Records from 1984 to 2022. Most recent: inspection, 11 August 2022.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 60
11 August 2022
Plan Review "T" Boat
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7616936
14 October 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7334669
20 October 2015
Examination of Repairs
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5814230
11 August 2014
Hull Examination · In-Service Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4951840
22 June 2012
Administrative Inspection
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4351958
1 July 2009
Administrative Inspection
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3520489
27 March 2009
Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3441417
13 August 2008
Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3298094
7 August 2008
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3292751
9 May 2008
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3213924
11 July 2007
Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2992380
31 May 2007
COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2946914
21 September 2006
Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2783869
24 August 2006
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2757152
19 September 2005
Re-Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2504134
25 April 2005
Hull Examination
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2338253
23 August 2004
Re-Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2178483
25 August 2003
Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1885311
8 September 2002
Examination of Repairs
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1681053
4 June 2002
COI Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1626281
11 June 2001
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 171876
5 June 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1461419
17 July 2000
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 77994
3 June 2000
Re-Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1463596
3 June 1999
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1452515
6 July 1998
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1128850
9 June 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1473377
30 June 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1113221
5 June 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1457469
21 August 1996
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 942716
3 June 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1417967
2 November 1995
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1396396
22 May 1995
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1398266
1 June 1994
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1025314
11 May 1994
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1170522
4 May 1994
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 858576
10 June 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1151550
28 May 1993
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1403641
13 July 1992
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1259197
8 June 1992
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1261820
15 May 1992
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 950923
26 July 1991
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 942757
25 July 1991
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 942836
23 May 1991
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1236508
20 December 1990
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 908537
3 November 1990
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1212421
16 May 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 930140
8 September 1989
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 889784
24 May 1989
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 896078
25 October 1988
Damage Survey · Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1202912
1 February 1988
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1016269
7 January 1988
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1009373
18 November 1987
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1025842
11 December 1986
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1024779
7 November 1986
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1016457
15 April 1986
Credit Drydock
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 999914
30 November 1985
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 996075
14 November 1985
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1305791
4 September 1985
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1294589
6 November 1984
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1284496
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 1 July 2009
Resolved
Requested owner provide written documentation on how the vessel will be maintain while the vessel is in a layup status.
Action required: 705 - Other - as specified
Due 7 September 2009
Resolved 12 August 2009
Resolution: Received - O/O stating vessel will be maintain in weekly while laid up.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 July 2009
Resolved
Owner will not be operating in 2009, issued 835 not to carry passenger until a annual COI inspection is conducted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2009
Resolved 16 June 2017
Resolution: COI expired
Engineering › Steam Boiler (propulsion) › Automation Equipment
Issued 11 August 2008
Resolved
Revise and Submit Periodic Safety Test Procedures for the vessels Propulsion Boiler IAW 46 CFR 61.40-6 & 10 and 46 CFR 62.35-20.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2009
Resolved 2 June 2009
Resolution: Received and approved Bolier Test Procedures/
Lifesaving › Hand Flares › Approval
Issued 7 August 2008
Resolved
Provide three (3) Orange Flares or proper substitutions IAW 46 CFR 180.68
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 13 August 2008
Resolution: Owner/operator purchased 3 additional red flares.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 August 2008
Resolved
Provide approval First Aid Kit (approval #160.41) IAW 46 CFR 184.710
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 15 August 2008
Resolution: New Approved First Aid Kit purchased.
Lifesaving › Lifebuoys › Approval
Issued 7 August 2008
Resolved
Provide proper Battery for ring Buoy light IAW 46 CFR 180.70
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 13 August 2008
Resolution: Owner/operator installed a proper battery for ring buoy light.
Engineering › Bilge Water Management System › Manifold
Issued 7 August 2008
Resolved
Label all bilge manifold valves IAW 46 CFR 182.510
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 27 August 2008
Resolution: Owner/operator labeled all blige manifold valves.
Electrical › Electric Generation Source (service) › Switch
Issued 7 August 2008
Resolved
Label all unidentified electric controls IAW 46 CFR 183.200
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 13 August 2008
Resolution: Owner/operator labeled all the unidentified electric controls using a ptouch.
Fire Fighting › Fire Hoses › Material
Issued 7 August 2008
Resolved
Replace three (3) existing fire hoses with approved fire hoses. Current hoses not recognized by COMDT. IAW 46 CFR 181.320
Action required: 705 - Other - as specified
Due 1 September 2008
Resolved 1 December 2008
Resolution: Owner provided information on current fire hoses onboard. CG willing to accept the hoses as long as the hoses remain in good condition, annually tested prior to operation start up and at each CG inspection.
Engineering › Steam System (main) › Valve, Relief
Issued 7 August 2008
Resolved
Replace Air Receiver Safety Valve located in engine room, port side, IAW 46 CFR 182.330
Action required: 705 - Other - as specified
Due 1 September 2008
Resolved 27 August 2008
Resolution: Owner/operator purchased and installed new air receiver safety valve.
Construction/Loadline › Structures › Deck Plating
Issued 7 August 2008
Resolved
Properly seal starboard steam line running through main deck IAW 46 CFR 179.320
Action required: 705 - Other - as specified
Due 1 September 2008
Resolved 27 August 2008
Resolution: Owner and operator puchased great stuff sealant (rated for 240 F) and sealed area around exhaust steam line, to prevent water running into compartment below deck. Assistant engineer stated the max temp flowing out at steam line was around 230 F.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 31 May 2007
Resolved
Repair/ Renew sewage line where leaking in aft peak space prior to 30 JUN 07 to the satisfaction of a Coast Guard Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 11 July 2007
Resolution: Sewage Line Repaired
Construction/Loadline › Structures › Transverse Bulkhead
Issued 31 May 2007
Resolved
Install Metallic shutoff valves in watertight bulkheads where penetrated by non metallic piping prior to 30 JUN 2007 to the satisfaction of a Coast Guard Marine Inspector. 46 CFR 182.40.1
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 11 July 2007
Resolution: Metallic Valves installed in Sewage tank space piping.
Electrical › Electrical Distribution System (service) › Conductor
Issued 31 May 2007
Resolved
Permanently install electrical conductor to potable water pump prior to 30 JUN 07 to the satisfaction of a Coast Guard Inspector.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 11 July 2007
Resolution: Pump permanenlty installed proper Metallic shielded conductor.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 24 August 2006
Resolved
Provide non-conducting mat in front of shore power panel in engine room prior to 24 SEP 2006. 46 CFR 183.330
Action required: 705 - Other - as specified
Due 24 September 2006
Resolved 21 September 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 24 August 2006
Resolved
Renew lagging on generators exhaust prior to 24 SEP 2006. 46 CFR 177.970
Due 24 September 2006
Resolved 21 September 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 August 2006
Resolved
Mark storage lockers on 2nd and 3rd decks for life jackets prior to carrying passengers IAW 46 CFR 185.604(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2006
Fire Fighting › Fire Hoses › Number
Issued 24 August 2006
Resolved
Provide fire hose for hose that failed pressure test prior to carrying passengers. 46 CFR 181.320
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2006
Engineering › Bilge Water Management System › Not Operational
Issued 24 August 2006
Resolved
Make operational bilge alarm light on bridge prior to 24 SEP 2006. 46 CFR 182.530
Action required: 705 - Other - as specified
Due 24 September 2006
Resolved 21 September 2006
Documentation › Certificates/Documents › FCC SSL
Issued 24 August 2006
Resolved
Provide current FCC station license on bridge prior to 25 SEP 2006.
Action required: 705 - Other - as specified
Due 24 September 2006
Resolved 21 September 2006
Stability › Watertight Integrity › General
Issued 24 August 2006
Resolved
Mark all watertight doors and emergency hatches prior to 24 SEP 2006.
Action required: 705 - Other - as specified
Due 24 September 2006
Resolved 21 September 2006
Construction/Loadline › Hull › Hull Plating
Issued 25 April 2005
Resolved
Hull Plating on Portside behind Generator Keel cooler had pitting beyond 25% wastage. Company is going to crop out area and replace in-kind with 100 % welding.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2005
Resolved 13 May 2005
Resolution: cropped and replaced inkind, 100% welding done.
Operations/Management › Drug and Alcohol Testing
Issued 25 August 2003
Resolved
DID NOT HAVE A COPY OF PROGRAM ON BOARD VESSEL. LEGACY COMPONENT DESC: Proof of Enrollment
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2003
Resolved 1 October 2003
Resolution: ON Board vesel.
Operations/Management › Drills/Instruction
Issued 25 August 2003
Resolved
NO LOG BOOK ON BOARD VESSEL TO VERIFY THAT DRILLS HAVE BEEN CONDUCTED.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2003
Resolved 1 October 2003
Resolution: On Board vessel
Personnel › Training
Issued 25 August 2003
Resolved
NO ONE ON VESSEL WAS CURRENT ON CPR OR FIRST AID. LEGACY COMPONENT DESC: First Aid/CPR
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2003
Resolved 1 October 2003
Resolution: Current cards
Operations/Management › Pollution
Issued 25 August 2003
Resolved
BILGES WERE FULL OF OILY RESIDUE AND EXCESS ON MACHINERY. LEGACY COMPONENT DESC: Discharge of Cargo Residue
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2003
Resolved 1 October 2003
Resolution: Cleaned
Documentation › Certificates/Documents
Issued 25 August 2003
Resolved
MISSING CURRENT DOC ON BOARD VESSEL. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2003
Resolved 1 October 2003
Resolution: Doc on Board
Engineering › Generator (propulsion/auxiliary-electric)
Issued 25 August 2003
Resolved
BATTERY CABLES ON GENERATOR WERE WORN BEYOUND REPAIR. LEGACY COMPONENT DESC: Cable
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2003
Resolved 1 October 2003
Resolution: New wires
Operations/Management › Pollution
Issued 25 August 2003
Resolved
VESSEL ENGINE ROOM BEING USED AS A GARBAGE STORAGE AREA. LEGACY COMPONENT DESC: Control of Garbage
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2003
Resolved 1 October 2003
Resolution: Cleaned
Lifesaving › Hand Flares
Issued 25 August 2003
Resolved
FLARES WERE EXPIRED. LEGACY COMPONENT DESC: Condition
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2003
Resolved 1 October 2003
Resolution: New flares
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 4 June 2002
Resolved
Move 2nd deck B-II fire extinguisher from weather deck into accomodation area. LEGACY COMPONENT DESC: Location
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 8 September 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 4 June 2002
Resolved
Replace 54 PFD's, 18 PFD's destroyed during inspection, and 36 improper type II pfd's removed from vessel. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2002
Resolved 7 June 2002
Lifesaving › Lifebuoys
Issued 4 June 2002
Resolved
Remove line from one ring buoy. LEGACY COMPONENT DESC: Stowage
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2002
Resolved 8 September 2002
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 June 2002
Resolved
Current COD not onboard.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2002
Resolved 4 June 2002
Resolution: COD produced by owner of vessel and placed onboard.
Construction/Loadline
Issued 3 June 2000
Resolved
Install bilge alarms in machinery spaces. Until alarms are installed, conduct rounds of machinery spaces at 15 minute intervals when underway with passengers.
Condition: Unknown
Due 22 June 2000
Resolved 1 December 2000
Fire Fighting
Issued 9 June 1998
Resolved
Remove fixed Halon F/F system from engine compt. System consists of (1) 1.5lbs cylinder of halon 1301 fitted with an automatic discharge head usinga heat sensor fusible link which will release halon when melted, or installa time delay with audible/visual alarms to system. (Manned Eng. Space)
Condition: Unknown
Due 9 June 1998
Resolved 9 June 1998
Electrical
Issued 9 June 1998
Resolved
REPAIR/REPLACE BROKEN LIGHT FIXTURE IWO COMPT. 5 VOID, (SEWAGE TANK VOID).
Condition: Unknown
Due 9 June 1998
Resolved 9 June 1998
Electrical
Issued 5 June 1997
Resolved
Replace missing blank on power distribution box under stairwell next to engineer stand.
Condition: Unknown
Due 5 June 1997
Resolved 5 June 1997
Engineering
Issued 3 June 1996
Resolved
REPAIR LEAKING FEED WATER PUMP.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Engineering
Issued 3 June 1996
Resolved
REPAIR LEAKING MAIN STEAM VALVE (AROUND VALVE STEM).
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Construction/Loadline
Issued 2 November 1995
Resolved
MAKE FORWARD VOIDS ACCESSIBLE TO A COAST GUARD MARINE INSPECTOR FOR INTERNAL INSPECTION, NO LATER THAN THE NEXT COI.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Construction/Loadline
Issued 2 November 1995
Resolved
MAKE FUEL TANKS AND BOILER FEED WATER TANKS ACCESSIBLE TO A COAST GUARD MARINE INSPECTOR FOR INTERNAL INSPECTION, NO LATER THAN THE NEXT COI.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Lifesaving
Issued 22 May 1995
Resolved
PROVIDE 12 ADDITIONAL ADULT PFD'S. PASSENGER CAPACITY REDUCED 138 UNTIL PROVIDED.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Construction/Loadline
Issued 22 May 1995
Resolved
EITHER PERMANENTLY SECURED ALL WATERTIGHT DOOR BELOW THE MAIN DECK OR INSTALL INDICATOR LIGHTS ON THE BRIDGE OR ENGINEER STATAION.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Electrical
Issued 22 May 1995
Resolved
PROVIDE PROTECTIVE GUARD FOR ELECTRIC HEATERS ON MAIN DECK.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Engineering
Issued 22 May 1995
Resolved
PROVIDE FLAME GUARD FOR FUEL STRAINER OR INSTALL NEW STRAINER WITH A FLAME GUARD.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Engineering
Issued 22 May 1995
Resolved
PROVIDE PROTECTIVE GUARD FOR ENGINE ROOM VENTILATION FAN.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Lifesaving
Issued 22 May 1995
Resolved
PROPERLY SECURE WATER CONDITIONER TANK .
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Electrical
Issued 22 May 1995
Resolved
INSTALL ELECTRICAL WIRE CLAMPS ON CONNECTION BOX FOR WATER HEATER
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Lifesaving
Issued 22 May 1995
Resolved
REMOVE OLD SOUND PROOFING FOAM OVER AUX GENERATOR
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Construction/Loadline
Issued 11 May 1994
Resolved
INSTALL HATCH COVER OVER VESSEL'S BOILER, AS PER PLANS.
Condition: Unknown
Due 25 June 1994
Resolved 16 May 1994
Fire Fighting
Issued 11 May 1994
Resolved
INSTALL REQUIRED FIXED CO2 SYSTEM FOR THE ENGINE ROOM
Condition: Unknown
Due 11 May 1994
Resolved 11 May 1994
Electrical
Issued 28 May 1993
Resolved
DOUBLE CLAMP ALL JACKET WATER HOSES ON GENERATOR.
Condition: Unknown
Due 28 June 1993
Resolved 16 June 1993
Navigation
Issued 15 May 1992
Resolved
PROVIDE ONE BELL.
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Navigation
Issued 15 May 1992
Resolved
PROVIDE ONE RULES OF THE ROAD BOOK.
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Documentation
Issued 23 May 1991
Resolved
PROVIDE EVIDENCE OF VALID FCC CERTIFICATE._x001C_
Condition: Unknown
Due 23 May 1991
Resolved 23 May 1991
Accommodation/Occupational Safety
Issued 3 November 1990
Resolved
INSTALL 42" PASSENGER RAILS AT THE PERIPHERY OF ALL PASSENGER DECKS, OR PROVIDE DOCUMENTATION THAT THE EXISTING 36.5" RAILS WERE APPROVED BY THE COGNIZANT OCMI AT INITIAL CERTIFICATION.
Condition: Unknown
Due 3 November 1990
Resolved 3 November 1990
Fire Fighting
Issued 16 May 1990
Resolved
HYDOSTATIC TEST AND RECHARGE 2 CO2 FIRE EXTINGUISHERS AND PLACE ON BOARD.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Electrical
Issued 16 May 1990
Resolved
MARK ALL ELECTRICAL CONTROL PANELS WITH APPARATUS CONTROLLED.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Fire Fighting
Issued 18 November 1987
Resolved
STENCIL VESSEL'S NAME TO FIRE AXE.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Lifesaving
Issued 18 November 1987
Resolved
REPLACE REFLECTIVE TAPE ON 37 ADULT PFD'S LOCATED ON SECOND DECK.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Lifesaving
Issued 18 November 1987
Resolved
PROVIDE 180 ADDITIONAL ADULT PFD'S AND 18 ADDITIONAL CHILD PFD'S OR PROVIDELETTER TO [name withheld] IN NUMBER OF PASSENGERS CARRIED.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Fire Fighting
Issued 7 November 1986
Resolved
POST PRINTED INSTRUCTIONS FOR OPERATION OF THE FIXED CO2 SYSTEM FOR ENGINE ROOM NEAR CO2 CONTROLS.
Condition: Unknown
Due 7 November 1986
Resolved 7 November 1986
Lifesaving
Issued 7 November 1986
Resolved
REPLACE LIFE RING ON MAIN DECK PRIOR TO SAILING.
Condition: Unknown
Due 7 November 1986
Resolved 7 November 1986
Deck/Cargo
Issued 7 November 1986
Resolved
ATTACH ANCHOR LINE TO ANCHOR.
Condition: Unknown
Due 7 November 1986
Resolved 7 November 1986
Accommodation/Occupational Safety
Issued 7 November 1986
Resolved
REPLACE BROKEN WINDOW ON 03 DECK STARBOARD SIDE PRIOR TO EMBARKING PASSENGERS.
Condition: Unknown
Due 7 November 1986
Resolved 7 November 1986
Accommodation/Occupational Safety
Issued 7 November 1986
Resolved
FREE JAMMED DOOR ON 03 DECK PRIOR TO EMBARKING PASSENGERS.
Condition: Unknown
Due 7 November 1986
Resolved 7 November 1986
Lifesaving
Issued 14 November 1985
Resolved
REPLACE DETERIORATED RETRO-REFLECTIVE TAPE TO THE FOURTY-ONE (41) ADULT PFD'S AND RE-STENCIL AS NECESSARY. RE-STENCIL THE NINE (9) CHILDREN'S PFD'S. PFD'S IN QUESTION LOCATED ON MAIN DECK STARBOARD SIDE.
Condition: Unknown
Due 14 November 1985
Resolved 14 November 1985
Fire Fighting
Issued 14 November 1985
Resolved
REPLACE INSULATING MATERIAL TO NOZZLE OF SEMI-PORTABLE CO2 FIRE EXTINGUISHER LOCATED AT ENTRANCE TO ENGINE ROOM.
Condition: Unknown
Due 14 November 1985
Resolved 14 November 1985