Records from 1980 to 2010. Most recent: inspection, 10 December 2010.
Documentation record
Registered dimensions (L × B × D)41.9 ft × 14.6 ft × 6.0 ft
Registered tonnagegross 22 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderT CRAFT BOAT CO INC · TITUSVILLE, FL, UNITED STATES · built 1971
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFULTON, TX
Trade endorsementsFishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
10 December 2010
Type not recorded
No type recorded · CGC AMBERJACK (WPB-87315) · USCG Northeast District (CGD-NE) · Activity 3913630
11 March 2008
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 3162677
29 June 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2977646
23 June 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2974435
22 June 2007
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 3015125
6 February 1995
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 838207
1 July 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 847602
7 May 1992
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1264045
20 February 1992
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1426710
13 June 1991
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1325507
30 April 1991
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 903431
29 November 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 924582
22 October 1990
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1216278
26 April 1990
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1229734
3 May 1989
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1041686
2 November 1988
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 890272
25 March 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1299733
2 March 1988
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1335289
30 April 1987
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1320932
4 June 1986
Credit Drydock
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 986707
15 May 1986
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 992594
8 May 1986
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1294082
16 May 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 981141
7 May 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1290599
8 May 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281922
8 May 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281925
5 May 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973397
5 May 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1273117
12 April 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1275698
17 May 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1275065
11 August 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1273632
22 May 1980
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1273349
Lifesaving
Issued 7 May 1992
Resolved
PROVIDE ON BOARD VESSEL AN APPROVED PERSONAL FLOATATION JACKET FOR A TOTAL OF 22, VESSEL IS RESTRICTED TO A TOTAL OF 21 PERSONS ON BOARD TILL REQUIREDNUMBER OF FLOATATION JACKETS ARE ON BOARD._x001C_ _x001C_
Condition: Unknown
Due 22 May 1992
Resolved 5 June 1992
Construction/Loadline
Issued 30 April 1991
Resolved
MAKE REPAIRS TO PORT ENGINE SHAFT FIBERGLASS HOUSING.
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Construction/Loadline
Issued 30 April 1991
Resolved
MAKE FIBERGLASS REPAIRS TO STARBOARD SIDE HULL IN FORWARD PEAK COMPARTMENT.
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Lifesaving
Issued 30 April 1991
Resolved
PROVIDE (1) ONE ADDITIONAL ADULT LIFE JACKET FOR A TOTAL OF 22 ADULT JACKETS.
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Lifesaving
Issued 30 April 1991
Resolved
PROVIDE (4) FOUR RED EMERGENCY DISTRESS SIGNAL FLARES.
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Lifesaving
Issued 30 April 1991
Resolved
MOUNT AND CONNECT SEA PAINTER
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Construction/Loadline
Issued 30 April 1991
Resolved
EMPTY AND REPAIR FIBERGLASS CRACK ON STARDBOARD SIDE FUEL TANK LEAK AND HYDRO TEST.
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Navigation
Issued 22 October 1990
Resolved
REPAIR/RENEW HORN AND PROVE OPERATION.
Condition: Unknown
Due 22 October 1990
Resolved 22 October 1990
Navigation
Issued 22 October 1990
Resolved
REPAIR/REMOVE SEARCHLIGHT.
Condition: Unknown
Due 22 October 1990
Resolved 22 October 1990
Lifesaving
Issued 22 October 1990
Resolved
MAKE PERMANENT REPAIRS TO FWD LIFE FLOAT RETAINER STAND.
Condition: Unknown
Due 22 October 1990
Resolved 22 October 1990
Navigation
Issued 22 October 1990
Resolved
MAKE PERMANENT REPAIRS TO STEERING SYSTEM.
Condition: Unknown
Due 22 October 1990
Resolved 22 October 1990
Lifesaving
Issued 22 October 1990
Resolved
INSTALL RETROFLECTIVE TAPE ON BOTH LIFE FLOATS. (REF NVIC 1-87)
Condition: Unknown
Due 22 October 1990
Resolved 22 October 1990
Electrical
Issued 22 October 1990
Resolved
REMOVE WIRE NUTS FROM ENGINE AND ELECTRONIC EQUIPMENT WIRING.
Condition: Unknown
Due 22 October 1990
Resolved 22 October 1990
Lifesaving
Issued 22 October 1990
Resolved
INSTALL WEAK LINK ON LIFE FLOAT SEA PAINTER LINE WITH OTHER END SECURED TO VESSEL.
Condition: Unknown
Due 22 October 1990
Resolved 22 October 1990
Accommodation/Occupational Safety
Issued 22 October 1990
Resolved
TIGHTEN-UP LOOSE HAND RAILS/SOCKETS & RENEW BENT RAIL D& BROKEN SOCKET.
Condition: Unknown
Due 22 October 1990
Resolved 22 October 1990
Engineering
Issued 22 October 1990
Resolved
REMOVE EXCESS GEAR OIL FROM BILGES AND REPAIR OIL LEAK ON PORT MARINE GEAR
Condition: Unknown
Due 22 October 1990
Resolved 22 October 1990
Navigation
Issued 22 October 1990
Resolved
INSTALL BULBS OF PROPER HEIGHT IN P&S RUNNING LIGHTS.
Condition: Unknown
Due 22 October 1990
Resolved 22 October 1990
Navigation
Issued 22 October 1990
Resolved
REPAIR/RENEW FATHOMETER & PROVE PROPER OPERATION.
Condition: Unknown
Due 22 October 1990
Resolved 22 October 1990
Documentation
Issued 2 March 1988
Resolved
PROVIDE VALID FCC RADIO STATION LICENSE ON BOARD VESSEL.
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Engineering
Issued 2 March 1988
Resolved
REPAIR BOTH EMERGENCY FUEL SHUTOFF VALVES AND ENCLOSE T-HANDLES. MOUNT DECK ACCESS TOOL WITHIN EASY ACCESS.
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Navigation
Issued 8 May 1986
Resolved
REPAIR AND TEST SINGLE SIDE-BAND RADIO IN PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 8 May 1986
Resolved 8 May 1986