MAURY USCG vessel records
← All vessels

LT JOE THEINERT

Built
1997
Last inspected
13 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCY5006
468566
Flag
UNITED STATES
Maury page id
psix-468566

Documentation record

Registered dimensions (L × B × D)90.4 ft × 37.3 ft × 10.4 ft
Registered tonnagegross 72 / net 49
ITC dimensions (L × B × D)90.4 ft × 37.3 ft × 10.4 ft
ITC tonnagegross 142 / net 54
BuilderCHEASAPEAKE SHIPBLDG CORP · SALISBURY, MD, UNITED STATES · built 1997
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSHELTER ISLAND, NY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it142 - Convention (Subpart B), Gross Ton
72 - Regulatory (Subpart C or D), Gross Ton
54 - Convention (Subpart B), Net Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 21

13 April 2026 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8330244
16 December 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8284393
20 March 2025 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8096471
12 February 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7865395
2 November 2023 Administrative Inspection · Drydock Exam · Plan Review "T" Boat · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7818264
13 March 2023 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7650637
14 March 2022 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7411645
25 October 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7339499
25 March 2021 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7069431
12 February 2020 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6900331
24 October 2019 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6835400
6 February 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6583472
29 May 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6403755
10 April 2018 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6416289
5 January 2018 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6333238
25 October 2017 Damage Survey · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6272344
20 June 2017 Excursion Permit
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6182942
18 January 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6073266
22 November 2016 Damage Survey
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6046083
3 March 2016 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5826170
29 February 2016 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5823820

Deficiency record · 8

02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 20 March 2025 Resolved
On the engine room bulkhead directly below the emergency escape hatch there are a series of three or four holes approx 1" in diameter in the bottom of the bulkhead. The holes appear to be above the waterline. Issued requirement to make a temp repair so that in th event og a fire the suppresion agent would not dissipate through the holes. The holes are non-structural, and a requirement to crop and renew at next drydock has been issued on an CG-835
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2025
Resolved 16 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 March 2025 Resolved
#1 MDE fire pump guage would only read 40psi. Issued requirement for guage to read 60psi during operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2025
Resolved 2 April 2025
Resolution: Drive belt needed tension.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 February 2024 Resolved
Upon testing, bilge suction would not work. After troubleshooting the bilge pump motor required replacing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 March 2024
Resolved 14 February 2024
Resolution: Motor replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 March 2023 Resolved
PFD’s had previous vessel’s name, SOUTHER CROSS, stenciled on PFDs. 46CFR180.71(e): each life jacket carried on board the vessel must be marked in accordance with 185.604. 185.604(b): each life jacket must be marked in clearly legible block capital letters with the vessel’s name.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 March 2023
Resolved 13 March 2023
Resolution: Master had 03 crewmembers correct the VSL name on PFD’s while USCG Mis were onboard. Cleared 01 def on the spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 March 2021 Resolved
(a) Except as otherwise provided in 46 CFR 177.500, each space accessible to passengers or used by the crew on a regular basis, must have at least two means of escape. When inspecting the escape hatch for the machinery space, identified the escape hatch as tight and stiff to open. Required vessel O/O to grease or adjust the dogging bolts to maintain watertight integrity as well as allow for easy escape in case of an emergency.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 25 March 2021
Resolution: Issued 14 day requirement since the vessel's machinery space is not normally manned. The deck hatch was operational and required minimal maintenance. Prior to departing the inspection the hatch was adjusted.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 February 2020 Resolved
Service fixed fire fighting system IAW manufacturers instruction.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2020
Resolved 26 February 2020
Resolution: Received and reviewed servicing facility satisfactory servicing report for this vessel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 February 2020 Resolved
#2 steering space high water alarm is required to have visual and audible indictors, repair or replace.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2020
Resolved 12 February 2020
Resolution: Replaced indicator.
Construction/Loadline › Hull › Hull Plating
Issued 26 October 2017 Resolved
Conduct dye pen test on newly discovered gouge in hull, witnessed by the USCG prior to making repair proposal determination.
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 31 October 2017
Resolution: Completed. No fractures found