MAURY USCG vessel records Sign in
← All vessels

MISS CHARLOTTE

MISS CHARLOTTE is a 1998 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 1998, most recently in July 2025, along with 31 deficiencies — 3 with no resolution recorded — and 1 casualty investigation in 2004.

Records from 1998 to 2025. Most recent: inspection, 29 July 2025.

Built
1998
Last inspected
29 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8982539 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDJ8262
468533
Flag
UNITED STATES
368014720
Maury page id
psix-468533

Inspections, by type

…with no type recorded4
…past their stated due date3
Years with a record 23 calendar years (1998–2025)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)121.4 ft × 27.0 ft × 11.7 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)121.4 ft × 27.0 ft × 11.7 ft
ITC tonnagegross 251 / net 75
BuilderBREAUX BROS ENTERPRISES · LOREAUVILLE, LA, UNITED STATES · built 1998
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 17 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
251 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
75 - Convention (Subpart B), Net Ton
100 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ8262MMSI 368014720 · active · compulsorily equipped · granted 1 December 2017, expires 1 December 2027
WDF4652MMSI 367454290 · expired · compulsorily equipped · granted 27 May 2010, cancelled 1 August 2020 · licensed under a name not among this hull’s recorded names (not shown)
WCX9599MMSI 367337190 · cancelled · compulsorily equipped · granted 12 February 2008, cancelled 14 May 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 35

29 July 2025 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8191263
14 August 2024 Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7979534
30 May 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7922771
4 May 2023 COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7675384
10 August 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7524992
17 May 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7452923
28 May 2021 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7195834
10 July 2020 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6979182
8 May 2020 Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6950211
31 July 2019 Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6755541
29 November 2017 Internal Structural Exam · COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6314642
12 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6286272
3 March 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5831071
29 February 2016 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5824571
9 January 2012 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4221645
2 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200591
29 August 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4130039
29 March 2010 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3704731
30 March 2009 Re-Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3442796
14 February 2008 Internal Structural Exam · Examination of Repairs · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3147352
8 February 2006 Hull Examination · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2581098
2 May 2005 Re-Inspection · MTSA/ISPS Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2344862
4 April 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2326067
12 September 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2200256
1 September 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2183559
5 February 2004 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1999893
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972097
2 May 2002 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1611792
27 March 2002 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1597876
8 February 2001 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1361951
29 February 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429299
7 April 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408282
5 August 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 488891
18 May 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 511382
26 February 1998 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364660

Deficiency record · 31

18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 July 2025 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Vessel did not have records available at time of inspection. 46 CFR 16.260(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2025
Resolved 12 August 2025
Resolution: Documentation provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 July 2025 No resolution recorded
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Charts on board the vessel were 2021. 46 CFR 184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2025 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 July 2025 No resolution recorded
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection and operation of all watertight closures in the hull, decks, and bulkheads including through hull fittings and sea valve. All watertight doors need adjustment and chalk tested. 46 CFR 176.802 (a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 July 2025 Resolved
The owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of piping, controls, and valves for each fixed gas fire extinguishing system to determine that the system is in operating condition. Observed the pressure relief valve installed on the CO2 distribution manifold is to be past its test date and vessel could not show the last maintenance on the fire detection and control system. 46 CFR 176.810 (a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2025
Resolved 12 August 2025
Resolution: Servicing and testing provided for CO2 system and portable extinguishers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2025 No resolution recorded
f your vessel's Certificate of Inspection is renewed less often than annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, twice every 5 years. No more than 3 years may elapse between any check and its immediate predecessor. Observed the pressure relief valves on both air receivers did not have a tag indicating a pressure test date. Vessel operator could not provide documentation of servicing. 46 CFR 61.10-5(i)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2025 Resolved
Each generator shall be provided with a nameplate giving the manufacturer’s name, the rated frequency, the number of phases, the normal volts and amperes, the rated rpms and the rated ambient temperature or rated temperature rise. Nameplate data on both port and starboard generators could not be read. 46 CFR 183.320(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2025
Resolved 12 August 2025
Resolution: New data plates have been ordered and receipt provided.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 August 2024 Resolved
Fire detection and extinguishing system. Fire detection and extinguishing systems must be installed in compliance with 181.400 through 181.420 of this chapter. Fire detection system will not keep back-up batteries charged. Vessel must trouble shoot system. 177.410(c)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2024
Resolution: Allied attended and repaired the fixed detection system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 August 2024 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weather- tight... Weather-tight hatches leading to the main deck has a hole at the lower hinge side. Weather-tight hatch leading to storage compartment has broken wedge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2024
Resolution: Door was reparied by welding to be weathertight.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 14 August 2024 Resolved
Each vessel certificated to operate on an oceans route in warm water must be provided with life floats of aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Vessel is authorized to carry a total of 64 passengers. Life float capacity is 63. 180.202(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2024
Resolution: COI was amended to reflect 62 passengers.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 14 August 2024 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment,...not covered by standards in this subchapter may be inspected with standards acceptable to the cognizant OCMI as good marine practice. Excessive oil residue has accumulated in the exhaust causing a potential fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2024
Resolution: Engine room electrical was cleaned up.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 August 2024 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. 46 CFR 181.405(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2024
Resolved 16 September 2024
Resolution: Fixed interconnected fire detection system was installed by Allied. Witnessed satisfactory testing.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 August 2022 Resolved
On a vessel of not more than 19.8 meters (65') in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65') in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) out the pump outlet. Vessel's fire pump failed to prime and unable to produce a stream.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2022
Resolution: Vessel operator energized fire pump and was able to produce 80psi to the fire hose.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 August 2022 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB installed to automatically float free and activate. Vessel's EPIRB battery had expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2022
Resolution: Vessel purchased a new EPIRB and verified registration.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 10 August 2022 Resolved
A vessel with a power driven main steering gear must be provided with an independent rudder angle indicator at the operating stations. Vessels rudder angle indicator was not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2022
Resolved 19 August 2022
Resolution: Vessel purchase new rudder indicator and conducted a satisfactory test.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 August 2022 Resolved
The inspection and maintenance of the equipment listed shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel was unable to provide inspection documentation for all life saving equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2022
Resolved 19 August 2022
Resolution: Verified vessel has started to document all records.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 July 2020 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. A few of the life float lights do not work. Prove proper operation of the lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2020
Resolved 13 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 July 2020 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Several of the life float paddles are cracked. Replace cracked paddles.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2020
Resolved 13 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. There are some dead end wires under the helm/nav panel that need to be removed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 13 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 July 2020 Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers. There are not spacers between 4 of the life floats. Provide spacers as required.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 15 July 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2020 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. The portable fire extinguisher in the vicinity of the main deck entrance to the house could not be removed form it's bracket. The bracket was adjusted and tested sat.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 July 2020
Resolved 10 July 2020
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 3 March 2016 Resolved
rudder did not progress from 35 ot 35 degrees. closer examination in stern stering compartment showed that it was not coming close to the stop on one side and banging it on the other. required them to prove satisfactory operations of steering system within 7 days.
Due 10 March 2016
Resolved 15 March 2016
Resolution: cleared via reciept of Third party service invoice.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 3 March 2016 Resolved
diesel engine/ redgear mounts were cracked, required vessel rep to repair the mount within 7 days.
Due 10 March 2016
Resolved 11 March 2016
Resolution: cleare via pictures of satisfactory engine mount welds.
Lifesaving › Lifefloat › Lifeline
Issued 3 March 2016 Resolved
requried vessel rep to replace dry rotted floating line lights.
Due 10 March 2016
Resolved 11 March 2016
Resolution: cleared via picture of newly installed floating light lines
Fire Fighting › Portable Foam Applicators › General
Issued 3 March 2016 Resolved
foam eductor would not suck down the test bucket or put out foam. required vessel rep to prove satisfactory operation of the eductor prior to carrying portable tanks.
Action required: 705 - Other - as specified
Due 3 April 2016
Resolved 11 March 2016
Resolution: cleared via youtube video of sat operation here:https://www.youtube.com/watch?v=dw89ZziwqWA&feature=youtu.be
Engineering › Compressed Air System (start air) › Piping
Issued 3 March 2016 Resolved
pressure vessel gauges missing. required vessel rep to provide a gauge for each pressure vesel.
Due 10 March 2016
Resolved 11 March 2016
Resolution: cleared via picture of new installation.
Communications › Radio Communications › EPIRB
Issued 3 March 2016 Resolved
vessel did not have epirb onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2016
Resolution: cleared via reciept of new EPIRB registration info.
Engineering › Pressure Vessel › Relief Valve
Issued 29 August 2011 Resolved
Relief valves on both pressure vessels are not working properly.
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 31 August 2011
Resolution: Replace Relief Valves.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Eductor
Issued 29 August 2011 Resolved
Portable tank endorsement invalid until foam eductor operates properly. Replace eductor or show proper operation of eductor.
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 31 August 2011
Resolution: Replace eductor.
Construction/Loadline › Hull
Issued 27 March 2002 Resolved
Two inserts on vessel: 1) 3'x5' port stern in rudder room; 2) 4'x5' stbd sideshell in lavatory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2002
Resolution: Inserts inserted.
Fire Fighting
Issued 7 April 1999 Resolved
FIRE DETECTION SYSTEM COULD NOT BE TESTED. PERSONNEL DID NOT KNOW PRECEDURES TO TEST SYSTEM.
Condition: Unknown
Due 20 April 1999
Resolved 20 April 1999
Construction/Loadline
Issued 7 April 1999 Resolved
SUPPORT BRACKETS, (2) FIRE MAIN PIPES, (1) PORT INBOARD M/E RAW WATER PIPE,BROKE AT THE WELD TO THE PIPE.
Condition: Unknown
Due 20 April 1999
Resolved 20 April 1999

Casualty record · 1

12 September 2004Routine · role: Involved in a Marine Casualty · 1 injured · activity 2200256
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MADDEN TIDE (2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.