PHOENIX OF TORTOLA
PHOENIX OF TORTOLA is a 1971 freight ship. The Coast Guard has recorded 12 inspections since 1981, most recently in June 1994, along with 93 deficiencies and 2 operational controls.
Records from 1981 to 1994. Most recent: inspection, 30 June 1994.
- Built
- 1971
- Last inspected
- 30 June 1994
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 93 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
531750
7103801 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
46853
Flag
UNITED KINGDOM
—
Maury page id
psix-46853
Inspections, by type
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it299 - Regulatory (Subpart C or D), Gross Ton
203 - Regulatory (Subpart C or D), Net Ton
203 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
30 June 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1173180
29 June 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 368218
28 March 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 655398
24 February 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 364812
24 February 1994
MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1353530
25 April 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 324759
16 July 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 317639
8 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308271
20 July 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1281837
16 June 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 968501
8 June 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277877
14 May 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276546
Deficiency record · 93
Construction/Loadline
Issued 29 June 1994
Resolved
PROVIDE PROPER REPAIRS, RENEW GASKETS, AND MAKE ADJUSTMENTS AS NECESSARY TOALL WATERTIGHT DOORS.
Fire Fighting
Issued 29 June 1994
Resolved
ALL FIRE STATIONS MISSING SPANNER WRENCHES.
Fire Fighting
Issued 29 June 1994
Resolved
FORWARD FIRE STATION MISSING HOSE, NOZZLE, AND WRENCH.
Engineering
Issued 29 June 1994
Resolved
PROVIDE SIGHT GLASS AND PROPER GUARD WHERE MISSING ON STBD FUEL OIL DAY TANK.
Electrical
Issued 29 June 1994
Resolved
PROVIDE ADEQUATE BATTERY BOXES WITH LEAD OR FIBERGLASS LINERS AND COVERS.
Engineering
Issued 29 June 1994
Resolved
REMOVE 55 GALLON DRUM OF LUBE OIL FROM VESSEL.
Engineering
Issued 29 June 1994
Resolved
PROVIDE THE PUMPING, PIPING, AND DISCHARGE ARRANGEMENTS FOR OCEANGOING SHIPS IN ACCORDANCE WITH 33 CFR 155.420.
Engineering
Issued 29 June 1994
Resolved
PORT FUEL OIL TANK ACCESS COVER LEAKING AND MISSING BOLTS.
Engineering
Issued 29 June 1994
Resolved
PROVIDE PROPER REPAIRS TO LEAKING HOSE FOR PORT MDE EXPANSION TANK.
Construction/Loadline
Issued 29 June 1994
Resolved
REMOVE EXCESSIVE BLIGE OILY WATER FROM BILGES FRO DISPOSAL ASHORE.
Engineering
Issued 29 June 1994
Resolved
FUEL OIL FILTERS ON BOTH MDE AND SSG MISING THE REQUIRED METAL FLAME DEFLECTORS.
Engineering
Issued 29 June 1994
Resolved
PROVIDE PROPER REPAIRS TO FUEL AND LUBE OIL VENT CONTAINMENT WHERE WASTED.
Lifesaving
Issued 29 June 1994
Resolved
MAKE ALL VESSEL INTERNALS AVAILABLE FOR INTERNAL EXAMINATION AND HULL GAUGINGS AS REQUIRED BY CLASS SURVEYOR AND PROVIDE REPORT TO COGNIZANT OCMI.
Accommodation/Occupational Safety
Issued 29 June 1994
Resolved
MAKE PROPER REPAIRS TO SEWAGE LINE INSIDE #2 PORT BALLAST TANK.
Construction/Loadline
Issued 29 June 1994
Resolved
BALLAST TANKS FOUND TO BE HOLED AND PLATING SEVERELY WASTED: #2 PORT, #3 PORT/STBD, #4 PORT/STBD, #5 PORT/STBD.
Construction/Loadline
Issued 29 June 1994
Resolved
MAKE PROPER REPAIRS AS ORIGINAL TO WASTED BALLAST LINES IN PASSAGEWAY LEADING AFT TO ENGINE ROOM.
Construction/Loadline
Issued 29 June 1994
Resolved
REPAIR/REPLACE VALVES IN BALLAST SYSTEM THAT ARE DAMAGED OR REMOVED.
Accommodation/Occupational Safety
Issued 29 June 1994
Resolved
TYPE II MARINE SANITATION DEVICE IS PRESENTLY NON OPERATIONAL. RESENT TYPEII TANK IS PIPED INTO THE BALLAST SYSTEM MANIFOLD. MAKE PROPER REPAIRS TO SAME FOR FULL COMPLIEANCE WITH THE REQUIREMENTS OF 33 CFR 159.
Fire Fighting
Issued 29 June 1994
Resolved
MAKE PROPER REPAIRS TO HOLED FIRE MAIN IN THE ENGINE ROOM. NUMEROUS SOFT PATCHES AND PINHOLE LEAKS FOUND.
Construction/Loadline
Issued 29 June 1994
Resolved
MAKE PROPER REPAIRS TO BALLAST LINE AT ENGINE ROOM OVERHEAD JUST AFT OF THEENIGNE ROOM FORWARD WATERTIGHT DOOR.
Engineering
Issued 29 June 1994
Resolved
BOTH REMOTE FUEL SHUTOFF VALVES TO DAY TANKS HAVE BEEN DISCONNECTED.
Electrical
Issued 29 June 1994
Resolved
PROPERLY DEAD END WIRING IN THE ENGINE ROOM.
Electrical
Issued 29 June 1994
Resolved
REPLACE ALL EXISTING PLASTIC TIE WRAPS FOR WIRING WITH METAL TIE WRAPS NOT LESS THAN 3/16" WIDE.
Navigation
Issued 29 June 1994
Resolved
PROVIDE COTTER PINS WHERE MISSING ON STEERING GEAR.
Navigation
Issued 29 June 1994
Resolved
PROVIDE BOLTS AND NUTS TO PORT RUDDER POST PACKING GLAND WHERE MISSING.
Navigation
Issued 29 June 1994
Resolved
MAKE PERMANENT REPAIRS TO THE PORT HYDRAULIC ACCUMULATOR SUPPORT WHERE WASTED AND CRACKED.
Engineering
Issued 29 June 1994
Resolved
PROVIDE PROPER GUARD FOR PORT FUEL OIL DAY TANK SIGHT GLASS WHERE MISSING.
Navigation
Issued 29 June 1994
Resolved
PROVIDE PROTECTION OR REROUTE STEERING GEAR HYDRAULIC HOSES WHERE RUBBING AGAINS JAGGED STEEL.
Navigation
Issued 29 June 1994
Resolved
PROVIDE RUDDER STOPS AS REQUIRED BY 46 CFR 58.25-35.
Navigation
Issued 29 June 1994
Resolved
PROVIDE PROPER REPAIRS TO STBD HYDRAULIC STEERING GEAR ACCUMULATOR WHERE LEAKING.
Deck/Cargo
Issued 29 June 1994
Resolved
PROVIDE PROPER MAINTENACE AND SECURING DEVICE FOR CHAIN LOCKER MANHOLE COVER.
Construction/Loadline
Issued 29 June 1994
Resolved
MAKE ALL THROUGH BULKHEAD FITTINGS IN ENGINE ROOM WATERTIGHT.
Electrical
Issued 29 June 1994
Resolved
PROVIDE PROPER STUFFING FOR ELECTRICAL CABLEWAY, 01 DECK, AFT BULKHEAD.
Accommodation/Occupational Safety
Issued 29 June 1994
Resolved
PROVIDE PROPER RAIL AT 01 DECK AFT OF PILOTHOUSE WHERE MISSING PER 46 CFR 92.25-5.
Construction/Loadline
Issued 29 June 1994
Resolved
PROVIDE PROPER REPAIRS TO BALLAST LINE IN STEERING GEAR FLAT AT CENTERLINE JUST FORWARD OF AFT BULKHEAD WHERE SOFT PATCH PRESENTLY EXISTS.
Navigation
Issued 29 June 1994
Resolved
PROVIDE NAVIGATION LIGHTS IN ACCORDANCE WITH 72 COLREGS. PRESENT LIGHTS HAVE CERAMIC HOUSEHOLD FIXTUES WITH INCANDESCENT LIGHT BULBS.
Electrical
Issued 29 June 1994
Resolved
ELECTRICAL CONDUIT AFT OF MAIN DECK HOUSE WATERTIGHT DOOR LOOSE AND UNDSUPPORTED.
Lifesaving
Issued 29 June 1994
Resolved
PROVIDE THE DISTRESS SIGNALS REQUIRED BY 46 CFR 94.90 ( I.E. 12 PARACHUTE FLARES).
Navigation
Issued 29 June 1994
Resolved
PROVIDE SOUND SIGNALLING DEVICE AS REQUIRED BY 72 COLREGS.
Lifesaving
Issued 29 June 1994
Resolved
PROVIDE CLASS A EPIRB AS REQUIRED BY 94.60-1.
Navigation
Issued 29 June 1994
Resolved
PROVIDE THE CHARTS AND NAUTICAL PUBLICATIONS AS REQUIRED BY 46 CFR 97.05-5 (CHARTS NOT CURRENT, MISSING ALL OTHER PUBS).
Navigation
Issued 29 June 1994
Resolved
PROVIDE CURRENT MAGNETIC COMPASS DEVIATION TABLE (LAST DEVIATION DONE 4/92).
Documentation
Issued 29 June 1994
Resolved
PROVIDE MINIMAL MANNING AS REQUIRED BY 46 USC 8301.
Documentation
Issued 29 June 1994
Resolved
PROVIDE DOCUMENTATION FROM FLAG STATE WITH REGARD TO THE ACCEPTANCE OF CREWLICENSES ISSUED BY A GOVERNMENT OTHER THAN THE FLAG STATE TO WHICH THE VESSEL IS REGISTERED.
Lifesaving
Issued 29 June 1994
Resolved
PROVIDE EIGHT TOTAL RING BOUYS, SIX OF WHICH MUST HAVE APPROVED WATERLIGHTSAND PROVIDE PROPER STOWAGE.
Lifesaving
Issued 29 June 1994
Resolved
PROVIDE AN ADDITIONAL THREE TYPE I PFD'S WITH WATER LIGHTS AND WHISTLES AS REQUIRED BY 46 CFR 94.40-10.
Documentation
Issued 29 June 1994
Resolved
PROVIDE CURRENT MEDICAL CERTIFICATES ISSUED BY THE FLAG STATE FOR ALL CREW IN ACCORDANCE WITH ILO 147.
Accommodation/Occupational Safety
Issued 29 June 1994
Resolved
PROVIDE PROPER CLEANING OF GALLEY RANGE EXHAUST FANS AND PROVIDE SCREENS FOR SAME.
Accommodation/Occupational Safety
Issued 29 June 1994
Resolved
PROVIDE PROPER REPAIRS TO OUTBOARD GALLEY RANGE EXHAUST FAN.
Electrical
Issued 29 June 1994
Resolved
PROVIDE ILLUMINATION FOR LIFERAFT STORAGE AREA PER 46 CFR 94.50-15.
Lifesaving
Issued 29 June 1994
Resolved
PROPERLY MARK LOCATION OF LIFE JACKETS.
Deck/Cargo
Issued 29 June 1994
Resolved
POVIDE STABILITY AND LOADING INFORMATION FOR MASTER ISSUED OR RECOGNIZED BYTHE FLAG STATE OR THEIR REPRESENTATIVES.
Fire Fighting
Issued 29 June 1994
Resolved
PROVIDE ONE ADDITIONAL C-II PORTABLE FIRE EXTINGUISHER PER 46 CFR 95.50.10(A).
Documentation
Issued 29 June 1994
Resolved
PROVIDE DOCUMENTATION/CERTIFICATION FROM CLASS SOCIETY WITH REGARD TO ACCEPTANCE OF PRESENT ANCHORING ARRANGEMENT.
Lifesaving
Issued 29 June 1994
Resolved
PROVIDE A SELF ACTIVATED SMOKE SIGNALLING DEVICE PER 46 CFR 94.43-5(C).
Fire Fighting
Issued 29 June 1994
Resolved
PROVIDE TWO COMPLETE FIREMAN'S OUTFITS PER 46 CFR 96.35-10 AND SPARE CHARGES PER 46 CFR 96.35-20.
Documentation
Issued 29 June 1994
Resolved
LOAD LINE CERTIFICATE EXPIRED.
Construction/Loadline
Issued 29 June 1994
Resolved
LOAD LINE IMPROPERLY MARKED WITH REGARD TO LOCATION ONHULL AND LACKING DECKMARK.
Construction/Loadline
Issued 29 June 1994
Resolved
DRAFT MARKS NOT MARKED ON VESSEL.
Construction/Loadline
Issued 29 June 1994
Resolved
BALLAST TANK VENTS NOT FITTED WITH CLOSURE DEVICES.
Construction/Loadline
Issued 29 June 1994
Resolved
BALLAST TANK VENTS WASTED.
Engineering
Issued 29 June 1994
Resolved
TOP OF PORT EXHUAST TRUNK WASTED.
Construction/Loadline
Issued 29 June 1994
Resolved
ALL BALLAST TANK MANHOLE COVERS ON COARGO DECK ARE CEMENTED IN ORDER TO MAKE WATERTIGHT.
Construction/Loadline
Issued 29 June 1994
Resolved
PROVIDE COMPLETE BALLAST TANK CLOSURE DEVICES AND RENEWED GASKETS WHERE MISSING THROUGHOUT VESSEL.
Engineering
Issued 29 June 1994
Resolved
FUEL VENTS ON MAIN DECK MISSING VENT SCREENS.
Electrical
Issued 29 June 1994
Resolved
MAKE PROPER REPAIRS TO EMERGENCY LIGHTING THROUGHOUT THE VESSEL.
Lifesaving
Issued 29 June 1994
Resolved
PROVIDE FIRE AND GENERAL SAFETY GEAR PLAN.
Electrical
Issued 29 June 1994
Resolved
PROVIDE GUARDS FOR SSG FLYWHEELS PER 46 92.25-15.
Electrical
Issued 29 June 1994
Resolved
SHIP SERVICE LIGHTING: NON-OPERATIONAL, MISSING GLOBES AND GUARDS, MISSING COVERS, MISSING SUPPORTS, POOR WIRING PRACTICE.
Construction/Loadline
Issued 24 February 1994
Resolved
TEMPORARY PLUGS WERE INSERTED BENEATH THE WATER LINE IN THE AFTER STEERING COMPARTMENT SIDESHELL ON THE PORT SIDE.
Construction/Loadline
Issued 24 February 1994
Resolved
FRACTURED WELDS IN FRAMES THROUGHOUT THE ENGINEROOM AND OVERHEAD CUT OUT INWAY OF #1 MAIN ENGINE.
Accommodation/Occupational Safety
Issued 24 February 1994
Resolved
VESSEL HAS INSTALLED TOILET FACILITIES AND MARINE SANITATION DEVICE IS NOT OPERABLE.
Electrical
Issued 24 February 1994
Resolved
EXCESS ELECTRICAL WIRING NOT IN USE THROUGHTOUT VESSEL, ELECTRICAL SPLICES ARE TEMPORARILY CONNECTED, AND ELECTRICAL BOXES ARE EXPOSED WITH MANY WIRESPROTRUDING.
Fire Fighting
Issued 24 February 1994
Resolved
FIREFIGHTING PIPING AND VALVES ARE DEFECTIVE AND THERE IS NO FIRE HOSE IN ENGINEROOM AT THE STATION.
Electrical
Issued 24 February 1994
Resolved
ELECTRICAL GRADE NON-CONDUCTIVE MATTING MISSING AT THE ELECTRICAL SWITCHBOARD.
Construction/Loadline
Issued 24 February 1994
Resolved
HOLES IN OVERHEAD OVER #2 MAIN ENGINE.
Lifesaving
Issued 24 February 1994
Resolved
LIFERAFT/LIFEBOAT WITH REQUIRED EQUIPMENT WAS NOT ON BOARD THE VESSEL.
Construction/Loadline
Issued 24 February 1994
Resolved
FORWARD WATER TIGHT BULKHEAD NOT WATER TIGHT DUE TO CABLE RUNS.
Electrical
Issued 24 February 1994
Resolved
ELECTRICAL SWITCHBOARD GAUGES ARE NOT OPERABLE.
Lifesaving
Issued 24 February 1994
Resolved
REQUIRED AMOUNT OF APPROVED LIFEJACKETS NOT ON BOARD THE VESSEL AND VESSEL'S LIFERING WAS DETERIORATING.
Documentation
Issued 24 February 1994
Resolved
VESSEL HAS LOADLINE CERTIFICATE ISSUED BY PANAMA BUREAU OF SHIPPING. THIS CLASSIFICATION SOCIETY (PBS) IS NOT EMPOWERED TO CARRY OUT SURVEYS OR ASSIGN LOADLINES FOR ANY VESSEL REGISTERED ON THE BRITISH FLAG, THIS INCLUDES ALL THE DEPENDANT TERRITORIES OF WHICH ANGUILLA IS ONE.
Construction/Loadline
Issued 24 February 1994
Resolved
THE MAJORITY OF THE PORT COMPARTMENT AFTER STEERING FRAMES ARE WASTED BEYOND RECOGNIZED ALLOWABLE STANDARDS.
Deck/Cargo
Issued 24 February 1994
Resolved
ANCHOR WINDLASS IS INOPERABLE.
Engineering
Issued 24 February 1994
Resolved
PORT PROPULSION SHAFT HAS EXCESSIVE WATER LEAKAGE.
Documentation
Issued 24 February 1994
Resolved
CORRECT THE DEFICIENCIES CONTAINED IN CAPTAIN OF THE PORT ORDER #15-94.
Documentation
Issued 25 April 1988
Resolved
MASTER WAS UNABLE TO PRODUCE AN IOPP CERTIFICATE AS REQ BY 33 CFR 151.19(A)
Documentation
Issued 25 April 1988
Resolved
MASTER WAS UNABLE TO PRODUCE A SOLAS SAFETY RADIOTELEPHONE CERTIFICATE AS REQ BY 46 CFR 91.60 AND SOLAS REG. 12 CH 1.
Documentation
Issued 25 April 1988
Resolved
MASTER STATED THAT THE VESSEL DID NOT HAVE AN OIL RECORD BOOK ON BOARD AS REQUIRED BY 33 CFR 151.25(I)
Documentation
Issued 25 April 1988
Resolved
MASTER WAS UNABLE TO PRODUCE A FINANCIAL RESPONSIBILITY CERTIFICATE AS REQ BY 33 CFR 130.3(A)
Documentation
Issued 25 April 1988
Resolved
MASTER WAS UNABLE TO PRODUCE A VALID LOADLINE CERTIFICATE AS REQUIRED BY 46 CFR 42.07-45
Unknown
Issued 8 June 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL PHOENIX, DN531750.
Unknown
Issued 8 June 1983
Resolved
PROVIDE CALCULATIONS TO MMT FOR STABILITY REVIEW OF HIGHER CENTER OF GRAVITY DUE TO SEISMIC EQUIPMENT DECK CARGO.
Engineering
Issued 8 June 1983
Resolved
REPAIR EXHAUST INSULATION IN WAY OF ENGINE ROOM EMERGENCY ESCAPES.