10 September 1986
Fire Fighting
Issued 10 September 1986
Resolved
PROVIDE COPY OF CURRENT FOAM ANALYSIS.
Condition: Unknown
Due 10 September 1986
Resolved 10 September 1986
Engineering
Issued 10 September 1986
Resolved
MAKE PERMANENT REPAIRS TO STBD FORCE DRAFT BLOWER HIGH SPEED. REPAIRS TO BEMADE TO THE SATISFACTION OF THE COGNIZANT OCMI AT NEXT PORT.
Condition: Unknown
Due 10 September 1986
Resolved 10 September 1986
Engineering
Issued 10 September 1986
Resolved
PERFORM PORT BOILER AUTOMATION TO THE SATISFACTION OF THE COGNIZANT OCMI AT NEXT PORT.
Condition: Unknown
Due 10 September 1986
Resolved 10 September 1986
Unknown
Issued 10 September 1986
Resolved
MAKE PERMANENT REPAIRS TO THE OILY WATER SEPERATOR. REPAIRS AND TEST ARE TOBE TO THE SATISFACTION OF THE COGNIZANT [name withheld] 20 DAYS.
Condition: Unknown
Due 10 September 1986
Resolved 10 September 1986
Electrical
Issued 13 August 1982
Resolved
REPAIR OR REPLACE 250 AMP CIRCUIT BREAKER TO ENGINEROOM VENTILATION FANS.
Condition: Unknown
Due 13 August 1982
Resolved 13 August 1982