MAURY USCG vessel records
← All vessels

DS45

Built
1971
Last inspected
6 July 2018
Controls
None recorded without a removal date
Also recorded as
MSRC 451 (2004)

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 6 July 2018
…with no type recorded16
Operational controls None recorded without a removal date
Years with a record 31 calendar years (1984–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
2449 - Convention (Subpart B), Net Ton 2707 - Convention (Subpart B), Gross Ton
Maury page id
psix-46820
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

RACHEL Towing Vessel · MISLE 144426 · 7 April 2004 · activity 2044801

Inspection history · 84

6 July 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6469695
28 October 2016 Administrative Inspection · Plan Review (Other than "T")
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6031408
19 October 2016 Periodic Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6026038
13 January 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5819755
18 August 2015 Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5220177
4 February 2015 Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5064146
14 January 2015 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5053425
16 October 2013 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4735606
25 July 2013 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4665551
15 November 2012 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4500948
14 November 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4483889
1 December 2011 MTSA Verification · Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4200108
10 November 2011 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4186811
16 November 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3892292
18 August 2010 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3827814
10 May 2010 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3735478
23 October 2008 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3349998
21 August 2008 Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3291709
6 September 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3050911
21 August 2006 COI Inspection · MARPOL Annex I Examination · MTSA Verification · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2709328
15 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2649609
26 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2574094
3 November 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2527930
3 October 2005 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2507007
29 August 2005 Internal Structural Exam · Annual Inspection · Underwater Inspection in lieu of Drydock
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2415703
9 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2352937
2 March 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2302476
15 November 2004 MTSA Verification · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2221786
12 August 2004 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2150736
8 April 2004 In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2039271
7 April 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2044801
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1980901
26 November 2003 Deficiency Check · Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1955097
13 August 2003 Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1874883
29 July 2003 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1860755
26 August 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1666637
22 August 2001 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1443240
4 December 2000 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 824618
12 October 2000 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1057256
25 August 2000 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1451599
20 September 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 785171
27 August 1999 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1386585
16 December 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 813129
28 October 1998 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 804382
13 October 1998 Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1471842
11 August 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1395004
4 April 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788567
5 September 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 778426
27 August 1997 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 778627
27 September 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1392537
8 December 1995 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1187851
15 November 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 765372
10 November 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 206319
29 September 1995 Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1432962
7 June 1994 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1174108
3 May 1994 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 847505
2 October 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1250561
14 September 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 948138
13 August 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 352586
12 December 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 467405
13 September 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249727
4 April 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 478960
28 September 1990 Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1227196
21 September 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907879
22 February 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 461678
21 July 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1197015
15 March 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 445913
10 December 1988 Hull Examination · Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 897692
8 September 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1042247
1 July 1988 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1212003
2 June 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 897378
2 March 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 449658
22 July 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024478
22 July 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332401
10 April 1987 Damage Survey · Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1022732
1 December 1986 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1026819
19 June 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 985122
5 May 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 515582
26 July 1985 COI Inspection · Credit Drydock
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 983719
11 May 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 519663
7 February 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 975359
2 February 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1283203
9 January 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 455086
19 December 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 499670

Deficiency record · 53

Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 25 July 2013 Resolved
Provide USCG MSC approved plans to the OCMI prior to operating the marine sanitation device.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 February 2015
Electrical › Electric Generation Source (service) › Generator
Issued 25 July 2013 Resolved
Provide USCG MSC approved plans to the OCMI prior to connecting the service generator to the vessel's electrical system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 February 2018
Resolution: Deficiency has been removed and entered as a special note in lieu.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 14 November 2012 Resolved
Remove test pressure markings from cargo hoses and replace with MAWP IAW 33CFR154.500(f)(g).
Due 30 November 2012
Resolved 15 November 2012
Deck/Cargo › Holds/Tanks › Hatch
Issued 14 November 2012 Resolved
Mark the #1 & #2 cargo hatches with CC and the tank number IAW 46CFR69.76
Due 30 November 2012
Resolved 15 November 2012
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 10 November 2011 Resolved
Provide a repair plan proposal for wasted section of cargo piping and conduct pressure testing to the satisfaction of the attending marine inspector. 46CFR38.10-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2011
Resolution: witnessed satisfactory hydro test of cargo piping.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 May 2010 Resolved
Provide proper amount of retro-reflective material for (2) ring buoys.
Due 31 May 2010
Resolved 19 May 2010
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 10 May 2010 Resolved
Prove proper operation of overflow alarm for #1 port cargo tank.
Due 31 May 2010
Resolved 19 May 2010
Resolution: Manually tested overflow; observed visual and audible alarm function.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 10 May 2010 Resolved
Correct Sector San Francisco phone number in company SOPEP.
Due 31 May 2010
Resolved 19 May 2010
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 10 May 2010 Resolved
Provide flame screen for diesel tank vent.
Due 31 May 2010
Resolved 19 May 2010
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 6 September 2007 Resolved
Hydrostatic release/weaklink assembly installed upside down.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 September 2007
Resolved 6 September 2007
Resolution: Hydrostatic release/weaklink assembly installed properly.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 21 August 2006 Resolved
Update SOPEP to reflect correct USCG Sector San Francisco contact info. ([phone withheld])
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 7 September 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 August 2006 Resolved
Replace cracked waterlight attached to lifering in way of foward house.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 7 September 2006
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 21 August 2006 Resolved
Prove proper operation of #1 port cargo overfill and high level alarm.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 7 September 2006
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 August 2005 Resolved
Provide proof of current COD.
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 21 August 2006
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 29 August 2005 Resolved
Provide 4 lifejackets for a total of 16 onboard.
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 3 October 2005
Lifesaving › Immersion Suits › Not on Board
Issued 29 August 2005 Resolved
Provide 2 immersion suits for a total of 16 onboard.
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 3 October 2005
Electrical › Electrical Distribution System (service) › Conductor
Issued 29 August 2005 Resolved
Replace welding cable used in 12 volt battery starting system with marine grade battery cable.
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 3 October 2005
Engineering › Compressed Air System (start air) › Valve
Issued 29 August 2005 Resolved
Prove proper operation of lower air receiver relief valve.
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 3 October 2005
Lifesaving › Inflatable Liferafts › Markings
Issued 29 August 2005 Resolved
Provide launching placard for life raft.
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 3 October 2005
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 29 August 2005 Resolved
Provide plugs for drains in piping containment areas
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 3 October 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 15 November 2004 Resolved
Properly repair electrical cable for forward anchor light as indicated by attending inspector.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 4 February 2005
Deck/Cargo › Cargo Transfer (solid) › General
Issued 15 November 2004 Resolved
Properly secure hydraulic power unit (HPU) emergency shutdown piping from CO2 discharge to equipment shut down device.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 25 February 2005
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 15 November 2004 Resolved
Properly label all PFD's with vessel name.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 25 February 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 15 November 2004 Resolved
Provide documentation of hydrostatic test of cargo transfer piping and hoses.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 25 February 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 26 November 2003 Resolved
Repair and prove proper operation of aft cargo pump engine and remote emergency shutdown. LEGACY COMPONENT DESC: Cargo Pump
Due 26 December 2003
Resolved 11 December 2003
Engineering › Compressed Air System (start air)
Issued 26 November 2003 Resolved
Prove proper operation of air receiver relief valves. LEGACY COMPONENT DESC: Receiver/Bottle
Due 26 December 2003
Resolved 11 December 2003
Documentation
Issued 12 October 2000 Resolved
Provide stability book onboard in accordance with 46 CFR 31.10-30.
Condition: Unknown
Due 12 October 2000
Resolved 12 October 2000
Documentation
Issued 12 October 2000 Resolved
Update SOPEP and VRP with contact numbers for area of operation.
Condition: Unknown
Due 12 October 2000
Resolved 12 October 2000
Deck/Cargo
Issued 12 October 2000 Resolved
Pressure test and properly stencil, the test data on all transfer hoses.
Condition: Unknown
Due 12 October 2000
Resolved 12 October 2000
Documentation
Issued 27 August 1999 Resolved
By 27SEP99 provide pollution placard in accordance with 33 C.F.R. 155.450.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Deck/Cargo
Issued 27 August 1999 Resolved
By 27SEP99, make the overflow audio and visual alarms operable. If cargo operations need to be conducted, before operations provide person on deck with intrinsically safe radio and person by alarm panel with radio I.A.W. 46 C.F.R. 39.20.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Deck/Cargo
Issued 27 August 1999 Resolved
Prior to 27SEP99 mark cargo hoses with maximum allowable working pressure (MAWP) in accordance with 33 C.F.R. 154.500.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Construction/Loadline
Issued 4 April 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 14 April 1998
Resolved 14 April 1998
Fire Fighting
Issued 27 August 1997 Resolved
Provide oil transfer procedures.
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Fire Fighting
Issued 27 August 1997 Resolved
Show proper servicing of portable fire extinguishers.
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Accommodation/Occupational Safety
Issued 27 August 1997 Resolved
Prove proper operation of air receiver reliefs.
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Fire Fighting
Issued 27 August 1997 Resolved
Hydrostatically test or replace extinguisher for deck paint locker box.
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Lifesaving
Issued 27 September 1996 Resolved
Provide and install a weak link on the life raft's sea painter prior to operating as a manned vessel.
Condition: Unknown
Due 27 September 1996
Resolved 2 October 1996
Deck/Cargo
Issued 3 May 1994 Resolved
PROVE PROPER OPERATION OF ANCHOR PRIOR TO OPERATING.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Deck/Cargo
Issued 3 May 1994 Resolved
AIRTEST #1 STBD, #2 STBD, #3 PORT/STBD, AND #4 PORT/STBD CARGO TANKS PRIOR TO CARRYING CARGO IN THESE TANKS.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Deck/Cargo
Issued 14 September 1992 Resolved
PROVIDE/PROVE PROPER OPERATION OF STBD (FWD) REMOTE SHUTDOWN OF CARGO PUMP PRIME MOVER. DO NOT OPERATE STBD CARGO PUMP PRIME MOVER UNTIL REQUIREMENT IS SATISFIED BY ATTENDING MARINE INSPECTOR._x001C_
Condition: Unknown
Due 6 October 1992
Resolved 6 October 1992
Deck/Cargo
Issued 14 September 1992 Resolved
PROVIDE PROPER RELIEF VALVE FOR STBD (FWD) CARGO PUMP. DO NOT OPERATE STBD CARGO PUMP UNTIL REQUIREMENT MET TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 6 October 1992
Resolved 6 October 1992
Construction/Loadline
Issued 28 September 1990 Resolved
PROPERLY REPAIR WELDS REJECTED BY UT EXAMINATION ON 31AUG90. CONTACT OCMI HAMPTON ROADS FOR COPY OF U.T. REPORT THESE REPAIRS TO BE COMPLETED TO THESATISFACTION OF THE COGNIZANT OCMI NO LATER THAN THE VSLS NEXT REGULARLY SKED DRYDOCK AND IN NO CASE LATER THAN 30SEP93.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Construction/Loadline
Issued 10 December 1988 Resolved
INSERTED A 4'X7'9"X1/2" PLATE IN DAMAGED AREA OF THE #1 CARGO TANK BOTTOM PLATE, AFT, AND REPAIR ASSOCIATED INTERNALS.
Condition: Unknown
Due 10 December 1988
Resolved 10 December 1988
Construction/Loadline
Issued 10 December 1988 Resolved
INSERTED A 71'X8'2"X1/2" PLATE IN THE B STRAKE FOR THE ENTIRE LENGTH OF THE#2 STARBOARD CARGO TANK BOTTOM PLATE, AND REPAIRED ASSOCIATED INTERNALS.
Condition: Unknown
Due 10 December 1988
Resolved 10 December 1988
Construction/Loadline
Issued 10 December 1988 Resolved
INSERTED A 7'9"X4'X1/2" PLATE IN THE C STRAKE, FWD OF #4 STARBOARD CARGO TANK AND REPAIRED ASSOCIATED INTERNALS.
Condition: Unknown
Due 10 December 1988
Resolved 10 December 1988
Construction/Loadline
Issued 10 December 1988 Resolved
INSERTED 3'3"X8'X1/2 PLATE IN THE BILGE WRAPPER OF THE #4 STARBOARD CARGO TANK AND REPAIRED ASSOCIATED INTERNALS.
Condition: Unknown
Due 10 December 1988
Resolved 10 December 1988
Construction/Loadline
Issued 10 December 1988 Resolved
INSERTED A 4'X4'X1/2 PLATED IN THE A STRAKE OF #2 STARBOARD CARGO TANK, AFTAREA, AND REPAIR ASSOCIATED INTERNALS.
Condition: Unknown
Due 10 December 1988
Resolved 10 December 1988
Construction/Loadline
Issued 10 December 1988 Resolved
INSERTED A 71'X8'2"X1/2" PLATE IN THE B STRAKE OF THE ENTIRE LENGTH OF THE #3 STARBOARD CARGO TANK AND REPAIRED ASSOCIATED INTERNALS.
Condition: Unknown
Due 10 December 1988
Resolved 10 December 1988
Construction/Loadline
Issued 10 December 1988 Resolved
INSERTED A 7'9"X4'X1/2" PLATE IN THE C STRAKE, AFT, IN #3 STARBOARD CARGO TANK AND REPAIRED ASSOCIATED INTERNALS.
Condition: Unknown
Due 10 December 1988
Resolved 10 December 1988
Construction/Loadline
Issued 10 December 1988 Resolved
INSERTED A 7'9"X4'X1/2" PLATE IN THE AFT BILGE WRAPPER OF #3 STARBOARD CARGO TANK AND REPAIRED ASSOCIATED INTERNALS.
Condition: Unknown
Due 10 December 1988
Resolved 10 December 1988
Construction/Loadline
Issued 1 July 1988 Resolved
MAKE PROPER REPAIRS TO HOLE IN NO.1 PORT CARGO TANK. VSL IS PERMITTED TO PROCEED TO STD TANK TERMINAL (WITHOUT CARGO) FOR TANK CLEANING AND THEN PROCEED TO YARD TO MAKE PROPER REPAIRS.
Condition: Unknown
Due 1 July 1988
Resolved 1 July 1988
Construction/Loadline
Issued 7 February 1985 Resolved
MAKE PERMANENT REPAIRS TO FRACTURE (APPROX. 10") IN CARGO TANK #1 PORT IN WAY OF RUBRAIL. UNTIL SUCH REPAIRS ARE MADE, CARGO DEPTH IN #1 PORT IS LIMITED TO 15 FEET.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.