Records from 1998 to 2024. Most recent: inspection, 29 February 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting
Issued 26 February 1998
Resolved
Remove equipment stored behind open swithboard in engine room (fire hazard).
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Navigation
Issued 26 February 1998
Resolved
Provide emergency steering instructions in language understood by officers and crew (missing).
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Fire Fighting
Issued 26 February 1998
Resolved
Remove excessive fuel oil from containment around fuel oil day tanks.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Engineering
Issued 26 February 1998
Resolved
Remove excessive oil in engine room bilges.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Engineering
Issued 26 February 1998
Resolved
Renew patched fuel oil return lines on starboard diesel generator (leaking).
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Engineering
Issued 26 February 1998
Resolved
Repair fuel oil flange in way of day tank & deck (leaking)._x001C_ _x001C_
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Fire Fighting
Issued 26 February 1998
Resolved
Prove proper operation emergency fire pump prior to loading cargo.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Construction/Loadline
Issued 26 February 1998
Resolved
Repair WTD to emergency fire pump and paint locker room (missing dogs).
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Engineering
Issued 26 February 1998
No resolution recorded
Place protective metal guards on fuel glass sites (missing).
Condition: Unknown
Due 12 March 1998 — due date passed with no resolution recorded
Electrical
Issued 26 February 1998
No resolution recorded
Provide protection light globes in engine room (missing).
Condition: Unknown
Due 12 March 1998 — due date passed with no resolution recorded
Fire Fighting
Issued 26 February 1998
No resolution recorded
Repair fire hydrant on starboard side foscle (leaking).
Condition: Unknown
Due 12 March 1998 — due date passed with no resolution recorded
Lifesaving
Issued 26 February 1998
Resolved
Repair flemming gear (broken welds).
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Navigation
Issued 26 February 1998
Resolved
Prove proper operation of steering gear (unable to control rudder on starboard steering pump).
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Construction/Loadline
Issued 26 February 1998
Resolved
Provide nuts on manhole hatch in steering gear room (missing).
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Engineering
Issued 26 February 1998
No resolution recorded
Provide permanant containment for bulk lube oil fittings (missing).
Condition: Unknown
Due 12 March 1998 — due date passed with no resolution recorded
Documentation
Issued 26 February 1998
No resolution recorded
Provide complete bunkering transfer procedures (line diagrams missing).
Condition: Unknown
Due 12 March 1998 — due date passed with no resolution recorded
Documentation
Issued 26 February 1998
Resolved
Provide First Officer in accordance to Safe Manning Certificate (missing).
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 2 January 1998
Resolved
Provide discharge containment around all fuel tank discharge vents and bunkering stations.
Condition: Unknown
Due 5 January 1998
Resolved 29 February 2024
Resolution: 29FEB2024: Due to age of open deficiencies issued from Sector Miami, I have cleared them to clean up Sector Miami Open Deficiencies List.
Lifesaving
Issued 2 January 1998
Resolved
Provide required lifeboat equipment.
Condition: Unknown
Due 2 January 1998
Resolved 8 January 1998
Lifesaving
Issued 2 January 1998
Resolved
Provide 03 two way VHF radios for the lifeboats.
Condition: Unknown
Due 2 January 1998
Resolved 8 January 1998
Fire Fighting
Issued 2 January 1998
Resolved
Make permanent repairs to wasted areas of firemain system.
Condition: Unknown
Due 2 January 1998
Resolved 8 January 1998
Engineering
Issued 2 January 1998
Resolved
Prove proper operation of ows.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Fire Fighting
Issued 2 January 1998
Resolved
Prove proper operation of #2 fire pump.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Navigation
Issued 2 January 1998
Resolved
Prove proper of steering system from bridge and flat in all modes operation.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Navigation
Issued 2 January 1998
Resolved
Provide steering gear instructions in language understood by crew.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Fire Fighting
Issued 2 January 1998
Resolved
Class to address whether vessel is required to have an independent emergency fire pump.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Lifesaving
Issued 2 January 1998
Resolved
Class to address ongoing repairs and condition of main engines.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Lifesaving
Issued 2 January 1998
Resolved
Class to address condition of purifier flat.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Lifesaving
Issued 2 January 1998
Resolved
Class to address general housekeeping of main engine room.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Fire Fighting
Issued 2 January 1998
Resolved
Conduct fire and boat drill. Drills to be verified by satisfactory by flag/class prior to CG witnessing drills.
Condition: Unknown
Due 5 January 1998
Resolved 8 January 1998
Documentation
Issued 2 January 1998
Resolved
Provide oil transfer procedures and pipe diagram iaw 33 CFR 155.700, 710 and 720.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Unknown
Issued 2 January 1998
Resolved
Properly label all equipment in main engine room in language inderstood by crew.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Documentation
Issued 2 January 1998
Resolved
Class/flag to provide written report addressing all items listed above prior to CG attending vessel.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Fire Fighting
Issued 2 January 1998
Resolved
Provide 01 additional firemans outfit for total of 02 outfits.
Condition: Unknown
Due 2 January 1998
Resolved 8 January 1998
Lifesaving
Issued 2 January 1998
Resolved
Provide required liferafts.
Condition: Unknown
Due 2 January 1998
Resolved 8 January 1998
Fire Fighting
Issued 2 January 1998
Resolved
Provide spanner wrenches for all fire stations.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Fire Fighting
Issued 2 January 1998
Resolved
Provide servicing report for fixed CO2 system.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Fire Fighting
Issued 2 January 1998
Resolved
Provide international shore connection.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Fire Fighting
Issued 2 January 1998
Resolved
Provide written instructions on CO2 system operation in language understoodby crew.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Lifesaving
Issued 2 January 1998
Resolved
Provide lifejackets with lights and whistles for all crew members.
Condition: Unknown
Due 2 January 1998
Resolved 8 January 1998
Unknown
Issued 2 January 1998
Resolved
Provide written instructions from company to master on policies & procedures for vessel familiarization.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Documentation
Issued 2 January 1998
Resolved
Provide waste management plan and start logging of garbage disposal.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Construction/Loadline
Issued 2 January 1998
Resolved
Mark name of vessel and port on vessel hull.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Construction/Loadline
Issued 2 January 1998
Resolved
Permanently mark vessel hull as stated on vessel's loadline certificate.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Lifesaving
Issued 2 January 1998
Resolved
Prove proper operation of remote shutdowns for ventilation, fuel transfer pumps and fuel quick closing valves.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Documentation
Issued 2 January 1998
Resolved
Provide statement from flag accepting non-flag issued licenses.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Documentation
Issued 2 January 1998
Resolved
Update SOPEP with vessel information and new vessel owner.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Navigation
Issued 2 January 1998
Resolved
Provide all required navigation charts and publications.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Lifesaving
Issued 2 January 1998
Resolved
Service expired SARTS.
Condition: Unknown
Due 12 January 1998
Resolved 12 January 1998
Documentation
Issued 2 January 1998
Resolved
Provide from flag that vessel is properly manned per vessels safe manning certificate. Must provide proof of valid license for any change of crew.
Condition: Unknown
Due 5 January 1998
Resolved 8 January 1998
Construction/Loadline
Issued 2 January 1998
Resolved
Make free all dogs on cargo hold access hatches, ventilation closures and weather deck access doors.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Documentation
Issued 2 January 1998
Resolved
Provide original supplements of IOPP and Safety Equipment certificates.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Fire Fighting
Issued 2 January 1998
Resolved
Provide 02 safety lamps for emergency gear locker.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 2 January 1998
Resolved
Provide following equipment for lifeboats: rescue quiots, radar reflectors and sea anchors.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 2 January 1998
Resolved
Prove astern operation of both lifeboats.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Fire Fighting
Issued 2 January 1998
Resolved
Provide spare breathing bottles for both SCBA's.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Fire Fighting
Issued 2 January 1998
Resolved
Prove proper operation of emergency fire pump or alternate means of providing fire fighting water outside machinery space.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Documentation
Issued 2 January 1998
Resolved
Flag to address why form E of Safety Equipment Certificate list a rescue boat.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Navigation
Issued 2 January 1998
Resolved
Conduct prearrival and departure test and commence logging tests IAW 33CFR and SOLAS 74.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Construction/Loadline
Issued 2 January 1998
Resolved
Make free closure devices for ventilation fire damper vents.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 2 January 1998
Resolved
Provide instructions for maintenance of lifesaving and fire fighting equipment.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998