MAURY USCG vessel records
← All vessels

DOBRIN

DOBRIN is a 1997 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in October 2025, along with 10 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2025. Most recent: inspection, 28 October 2025.

Built
1997
Last inspected
28 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 October 2025
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

468426
Flag
UNITED STATES
Maury page id
psix-468426

Documentation record

Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Gross Ton
36 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

28 October 2025 Administrative Inspection · Plan Review "T" Boat · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8260013
4 December 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8036825
13 November 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8033736
14 November 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7824531
8 February 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7617022
5 December 2022 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7604166
18 November 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7353415
16 November 2020 Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7096017
13 December 2019 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6873485
24 January 2019 Examination of Repairs · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6611400
13 December 2018 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6597085
23 January 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6341955
13 December 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6322108
3 March 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6098014
3 November 2016 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6034391
5 April 2016 Drydock Extension
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5847409

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 November 2025 No resolution recorded
The following spaces must be equipped with a fire detection system of an approved type installed IAW Part 76. Vessel is currently not equipped with an approved fire detection system. Plans have been accepted locally. Vessel owner/operator to have the approved fire detection system installed prior to target date of 01MAR26. O/O to ensure opportunity is provided to allow for system diagram walk-through prior to putting power to the panel. Final systems commissioning checks will be required to the satisfaction of the attending MI.
Action required: 705 - Other - as specified
Due 1 March 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 October 2025 Resolved
The following spaces must be equipped with a fire detection system of an approved type installed IAW Part 76. Vessel is currently not equipped with an approved fire detection system. Vessel shall provide to this office, a scope of work detailing the system identified for purchase and a proposed installation plan. Coast Guard intends on reviewing the system chosen, work with the USACE on an agreed upon timeline for installation once the above scope is submitted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2025
Resolved 12 November 2025
Resolution: Received Plans, scope of work, one line diagram, and components list from the operator. Cleared this deficiency and re-issued new for final installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 October 2025 Resolved
A vessel of at least 26 feet in length must be provided with bilge lines and bilge suctions for each watertight compartment. During the bilge system test, the steering gear compartment was unable to gain prime and could not adequately demonstrate removal of nuisance water from the bilge. Follow-up attendance necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 November 2025
Resolution: Witnessed satisfactory test of the bilge suction line. Valve renewed, tested all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 October 2025 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents. MI found the first aid kit on board expired with incomplete contents. Replace with USCG approved and provide documentation to this office attesting to the same.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 November 2025
Resolution: Recieved photo of USCG approved medkit on board.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 October 2025 Resolved
A system protecting a manned space must be fitted with an approved time delay and alarm arranged to require the alarm to sound for at least 20 seconds or the time necessary to escape from the space. Servicing technician report stated the time delay (a 30 second unit) performed at 27 seconds below the rated performance standard and below the rated tolerance range of -0%. Replace or retest and submit documentation from the service tech attesting to meeting the minimum standard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 November 2025
Resolution: Timer delay test witnessed by the USCG attending MI. All sat. 30 seconds.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 October 2025 Resolved
Provision must be made for closing all supply ducts cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Supply openings at the aft of the ships house had inadequate sealing due to improper fit & wasted or missing gasket material. Repair to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2025
Resolution: Witnessed adequate closure for the ventialation system located in the aft portion of the vessel iwo the aft deck. 4 total closures.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 5 December 2022 Resolved
All hatches exposed to the weather must be watertight. The gasket material for all flush scuttles are compressed / hard and not able to seal properly. Replace all gasket for the flush hatches by 05 Jan 2023
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 5 January 2023
Resolution: Received photographs of replaced gasket for the flush hatches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 December 2022 Resolved
Starboard propel is loses stop nuts have backed off to the cotter-pin, prop was removed and area examined. It appears the nut and jamb nut were not properly seated, Item has been cleared
Action required: 10 - Deficiency Rectified
Due 5 December 2022
Resolved 5 December 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 December 2018 Resolved
Where subject to moisture, a storage cylinder must be installed to provide a space at least 51 millimeters (2 inches) between the deck and the bottom of the storage cylinder. Ensure proper installation so as to adhere to 2 inch gap between deck and bottom of CO2 cylinders.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 27 December 2018
Construction/Loadline › Structures › Machinery Space Opening
Issued 13 December 2017 Resolved
Provide proper watertight penetration (metallic) in the forward machinery bulkhead starboard side where a piping(PVC) has been installed through watertight bulkhead. Lines are for black and gray water.
Condition: Improper Installation
Due 13 January 2018
Resolved 23 January 2018
Resolution: Vessel rep sent pictures of modification installation. please refer to activity # for more details.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.