13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 June 2025
Resolved
Exhaust piping shall be gas tight throughout its length.
Exhaust piping on the port side engine muffler is leaking.
46 CFR 192.15-20 (old T).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2025
Resolution: O/O used fire retardant resin and fiberglass to patch the hole in the port side engine silencer.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 June 2025
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc.
PTO for fire pump on the main engine does not have any guards to protect personnel from accidental contact.
46 CFR 177.35-10 (old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 11 July 2025
Resolution: O/O installed guards around PTO.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 24 June 2025
Resolved
A vessel must comply with the applicable requirements for any radio as set forth in 47 CFR part 80 by the Federal Communications Commission (FCC).
VHF radio had incorrect MMSI programmed in.
Action required: 705 - Other - as specified
Resolved 5 August 2025
Resolution: Received photo of correct MMSI loaded into radio.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 June 2025
Resolved
If a machine is to be utilized in a space in which the machines rated ambient temperature is below the assumed ambient temperature of the space, it must be used at a derated load.
Generator has been derated to below 80% amperage, but needs to be marked on the generator breaker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 11 July 2025
Resolution: O/O labeled generator breaker as "DERATED"
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2025
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom.
Vessel had combustible trash cans in the bridge and head.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 11 July 2025
Resolution: O/O replaced plastic trash cans with metal trash cans.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 June 2025
Resolved
vessel on a lakes, bays, and sounds, or rivers route must carry three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.
Vessel missing 01 orange distress signal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2025
Resolved 27 June 2025
Resolution: O/O put an additional orange flare on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 June 2025
Resolved
Each life jacket carried on board the vessel must be marked in accordance with § 185.604 of this chapter.
07 lifejackets on vessel are not marked with vessel name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2025
Resolved 11 July 2025
Resolution: O/O labeled 07 lifejackets with vessel name.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 November 2024
Resolved
At each inspection for certification and at every other
vessel inspection the bilges and other spaces may be
examined to see that there is no excessive accumulation
of oil, trash, debris, or other matter that might create
a fire hazard, clog bilge pumping systems, or block
emergency escapes. Excessive oil and absorbent pads in the bilge. 46 CFR 176.830(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2024
Resolved 19 November 2024
Resolution: New diapers placed in E/R and Oil Pan inserted below engines
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 November 2024
Resolved
Each battery must be located as high above the bilge as
practicable, secured to protect against shifting with
the roll and pitch of the vessel, and free from exposure
to water splash or spray.
Spare batteries were being stored on the deck plate in
the engine room and not secured in trays. 46 CFR 183.350(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2024
Resolved 19 November 2024
Resolution: Batteries stored in trays
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 7 November 2024
Resolved
A work space must be of sufficient size, adequate
construction, and with suitable equipment to provide for
the safe operation of the vessel and the protection and
accommodation of the crew.
Engine room access ladder and deck plates are not safe.
46 CFR 177.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2024
Resolved 19 November 2024
Resolution: New deck plates installed in E/R
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 November 2024
Resolved
The construction and arrangement of a vessel must allow
the safe operation of the vessel in accordance with the
terms of its Certificate of Inspection giving
consideration to provisions for a seaworthy hull.
Vessel has damaged planks on the stbd bow and stbd
quarter.
46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2024
Resolved 27 December 2024
Resolution: Vsl planks on stbd bow and stbd quarter repaired. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 November 2024
Resolved
Machinery and equipment installed on each vessel must be
suitable for the vessel and its operation and for the
purpose intended.
External battery charger was being used in leu of
alternator to charge generator start battery.
46 CFR 182.100
Action required: 10 - Deficiency Rectified
Resolved 7 November 2024
Resolution: External battery charger removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2024
Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel.
Exhaust leak found on port engine, causing exhaust to leak into engine room. 46 CFR 182.430(a)
Action required: 705 - Other - as specified
Resolved 27 December 2024
Resolution: Received photos of new exhaust piping on port engine. See Documents for pictures.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 August 2024
Resolved
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 6 inches above the deepest subdivision load line must have a means to prevent water from entering the Bessel if the pipe fractures or otherwise fails. Inspectors could not properly operate shutoff valve on stbd engine jacket water intake, needs replace. 46 CFR 171.119 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 12 September 2024
Resolution: Received photos and video of new, operable shutoff valve installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 August 2024
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or origination in electrical equipment, and reasonably safe from electrical shock of personnel. Inspectors found terminal box in vicinity of Engine Room entrance ladder with exposed wiring due to missing a cover. 46 CFR 183.01-5 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 12 September 2024
Resolution: Received photo of new cover installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 August 2024
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or origination in electrical equipment, and reasonably safe from electrical shock of personnel. Inspectors found terminated wires on the starboard side of the engine room below ventilation opening that need to be removed. 46 CFR 183.01-5 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 12 September 2024
Resolution: Received photos of dead end wires removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 May 2024
Resolved
A life jackets must be provided for each person the vessel is authorized to carry as indicated on the COI; two life jackets were condemned due to their deteriorated condition. The vessel is restricted to 72 total persons until the life jackets are replaced. 46 CFR 180.71
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2024
Resolved 10 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 May 2024
Resolved
Where flexible non-metallic piping (hose) is permitted in piping systems it must meet the required specifications for its intended purpose and be otherwise acceptable to the OCMI; the hose on the discharge side of the fire pump is deteriorated and must be replaced. 46 CFR 182.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2024
Resolved 10 June 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 May 2024
Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals; the existing battery boxes do not have covers. 46 CFR 183.05-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 10 June 2024
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 29 May 2024
Resolved
The public address system must be audible during normal operating conditions throughout the accommodation spaces; the starboard speaker is not working. 46 CFR 184.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 10 June 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 May 2024
Resolved
A vessel must carry a first aid kit, approval number ISO, or a kit with an equivalent contents; replace the expired aspirin and ensure proper inventory. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 10 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 May 2024
Resolved
The name of the vessel must be marked in clearly legible letters on each life float paddle; the markings have faded and are not legible. 46 CFR 185.604 (g)
Action required: 10 - Deficiency Rectified
Resolved 29 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 May 2024
Resolved
The remote fuel shutoff station must be clearly marked in clearly legible 1 inch letters; the new covers in the deck have not yet been marked. 46 CFR 185.608
Action required: 10 - Deficiency Rectified
Resolved 29 May 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 May 2024
Resolved
A vessel must undergo an annual inspection within 30 days before or after each anniversary date. Due to an extended dry dock period, the vessel is overdue for an annual inspection, make the vessel available for inspection prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2024
Resolved 29 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 September 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel; 08 Lifejackets are condemed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 22 September 2022
Resolution: Lifejackets replaced
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 19 September 2022
Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space; vessel's vent closures did not work as designed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 September 2022
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment; vessel's racor filters had excessive build up of algae and require cleaning and replacement.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 September 2022
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 19 September 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull; vessel has soft spot on deck IWO Fishbox.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 22 September 2022
Resolution: Temporary plywood patch installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 May 2021
Resolved
Positive cable ring terminal on positive lead for Port MDE starting is corroded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 4 June 2021
Resolution: Terminal secured properly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 May 2021
Resolved
At each inspection vessel rep must be prepared to conduct tests of all machinery; generator air filter is missing from prime mover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 4 June 2021
Resolution: Air filter was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 May 2021
Resolved
At each inspection, vessel rep. must be prepared to conduct tests of all machinery; fuel coolers on both MDEs have broken brackets and are hanging.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 4 June 2021
Resolution: Fuel coolers were secured to overhead using plumbers strap
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 May 2021
Resolved
Steering apparatus installed on the vessel must be suitable for the vessel's operation; port rudder packing is leaking excessivley.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 4 June 2021
Resolution: Port rudder port was re-packed
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 12 May 2021
Resolved
Materials used in piping systems must be acceptable to the OCMI; deck drain pipe in #4 void is broken and leaking water into the void.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 4 June 2021
Resolution: PVC Pipe deck drain was repaired using rubber coupling
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel; MI identified 04 Kapok lifejackets in unacceptable condition.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 4 June 2021
Resolution: Lifejackets were replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 July 2020
Resolved
Each hatch exposed to the weather must be watertight; the forepeak hatch is not operational in that the gasket is not functional and the dogging devices are frozen.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 July 2020
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment; the bilge pump was unable to take suction from the forepeak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 6 July 2020
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level in all watertight compartment of a wood boat; the bilge alarm in the forepeak is not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 July 2020
Resolved
A vessel must have a reliable means of shutting down a propulsion engine at the main pilothouse control station; the port main engine shut down did not work.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 July 2020
Resolved
The vessel must carry a first aid kit with the proper inventory; some items in the kit are expired and the storage container is broken and no longer watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2020
Resolved
Electrical installations shall be to the satisfaction of the OCMI and such that they do not pose a shock hazard to personnel; the receptacle under the counter in the galley does not have a cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 July 2020
Resolved
Each survival craft required on a vessel must meet the applicable requirement for craft type (life float 160.027); the life float is faded and does not meet the color requirement of the approval number.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2020
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 July 2020
Resolved
Each vessel that operates beyond three miles from shore must have a properly installed EPIRB; the hydrostatic release mechanism is about to expire.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 July 2020
Resolved
Nonmetallic materials (hose) used in vital system piping systems must meet the specification (SAE-J1942) and characteristics for it's intended service; the fuel hose between the fuel pump and the fuel filter is deteriorated with metal braid exposed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 August 2019
Resolved
Electrical arrangements shall be such that there is minimal risk to crew and passengers. Remove or properly terminate dead end wires in pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Received documentation to properly clear def.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 August 2019
Resolved
Remove inoperable GPS from operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Received documentation to properly clear def.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 August 2019
Resolved
All vessels must have navigation lights in accordance with the nav rules. The mast head and stern light clear plastic lens is faded. Replace with manufacturers approved parts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Received documentation to properly clear def.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 August 2019
Resolved
There is a deteriorated electrical junction box in the rod room and a light fixture in the engine room that needs replacing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Received documentation to properly clear def.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 9 July 2018
Resolved
Make repairs to installed PA system or provide hand held bull horn. (A temp system was installed utilizing the stereo and blue tooth)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 25 July 2018
Resolution: Replaced the radio which is used for PA system.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 July 2018
Resolved
Make gas tight repairs to open penetrations in aft bulkhead of engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2018
Resolution: Seealed with 5200 sealant and plywood.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 July 2018
Resolved
Provide hard copy excerpts of the following nav pubs: coast pilot and light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2018
Resolved
Provide the following additional items to bring the first aid kit into compliance with 46CFR160.041-4(b): Bandage compress 4" - 2, Triangular Bandage 40" - 1, Bandage Gauze 2" x 6 yards -1, 12 safety pins, forcepts, scissors, sterile petroleum gauze 3" x 18" - 12.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2018
Resolved
Ensure double hose clamps on all exhaust (main engine) connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2018
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 July 2018
Resolved
Label remote fuel shut off valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2018
Resolved
Remove wing nuts from generator battery, install permenant fasteners.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2018
Resolved
Replace stbd engine throttle linkage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2018
Resolved
Replace deteriorated fuel hose on port main engine-ensure hose is SAE J-1942.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2018
Resolved
Make permenant repairs to stbd main jacket water pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2018
Resolution: Steel tubing was removed, welded, and placed back in service without leaks.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2018
Resolved
Repair oil leak at stbd pressure gauge at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2018
Resolved
Remove temporary LED light installation, attached with spring clips.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2018
Resolved
The stbd shaft seal is leaking excessively; make repairs as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2018
Resolved 9 July 2018
Resolution: Shaft was repacked and excessive leak corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 April 2017
Resolved
Replace the waterlight lanyard on the ring buoy due to deterioration.
Due 27 April 2017
Resolved 14 April 2017
Resolution: Documentation recieved to clear deficiency.
Engineering › Fuel Oil Service System › Hose
Issued 13 April 2017
Resolved
Replace the non-approved fuel hose on the STBD main engine with an approved type (SAE J-1942).
Due 27 April 2017
Resolved 14 April 2017
Resolution: Documentation received to clear the deficiency.
Fire Fighting › Fire Main › Valves
Issued 13 April 2017
Resolved
Provide the vessel with a hose nozzle for the fire station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2017
Resolution: A satisfactory nozzle was located on the vessel while enroute to office.
Lifesaving › Lifefloat › Serviceable
Issued 18 July 2016
Resolved
Replace both lifefloats with CG approved floats. Ensure capacity is 50 persons total. Outfit and label as existing floats are.
Due 5 September 2016
Resolved 28 September 2016
Resolution: The owner purchased two used life floats, refurbished them, and installed them on the vessel.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 July 2016
Resolved
Place current excerpts of the following nav pubs onboard: Coast Pilot, Light list, tide tables and local chart.
Due 5 September 2016
Resolved 29 August 2016
Documentation › Logs/Records › Logbook (official)
Issued 18 July 2016
Resolved
Keep ships log current for training and drills (MOB and fire).
Due 5 September 2016
Resolved 29 August 2016
Engineering › Fuel Oil Service System › Piping
Issued 18 July 2016
Resolved
Replace tension clamps on generator return rail/lines with corrosion resistant screw clamps.
Due 5 September 2016
Resolved 29 August 2016
Engineering › Fuel Oil Service System › Filter
Issued 18 July 2016
Resolved
Provide documentation for generator filter heat rating or change to metalic filter bowl. Remove petcock style drain valve.
Due 5 September 2016
Resolved 29 August 2016
Resolution: Replaced fuel filter with RACOR type filter.
Communications › Radio Communications › VHF Radiotelephone
Issued 18 July 2016
Resolved
Provide MMSI equipped DSC capable radio pending CG waiver request with FCC.
Due 18 July 2017
Resolved 12 December 2016
Engineering › Compressed Air System (control) › Compressor
Issued 25 March 2016
Resolved
Replace the existing non-approved air compressor with an approved type (ASME "U" or "UM").
Due 25 April 2016
Resolved 19 July 2016
Resolution: A ASME stamped pressure vessel has been installed.