Records from 1985 to 2012. Most recent: inspection, 9 January 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 46
9 January 2012
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4221214
6 December 2011
Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4202955
16 November 2010
Deadweight Survey · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3895387
25 February 2010
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3686104
2 December 2008
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3372537
12 February 2008
Deficiency Check · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3146361
18 October 2007
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3085207
14 April 2006
Hull Examination · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2638652
13 December 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2551783
1 April 2005
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2331096
2 November 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2241112
30 October 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1939089
5 May 2003
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1820836
24 October 2002
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1693931
10 December 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1423692
13 November 2001
Type not recorded
No type recorded · Station Curtis Bay · USCG East District (CGD-E) · Activity 1519961
16 May 2001
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1366340
2 October 2000
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1433754
27 September 1999
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1197033
26 August 1999
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1437595
17 May 1999
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 798687
24 June 1998
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1472601
5 September 1997
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 785766
24 July 1997
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 781105
23 May 1997
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1418214
18 June 1996
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1363727
27 June 1995
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 886382
23 May 1995
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1186098
18 August 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1180913
1 July 1994
Re-Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1025333
21 April 1994
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1379951
10 November 1993
Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1132313
22 June 1993
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1153874
27 May 1992
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 952712
6 April 1992
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1264929
7 June 1991
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1244711
23 May 1991
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 927215
21 May 1990
COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1239528
18 May 1988
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1206899
13 May 1987
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1028775
28 April 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1336164
30 June 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 993827
14 May 1986
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1303204
25 November 1985
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 996029
16 May 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 980986
26 February 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 978649
Documentation › Certificates/Documents › FCC SSL
Issued 16 November 2010
Resolved
FCC safety certificate not available for examination, replace as required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 November 2010
Resolved
First Aid kit missing Aspirin, replace as required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2011
Fire Fighting › Ventilation Systems › Ducts
Issued 16 November 2010
Resolved
Vents to the engine space rusted and unable to close, repair as new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2011
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 16 November 2010
Resolved
Vessel main engine continue to over-heat as indicated by the indicators in the control station, repair to the satisfaction of the marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2011
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2010
Resolved
Massive water intrusion forward of the vessel, repair to the satisfaction of the marine inspector.
Action required: 703 - Prior to bunkering operations
Resolved 21 April 2011
Resolution: Attended vessel on 30 minute underway exercise. Repair sat.
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 16 November 2010
Resolved
Replace retro-reflective tape on 04 Lifejacket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2011
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 16 November 2010
Resolved
Replace 01 Life Jacket due to rot.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2011
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 October 2007
Resolved
Grab lines of life ring are wasted. Owner instructed to replace with CG approved buoyant line.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2007
Resolved 6 November 2007
Resolution: Vessel owner replaced ring buoys in-kind. Purchased CG approved Ring Buoys
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 18 October 2007
Resolved
Air vent built built into engine box does not properly fit into cut out space. Owner informed that he must replace closable air vent to properly fit space in engine box.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2007
Resolved 6 November 2007
Resolution: Vessel rep placed a proper air vent into the egine space. The new air vent fits properly in cut-out space
Construction/Loadline › Hull › Transverse Frame
Issued 18 October 2007
Resolved
Rotted forward bulkhead at deckline and transverse frames. Vessel owner will submit repair proposals via fax/email to Sector Baltimore
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2008
Resolved 12 February 2008
Resolution: Bulkhead repaired to the satisfaction of the attending marine inspector.
Construction/Loadline › Hull › Keel
Issued 18 October 2007
Resolved
Visual inpsection noted water leekage near the keel and stem on port side of vessel. Vessel owner will submit repair proposal via fax/email to Sector Baltimore.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2008
Resolved 12 February 2008
Resolution: Seams repaired where the water seepage was noted.
Construction/Loadline › Hull › Keel
Issued 18 October 2007
Resolved
Visual inspection noted water leekage around fuel tank on the port side near transom.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2008
Resolved 12 February 2008
Resolution: Transom repaired as required to replaced wasted wood and stop water seepage.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 December 2005
Resolved
Vessel restricted from carrying children (persons weighing <90 lbs) until replacement all three child life jackets due to excessive shrinkage.
Due 14 December 2005
Resolved 25 January 2006
Resolution: Provided three new child L/J
Electrical › Electrical Distribution System (service) › Conductor
Issued 13 December 2005
Resolved
Replace "romex" with CG approved marine cable used for fuel tank ground.
Due 12 January 2006
Resolved 25 January 2006
Resolution: Replaced with marine cable.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 December 2005
Resolved
Remove paint from mastlight and port running light.
Due 13 January 2006
Resolved 25 January 2006
Resolution: Paint removed from lenses.
Engineering › Bilge Water Management System › Pump
Issued 13 December 2005
Resolved
Provide portable bilg pump.
Due 13 January 2006
Resolved 25 January 2006
Resolution: Portable bilge pump provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 December 2005
Resolved
Renew expired FCC safety certificate and Station License.
Due 13 January 2006
Resolved 25 January 2006
Resolution: Provided copy of station license.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 2 November 2004
Resolved
Replace dry chem bottle due to wasted base of bottle.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2004
Resolved 1 April 2005
Resolution: REMOVED FROM BOAT.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 2 November 2004
Resolved
Have on board a bridge/training log book.
Due 2 December 2004
Resolved 1 April 2005
Resolution: On board.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 November 2004
Resolved
Secure high water alarm in eng.compt..
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2004
Resolved 1 April 2005
Resolution: Working.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 November 2004
Resolved
Show operation of ring buoy waterlight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2004
Resolved 1 April 2005
Resolution: Working.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 2 November 2004
Resolved
Have on board current US coast pilot and inland rules.
Due 2 December 2004
Resolved 1 April 2005
Resolution: On board.
Operations/Management › Drills/Instruction
Issued 30 October 2003
Resolved
Provide and post life jacket donning placard for the type of jacket used.
Due 30 November 2003
Resolved 17 November 2003
Resolution: Provided proper life jacket donning placard.
Electrical › Electrical Distribution System (service) › Cable
Issued 30 October 2003
Resolved
Tighten all battery cable connections at the battery.
Due 30 November 2003
Resolved 30 October 2003
Resolution: Owner tightened all connections.
Electrical › Electric Supply System (service)
Issued 30 October 2003
Resolved
Remove all twist type connectors not located with-in an enclosure and replace with crimp type. LEGACY COMPONENT DESC: Cable
Due 30 November 2003
Resolved 17 November 2003
Resolution: Removed twist-on and replaced with crimp style.
Engineering › Sea-water System (primary cooling)
Issued 30 October 2003
Resolved
Provide double clamping at both ends of raw water engine supply. LEGACY COMPONENT DESC: Piping
Due 30 November 2003
Resolved 17 November 2003
Resolution: Hose clamps installed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 24 October 2002
Resolved
PROVIDE 02 ADULT PFD'S. LIMITED TO 20 ADULT POB'S UNTIL THIS REQUIREMENT IS MET. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2003
Lifesaving › Buoyant Apparatus
Issued 24 October 2002
Resolved
PROVIDE BA WITH ADEQUATE PAINTER AND FLOAT-FREE LINK INSTALLATION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 24 October 2002
Resolved
SUPPORT PORT-SIDE EXHAUST LINE.
Due 24 November 2002
Resolved 5 May 2003
Engineering › Bilge Water Management System
Issued 24 October 2002
Resolved
PROVE OPERATION OF ALL BILGE SYSTEM (PUMP AND ALARM) FLOAT SWITCHES. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2003
Resolved 5 May 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 24 October 2002
Resolved
RENEW WASTED PIPING ON EXHAUST COOLING WATER INLET.
Due 24 November 2002
Resolved 5 May 2003
Navigation
Issued 10 December 2001
Resolved
RENEW COMPASS LIGHT.
Condition: Unknown
Due 10 December 2001
Resolved 11 December 2001
Navigation
Issued 10 December 2001
Resolved
RENEW ANCHOR LIGHT.
Condition: Unknown
Due 10 December 2001
Resolved 11 December 2001
Construction/Loadline
Issued 26 August 1999
Resolved
Port scupper (one amidship) needs to be re-fastened.
Condition: Unknown
Due 26 September 1999
Resolved 3 September 1999
Navigation
Issued 26 August 1999
Resolved
Provide a separate switch for anchor light (prestently tied in with nav running lights) and label.
Condition: Unknown
Due 26 September 1999
Resolved 29 September 1999
Construction/Loadline
Issued 26 August 1999
Resolved
Tape bilge pump wire nuts.
Condition: Unknown
Due 26 September 1999
Resolved 29 September 1999
Navigation
Issued 26 August 1999
Resolved
secure deck frame support for steering linkage. (In the way of operating station.)
Condition: Unknown
Due 26 September 1999
Resolved 3 September 1999
Fire Fighting
Issued 26 August 1999
Resolved
Tag STBD aft fire extinguisher.
Condition: Unknown
Due 26 September 1999
Resolved 3 September 1999
Navigation
Issued 26 August 1999
Resolved
Provide a coast pilot & tide table.
Condition: Unknown
Due 26 September 1999
Resolved 29 September 1999
Lifesaving
Issued 26 August 1999
Resolved
Replace lifering. Attach water light with a corrosion resistant clip.
Condition: Unknown
Due 26 September 1999
Resolved 3 September 1999
Documentation
Issued 26 August 1999
Resolved
Have FCC safety inspection conducted & show safety certificate.
Condition: Unknown
Due 26 September 1999
Resolved 29 September 1999
Navigation
Issued 26 August 1999
Resolved
Raise masthead light to 2.5 meters above gunwale & move stern light aft.
Condition: Unknown
Due 26 September 1999
Resolved 29 September 1999
Navigation
Issued 26 August 1999
Resolved
Light compass.
Condition: Unknown
Due 26 September 1999
Resolved 29 September 1999
Fire Fighting
Issued 26 August 1999
Resolved
Install heat detector in engine compartment.
Condition: Unknown
Due 26 September 1999
Resolved 29 September 1999
Lifesaving
Issued 26 August 1999
Resolved
Buoyant apparatus needs: retrotape, 18ft water light line and make up 1 loose pendant.
Condition: Unknown
Due 26 September 1999
Resolved 3 September 1999
Fire Fighting
Issued 24 July 1997
Resolved
PROPERLY STENCIL FIRE BUCKETS.
Condition: Unknown
Due 24 August 1997
Resolved 26 July 1997
Engineering
Issued 24 July 1997
Resolved
REPAIR EXHAUST LEAK MAIN ENGINE PORT SIDE.
Condition: Unknown
Due 24 August 1997
Resolved 26 July 1997
Lifesaving
Issued 24 July 1997
Resolved
REPLACE RETRO TAPE ON 4 PFD'S.
Condition: Unknown
Due 24 August 1997
Resolved 26 July 1997
Electrical
Issued 24 July 1997
Resolved
ENCLOSE TERMINAL CONNECTOR BEHIND CONSOLE.
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Lifesaving
Issued 24 July 1997
Resolved
REPLACE LIFERING THROW LINE AT 60 FT
Condition: Unknown
Due 24 July 1997
Resolved 26 July 1997
Construction/Loadline
Issued 24 July 1997
Resolved
PROVIDE CHAFFING PROTECTION FOR HYDRAULIC LINE FOR ANCHOR WINCH.
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Engineering
Issued 24 July 1997
Resolved
REMOVE E/R BLOWER MOTOR.
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Fire Fighting
Issued 24 July 1997
Resolved
REPLACE CO2 DISCHARGE LINE.
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Engineering
Issued 24 July 1997
Resolved
SECURE F/O TANK BONDING WIRE.
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Engineering
Issued 24 July 1997
Resolved
REPLACE VALVE ON TOP OF F/O TANK PORT SIDE.
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Electrical
Issued 24 July 1997
Resolved
INSTALL PROTECTIVE GUARDS ON DECK LIGHTING FIXTURES.
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Fire Fighting
Issued 24 July 1997
Resolved
HYDROSTATICALL TEST PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Lifesaving
Issued 24 July 1997
Resolved
REPLACE LIFE RING GRAB LINE AT 4XDIA.
Condition: Unknown
Due 24 August 1997
Resolved 26 July 1997
Electrical
Issued 24 July 1997
Resolved
NEATLY SECURE WIRING TO PREVENT DAMAGE. SECURE AT LEAST EVERY 24". MORE MAY BE NEEDED IN TIGHT AREAS WITH MANY TURNS.
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Lifesaving
Issued 24 July 1997
Resolved
ATTACH BA PAINTER TO VESSEL
Condition: Unknown
Due 24 August 1997
Resolved 26 July 1997
Lifesaving
Issued 24 July 1997
Resolved
PROVE OPERATION OF WATERLIGHT.
Condition: Unknown
Due 24 August 1997
Resolved 26 July 1997
Lifesaving
Issued 24 July 1997
Resolved
REPLACE BUOYANT APPARATUS GRAB LINES & FESTOON INTO BITES.
Condition: Unknown
Due 24 August 1997
Resolved 26 July 1997
Electrical
Issued 24 July 1997
Resolved
REMOVE ALL DEAD END WIRES.
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Electrical
Issued 24 July 1997
Resolved
SECURE BATTERY BOX TO DECK.
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Fire Fighting
Issued 18 June 1996
Resolved
MAKE AND POST PLACARDS FOR CO2 SYSTEM.
Condition: Unknown
Due 18 July 1996
Resolved 29 July 1996
Navigation
Issued 18 June 1996
Resolved
INSTALL STERN LIGHT.
Condition: Unknown
Due 18 July 1996
Resolved 29 July 1996
Lifesaving
Issued 18 June 1996
Resolved
STENCIL VESSEL NAME ON BA.
Condition: Unknown
Due 18 July 1996
Resolved 29 July 1996
Fire Fighting
Issued 18 June 1996
Resolved
PRIOR TO CARRYING PASSENGERS, SERVICE FIXED CO2 SYSTEM.
Condition: Unknown
Due 18 July 1996
Resolved 29 July 1996
Lifesaving
Issued 18 June 1996
Resolved
STENCIL VESSEL NAME ON 2 ADULT PFD'S.
Condition: Unknown
Due 18 July 1996
Resolved 23 July 1996
Electrical
Issued 18 June 1996
Resolved
REPLACE WIRE CONNECTORS ON BOTH BILGE PUMPS AND SELECTED WIRES BEHIND CONSOLE WITH PROPER CONNECTORS.
Condition: Unknown
Due 18 July 1996
Resolved 29 July 1996
Engineering
Issued 18 June 1996
Resolved
INSTALL A SUITABLE VISUAL OR AUDIBLE WARNING DEVICE AT THE ENGINE OPERATINGSTATION TO INDICATE FAILURE OF WATER FLOW IN THE EXHAUST COOLING SYSTEM.
Condition: Unknown
Due 18 July 1996
Resolved 29 July 1996
Electrical
Issued 18 June 1996
Resolved
INSTALL BATTERY SWITCH.
Condition: Unknown
Due 18 July 1996
Resolved 29 July 1996
Navigation
Issued 18 June 1996
Resolved
INSTALL COMPASS.
Condition: Unknown
Due 18 July 1996
Resolved 29 July 1996
Unknown
Issued 18 June 1996
Resolved
PROVIDE PROOF OF CURRENT ENROLLMENT IN A DRUG PROGRAM.
Condition: Unknown
Due 18 July 1996
Resolved 29 July 1996
Documentation
Issued 18 June 1996
Resolved
OBTAIN T-BOAT REGULATIONS OR HANDBOOK.
Condition: Unknown
Due 18 July 1996
Resolved 29 July 1996
Electrical
Issued 18 June 1996
Resolved
REMOVE WIRING FROM BILGE AREA. REMOVE/CAP DEAD WIRES.
Condition: Unknown
Due 18 July 1996
Resolved 29 July 1996
Documentation
Issued 1 July 1994
Resolved
PROVIDE ON BOARD A CURRENT COPY OF THE ATLANTIC COAST LIGHT LIST.
Condition: Unknown
Due 1 July 1994
Resolved 1 July 1994
Engineering
Issued 1 July 1994
Resolved
PROVIDE AN AUDIBLE OR VISUAL ALARM AT OR NEAR THE HELM STATION TO INDICATE LOSS OF EXHAUST COOLING WATER.
Condition: Unknown
Due 1 July 1994
Resolved 1 July 1994
Construction/Loadline
Issued 10 November 1993
Resolved
COMPLETE A CREDIT DRYDOCK EXAM TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 November 1993
Resolved 10 November 1993
Accommodation/Occupational Safety
Issued 23 May 1991
Resolved
VESSEL MUST REPLACE WARNING SIGN FOR BLOWER PRIOR TO OPERATION.
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Engineering
Issued 23 May 1991
Resolved
VESSEL MUST REPLACE FLAME SCREEN ON STBD SIDE FUEL VENT.
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991