GOODTIME I

GOODTIME I is a 1971 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1985, most recently in November 2025, along with 128 deficiencies — 3 with no resolution recorded — and 2 casualty investigations between 2023 and 2025.

Records from 1985 to 2025. Most recent: inspection, 17 November 2025.

Built
1971
Last inspected
17 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD7202
Flag
UNITED STATES
367183180
Maury page id
psix-46869

Inspections, by type

…with no type recorded14
Years with a record 39 calendar years (1985–2025)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)101.2 ft × 24.0 ft × 8.5 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1971
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSANDUSKY, OH
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 8 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it64 - Regulatory (Subpart C or D), Net Ton
94 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD7202MMSI 367183180 · active · compulsorily equipped · granted 15 February 2017, expires 26 April 2027
WDC9822MMSI 367107120 · cancelled · compulsorily equipped · granted 15 April 2006, cancelled 11 April 2007
WAL6528MMSI not assigned · expired · compulsorily equipped · granted 21 March 1995, cancelled 23 July 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JOHN FRANCIS Towing Vessel · MISLE 86705 · 23 September 2023 · activity 7798571

Inspection history · 82

17 November 2025 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8269559
7 August 2025 In-Service Inspection · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8204737
5 August 2025 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8202955
26 June 2025 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8168386
26 June 2025 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8172053
2 October 2024 Administrative Inspection · COI Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8013313
2 February 2024 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7859677
29 September 2023 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7802056
23 September 2023 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7797200
23 September 2023 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7798571
25 May 2023 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7696437
26 April 2023 Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7678853
14 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7559759
19 August 2022 In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7540379
15 November 2021 Inclining Experiment
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7356557
26 July 2021 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7268139
7 July 2021 Annual Inspection · Deficiency Check · MTSA Verification · Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7247855
28 October 2020 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7085719
19 June 2020 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6953068
8 July 2019 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6742930
16 July 2018 MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6482028
12 September 2017 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6264868
21 August 2017 Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6247440
26 April 2017 Excursion Permit
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6133093
8 December 2016 MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6054628
25 July 2016 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5953257
6 May 2016 Excursion Permit
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5881117
11 November 2015 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5762078
21 May 2014 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4863086
7 May 2012 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4295047
27 October 2010 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3874677
8 July 2009 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3527936
4 May 2009 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3447304
19 November 2008 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3366095
24 April 2008 Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3190630
21 June 2007 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2969059
23 April 2007 Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2913759
6 September 2006 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2770636
22 June 2006 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2687761
18 May 2006 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2652770
5 October 2005 Hull Examination
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2508379
4 May 2005 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2348870
29 October 2004 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2230899
15 October 2004 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2223321
27 June 2004 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2141182
26 June 2004 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2141266
16 June 2004 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2100593
1 June 2004 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2099124
28 May 2004 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2080578
8 August 2003 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1889096
22 May 2003 Periodic Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1808613
21 October 2002 Excursion Permit
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1693411
23 May 2002 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1645320
17 May 2001 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1437906
12 October 2000 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1448178
17 May 2000 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1397431
28 May 1999 Re-Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1446811
4 August 1998 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 794913
14 July 1998 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1128253
28 April 1998 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1447827
20 May 1997 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1388278
7 May 1996 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1083077
9 May 1995 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1412801
9 May 1994 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1459098
11 May 1993 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 834044
12 April 1993 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1149821
18 May 1992 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 951633
13 May 1991 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 903465
8 August 1990 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 924262
17 May 1990 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 912179
15 June 1989 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1205314
24 May 1989 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1340641
26 May 1988 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 886580
24 November 1987 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1026273
13 November 1987 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1022824
5 November 1987 Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1329070
29 October 1987 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1018953
18 October 1987 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1026270
28 May 1987 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1333242
29 May 1986 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 989431
14 May 1986 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1296028
11 July 1985 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 984623

Deficiency record · 128

11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 August 2025 No resolution recorded
For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition. Vessel has two buoyant apparatus installed that were manufactured in 2021. Vessel is required to replace buoyant apparatus with life floats approved under approval series 160.027 prior to 2026 operating season.
Condition: Invalid
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 June 2025 No resolution recorded
Drydock examinations in excess of the periodic examinations required may be of the same scope; a periodic examination shall include the propellers and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Each propeller has damage; replace each propeller at next scheduled drydock inspection so vessel is in a satisfactory condition for the service intended.
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 June 2025 No resolution recorded
Drydock examinations in excess of the periodic examinations required may be of the same scope; a periodic examination shall include the underwater hull and appendages and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Multiple insets on the port bow in the vicinity of the FWD hold compartment were discovered. Make necessary repairs at next scheduled drydock inspection so vessel is in a satisfactory condition for the service intended.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 June 2025 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. For items not covered by standards in this subchapter, inspections shall be in accordance with standards acceptable to the cognizant Officer in Charge, Marine Inspections, as good marine practice. In the application of inspection standards due consideration will be given to the hazards involved in the operation permitted by a vessel's Certificate of Inspection. Thus, the standards may vary in accordance with the vessel's area of operation or any other operational restrictions or limitations. Vessel ran aground near Ballast Island. Vessel's current material condition has not been verified and will require a damage survey by a Coast Guard Marine Inspector from the local OCMI prior to being authorized to operate in a commercial status. Vessel is not authorized to carry any passengers until authorized to do so by the local OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2025
Resolution: Marine Inspector witnessed sea trials aboard vessel, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 October 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Two(2) of the lifefloats on board the vessel are deteriorated to the point they are no longer serviceable. Additionally, some of the other lifefloats required further inspection to ensure they are still serviceable. Vessel shall replaced the two deteriorated lifefloats and have the other remaining lifefloats (6) removed from their stowage position so they can be further inspected by a CG marine inspector. Vessel's passenger capability has been reduced to two-hundred and sixty-four (264) passengers until the vessel receives the two new lifefloats that have been purchased and the stowage has been verified by a CG marine inspector. 46 CFR 180.175
Action required: 705 - Other - as specified
Resolved 5 August 2025
Resolution: Lifefloats inspected. See narrative.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 October 2024 Resolved
Each paddle must be of at least 1,220 millimiters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Some life float paddles are below four (4) feet in length. Replaced paddles that do not meet this criteria. 46 CFR 180.175(f)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2024
Resolved 5 August 2025
Resolution: All paddles SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 October 2024 Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 4 feet high. When stowed in tiers, the separate units must be kept apart by spacers. No spacers were installed to separate life floats. 46 CFR 180.137(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2024
Resolved 5 August 2025
Resolution: Spacers installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2024 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Propeller shafts and front starboard engine do not have guards to protect personnel. Installed a means to protect personnel from rotating machinery by April 2025. 46 CFR 177.35-15
Action required: 705 - Other - as specified
Resolved 5 August 2025
Resolution: Rails were installed inboard of each shaft.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 October 2024 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Exhaust and overhead bulkhead in the engine room is missing required insulation. Installed removed insulation to original condition. 46 CFR 177.10-5
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2025
Resolution: Insulation installed over exhaust and in overhead over generator and MDE where it had been missing.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 October 2024 Resolved
A proper certificate issued by the Federal Communications Commission shall be regarded as evidence that the radio installation, if any, is in compliance with the requirements of that agency. Vessel did not have a certificate on board. 46 CFR 184.25-1(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2024
Resolved 4 October 2024
Resolution: Certificate was on board during drills
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 October 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2024
Resolution: Conducted COI renewal.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 September 2023 Resolved
The main steering gear and rudder stock must be of adequate strength for and capable of steering the vessel at maximum ahead service speed. Vessel experienced loss of steering. Necessary repairs must be made to steering system prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2023
Resolved 29 September 2023
Resolution: Repairs made to steering gear system, all sat.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 September 2022 Resolved
High Level Float switch did not illuminate light in pilot house upon activation. Replace or properly repair bilge high water level float switch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2022
Resolved 16 September 2022
Resolution: Tested switch and witnessed audible and visual alarm in pilot house.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 13 April 2021 Resolved
The freshwater line that supplies water to the vessel toilets is wasted and holed in way of the #5 WTB in the exhaust piping space just forward of the sewage waste tank and steering space. Toilets are unable to receive fresh water for flushing. Make permanent repair to fresh water line to the satisfaction of the attending Coast Guard Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2021
Resolution: Vessel made repairs to raw water line supplying toilets as required.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 13 April 2021 Resolved
The sewage tank vent line on the port side of the sewage tank in steering space is wasted and holed that may cause raw sewage to leak into space. Make permanent repairs to the vent line to the satisfaction of the attending Coast Guard Marine Inspector prior to operating any sewage or waste generating equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 July 2021
Resolution: Sewage tank vent line repaired as required.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 13 April 2021 Resolved
Permanent repairs that were completed to the #5 WTB are unable to be nondestructively tested until the sewage tank vent line can be permanently repaired. Once vent line repairs are completed, conduct satisfactory nondestructive testing to the repaired #5 WTB welds in the presence of the attending Coast Guard Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2021
Resolution: NDT of repairs made in #5 tank was satisfactorily completed.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 4 December 2020 Resolved
Forward tank bulkhead that is integral to the #5 WTB is severely holed and wasted in it's entirety. Entire tank perimeter in the rudder space (all three (03) sides) is severely holed and wasted approximately 8" to 10" up from bottom plate. Viewing from the tank exterior (internal ladder wasted) the internal vessel longitudinal structural members are wasted beyond acceptance. Vessel transverse and longitudinal structural members in the rudder space surrounding and IWO the sewage tank are wasted beyond acceptance. Submit a repair proposal to crop out to good metal and renew wasted structural members and bulkheads prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: Permanent repairs satisfactory
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 4 December 2020 Resolved
In the forward hold, two sections, of athwart-ships framing, were identified to be cropped and renewed. Submit a repair proposal to crop out to good metal and renew wasted structural members prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: Final repairs satisfactory
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 December 2020 Resolved
Descale, clean, and evaluate the #5 WTB IWO Sewage tank and bottom plate, external to tank in the rudder space. Submit findings to attending Coast Guard Marine Inspector prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2021
Resolution: Results of evaluation satisfactory, no further action required.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 28 October 2020 Resolved
Due to the unknown subtraction, addition and movement of weight on board this vessel, a Dead Weight Survey is required to be conducted and the calculations provided to the OCMI and/or the Coast Guard Marine Safety Center for review and issuance of a new stability letter. This must be done prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2021
Resolved 12 July 2021
Resolution: OCMI reduced pax count per MSC recommendation until new deadweight survey can be completed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 21 August 2017 Resolved
Mount 02 fire extinguishers in Engine Room in an approved marine type bracket.
Action required: 705 - Other - as specified
Due 21 September 2017
Resolved 28 August 2017
Resolution: Brackets have been purchased and installed on vessel.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 August 2017 Resolved
Seperate adult and child size PFD's on upper deck storage in order to prevent mixing of sizes.
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 28 August 2017
Resolution: PFD's have been seperated as required.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 July 2016 Resolved
Discovered a 10" diameter welded circular insert in the collision bulkhead located on the stbd side near the top section. Insert is not welded from the fwd side (welded on aft side only). Properly weld the insert with a full penetration weld so as to ensure watertight integrity. (46CFR179.320)
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 6 September 2016
Resolution: Weld visually inspected and tested with air-lance/soapy water; all sat.
Engineering › Freshwater Generation System › Piping
Issued 25 July 2016 Resolved
There is a 2" pipe (open on both ends and unused) that penetrates the collsion bulkhead and continues into the fwd hold compartment. Properly blank off or remove pipe and ensure that collision bulkhead watertight integrity is maintained. (46CFR179.320)
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 6 September 2016
Engineering › Freshwater Generation System › Piping
Issued 25 July 2016 Resolved
There is a 1" pipe located in the stbd overhead of the fuel tank space and the engine room that has multiple soft patches throughout its length. Vessel representative believed that the pipe is associated with the potable water system and possibly no longer used. Make permanent repairs to pipe, replace, or remove. (46 182.700-.730)
Action required: 705 - Other - as specified
Due 25 October 2016
Resolved 15 August 2016
Resolution: Vessel removed rubber patches and piping was found to be in satisfactory condition. Rubber patches were being used as chaffing gear not soft patches.
Navigation › Piloting/Steering › Marine Charts
Issued 25 July 2016 Resolved
Provide adequate and up-to-date navigation charts for operational area. (46CFR184.420)
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 6 September 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 25 July 2016 Resolved
Noted multiple portable fire extinguishers that were hanging from "J-Hooks" only without proper supporting brackets as provided by the manufacturer. Provide proper mounting brackets so as to prevent unnecessary movement. (46CFR181.520)
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 15 August 2016
Resolution: Approved type mounting brackets were properly installed.
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 25 July 2016 Resolved
The portable CO2 fire extinguisher located on the port-side of the wheelhouse has a cracked/damaged sheathing on the discharge hose. Replace discharge hose or replace extinguisher. (46CFR176.810)
Due 8 August 2016
Resolved 15 August 2016
Resolution: Fire extinguisher hose was replaced and found in serviceable condition.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 25 July 2016 Resolved
The upper deck is not marked for maximum number of passengers per the stability letter. Properly mark passenger count allowed on upper deck. (46CFR185.602(g))
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 15 August 2016
Resolution: Proper passenger count for upper deck is marked on aft stairway as required.
Construction/Loadline › Structures › Door
Issued 25 July 2016 Resolved
The watertight door in the trunk leading from the main deck to the engine room does not operate or seal properly due to mis-alignment, poor condition of the mechanical components, and condition of the gasket. Demontrate operability and watertight integrity of the door upon completion of repairs and alignment. (46CFR171.113)
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 21 August 2017
Resolution: Door found to be operating correctly, new gasket installed and closing mechanism was cleaned and operates smoothly.
Lifesaving › Lifefloat › Painter
Issued 25 July 2016 Resolved
All 10 lifefloats are linked to a single painter attachment. 46CFR180.137(e) requires that the combined weight of each group of lifefloats (attached to a single painter) must not exceed 400 lbs. Re-configure lifefloat painters so that this weight restriction is not exceeded. Reference above cite for full details of painter installation procedure.
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 6 September 2016
Lifesaving › Lifefloat › Serviceable
Issued 25 July 2016 Resolved
Majority of lifefloats are in poor condition due to deterioration of the outer coverings and attached components. Provide written plan of action to address servicability through authorized repair methods and materials. Plan should include a timeline to address repairs to outer skin covering, restoration of color, and replacement of deteriorated attachments.(46CFR180.15)
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 6 September 2016
Resolution: Written plan provided by O/O includes planned repair IAW manufacturer instruction and replacement of 2 life-floats in the worst condition.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 May 2014 Resolved
Secure loose CO2 bottles (02) for soda dispenser in forward stowage compartment. 46CFR 176.830(a)
Action required: 705 - Other - as specified
Due 4 June 2014
Resolved 5 June 2014
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 May 2014 Resolved
Remove non-UL approved power strip from service; port side bar area coffee warmers. 46CFR 183.340(d)(2,3)
Action required: 705 - Other - as specified
Due 4 June 2014
Resolved 21 May 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 May 2014 Resolved
Various wire connections under center cabinet in bar area are made with wire nuts. Make permanent connections IAW 46CFR 183.340(g).
Action required: 705 - Other - as specified
Due 4 June 2014
Resolved 5 June 2014
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 May 2014 Resolved
Starting battery banks for both main engines have loose connections. Tighten IAW 46CFR 183.340(g).
Action required: 705 - Other - as specified
Due 4 June 2014
Resolved 21 May 2014
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 May 2014 Resolved
Port generator front auxiliary drives missing guard. Properly protect rotating machinery IAW 46CFR 177.960.
Action required: 705 - Other - as specified
Due 21 June 2014
Resolved 5 June 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 May 2014 Resolved
There are two cut wires at operational console. Properly dead-end or remove wires IAW 46CFR 183.340.
Action required: 705 - Other - as specified
Due 4 June 2014
Resolved 5 June 2014
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 21 May 2014 Resolved
Vessel anchor is currently unsecured and lying on forward deck. Properly secure anchor to prevent undesired movement. 46CFR 177.800(a)
Due 21 June 2014
Resolved 14 May 2015
Electrical › Electrical Distribution System (service) › Conductor
Issued 27 October 2010 Resolved
The electric 110 volt outlet located on overhead of the muffler compartment lacks strain relief at the entrance to the box, and wires are loose. Operator shall install proper strain relief.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 29 October 2010
Stability › Unintentional Flooding › General
Issued 27 October 2010 Resolved
The starboard main engine exhaust pipe has a 3/8 inch diameter hole approximately 6 inches forward of the transom in way of steering compartment. Operator shall renew exhaust pipe to like new condition in way of hole.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 29 October 2010
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 4 May 2009 Resolved
The 12 volt power supply wiring for pilothouse radio's and radar are not circuit protected. Install circuit protection IAW 46 CFR 183.05-50.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 8 July 2009
Engineering › Fuel Oil Service System › Hose
Issued 4 May 2009 Resolved
The flexible non J-1942 hose for fuel oil supply between racor filter and engine inlet needs replacement IAW 46 CFR 182.20-40.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 8 July 2009
Personnel › Training › First Aid/CPR
Issued 4 May 2009 Resolved
Provide documentation that 50% or more of crewmembers have current First aid/CPR training.
Condition: Unknown
Due 21 May 2009
Resolved 8 July 2009
Engineering › Steering Gear System › Bracket/Clamp
Issued 4 May 2009 Resolved
Make permanent repairs to port rudder stop IAW 46 CFR 182.610 (c).
Action required: 705 - Other - as specified
Due 15 June 2009
Resolved 8 July 2009
Navigation › Piloting/Steering › US Coast Pilot
Issued 24 April 2008 Resolved
Provide on board current and or updated copies of the USCG Light list, Coast Pilot, and chart. 46 CFR 185.30-20
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 19 November 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 April 2008 Resolved
Label fuel oil shut-off valves in accordance with 46 CFR 185.30-20.
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 19 November 2008
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 23 April 2007 Resolved
Replace water pump PSI gauge 0-100 from head water supply.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 20 June 2007
Resolution: Gauge has been replaced.
Electrical › Electric Supply System (service) › Battery Charger
Issued 23 April 2007 Resolved
Repair battery charger broken gauge glass.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 20 June 2007
Resolution: Gauge glass has been replaced.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 23 April 2007 Resolved
Double hose clamp raw water exhaust cooling port side overboard.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 20 June 2007
Resolution: Hose has been double clamped.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 April 2007 Resolved
Correct drug and alcohol admin issues.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 20 June 2007
Resolution: Drug program up and running, all sat.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 23 April 2007 Resolved
Replace 12 adult and 1 child lifejackets.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 21 June 2007
Resolution: Requested by the owner to drop passenger count to 350 persons.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 18 May 2006 Resolved
Repair (by authorized service facility) or replace both aft BA's
Due 22 August 2006
Resolved 6 September 2006
Resolution: Vessel has purchased two new BA''s and removed both worn items from service.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 May 2005 Resolved
Properly insulate main engines and generators dry exhaust piping with CG approved material.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Fire Fighting › Fire Pumps › Pressure
Issued 4 May 2005 Resolved
Replace pipe nipple in fire main piping system located in front of the port generator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Engineering › Fuel Oil Service System › Piping
Issued 4 May 2005 Resolved
Remove old fuel line mounted to the front of the starboard engine.
Condition: Unknown
Due 3 June 2005
Resolved 11 May 2005
Lifesaving › Lifefloat › Painter
Issued 4 May 2005 Resolved
Properly attach lifefloats to painter.
Condition: Placed in Improper Service
Due 3 June 2005
Resolved 11 May 2005
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 4 May 2005 Resolved
Repair fractured expansion tank on port generator.
Condition: Improper/Lack of Maintenance
Due 3 June 2005
Resolved 11 May 2005
Resolution: Tank area was welded.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 4 May 2005 Resolved
Remove wire nut and properly wire 24vdc shut-down on port main engine.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 4 May 2005 Resolved
Replace retro-reflective tape on 28 lifejackets.
Condition: Improper/Lack of Maintenance
Due 3 June 2005
Resolved 11 May 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 October 2004 Resolved
Remove the unauthorized charred paper backing on the generator exhaust insulation. After the previously scheduled 22OCT04 trip, carry no other passengers until both the generator and main engines exhausts are completely insulated with an CG approved blanket material from the exhaust manifold to the point of water injection. For the generator dry exhaust, insulate the entire exhaust system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2004
Resolved 22 October 2004
Resolution: Insulation on the generator with the charred paper backing has been removed for the las two trips of this year. He understands that both the generators and main engines must be insulated with CG approved material prior to carrying passengers next year.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 October 2004 Resolved
Properly insulate main engine and generator dry exhaust piping with CG approved material. This includes all couplings, flanges, and elbows.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2004
Resolved 11 May 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 June 2004 Resolved
Ensure main engine exhaust is insulated to the point where water is introduced.
Due 9 July 2004
Resolved 15 October 2004
Engineering › Bilge Water Management System
Issued 2 June 2004 Resolved
Prove proper operation of both power bilge pumps to satisfaction of attending marine inspector. LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2004
Resolved 9 June 2004
Fire Fighting › Fire Pumps
Issued 28 May 2004 Resolved
Prove proper operation of fire pump and pressure gauge. LEGACY COMPONENT DESC: Capacity
Due 4 June 2004
Resolved 5 June 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 28 May 2004 Resolved
Repair oil leaks on both main engines to satisfaction of marine insepctor.
Due 4 June 2004
Resolved 9 June 2004
Operations/Management › Drills/Instruction
Issued 28 May 2004 Resolved
Draft procedures for fire main and bilge system operation to include using each pump as back up fire or bilge pump.
Due 4 June 2004
Resolved 9 June 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 28 May 2004 Resolved
Insulate starboard generator exhaust muffler. LEGACY COMPONENT DESC: Piping (exhaust)
Due 4 June 2004
Resolved 9 June 2004
Electrical › Electrical Distribution System (service)
Issued 28 May 2004 Resolved
Remove all dead end wires and tubing from engineroom. LEGACY COMPONENT DESC: Wiring
Due 4 June 2004
Resolved 9 June 2004
Engineering › Bilge Water Management System › Piping
Issued 28 May 2004 Resolved
Clean out drain pipe in sewage tank room to allow stbd side bilge to drain to port side bilge suction.
Due 31 October 2004
Resolved 3 May 2005
Electrical › Electrical Distribution System (service)
Issued 28 May 2004 Resolved
Cover and secure stbd upper battery rack.
Due 4 June 2004
Resolved 9 June 2004
Construction/Loadline › Structures
Issued 28 May 2004 Resolved
Ensure brow ends remain flush against vessel deck and pier.
Due 4 June 2004
Resolved 9 June 2004
Electrical › Electrical Distribution System (service)
Issued 28 May 2004 Resolved
Remove dead end wires from forpeak. LEGACY COMPONENT DESC: Wiring
Due 4 June 2004
Resolved 9 June 2004
Electrical › Electrical Distribution System (service)
Issued 28 May 2004 Resolved
Remove dead end wires from 2nd deck by bar. LEGACY COMPONENT DESC: Wiring
Due 4 June 2004
Resolved 9 June 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 May 2004 Resolved
Properly wire tube lights at second deck bar. Install metal hangers every 24 inces. Remove extension cords.
Due 28 June 2004
Resolved 7 July 2004
Resolution: Lights were removed.
Electrical › Electrical Distribution System (service)
Issued 28 May 2004 Resolved
Lock air conditioner power box under forward ladder. LEGACY COMPONENT DESC: Junction Box
Due 28 June 2004
Resolved 9 June 2004
Electrical › Electrical Distribution System (service)
Issued 28 May 2004 Resolved
Properly install bridge radio wire stbd side, 2nd deck outside. LEGACY COMPONENT DESC: Wiring
Due 28 June 2004
Resolved 9 June 2004
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 28 May 2004 Resolved
Ensure garbage cans on main deck smoking area are non-combustible.
Due 28 June 2004
Resolved 7 July 2004
Stability › Weathertight Integrity
Issued 28 May 2004 Resolved
Install gaskets on hatch leading to food storage compartment.
Due 28 June 2004
Resolved 9 June 2004
Lifesaving
Issued 28 May 2004 Resolved
Label and attach paddles to lifelfloat.
Due 4 June 2004
Resolved 9 June 2004
Electrical › Electrical Distribution System (service)
Issued 28 May 2004 Resolved
Install approved electrical outlets at maindeck bar for appliances and remove extension cords. LEGACY COMPONENT DESC: Outlet Box
Due 28 June 2004
Resolved 9 June 2004
Lifesaving › Buoyant Apparatus › Serviceable
Issued 28 May 2004 Resolved
Replace three condemend BA's. Total number of persons allowed onboard is reduced to 244 including crew. Vessel is allowed to operate at full capacity with 3 borrowed BAs from the Juliet Alicia 28MAY04 only.
Due 7 July 2004
Resolved 7 July 2004
Resolution: Three new were placed in service properly labeled and outfitted.
Engineering › Bilge Water Management System › Valve
Issued 28 May 2004 Resolved
Ensure forpeak bilge valve meets the requirements of 46CFR182.25-5(d).
Due 7 July 2004
Resolved 7 July 2004
Resolution: Valve was removed from system.
Communications › Radio Communications › EPIRB
Issued 28 May 2004 Resolved
Attach current NOAA registration sticker to EPIRB.
Due 28 June 2004
Resolved 7 July 2004
Resolution: New sticker attached to EPIRB wih expires June 2006.
Accommodation/Occupational Safety › Messroom › Location
Issued 28 May 2004 Resolved
Repair broken countertop hinge, second deck stbd side.
Due 28 June 2004
Resolved 7 July 2004
Accommodation/Occupational Safety › Messroom
Issued 28 May 2004 Resolved
Remove sodapop lines for bar that are mounted on electrical lines in food storage compartment. Attach soda lines with brackets independent of electrical lines.
Due 28 June 2004
Resolved 9 June 2004
Communications › Visual Communication
Issued 28 May 2004 Resolved
Label engineroom emergency exit.
Due 28 June 2004
Resolved 9 June 2004
Operations/Management › Drills/Instruction › Safety Orientation
Issued 28 May 2004 Resolved
Post station bill as per 46CFR122.514.
Due 28 June 2004
Resolved 7 July 2004
Operations/Management › Drills/Instruction › Safety Orientation
Issued 28 May 2004 Resolved
Update emergency procedures to reflect vessel configuration as per 46CFR185.512.
Due 7 July 2004
Resolved 7 July 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 May 2004 Resolved
Replace expired first aid kit contents as per 46CFR160.041.
Due 28 June 2004
Resolved 7 July 2004
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 May 2004 Resolved
Ensure drills and survival equipment are logged.
Due 1 July 2004
Resolved 7 July 2004
Resolution: Both training and the equipment checks are currently being logged.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 May 2004 Resolved
Replace plastic zip ties with metal straps on electrical wiring in the men and womens heads.
Due 28 June 2004
Resolved 7 July 2004
Resolution: Wire ties were removed and replaced with metal clips.
Documentation › Certificates/Documents › Stability Letter
Issued 28 May 2004 Resolved
Post stability letter or provide a copy of approved letter from MSC.
Due 7 July 2004
Resolved 7 July 2004
Resolution: Copy of stability letter from D9 is hanging in pilothouse.
Lifesaving › Lifejacket/PFD (Type I)
Issued 28 May 2004 Resolved
Post lifejacket donning instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2004
Resolved 28 May 2004
Resolution: Vessel obtained good quality copies of instructions to use until the original copies were obtained.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 28 May 2004 Resolved
Ensure both main engine exhausts are insulated between the water jacketed exhaust manifold and the point where cooling water is introducted. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Placed in Improper Service
Due 9 July 2004
Resolved 15 October 2004
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 28 May 2004 Resolved
Ensure both main generator dry exhausts are propely insulated.
Condition: Placed in Improper Service
Due 9 July 2004
Resolved 15 October 2004
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 28 May 2004 Resolved
Ensure both generator exhaust system are properly insulated.
Due 9 July 2004
Resolved 15 October 2004
Engineering › Bilge Water Management System
Issued 23 May 2003 Resolved
Test all bilge suctions LEGACY COMPONENT DESC: Piping
Due 30 June 2003
Resolved 10 September 2003
Resolution: Tested operation of bilge system in all compartments.
Operations/Management › Drills/Instruction
Issued 22 May 2003 Resolved
Conduct man overboard drill.
Due 30 June 2003
Resolved 10 September 2003
Resolution: Conducted man overboard drill
Lifesaving › Buoyant Apparatus
Issued 22 May 2003 Resolved
Replace 1 - 22 person life float that is unserviceable.
Due 22 May 2003
Resolved 22 May 2003
Lifesaving › Lifebuoys
Issued 22 May 2003 Resolved
Replace ring buoy, top of aft ladder to top deck
Due 22 May 2003
Resolved 22 May 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 May 2003 Resolved
Replace 4 adult PFD
Due 22 May 2003
Resolved 22 May 2003
Engineering › Sea-water System (primary cooling)
Issued 23 May 2002 Resolved
2 inch crack on STBD Muffler. LEGACY COMPONENT DESC: exhaust system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2002
Resolution: Repair work done and hydro tested to satisfation of attending Marine Inspector.
Navigation
Issued 28 May 1999 Resolved
REPLACE AND SHOW PROPER OPERATION OF ALL AROUND ANCHOR LIGHT WITH UL 1104 MARINE NAVIGATION LIGHT IAW 46 CFR 120.420.
Condition: Unknown
Due 28 June 1999
Resolved 9 August 1999
Unknown
Issued 28 May 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 June 1999
Resolved 9 August 1999
Engineering
Issued 28 May 1999 Resolved
REPAIR EXHAUST LEAK ON PORT AND STARBOARD MAIN ENGINES IAW 46 CFR 119.430(B) TO THE SATISFACTION OF MARINE INSPECTOR.
Condition: Unknown
Due 28 June 1999
Resolved 9 August 1999
Electrical
Issued 28 May 1999 Resolved
INSTALL BELT GUARDS ON BOTH PORT AND STARBOARD AUX GENERATORS IAW 46 CFR 116.960.
Condition: Unknown
Due 28 June 1999
Resolved 9 August 1999
Lifesaving
Issued 14 July 1998 Resolved
PLACE RETRO-REFLECTIVE TAPE ON LIFE FLOATS AND LIFE RINGS
Condition: Unknown
Due 15 July 1998
Resolved 16 July 1998
Lifesaving
Issued 14 July 1998 Resolved
PASSENGER COUNT LIMITED TO 360 TOTAL PERSONS VICE 365 UNTIL 5 ADDITIONAL PFD'S ARE PLACED ON BOARD.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Engineering
Issued 20 May 1997 Resolved
RENEW STBD MDE R/G L/O LINE.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Lifesaving
Issued 20 May 1997 Resolved
INSTALL RETRO TAPE ON 03 LIFERINGS & 02 LIFEFLOATS.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Electrical
Issued 20 May 1997 Resolved
PROVE PROPER OPERATOIN OF STBD GEN ONCE INSTALLED.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Electrical
Issued 20 May 1997 Resolved
INSTALL ELECTRICAL MAT IN FRONT OF GEN SWITCH BD.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Accommodation/Occupational Safety
Issued 20 May 1997 Resolved
INSTALL METAL TRASH CANS WITH LIDS IN BOTH HEADS.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Lifesaving
Issued 7 May 1996 Resolved
TOTAL NUMBER OF ADULT PASSENGERS ALLOWED ONBOARD IS LIMITED TO 323 UNTIL 1 ADDITIONAL 20 MAN BUOYANT APPARATUS IS PLACED ONBOARD AND 38 ADULT PFD HAVEREFLECTIVE TAPE REGLUED/REPLACED AS INDICATED.
Condition: Unknown
Due 30 June 1996
Resolved 28 January 1997
Navigation
Issued 17 May 1990 Resolved
PROVE OPERATION OF RADAR
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVE PROPER OPERATION OF BOTH GENERATOR STARTERS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Engineering
Issued 17 May 1990 Resolved
PROVIDE HEAT SHIELDS FOR RAYCO FUEL FILTERS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Engineering
Issued 24 May 1989 Resolved
MAIN SEAL IN STB DETROIT DIESEL LEAKING. THIS ENGINE WAS OVERHAULED DURING THE WINTER. GREAT LAKES DIESEL WILL HAVE TO REPLACE.
Condition: Unknown
Due 24 May 1989
Resolved 24 May 1989
Fire Fighting
Issued 26 May 1988 Resolved
HAVE ONE ENGINEROOM B-II FIRE EXTINGUISHER HYDROED.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Construction/Loadline
Issued 29 October 1987 Resolved
BILGE SUCTION VALVES AND STRAINERS TO BE CLEANED AND CHECKED FOR PROPER OPERATION
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Construction/Loadline
Issued 29 October 1987 Resolved
LIQUID METAL FILLER USED TO SEAL OPENINGS IN FWD ENGINE ROOM BULKHEAD TO BE REMOVED AND SUCH PENATRATIONS MADE WATER TIGHT BY METALLIC FITTINGS WELDED , PLUGGED OR CAPPED.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Construction/Loadline
Issued 29 October 1987 Resolved
CORRECTIVE MEASURES ARE TO BE TAKEN TO CHECK CORROSIVE ACTION ON ALL INTERNAL STRENGTH MEMBERS.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Construction/Loadline
Issued 29 October 1987 Resolved
SCUTTLE COVERS TO FWD PEAK TANK AND FUEL TANK COMPARTMENTS ARE TO HAVE NEW GASKETS INSTALLED.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Unknown
Issued 29 October 1987 Resolved
REMOVE OIL AND OIL RESIDUE FROM ENGINE ROOM BILGE: NO HOT WORK PREMITTED UNTIL THIS ITEM HAS BEEN COMPLETED.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Electrical
Issued 29 May 1986 Resolved
REMOVE DEADEND WIRING.
Condition: Unknown
Due 29 May 1986
Resolved 29 May 1986
Lifesaving
Issued 29 May 1986 Resolved
PROVIDE PERMANENT PAINTERS TO REPLACE THE TEMPORARY PAINTERS ON THE LIFEFLOATS.
Condition: Unknown
Due 29 May 1986
Resolved 29 May 1986
Electrical
Issued 29 May 1986 Resolved
PROVIDE SOLDER TYPE BATTERY CONNECTIONS.
Condition: Unknown
Due 29 May 1986
Resolved 29 May 1986

Casualty record · 2

23 September 2023Routine · role: Involved in a Marine Casualty · activity 7798571
26 June 2025Routine · role: Involved in a Marine Casualty · activity 8172053
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.