Records from 2016 to 2026. Most recent: inspection, 6 January 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 20
6 January 2026
Administrative Inspection · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8270826
18 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8190439
6 December 2024
Administrative Inspection · MTSA/ISPS Verification · ISM Exam · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8043731
30 September 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8022896
6 December 2023
MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7822153
29 August 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7822433
7 December 2022
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7596133
16 August 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7536221
14 December 2021
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7358560
24 August 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7313512
8 December 2020
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7102196
24 September 2020
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7064430
3 August 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7023870
17 July 2019
Internal Structural Exam · DAPI Audit · Drydock Exam · Administrative Inspection · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6782996
11 June 2018
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6441819
5 July 2017
Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6197715
13 April 2017
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6121123
23 January 2017
Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6075413
27 June 2016
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5920981
14 April 2016
COI Inspection · DAPI Audit · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5851825
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 December 2020
Resolved
Each nozzle must be capable of being changed between a solid and spray pattern prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 17 December 2020
Resolution: Verified replacement fire nozzle.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 December 2020
Resolved
Mark emergency exits from both bathrooms prior to carrying passengers.
Emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”
Action required: 705 - Other - as specified
Resolved 17 December 2020
Resolution: Emergency exits marked as required.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 8 December 2020
Resolved
Provide proof of current enrollment for the vessel crew in a random chemical testing program prior to carrying passengers or cargo.
Action required: 705 - Other - as specified
Resolved 17 December 2020
Resolution: DAPI enrollment verified.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 September 2020
Resolved
Vessel's scheduled COI inspection on was not able to be completed on schedule due to the COVID-19 Pandemic. The BVI is closed and they have granted an extension for BVI required vessel documents until 31OCT20. A USCG COI inspection extension is granted until 31OCT20.
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 8 December 2020
Resolution: Completed satisfactory COI exam and issued COI.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 13 April 2017
Resolved
Repair exhaust leaks in steering compartment on generator exhaust piping in way of flexible coupling and muffler.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 1 May 2017
Resolution: Re-inforced exhuast by lay up FRP
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 13 April 2017
Resolved
Repair flexible coupling on fuel vent piping.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 18 April 2017
Resolution: renewed flex coupling
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 13 April 2017
Resolved
Provide adequate supports on generator exhaust piping and fuel vent piping.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 1 May 2017
Resolution: Supported with metal hangars
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 April 2017
Resolved
Install metallic wire hangers for power conductors.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 1 May 2017
Resolution: Metal wire clamps installed
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 13 April 2017
Resolved
DAPI program records not available for inspection. Vessel to contact USCG MSD St Thomas marine inspectors to schedule DAPI audit.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 18 April 2017
Resolution: DAPI audit complete
Electrical › Electric Generation Source (service) › Generator
Issued 25 January 2017
Resolved
Provide written report of service generator detailing cause of failure and repair response. Correct prior to conducting sea trials.
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 26 January 2017
Resolution: Vessel provide written report describing cleaning water ingress into voltage regulator and resolution.
Engineering › Fuel Oil Service System › Hose
Issued 23 January 2017
Resolved
Port engine was found to have (03) three oil non-metallic hoses ruptured and oil spray was found covering aft portion of engine and reduction gear. Prior to movement, demonstrate integrity (replace) oil lines, clean oil spray, and show proper operation of port engine including turbo.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 January 2017
Resolved 26 January 2017
Resolution: Vessel deomonstrated replcement of hoses, removal of oil and underway sea trial after installation of replacement turbocharger.
Construction/Loadline › Hull › Hull Plating
Issued 28 June 2016
Resolved
Crop and renew pitted plating port and starboard of keel forward of fuel tank to forward bulkhead of space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 12 July 2016
Resolution: Plating renewed. Fit up and NDT verified by flag inspector.
Engineering › Bilge Water Management System › Piping
Issued 28 June 2016
Resolved
Renew wasted bilge piping forward of fuel tank to good metal.
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 12 July 2016
Resolution: Piping renewed.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 28 June 2016
Resolved
Reweld broken port rudder strut in lazarette.
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 12 July 2016
Resolution: Port rudder strut rewelded.
Construction/Loadline › Hull › Longitudinal Frame
Issued 28 June 2016
Resolved
Gouge and reweld broken welds on longitudinal engine mounts forward of engines. Broken welds observed on the inboard side of both engines and outboard of starboard engine.
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 12 July 2016
Resolution: Welds rewelded and verified by attending MI.
Construction/Loadline › Hull › Hull Plating
Issued 28 June 2016
Resolved
Drill stop, gouge and reweld cracked existing weld repair on starboard rudder.
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 12 July 2016
Resolution: Welds drill stopped and rewelded. Verified by flag inspector.
Engineering › Bilge Water Management System › Valve
Issued 14 April 2016
Resolved
Repair or replace broken valve handle on forepeak bilge valve.
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 10 May 2016
Resolution: Valve hand replaced and proper operation witnessed.
Engineering › Fuel Oil Service System › Valve
Issued 14 April 2016
Resolved
Prove proper operation of emergency fuel shut-off valve.
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 10 May 2016
Resolution: Proper operation witnessed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 April 2016
Resolved
Provide batteries for ring buoy water light.
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 10 May 2016
Resolution: New batteries installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 April 2016
Resolved
Provide water light lanyard with clip.
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 10 May 2016
Resolution: Laynard and clip installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 April 2016
Resolved
Provide GPS enabled VHF radio.
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 10 May 2016
Resolution: Proper operation witnessed. DSC test call sent to Sectyor San Juan with positive results.