Records from 1997 to 2015. Most recent: operational control imposed, 31 July 2015.
Inspection history · 26
31 July 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5201659
31 July 2015
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5201845
17 July 2015
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5187492
27 May 2014
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4870247
26 May 2014
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4871270
24 May 2014
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4860727
22 December 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4209539
27 January 2010
Ballast Water Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination · PII Safety Exam · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3666701
20 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3666706
23 February 2009
ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3419812
18 February 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3419814
2 October 2006
MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2791954
8 July 2005
ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2418481
1 July 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2410739
30 November 2004
ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2249981
18 September 2003
Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1908040
24 February 2003
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1749483
15 February 2002
Re-Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1486998
4 December 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 296087
17 October 2000
Port Security Assessment
Type not classified · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 623005
31 July 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 280603
17 February 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 275318
14 February 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 170169
7 February 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 275137
6 February 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 425381
18 December 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 411252
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 31 July 2015
No resolution recorded
0999 - Other (Safety in General) Vsl shall be moored with sufficient lines and shore fastenings to ensure remaining in place and withstanding action of winds, currents, and suction of passing vsls. 03 lines parted while vsl was moored. Master stated it was possibly due to strong current and MT SEARACER passing by stbd side of vsl. - 33CFR162.80(b)
Action required: 705 - Other - as specified
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 July 2015
Resolved
1730-Marine Pollution Annex I- Any such ship which may discharge into to sea ballast water retained in oil fuel tanks in accordance w/ reg. 16.2 shall comply w/ para. 2 of this reg. PSCO observed 3-way valve seized in the closed postion. Ship's crew reparied valve to working condition. PSCO tested stopping device after repair and observed proper operation of the valve. MARPOL I/14
Action required: 17 - Rectify deficiencies prior to departure
Due 17 July 2015
Resolved 21 July 2015
Resolution: Received, reviewed and accepted class report from [name withheld] stating that the deficiency was rectified. OWS three way valve was repaired by ships crew and class surveryor came onboard to verify proper operation.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 24 May 2014
Resolved
0615 Before the ship leaves port all life saving appliances shall be in working order and ready for immediate use. The starboard side lifeboat was unable to start due to inoperable batteries. 74 SOLAS (09) cons - CH III REG 20.2 17
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2014
Resolution: Deficiency rectified. Crew replaced inoperable batteries. Records have show that the crew has done regular maintenance of the lifeboat and its batteries.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 24 May 2014
Resolved
0635 - Before a ship leaves port all life saving appliances shall be in working order and ready for immediate use. The emergency release for the rescue boat broke while lowering it to the embarkation deck. 74 SOLAS (09) cons CH III REG 20.2 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2014
Resolution: Vessel repaired the emergency release and provided the PSCO with photographs documenting repair.
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 February 2009
Resolved
The remote emergency shut-off valve for the Heavy Oil Service Tank was found blocked open preventing its ability to be secured in case of a fire.
Action required: 705 - Other - as specified
Due 23 February 2009
Resolved 24 February 2009
Resolution: Received, reviewed and accepted class report from NKK stating that the remote operated fuel valve was tested satisfactorily in the presence of the attending surveyor.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 23 February 2009
Resolved
The no. 1 fuel oil supply pump has a significant leak coming out of the seal.
Action required: 705 - Other - as specified
Due 2 March 2009
Resolved 24 February 2009
Resolution: Received, reviewed and accepted class report from NKK stating that the seal was replaced in the #1 fuel oil supply pump and it was tested with satisfactory results.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 15 February 2002
Resolved
Hot water heater in hospital space not functioning properly. Water from hot tap was muddy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2002
Resolved 15 February 2002
Resolution: Chief engineer repaired system prior to departure of the inspectors from the vessel. System tested: hot, clear water was produced from the tap.
Fire Fighting
Issued 4 December 2001
Resolved
Fire control plans on the weather decks are wet and wasted. Provide a new copy of the fire control plans and ensure watertight integrity of containers prior to next US port.
Condition: Unknown
Due 4 December 2001
Resolved 15 February 2002
Resolution: New fire control plans placed in plastic bags. Fire control plan containers have been renewed.
Engineering
Issued 4 December 2001
Resolved
Oily water seperator automatic valve seized and would not operate. After numerous attempts crew was able to get valve to operate. Make permenant repairs to the satisfaction of class prior to use and prior to 18 Dec 2001.
Condition: Unknown
Due 18 December 2001
Resolved 15 February 2002
Resolution: Automatic valve tested. Test sat. Reviewed report from NKK approving repairs.
Engineering
Issued 4 December 2001
Resolved
# 2 auxillary cooling pump suction piping is holed and patched. Make permenant repairs to the satisfaction of class prior to 18 Dec 2001.
Condition: Unknown
Due 18 December 2001
Resolved 15 February 2002
Resolution: Permanent repairs to #2 auxilliary pump suction piping inspected satisfactorily. Reviewed report of inspection from NKK.
Lifesaving
Issued 17 October 2000
Resolved
PORT LIFEBOAT NOT CAPABLE OF BEING LOWERED TO THE WATER. FALL PARTED AND WAS WIRE CLAMPED TOGETHER, THUS PREVENTING FALLS FROM BEING CAPABLE OF PASSING THROUGH THE SHEAVES. SOLAS 74 AMENDED CHPT III REG 19.2
Condition: Unknown
Due 18 October 2000
Resolved 18 October 2000
Accommodation/Occupational Safety
Issued 17 October 2000
Resolved
IDENTIFY AND ELIMINATE THE CAUSE OF CONTAMINATED WATER WHICH IS SUPPLIED TOTHE CREWS WATER BASINS. TO BE CORRECTED PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN. PROVIDE DOCUMENTATION OF ACTION TAKEN TO RECTIFY PROBLEM.
Condition: Unknown
Due 5 December 2001
Resolved 5 December 2001
Documentation
Issued 17 October 2000
Resolved
PROVIDE COPY OF ISM AUDIT REPORT TO MSO PUGET SOUND, WASHINGTON PRIOR TO NEXT U.S. PORT CALL.
Condition: Unknown
Due 5 December 2001
Resolved 5 December 2001
Documentation
Issued 17 February 2000
Resolved
SMS SECTION 13(PROCEDURE FOR MGMT OF DEFICIENCY AND NON-CONFORMITY) NOT COMPLIED WITH._x001C_ ISM CODE SECT 9_x001C_
Condition: Unknown
Due 1 August 2000
Resolved 1 August 2000
Documentation
Issued 17 February 2000
Resolved
MASTER NOT FAMILIAR WITH ELEMENTS OF SMS MANUAL._x001C_ _x001C_ ISM CODE SECT 6.1.2_x001C_
Condition: Unknown
Due 1 August 2000
Resolved 1 August 2000
Lifesaving
Issued 7 February 2000
Resolved
Repair frayed lifeboat gripe on starboard lifeboat._x001C_ SOLAS 74(amended) III/19.2
Condition: Unknown
Due 24 February 2000
Resolved 24 February 2000
Fire Fighting
Issued 7 February 2000
Resolved
Ensure all fire hoses are available for immediate use._x001C_ SOLAS 74(amended) II-2/21
Condition: Unknown
Due 24 February 2000
Resolved 24 February 2000
Fire Fighting
Issued 7 February 2000
Resolved
Conduct fire drill to satisfaction of Coast Guard. _x001C_ SOLAS 74 (amended) XI/4
Condition: Unknown
Due 24 February 2000
Resolved 24 February 2000