Records from 1998 to 2017. Most recent: inspection, 19 December 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Navigation › Piloting/Steering › Azimuth
Issued 26 February 2010
Resolved
Verify final installation and conduct full operational tests of the Dynamic Positioning Systems (DPS-1). Test to be witness by USCG prior to vessel returning to normal operations
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2010
Resolution: ABS witnessed u/w tests of the DPS
Engineering › Thrusters › Shaft
Issued 26 February 2010
Resolved
Provide documentation to address the 3 questions raised by MSCs DPS-1 approval letter. Prior to operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2010
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 26 February 2010
Resolved
Provide updated Fire and Safety Plan and submit to USCG approval. 90 days.
Action required: 705 - Other - as specified
Due 22 June 2010
Resolved 16 June 2010
Resolution: Vsl provided updated Fire and Safety Plan. Walked entire plan and verified equipment noted on plan. Plan was approved.
Communications › Radio Communications › Satellite Communications Capability
Issued 26 February 2010
Resolved
Prove proper operation of new GMDSS installation. Prior to operations
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2010
Lifesaving › Launching Appliances › Falls
Issued 26 February 2010
Resolved
Conduct 1.1 load test of rescue boat davit after falls are end for ended.. Prior to operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2010
Engineering › Thrusters › Blade
Issued 26 February 2010
Resolved
Provide propeller inspection report and replace/repair both props as required. Prior to operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 26 February 2010
Resolved
Replace engine room CO2 time delay and conduct proper testing. Prior to operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 26 February 2010
Resolved
Replace/repair bow thruster CO2 remote pull activation cable. Prior to operations
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2010
Lifesaving › Rescue Boat › Propulsion Engine
Issued 3 February 2010
Resolved
Make rescue boat motor operational prior to sailing (fuel filter inoperative).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2010
Resolution: Corrected prior to departing the port, verified.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 3 February 2010
Resolved
Provide flash gear (NOMEX hoods) for fire fighting ensembles (2 sets). Recevied email report from master dtd 3/26/10 that "One (NOMEX hood)flash gear have been placed in the left jacket pocket of of each fire fighting ensemble (2 sets)." Left def open until next inspection.
Condition: Unknown
Due 4 May 2011
Resolved 10 June 2010
Resolution: Vessel provided 02 flash hoods for fire suits.
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 3 February 2010
Resolved
Provide flange shielding in fuel/transfer distribution piping side of pumps and centrifuge in accordance with SOLAS 74 (amended) Reg II-2/4.2.2.5.3. Receieved email concerning correction. Left open to verify at next inspection.
Condition: Improper Installation
Due 4 May 2011
Resolved 10 June 2010
Resolution: Vessel provided proper repair to flanges in the fuel transfer pump.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 3 February 2010
Resolved
Supply proof of any oil and cargo (OBM) transfer hose onboard have been hydrostatically tested to 1.5x MAWP or remove from vessel. Email from master 3/26/10: "3 new fuel oil transfer hoses were received. Each hose has been pressure tested with test certificates filed aboard. OBM cargo transfer hose was condemned and discarded. 2 new OBM hoses are on order. " left def open to next insp.
Condition: Improper/Lack of Maintenance
Due 4 May 2011
Resolved 10 June 2010
Resolution: Vessel provided hose test records for OBM hoses.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 3 February 2010
Resolved
Prove oepration of generator overspeeds (port and stbd). Master reports via email that both tested sat (3/26/2010) left def open to be verified at next insp.
Condition: Improper/Lack of Maintenance
Due 4 May 2011
Resolved 10 June 2010
Resolution: Witnessed satisfactory tests of generator over speeds on both generators.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 3 February 2010
Resolved
Conduct and log CG periodic safety test procedures. Received documentation concerning completion, left open to verify ongoing performance at next inspection.
Condition: Improper/Lack of Maintenance
Due 4 May 2011
Resolved 10 June 2010
Resolution: Witnessed records of the periodic safety tests.
Engineering › Non-conventional Propulsion/Steering › Control Systems (Azipod)
Issued 3 February 2010
Resolved
Repair bridge control to shutdown port main engine. Master reports working 3/26/2010, left open to be verified at next insp.
Condition: Improper/Lack of Maintenance
Due 4 May 2011
Resolved 10 June 2010
Resolution: Witnessed satisfactory tests of bridge control shutdown for port main engine.
Accommodation/Occupational Safety › Ventilation › General
Issued 3 February 2010
Resolved
Repair engine room supply fan to operate at normal load and speed (won't function without generators in parallel). Master reports fan repaired, and oeprational at normal load on one generator (3/26/2010), left def open to next insp for verification.
Condition: Improper/Lack of Maintenance
Due 4 May 2011
Resolved 10 June 2010
Resolution: Witnessed operation of engine room supply fan at normal load on one generator.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 3 February 2010
Resolved
Remove fuel hose (to fill skid-pump) from emergency generator room.
Condition: Improper Installation
Due 4 April 2010
Resolved 10 March 2010
Resolution: Verified removed by [name withheld]
Fire Fighting › Fire Pumps › Casing
Issued 3 February 2010
Resolved
Repair pump housing (hole) on deck mounted fire monitor. Master reports repaired, 3/26/2010, left def open to be verified at next insp.
Condition: Improper/Lack of Maintenance
Due 4 May 2011
Resolved 16 June 2010
Resolution: Vsl repaired hole in pump housing on deck mounted fire monitor. Fire monitor operated satisfactory.
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 3 February 2010
Resolved
Repair gyro repeater at emergency steering station in engine room. Master reports unit has been replaced, calibrated and is functional, 3/26/2010. Left def open to next insp for verification.
Condition: Improper/Lack of Maintenance
Due 4 May 2011
Resolved 10 June 2010
Resolution: Witnessed operational gyro repeater at steeering station and engine room.
Communications › Alarms/Indicators › General Alarm
Issued 3 February 2010
Resolved
Repair general alarm sounding devices on the 01 deck and the main aft deck. Master reports repair complete and tested operational, 3/26/2010. Left def open to next insp to verify.
Condition: Improper/Lack of Maintenance
Due 4 May 2011
Resolved 10 June 2010
Resolution: Witnessed satisfactory tests of general alarm. Alarm sounded on 01 deck and aft main deck.
Documentation › Logs/Records › Drug Test Records
Issued 3 February 2010
Resolved
Complete the provided Chemical Testing Program compliance audit form (may need assistance from SEACOR HS&E coordinator).
Due 4 April 2010
Resolved 26 March 2010
Resolution: Provided. Unit DAPI auditor to determine adequacy.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 May 2009
Resolved
Proved proof of the OWS has been calibrated and is being used. Received e-mail 22Feb advising corrected and extended due date to next annual.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2010
Resolved 3 February 2010
Resolution: Replaced with new OCM with factory cal certificate. Tested sat.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 21 May 2009
Resolved
Proved proof of the Rescue boat fall being weighted tested. Received e-mail 08Feb advising corrected and extended due date to next annual.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2010
Resolved 10 March 2010
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 26 January 2009
Resolved
Proved proof of required equipment to conduct to High Jacket water and High Oil temp test as described in the manufacture maintenance. Received e-mail 11Febadvising corrected and extended due date to next annual.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2010
Resolved 3 February 2010
Resolution: Closed and re-isuued.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 26 January 2009
Resolved
Proved proof of the Engine room Gyro repeater has been repaired. Received e-mail 07Feb advising corrected and extended due date to next annual.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 February 2010
Resolved 22 February 2010
Resolution: Sat
Electrical › Lighting (service) › Lighting Fixture
Issued 26 January 2009
Resolved
Proved proof of the damaged Engine room light covers have been renewed. Received e-mail 11Feb advising corrected and extended due date to next annual.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2010
Resolved 3 February 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 April 2008
Resolved
Conduct proper servicing test of the fixed fire fighting system onboard vessel with proper manual in the presence of a USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 11 July 2008
Resolution: Permission was given by CID that Wilhelmsen Ship Service (UNITOR) could conduct servicing with out CG oversight. Servicing Report was provided and confirmation that CO2 was used was included.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 24 April 2008
Resolved
Conduct rescue boat launching appliance servicing by the manufacturer and/or manufacture’s representative
Due 1 June 2008
Resolved 11 July 2008
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 24 April 2008
Resolved
Install door closure on WTD door leading to engine compartment.
Cleared via email, to be verified at next CG attendance
Due 4 May 2009
Resolved 26 January 2009
Resolution: Sighted door
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 24 April 2008
Resolved
Replace RPM gauge on #2 SSDG.
Cleared via email, to be verified at next CG attendance
Due 4 May 2009
Resolved 26 January 2009
Resolution: Sighted gauge
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 24 April 2008
Resolved
Replace watt meter on # 1 SSDG, located on switchboard
Cleared via email, to be verified at next CG attendance
Due 4 May 2008
Resolved 26 January 2009
Resolution: sighted meter
Communications › Radio Communications › VHF Radiotelephone
Issued 2 June 2007
Resolved
Provide current Safety Radio Certificate.
Due 2 August 2007
Resolved 11 July 2007
Communications › Radio Communications › EPIRB
Issued 2 June 2007
Resolved
Provide NOAA registration sticker for EPIRB. Received email from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 4 May 2008
Resolved 24 April 2008
Fire Fighting › Fire Pumps › Pressure
Issued 2 June 2007
Resolved
Provide working pressure gauge for fire pump. Received email from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 4 May 2008
Resolved 24 April 2008
Fire Fighting › Fire Main › Valves
Issued 2 June 2007
Resolved
Provide and install new valve for fire monitor.
Due 2 August 2007
Resolved 2 June 2007
Fire Fighting › Means of Escape › Emergency Lighting
Issued 2 June 2007
Resolved
Provide working lights - emergency escape in accomodation, e/r. Received email from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 4 May 2008
Resolved 24 April 2008
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 2 June 2007
Resolved
Replace oil temperature sensor on generator. Received email from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 4 May 2008
Resolved 24 April 2008
Fire Fighting › Self-contained Breathing Apparatus › Gauge
Issued 2 June 2007
Resolved
Fill bottles for EEBDs (stbd e/r, main e/r). Received email from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 4 May 2008
Resolved 24 April 2008
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 9 April 2006
Resolved
Supply proof that the SOPEP has met the requirement for annual review. Report cleared via E-mail 07 Jun, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 2 June 2007
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 9 April 2006
Resolved
Provide proof that the onboard fuel hoses have met the requirement for annual hydrostatic testing. Report cleared via E-mail 07 Jun, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 2 June 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 9 April 2006
Resolved
All onboard portable fire fighting equipment is to be DOT approved. Report cleared via E-mail 07 Jun, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 2 June 2007
Communications › Radio Communications › EPIRB
Issued 9 April 2006
Resolved
Renew EPIRB antenna. Report cleared via E-mail 07 Jun, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 9 April 2006
Communications › Internal Communications System › Sound-powered Telephone
Issued 4 February 2005
Resolved
Prove proper operation of sound powered phone system (extremely faint).
Due 4 April 2005
Resolved 29 March 2005
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 4 February 2005
Resolved
Prove proper operation of emergency escape handle in walk in refrigerator.
Due 4 April 2005
Resolved 29 March 2005
Construction/Loadline › Penetrations › Gasket
Issued 4 February 2005
Resolved
Repair or replace gaskets to chain locker hatches.
Due 4 April 2005
Resolved 16 April 2005
Fire Fighting › Structural - A Class Divisions › Doors
Issued 4 February 2005
Resolved
Repair or replace engine room starboard side escape door.
Due 4 April 2005
Resolved 29 March 2005
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 4 February 2005
Resolved
Install missing bolts in dry bulk access cover on main deck forward.
Due 4 April 2005
Resolved 29 March 2005
Lifesaving › Rescue Boat › Construction
Issued 4 February 2005
Resolved
Make permanent repairs to fast rescue boat skirt.
Due 4 April 2005
Resolved 16 April 2005
Lifesaving › Emergency Outfit › Boots
Issued 4 February 2005
Resolved
Properly hydro test and refill SCBA bottles or replace with approved CO2s.
Due 4 April 2005
Resolved 16 April 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 4 February 2005
Resolved
Weigh C02 extinguisher bottles; do not use liquid level gauging equipment.
Due 4 April 2005
Resolved 29 March 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 4 February 2005
Resolved
Properly hydro test portable CO2* and paint locker CO2 bottles at US DOT approved facility or replace with approved CO2 bottles.
Due 4 April 2005
Resolved 9 April 2006
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 4 February 2005
Resolved
Provide test equipment for automation test procedures.
Due 4 April 2005
Resolved 9 April 2006
Electrical › Electric Generation Source (service) › Panelboard
Issued 4 February 2005
Resolved
Repair or replace starboard generator tachometer.
Due 4 April 2005
Resolved 29 March 2005
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 4 February 2005
Resolved
Repair or replace starboard generator reverse power relay.
Due 4 April 2005
Resolved 9 April 2006
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 4 February 2005
Resolved
Provide battery boxes for batteries under #1 fire station.
Due 4 April 2005
Resolved 29 March 2005
Engineering › Lubricating Oil Service System › Pump
Issued 4 February 2005
Resolved
Repair leak on lube oil transfer pump.
Due 4 April 2005
Resolved 9 April 2006
Accommodation/Occupational Safety › Potable Water System › General
Issued 4 February 2005
Resolved
Replace wasted potable water pipe in way of forward potable water pump.
Due 4 April 2005
Resolved 29 March 2005
Lifesaving › Launching Appliances › Falls
Issued 4 February 2005
Resolved
End for end rescue craft falls and conduct 110% weight test (((number of persons allowed in rexcue craft X 165 pounds) + weight of FRC) X 110). Note this requirement issued administratively after review of casework.
Due 14 April 2005
Resolved 16 April 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 8 March 2004
Resolved
Make repairs to stbd MDE exhaust leak. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 April 2005
Resolved 4 December 2004
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 8 March 2004
Resolved
Conduct annual hydro test on fuel transfer hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2004
Resolved 12 March 2004
Resolution: Renewed
Engineering › Lubricating Oil Service System › Pump
Issued 8 March 2004
Resolved
Prove proper operation of both MDE low-pressure lube oil shutdowns. LEGACY COMPONENT DESC: Safety shutdown
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2005
Resolved 4 December 2004
Resolution: Corrected
Engineering › Generator (propulsion/auxiliary-electric) › Remote Control Circutry
Issued 8 March 2004
Resolved
Prove proper operation of both SSDG's overspeed and lube oil shutdowns.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2005
Resolved 4 December 2004
Resolution: Corrected
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 8 March 2004
Resolved
Prove proper operation of emergency diesel generator overspeed, low lube oil pressure and high jacket water temperature alarm. LEGACY COMPONENT DESC: Safety alarm and shutdowns
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2005
Resolved 4 December 2004
Resolution: Completed
Electrical › Electrical Distribution System (service) › Cable
Issued 8 March 2004
Resolved
Removed dead-end cable in the P/S ACM battery charger.
Condition: Improper Installation
Due 22 March 2004
Resolved 12 March 2004
Personnel › Certificates/Documents/Licenses › License, Master
Issued 8 March 2004
Resolved
Vessel is limited to operate no more than 200 nautical miles while master has limited near coastal license.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 12 March 2004
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 8 March 2004
Resolved
Provide updated SOLAS Training Manual.
Condition: Unknown
Due 22 March 2004
Resolved 12 March 2004
Navigation › Collision/Grounding Avoidance › Radar
Issued 8 March 2004
Resolved
Prove proper operation of STBD radar. If PORT radar fails, vessel is to return to the pier and wait until both radars are repaired.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 April 2005
Resolved 4 December 2004
Resolution: Corrected
Communications › Internal Communications System › Portable Radios
Issued 8 March 2004
Resolved
Provide Public Address system intewrnally, iaw 46 CFR 133.60c LEGACY COMPONENT DESC: Public Address System
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 April 2005
Resolved 4 December 2004
Resolution: Corrected
Fire Fighting › Self-contained Breathing Apparatus › Air Supply (minutes)
Issued 8 March 2004
Resolved
Recharge Scott Air (EEBD) iwo officers berthing focsle deck.
Condition: Improper/Lack of Maintenance
Due 15 March 2004
Resolved 12 March 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 March 2004
Resolved
Update first-aid kit iwo galley. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 15 March 2004
Resolved 12 March 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 8 March 2004
Resolved
Update emergency eye-wash station in the galley. LEGACY COMPONENT DESC: Emergency Eye-wash station
Condition: Improper/Lack of Maintenance
Due 15 March 2004
Resolved 12 March 2004
Lifesaving › Launching Appliances › Davit
Issued 8 March 2004
Resolved
Make repairs to lifeboat davits hydraulic leak.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 April 2005
Resolved 4 December 2004
Resolution: Corrected
Lifesaving › Rescue Boat › Rubbing Strips
Issued 8 March 2004
Resolved
Replace blocks on rescue boat davit. LEGACY COMPONENT DESC: Davit Blocks
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2005
Resolved 4 December 2004
Resolution: Corrected
Communications › Alarms/Indicators › Fire Alarm
Issued 8 March 2004
Resolved
Prove proper operation of fire alarm in the galley.
Condition: Unknown
Due 15 March 2004
Resolved 12 March 2004
Navigation › Piloting/Steering
Issued 22 March 2003
Resolved
Provide updated deviation table. LEGACY COMPONENT DESC: Deviation Table/Graph
Due 22 April 2003
Resolved 13 April 2003
Lifesaving › Hand Flares
Issued 22 March 2003
Resolved
Replace unapproved hand Flares with USCG approved Flares. 12 Total
Due 22 April 2003
Resolved 15 April 2003
Fire Fighting › Fixed Fire Detection System
Issued 22 March 2003
Resolved
Repair faulty clear procedures for fire detection system. LEGACY COMPONENT DESC: Detector/Call Point Grouping
Due 22 April 2003
Resolved 24 March 2003
Lifesaving › Line-Throwing Appliances
Issued 22 March 2003
Resolved
Provide line throwing apparatus messenger line. LEGACY COMPONENT DESC: Lines
Due 22 April 2003
Resolved 11 April 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 22 March 2003
Resolved
Repair CO2 extinguisher brackets on bottle for paint locker. LEGACY COMPONENT DESC: Bracket
Due 22 April 2003
Resolved 25 April 2003
Fire Fighting › Means of Escape
Issued 22 March 2003
Resolved
Repair automatic closing device for the following doors; Engine room port side aft & engine room access from main deck. LEGACY COMPONENT DESC: Doorways
Due 22 April 2003
Resolved 15 May 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2002
Resolved
REMOVE ALL EXTENSION CORDS SERVING AS PERMANENT WIRING IN CREW QUARTERS.
Condition: Improper Installation
Due 1 May 2002
Resolved 1 May 2002
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 1 May 2002
Resolved
INSTALL NEW FLAME SCREEN IN THE STBD SIDE AFT FUEL OIL VENT
Condition: Improper/Lack of Maintenance
Due 1 May 2002
Resolved 1 May 2002
Engineering › Fuel Oil Service System › Hose
Issued 1 May 2002
Resolved
INSTALL CHAFING GEAR ON THE F/O SERVICE HOSES FOR THE EMERGENCY GENERATOR.
Condition: Improper/Lack of Maintenance
Due 1 May 2002
Resolved 1 May 2002
Lifesaving › Line-Throwing Appliances › Instructions/Diagrams
Issued 1 May 2002
Resolved
PROVIDE PROPER LINE THROWING APPLIANCE FOR INTERNATIONAL VOYAGE.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Lifesaving › Inflatable Liferafts › Markings
Issued 1 May 2002
Resolved
PROVIDE AND POST VESSEL SPECIFIC LIFERAFT LAUNCHING INSTRUCTIONS.
Condition: Improper Installation
Due 1 May 2002
Resolved 1 May 2002
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 23 April 2002
Resolved
PROVIDE AND INSTALL DATED BATTERIES IN ENGINE ROOM AND 01 LEVEL LIFE PRESERVERS.
Condition: Improper/Lack of Maintenance
Due 1 May 2002
Resolved 1 May 2002
Construction/Loadline › Structures › Door
Issued 23 April 2002
Resolved
PROPERLY ADJUST WATERTIGHT DOORS ON THE MAIN DECK AND BELOW
Condition: Improper/Lack of Maintenance
Due 1 May 2002
Resolved 1 May 2002
Engineering
Issued 3 June 1999
Resolved
Demonstrate proper operation of engineering and fire detection automation system to the satisfation of the attending marine inspector.
Condition: Unknown
Due 3 July 1999
Resolved 29 August 1999
Documentation
Issued 6 April 1998
Resolved
PROVIDE ON BOARD VESSEL MAINTENANCE/OPERATION INSTRUCTION MANUAL FOR FIRE FIGHTING AND FIRE CONTAINMENT EQUIPMENT IN ACCORDANCE WITH SOLAS 74(AMENDED) II-2/20.
Condition: Unknown
Due 15 April 1998
Resolved 23 July 1998
Documentation
Issued 6 April 1998
Resolved
PROVIDE ON BOARD VESSEL TRAINING MANUAL FOR LIFESAVING ALPPLIANCES IN ACCORDANCE WITH SOLAS 74(AMENDED) III/18.2,51.
Condition: Unknown
Due 15 April 1998
Resolved 23 July 1998
Documentation
Issued 6 April 1998
Resolved
PROVIDE ON BOARD VESSEL INSTRUCTIONS FOR MAINTENANCE OF LIFESAVING APPLIANCES IN ACCORDANCE WITH SOLAS 74(AMENDED) III/19.3,52.
Condition: Unknown
Due 15 April 1998
Resolved 23 July 1998
Documentation
Issued 6 April 1998
Resolved
PROVIDE/POST EMERGENCY INSTRUCTIONS ON BOARD VESSEL IN ACCORDANCE WITH 46 CFR 131.330/340.
Condition: Unknown
Due 15 April 1998
Resolved 23 July 1998
Fire Fighting
Issued 6 April 1998
Resolved
PROVIDE ON BOARD VESSEL ONE (1) 20 LITER FOAM FIRE EXTINGUISHER AND ONE (1)SPARE FOAM IN ENGINE ROOM IN ACCORDANCE WITH SOLAS 74(AMENDED) II-2/
Condition: Unknown
Due 15 April 1998
Resolved 23 July 1998
Documentation
Issued 6 April 1998
Resolved
APPROVAL LETTER AND STAMPED APPROVED FIRE CONTROL AND LIFESAVINFG PLANS NOTON BOARD VESSEL.
Condition: Unknown
Due 6 July 1998
Resolved 23 July 1998
Fire Fighting
Issued 6 April 1998
Resolved
PROVIDE A SELF CLOSING FIRE DOOR BETWEEN MAIN AND EMERGENCY FIRE PUMPS IN ENGINE ROOM PRIOR TO VESSEL SAILING ON AN INTERNATIONAL VOYAGE IN ACCORDANCE WITH SOLAS 74(AMENDED) II-2/47.1; REFERENCE G-MSC LTR DATED 10SEP98.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Documentation
Issued 6 April 1998
Resolved
PROVIDE ON BOARD VESSEL THE FCC CERTIFICATE FOR RADIO STATION LICENSE.
Condition: Unknown
Due 15 April 1998
Resolved 23 July 1998
Documentation
Issued 6 April 1998
Resolved
PROVIDE/POST MUSTER LIST PILOT HOUSE, ENGINE ROOM, ACCOMMODATION PASSAGE_x001C_ IN ACCORDANCE WITH 46 CFR 1
Condition: Unknown
Due 15 April 1998
Resolved 23 July 1998
Deck/Cargo
Issued 6 April 1998
Resolved
PRIOR TO CARRYING NOXIOUS LIQUID SUBSTANCES (NLS) ON AN INTERNATIONAL VOYAGE, OBTAIN AUTHORIZATON FROM COAST GUARD MARINE SAFETY CENTER.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Unknown
Issued 6 April 1998
Resolved
PROVIDE TO ATTENDING MARINE INSPECTOR FOR REVIEW VESSEL'S OFFICERS' LICENSES.
Condition: Unknown
Due 15 April 1998
Resolved 23 July 1998
Documentation
Issued 6 April 1998
Resolved
APPROVAL LETTER AND STAMPED APPROVED FOR PERIODIC SAFETY TEST PROCEDURES ONON BOARD.
Condition: Unknown
Due 15 April 1998
Resolved 23 July 1998
Unknown
Issued 6 April 1998
Resolved
PROVIDE ON BOARD VESSEL LETTER AND STAMPED "EXAMINED" COPY OF OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 15 April 1998
Resolved 23 July 1998
Unknown
Issued 6 April 1998
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF GMDSS SYSTEMS.
Condition: Unknown
Due 15 April 1998
Resolved 23 July 1998
Unknown
Issued 6 April 1998
Resolved
PERFORM SATISFACTORY ABANDON SHIP AND MAN OVERBOARD DRILL TO SATISFACTION OF ATTENDING CG INSPECTOR IAW SOLAS 74(AMENDED) III/18.3.4-3.9.
Condition: Unknown
Due 15 April 1998
Resolved 23 July 1998
Unknown
Issued 6 April 1998
Resolved
PERFORM SATISFACTORY FIRE DRILL IN ACCORDANCE WITH SOLAS 74(AMENDED) III/18.3.10-3.13.
Condition: Unknown
Due 15 April 1998
Resolved 23 July 1998