DON INNOVATION is a 1971 passenger vessel (uninspected). The Coast Guard has recorded 74 inspections since 1984, most recently in May 2025, along with 167 deficiencies and 1 operational control.

Records from 1984 to 2025. Most recent: inspection, 20 May 2025.

Built
1971
Last inspected
20 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ3296
Flag
UNITED STATES
367766630
Maury page id
psix-46881

Inspections, by type

…with no type recorded6
Years with a record 36 calendar years (1984–2025)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)33.8 ft × 12.8 ft × 5.3 ft
Registered tonnagegross 14 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · FORT LAUDERDALE FL · built 1971
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Net Ton
14 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ3296MMSI 367766630 · active · compulsorily equipped · granted 29 December 2016, expires 29 December 2026
WYZ3913MMSI 367141310 · expired · compulsorily equipped · granted 23 September 2006, cancelled 11 February 2017 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 74

20 May 2025 Uninspected Passenger Vessel
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8152774
18 February 2025 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8081273
12 March 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7865321
24 January 2024 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7857481
20 March 2023 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7652117
6 October 2022 Deficiency Check · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7572020
21 January 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7382528
3 March 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7149752
12 November 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7071449
25 June 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6985771
2 April 2019 DAPI Audit · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6651903
23 October 2018 Hull Examination · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6565571
16 February 2018 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6356358
16 October 2017 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6288517
2 November 2016 Hull Examination · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6033756
17 May 2016 DAPI Audit · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5886604
8 December 2010 Hull Examination · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3906552
19 February 2010 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3682202
15 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3664439
8 December 2009 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3646835
5 November 2008 Drydock Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3387087
14 November 2007 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3098190
8 January 2007 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2851961
20 October 2006 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2804634
5 October 2006 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2794116
5 May 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2349711
22 December 2004 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2278511
10 November 2003 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1945221
16 September 2003 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1907031
16 September 2003 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2361096
26 January 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1735467
6 November 2002 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1704682
1 May 2002 Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1611092
26 September 2001 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1469065
23 May 2001 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1379451
18 May 2001 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1064354
12 July 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1052027
4 January 2000 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 813753
1 December 1999 Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1420225
30 November 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 812426
16 April 1999 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1117638
16 April 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1410078
11 March 1999 Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 805771
19 February 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1388738
7 October 1997 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1427476
4 September 1997 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1390599
13 February 1997 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1359353
21 February 1996 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1459976
24 December 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1188919
13 September 1995 Hull Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1360258
5 April 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1167594
24 February 1994 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1449670
1 December 1993 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1379888
2 September 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 831431
10 March 1993 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1362743
16 June 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 952623
2 March 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1266449
16 January 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1259902
7 November 1991 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 948148
12 April 1991 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1211172
12 March 1991 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1219818
21 April 1990 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1216309
12 March 1990 COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 926384
27 September 1989 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1304939
8 March 1989 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1207339
24 October 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1203547
20 September 1988 Re-Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1200190
9 March 1987 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1323569
13 November 1986 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1316355
13 November 1986 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1328925
23 April 1986 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1306473
10 May 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1287276
27 March 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 980094
16 March 1984 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1328926

Deficiency record · 167

14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 12 March 2024 Resolved
1. When operating a vessel on a body of water where the discharge of untreated sewage is prohibited, the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods include - (1) closing each valve and removing the handle; (2) padlocking each valve in the closed position; (3) Using a non-releasable wire tie to hold each valve in the closed position. Vessel has type III MSD system and system was not secured to prevent discharge. 33 CFR 159.7 (c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2024
Resolved 13 March 2024
Resolution: Received pictures via email of the appropriately covered, locked, and secured MSD discharge valve on board. Deficiency 01 cleared.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 12 March 2024 Resolved
A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling water system. Vessel did not have a raw water hull strainer installed. Install strainer. 46 CFR 182.420(a)(2)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2024
Resolved 21 March 2024
Resolution: Received pictures via email showing evidence of a raw water intake strainer at the under side of the hull. Deficiency 02 cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 January 2024 Resolved
Repairs or alterations to the machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement or repair, propulsion and systems; alterations affecting stability. The owner or managing operator shall submit written specifications describing the details of any proposed alterations to the cognizant OCMI for approval before work is started. The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Vessel main diesel engine was removed to be replaced for a new engine, without notifying USCG Inspections Office. 1. Provide specifications of existing and new engine to be installed for approval; 2. complete and submit the document Guidance for Repowering Vessels Inspected under 46 CFR Subchapter T with both engines specifications; 3. Prove proper operation of main diesel engine during sea trials prior to departure carrying passengers. 46 CFR 176.700, Code 17C.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 February 2024
Resolution: Installed engine was found to be in kind and tested satisfactory during sea trials.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 March 2023 Resolved
Repairs or alterations to equipment that affect the safety of the vessel must not be made without the approval of the OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include electrical wiring. The owner or managing operator shall submit drawings, sketches, or details of any proposed alterations to the cognizant OCMI. A new wiring diagram or electrical systems schematic is required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2023
Resolved 3 June 2024
Resolution: Final electrical plan reviewed and approved.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 March 2023 Resolved
Machinery space boundaries. Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant. Found that the overhead area forward of the propulsion engine was missing the noncombustible panels.46 CFR 177.410(c )(4)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2023
Resolved 25 April 2023
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 20 March 2023 Resolved
02107-The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Both the port and starboard hull fuel tank vents flame screens were partially blocked by paint.46 CFR 182.450
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 March 2023 Resolved
09112-A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2023
Resolved 25 April 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 March 2023 Resolved
02108-Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: A pressure type connector on each conductor; A solder lug on each conductor. Found in the forward cabin port side that two electrical terminal blocks had stranded wire connected directly without using pressure type terminal connectors.46 CFR 183.340(g)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 March 2023 Resolved
02108-Electrical equipment on a vessel must be installed and maintained to: Provide services necessary for safety under normal and emergency conditions; Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Minimize accidental personnel contact with energized parts. Found the following: ( a) Forward cabin port side, the two electrical terminal blocks and pressure type electrical connectors are corroded. Also there was no cover installed to prevent items stored in this area from shorting out the connects. (b) Under the steering console, the clip type fuse panel and pressure type electrical connectors are corroded. (c) The propulsion engine battery selector switch connections are corroded.46 CFR 183.220
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2023 Resolved
CG204-Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. The following restrictions apply: Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose, or field attachable type fittings may be used. Hose end fittings must comply with SAE J-1475. Found no marking that fuel lines meets SAE J 1942 or had be spliced, and did not have connections meeting SAE J 1945. For all supply and return lines to the port and starboard fuel tanks. 46 CFR 172.720(g)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2023 Resolved
CG204-Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the supply line, at the tank connection. Found the handle for the shutoff valve located at the starboard fuel tank was loose and could not confirm the valve closed when the valve was operated by the remote pull.46 CFR 182.20-40(b)(3)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2023
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 March 2023 Resolved
02105-Except as further modified in this section all single screw vessel in ocean and coastwise service shall be provided with an auxiliary steering arrangement located above the weather deck. Found the auxiliary steering arrangement would not operate, there was no means to quickly disconnect the hydraulic ram from the rudder assembly.46 CFR 182.30-5(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2023 Resolved
11117-All vessels shall be fitted with one ring buoy of not less than 24 inches in diameter. Found following deteriorated, the line around the outside was diameter deteriorated and the retro tape. 46 CFR 180.30.5(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 March 2023 Resolved
03107-A hatch exposed to the weather must be watertight, have securing devices and be attached by hinges, captive chains or other devices or substantial strength to prevent its loss. Found that the port and starboard deck hatches located in way of the operating station not have captive devices to prevent their loss. 46 CFR 179.360
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2023
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 20 March 2023 Resolved
04110-Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Found that one of the two required portable battery lights was not operational.46 CFR 183.43
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2023
Resolved 3 April 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 March 2023 Resolved
10109-The lights and shapes specified in these Rules shall comply with the provisions of Annex I of these Rules (33 CFR part 84.13(c). Found: a. The fixture used as a stern light did not meet the requirements of having an unbroken light over an arc of the horizon of 135° and so fixed as to show the light 67.5° from right aft on each side of the vessel. b. The means of turning on all around light (anchor light)is not separate from the rest of the navigation lights.46 CFR 183.43
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2023
Resolved 3 April 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 March 2023 Resolved
02108-All electrical equipment and circuits must be clearly marked and identified. The individual fuses for the fuse panel were not marked showing load being serviced. Located on forward end, under the steering console.46 CFR 183.200(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2023
Resolved 3 April 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 January 2022 Resolved
The marine employer must have a sufficient number of alcohol detecting testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the Serious Marine Casualty. Alcohol detecting swabs on board were found to be expired in YR2021, and lacking on an additional swab as one master and two deckhands are currently operating this vessel. Obtain an approve alcohol breathalyzer and/or current not expired alcohol swabs for all crew. 46CFR06-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2022
Resolved 4 February 2022
Resolution: A DOT approved alcohol breathalyzer was placed on board, alcohol swabs have been ordered, pending delivery delayed by the USPS.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 January 2022 Resolved
An Employee Assistance Program (EAP) must be conducted for the employer’s crewmembers and supervisory personnel. The training program must include at least the following elements: The effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crew members and employer’s supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Conduct an Employee Assistance Program training at all levels (master, deckhands and management supervisory level) and provide evidence of training.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2022
Resolved 4 February 2022
Resolution: Training was condected, verified training docuemntation and crew answered questions about DAPI and alcohol test panel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 January 2022 Resolved
For each marine casualty required to be reported by 46CFR185.202, the vessel owner, master, or person in charge of the vessel shall determine whether there is any evidence of alcohol or drugs use by the individuals directly involved in the casualty. The owner, master or person in charge of the vessel shall include in the written report, Form CG-2692. Vessel captain failed to answer the correct reporting procedures in accordance of the regulation in how much time a alcohol or drug testing must be conducted after a marine casualty. Vessel captain must be trained and demonstrate knowledge in what are the conditions of a reportable marine casualty and timeframe for drug and alcohol testing for the satisfaction of an attending USCG Marine Inspector. 46CFR185.210.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2022
Resolved 4 February 2022
Resolution: Vessel master was trained in DAPI and also questioned about testing procedures following after a marine casualty, all answers were found to be correct.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 January 2022 Resolved
All vessels must carry adequate and up-to-date nautical charts. Vessel was found to have a nautical chart without evidence of being updated since 2007. Update nautical chart in accordance with all changes as provided in the publication called Noticed to Mariners. 46 CFR 185.20-35.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2022
Resolved 4 February 2022
Resolution: Vessel nautical chart was updated in acordance with correction in Notice of Mariners Publication.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 21 January 2022 Resolved
Prepare and post emergency check-up list in a conspicuous place accessible to crew and passengers. Emergency checkup list may follow the recommended format in accordance with 46 CFR 185.25-5. Vessel was found not having posted emergency instructions or checkup list. Provide emergency instructions and post it in a conspicuous place accessible for passengers and crew. 46CFR185.25-1 and 46CFR185.25-5.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2022
Resolved 4 February 2022
Resolution: A new set of emergency instruction was placed visible for crew and passengers.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 January 2022 Resolved
A vessel on which a pre-engineered fixed gas fire system is installed must have a light to indicate discharge and an audible alarm that sounds upon discharge at the operating station. USCG Marine Inspector found that the visual light to indicate discharge was not operational. Replace the visual alarm and prove proper operation during testing of the system for the satisfaction of an attending USCG Marine Inspector. 46 CFR 181.420 (4)(b)(1).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2022
Resolved 4 February 2022
Resolution: Re-tested the pre-engineered fixed fire system and both visual display light and audio alarm were found operating.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 21 January 2022 Resolved
A hatch exposed to the weather must be weathertight and have securing devices. The following were found not to be weathertight and missing securing devices: a. forward hatch in front of the accommodation space, which is forward of the operating station; and b. center window right of the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2022
Resolved 4 February 2022
Resolution: Both window and hatch were made weathertight by the instalation of ruber gasket seal all around.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 January 2022 Resolved
Compliance in all weathers. Rules concerning lights and shapes a vessel is required to have sidelights, means a green light on the starboard and a red light on the portside, a sternlight means a white light placed as nearly as practicable at the stern. Day shapes must have a ball, diamond, ball configuration. Vessel’s current navigation red and green lights lens was found faded by UV exposure, and sternlight inoperable. In addition, vessel did not have on board any dayshapes. Replace both red and green, and sternlight navigation lights with an approved type, and provide the day shapes. 33CFR83.20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2022
Resolved 4 February 2022
Resolution: Tested port, starboard and setrn navigation lights, all found operable and in compliance with 2NM rule. Also, the vessel had installed the dayshape corresponding the service and size of the boat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 March 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 16 March 2021
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 3 March 2021 Resolved
Requirements of the Federal Communications Commission. A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. MMSI # Does not match up to certificate.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 16 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2021 Resolved
All fuel tanks must be electrically bonded to a common ground. STB Side fuel tank not grounded.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 16 March 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 3 March 2021 Resolved
A hatch exposed to the weather must be watertight. Deck foaming has a 26” soft/water logged wood.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 16 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2021 Resolved
The marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever the condition of the shafting and bearings are in question. Change clamps for shaft packing glans.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 16 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 June 2020 Resolved
Pre- engineered fire extinguishing systems must have a means to reset device used to automatically shut down the engine. Engine override switch does not operate. Vessel is restricted from carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2020
Resolution: Master proved full functionality of fire boy system.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 April 2019 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit Hydrostatic release for EPRIB is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 16 April 2019
Resolution: Hydrostatic release for EPRIB was replaced and new expiration date properlly recorded.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 April 2019 Resolved
At each vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard or clog bilge pumping systems. Wiring in engine space is not secured and rests in the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 16 April 2019
Resolution: Wiring in engine space is properlly secured.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 April 2019 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Railings block the visibility of port and starboard navigational lights. Navigational lights need to be in a location that does not prohibit the visibility and intensity of navigational lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 16 April 2019
Resolution: Navigational lights were adjusted to a location that provides effective visibility.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019 Resolved
The connection fittings on the non-metallic hoses for the oil cooler for the transmission are severely corroded and require replacement in accordance with regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 16 April 2019
Resolution: The connection fittings were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019 Resolved
In systems where flexible hoses are permitted to be clamped, two clamps must be used at each end of the hose. Flexible hose on engine cooling line needs to be readjusted and double clamped onto the though hull valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 16 April 2019
Resolution: Flexible hose was readjusted and double clamped onto the though hull valve.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 April 2019 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Coast Guard Light list and tide tables. Light list and tide tables for area of operation are out of date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 16 April 2019
Resolution: Had on board up-to-date Coast Guard Light list and tide tables.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 27 March 2018 Resolved
Prove proper operation of engine room pre-engineered fire fighting system. Install proper sytem, the bottle is fyrework and the override switch is fireboy.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 29 March 2018
Resolution: vessel properly installed fireboy system and inspectors verified.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 February 2018 Resolved
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 March 2018
Resolution: vessel representative installed GPS into the VHS system.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 February 2018 Resolved
properly install emergency steering.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 October 2018
Resolution: vessel representative installed emergency steering.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 16 February 2018 Resolved
Provide alarm and lights for the bilge system
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
Resolution: vessel representative fixed wiring for alarms. all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 February 2018 Resolved
Properly install machinery guards on the exposed moving parts of the engine.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
Resolution: vessel representative installed machinery guards.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 16 February 2018 Resolved
Provide a garbage management plan for the vessel
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2018
Resolution: Vessel rep produceed a vessel specific garbage management plan.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2018 Resolved
Repair the fuel line splice
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2018
Resolution: vessel representative repaired the fuel line
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 February 2018 Resolved
Inspect and repair leak on the vessel's shaft.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
Resolution: Vessel representative fixed leak.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 February 2018 Resolved
Provide proper amount of flashlights.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
Resolution: vessel rep provided correct number of flashlights
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 16 February 2018 Resolved
Properly label distress signals watertight container with the words "DISTRESS SIGNALS"
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2018
Resolution: vessel rep provided proper box
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 16 February 2018 Resolved
Provide proper amount of distress signals
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2018
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 February 2018 Resolved
Provide appropriate first aid kit
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 February 2018 Resolved
properly label fire buckets with the words "FIRE BUCKET"
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 February 2018 Resolved
Relabel the lifebuoy with proper vessel name and hailing port
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2018 Resolved
provide proper stowage labeling for the adult and child life jackets
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2018 Resolved
replace retroreflective tape on 23 life jackets
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
01 - Certificates & Documentation › 013 - Documents › Fire safety operational booklet
Issued 16 February 2018 Resolved
provide proof of servicing of all three fire extinguishers and fireboy system
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2018
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 16 February 2018 Resolved
the captain of the vessel must provide proof of credentials
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 February 2018 Resolved
provide proof of the vessel's radiotelephony certificate
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 16 February 2018 Resolved
provide registration decal for EPIRB
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 16 February 2018 Resolved
provide updated information for the Employee Assistance Program and properly post in a common and accessible area
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 16 February 2018 Resolved
provide proof of all crew enrolled in a consortium or equivalent program
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
Engineering › Fuel Oil Service System › Piping
Issued 2 November 2016 Resolved
properly repair spliced supply fuel line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 November 2016
Resolution: fuel line was replaced and corrected.
Engineering › Bilge Water Management System › Pump
Issued 2 November 2016 Resolved
replace Rule 2000 electrical submersible bilge pumps with the UL listed type.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 9 November 2016
Resolution: pumps were replaced with UL listed type.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 November 2016 Resolved
properly repair rotted wood found on forward transverse bulkhead between engine compartment and forward accommodation space.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 7 November 2016
Resolution: rotted wood was removed and new section installed
Construction/Loadline › Structures › Deck Plating
Issued 2 November 2016 Resolved
properly repair unfinished epoxy repair at transom.
Action required: 705 - Other - as specified
Resolved 9 November 2016
Resolution: transom area was repaired.
Construction/Loadline › Structures › Deck Plating
Issued 2 November 2016 Resolved
properly close opening between the engine compartment and operating console.
Action required: 705 - Other - as specified
Resolved 7 November 2016
Resolution: opening between engine compartment and operating console was closed off.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 2 November 2016 Resolved
FRP structure (pulpit) that supports the anchor is wasted and needs repair.
Action required: 705 - Other - as specified
Resolved 9 November 2016
Resolution: Anchor pulpit was repaired.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 May 2016 Resolved
Replace 7 lifejackets. Vessel is restricted to 20 passengers until sufficient amount of approved preservers are provided.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 8 June 2016
Lifesaving › Lifebuoys › Serviceable
Issued 17 May 2016 Resolved
Replace life ring with approved type in serviceable condition. 46 CFR 180.70(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 8 June 2016
Engineering › Fuel Oil Service System › Suction Strainer
Issued 17 May 2016 Resolved
Install approved marine grade fuel strainer. 46 CFR 182.455.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 8 June 2016
Communications › Radio Communications › Satellite Communications Capability
Issued 17 May 2016 Resolved
Program MMSI number in VHF-DSC Radio.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 8 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2016 Resolved
Provide 160.041 approved first aid kit and remove all expired items from the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 8 June 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 December 2009 Resolved
Vessel was not made available for its annual inspection within 90 days before or following the anniversary of the issuance of its Certificate of Inspection rendering the COI invalid.
Action required: 705 - Other - as specified
Resolved 19 February 2010
Resolution: Completed new COI exam.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 5 November 2008 Resolved
Install and test properly functioning fireboy sysem. (engine shutdowns)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 December 2008
Resolution: Installed properly functioning fireboy system capable of shutting down the engines upon actuation.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 November 2007 Resolved
Provide rettrotape on all 4 child lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2007
Resolution: New tape installed.
Lifesaving › Lifefloat › Float Free
Issued 14 November 2007 Resolved
Provide float free lifefloat. (clean mildew of lifefloat)
Action required: 705 - Other - as specified
Due 15 December 2007
Resolved 19 November 2007
Resolution: Corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 November 2007 Resolved
Provide operational lifering light.
Action required: 705 - Other - as specified
Resolved 19 November 2007
Resolution: Corected.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 8 January 2007 Resolved
Issued requirement to have all publications on board.
Action required: 705 - Other - as specified
Due 19 January 2007
Resolved 19 January 2007
Resolution: All pubs were placed on board.
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 8 January 2007 Resolved
Issued requirement to replace all retro tape on life jackets.
Due 19 January 2007
Resolved 19 January 2007
Resolution: New retro tape was placed on every life jacket.
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 January 2007 Resolved
Issued requirement to provide training and have maintenance log
Due 19 January 2007
Resolved 19 January 2007
Resolution: Training and maintenance log placed on board.
Communications › Radio Communications › EPIRB
Issued 22 December 2004 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE OPERATIONAL EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2005
Resolved 5 May 2005
Lifesaving › Buoyant Apparatus › Serviceable
Issued 22 December 2004 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE 18 PASSENGER BUOYANT APPARATUS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2005
Resolved 14 December 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 December 2004 Resolved
PRIOR TO CARRYING PASSENGERS, STENCIL STORAGE AREA OF CHILDREN AND ADULT LIFEJACKETS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2005
Engineering › Fuel Oil Service System › Valve
Issued 22 December 2004 Resolved
PRIOR TO CARRYING PASSENGERS, STENCIL REMOTE FUEL SHUT OFF VALVE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 22 December 2004 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE 1 SERVICED B1 EXTINGUISHER.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2005
Construction/Loadline › Hull › Transverse Frame
Issued 17 September 2003 Resolved
FOUND SIGN OF WOOD DRY ROT IN FRAMING INSIDE ENGINEROOM STBD SIDE. SUBMIT REPAIR PROPOSAL FOR REPLACEMENT OF DRY ROTTED FRAMING IN ENGINEROOM STBD SIDE TO MSO SAN JUAN.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2003
Resolved 22 December 2004
Engineering › Sea-water System (primary cooling) › Valve
Issued 17 September 2003 Resolved
REMOVE ALL THRU HULL FITTING FOR INSPECTION
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2003
Resolved 22 December 2004
Construction/Loadline › Hull › Hull Plating
Issued 16 September 2003 Resolved
Remove all thru hull fittings for inspection.
Due 16 October 2003
Resolved 31 October 2003
Construction/Loadline › Hull › Longitudinal Frame
Issued 16 September 2003 Resolved
Submit repair proposal for replacement of dry rotted framing in engineroom stbd side overhead prior to placing vessel in dock.
Due 3 November 2003
Resolved 31 October 2003
Personnel › Training
Issued 6 November 2002 Resolved
50 % of the total crew must comply wit CPR/First Aid Training. training expired on 2001. LEGACY COMPONENT DESC: First Aid/CPR
Due 22 December 2002
Resolved 19 December 2002
Lifesaving › Lifejacket/PFD (General)
Issued 1 May 2002 Resolved
Replace retro tape on 2 PFDs LEGACY COMPONENT DESC: Marking
Due 7 May 2002
Resolved 2 August 2002
Resolution: Corrected
Lifesaving › Hand Flares
Issued 1 May 2002 Resolved
Remove expired pyro. LEGACY COMPONENT DESC: Storage
Due 2 May 2002
Resolved 2 August 2002
Resolution: Corrected.
Communications › Radio Communications
Issued 1 May 2002 Resolved
Replace EPIRB battery. LEGACY COMPONENT DESC: EPIRB
Due 31 May 2002
Resolved 2 August 2002
Resolution: Corrected
Construction/Loadline
Issued 26 September 2001 Resolved
Repair/renew all delaminated spots on u/w hull and submit a detailed repairproposal prior to completion of work. This must be completed within 30 days or priort to re-launching vessel
Condition: Unknown
Due 5 November 2001
Resolved 21 November 2001
Lifesaving
Issued 23 May 2001 Resolved
Replace retro-freflective tape on 03 child size lifejackets. Prior to next sail.
Condition: Unknown
Due 23 May 2001
Resolved 8 June 2001
Engineering
Issued 23 May 2001 Resolved
Provide fire and impigment bowl for fuel filter.
Condition: Unknown
Due 10 June 2001
Resolved 8 June 2001
Fire Fighting
Issued 23 May 2001 Resolved
Provide service report for fix and portable fire extinguishing systems.
Condition: Unknown
Due 10 June 2001
Resolved 8 June 2001
Construction/Loadline
Issued 23 May 2001 Resolved
Ripair visual alarm for bilge high level alarm.
Condition: Unknown
Due 10 June 2001
Resolved 8 June 2001
Lifesaving
Issued 1 December 1999 Resolved
Provide CG approved first aid kit.
Condition: Unknown
Due 1 January 2000
Resolved 16 December 1999
Electrical
Issued 1 December 1999 Resolved
Rewire depth finder using connectors IAW 46 CFR 183.340.
Condition: Unknown
Due 1 January 2000
Resolved 16 December 1999
Documentation
Issued 1 December 1999 Resolved
Provide CPR certification for at least 50% of the crew.
Condition: Unknown
Due 1 January 2000
Resolved 3 January 2000
Unknown
Issued 1 December 1999 Resolved
Vessel is restricted to 15 passengers and 2 crew for a total of 17 persons,daylight hours only until SJ01, SJ04, SJ05, and SJ11 have been cleared.
Condition: Unknown
Due 1 January 2000
Resolved 16 December 1999
Lifesaving
Issued 1 December 1999 Resolved
Properly mount EPIRB IAW manufacturers instructions.
Condition: Unknown
Due 1 January 2000
Resolved 16 December 1999
Lifesaving
Issued 1 December 1999 Resolved
Provide light holder for ring buoy light and install.
Condition: Unknown
Due 1 January 2000
Resolved 16 December 1999
Fire Fighting
Issued 1 December 1999 Resolved
Provide 3 each 3.5 gallon fire buckets with lanyards properly marked.
Condition: Unknown
Due 1 January 2000
Resolved 16 December 1999
Lifesaving
Issued 1 December 1999 Resolved
Renew EPIRB Hydrostatic release mechanism. Provide copy of purchase recieptto MSO San Juan.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Documentation
Issued 1 December 1999 Resolved
Provide copy and post stability letter aboard vessel._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Documentation
Issued 1 December 1999 Resolved
Provide proof that all employees that operate vessel are enrolled in an approved system IAW 46 CFR 16.
Condition: Unknown
Due 1 January 2000
Resolved 3 January 2000
Navigation
Issued 1 December 1999 Resolved
Repair compass light
Condition: Unknown
Due 1 January 2000
Resolved 16 December 1999
Lifesaving
Issued 1 December 1999 Resolved
Provide 15 approved type I lifejackets, adult sized with retro tape to bring required amount to 32.
Condition: Unknown
Due 1 January 2000
Resolved 16 December 1999
Fire Fighting
Issued 11 March 1999 Resolved
PROVIDE A COMPLETE AND OPERATIONAL FIXED FIRE FIGHTING SYSTEM IAW 46 CFR 181.400 NLT 11 APRIL 99.
Condition: Unknown
Due 26 May 1999
Resolved 26 August 1999
Construction/Loadline
Issued 11 March 1999 Resolved
PROVIDE PLANS FOR INSTALLED BILGE HIGH LEVEL WARNING SYSTEM.
Condition: Unknown
Due 26 May 1999
Resolved 26 August 1999
Lifesaving
Issued 19 February 1999 Resolved
CONDUCT FIRE AND ABANDON MAN OVERBOARD DRILL IN CG INSPECTORS PRESENCE
Condition: Unknown
Due 1 March 1999
Resolved 20 April 1999
Documentation
Issued 19 February 1999 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING ENROLLEMENT FOR ALL CREWMEMBERS.
Condition: Unknown
Due 1 March 1999
Resolved 20 April 1999
Navigation
Issued 19 February 1999 Resolved
INSTALL OPERATIONAL BY PASS VALVE FOR EMERGENCY STEERING SYSTEM.
Condition: Unknown
Due 1 March 1999
Resolved 20 April 1999
Engineering
Issued 19 February 1999 Resolved
DEMONSTRATE PROPER OPERATION OF MAIN DIESEL ENGINE.
Condition: Unknown
Due 1 March 1999
Resolved 20 April 1999
Navigation
Issued 4 September 1997 Resolved
PROVIDE QUICK ACCESS TO RUDDER TILLER ARM TO FACILTATE EMERGENCY TILLER INSTALLATION
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Deck/Cargo
Issued 4 September 1997 Resolved
RENEW ANCHOR RODE
Condition: Unknown
Due 7 October 1997
Resolved 14 October 1997
Navigation
Issued 4 September 1997 Resolved
INVERT STEERING RAM TO TILLER BOLT SO THAT THE HEAD IS ON THE UPPER SIDE
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Lifesaving
Issued 13 February 1997 Resolved
PROVIDE BRIGHT COLORED PORTABLE WATERTIGHT CONTAINER LABELLED "DISTRESS SIGNALS" FOR FLARES.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Lifesaving
Issued 13 February 1997 Resolved
PROVIDE LIFEJACKET PLACARD WITH DONNING INSTRUCTIONS.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Lifesaving
Issued 13 February 1997 Resolved
PROVIDE RETRO-REFLECTIVE TYPE II TAPE ON RING LIFEBUOY.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Lifesaving
Issued 13 February 1997 Resolved
PROVIDE FLOAT FREE MOUNTED FCC TYPE ACCEPTED CAT. 1 406 MHZ EPIRB.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Lifesaving
Issued 13 February 1997 Resolved
PROVIDE LOGBOOK WITH ENTRIES FOR ABANDON SHIP, FIREFIGHTINGDRILLS, EPIRB TESTS, AND LIFESAVING EQUIPMENT MAINTENCE.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Electrical
Issued 13 February 1997 Resolved
PROVIDE SECOND OPERABLE PORTABLE BATTERY LIGHT AT OPERATING STATION (FLASHLIGHT).
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Documentation
Issued 13 September 1995 Resolved
Renew FCC Safety Certificate.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Accommodation/Occupational Safety
Issued 13 September 1995 Resolved
Remount blower by air compresser.
Condition: Unknown
Due 13 October 1995
Resolved 25 September 1995
Fire Fighting
Issued 13 September 1995 Resolved
Service fixed Co2 flooding system.
Condition: Unknown
Due 27 September 1995
Resolved 25 September 1995
Construction/Loadline
Issued 13 September 1995 Resolved
Crop and renew verticle support that has rot, located on bulkhead in front of air compresser.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Engineering
Issued 13 September 1995 Resolved
Fabricate and install hand guard on pulley on forward end of engine. (PTO to air compresser)
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Construction/Loadline
Issued 13 September 1995 Resolved
Tighten elbow on sea suction line at sea cock.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Electrical
Issued 13 September 1995 Resolved
Remount air compresser.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Navigation
Issued 13 September 1995 Resolved
Turn bolt on steering quradant over so nut is on the down side.
Condition: Unknown
Due 27 October 1995
Resolved 25 September 1995
Navigation
Issued 13 September 1995 Resolved
Repair or renew antenna mount
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Navigation
Issued 13 September 1995 Resolved
Procure 6 each hand held orange smoke signals.
Condition: Unknown
Due 27 September 1995
Resolved 25 September 1995
Lifesaving
Issued 13 September 1995 Resolved
Renew painter and grab lines on bouyant apparatus.
Condition: Unknown
Due 27 September 1995
Resolved 25 September 1995
Engineering
Issued 13 September 1995 Resolved
Install cap or plug in fuel strainer petcocks.
Condition: Unknown
Due 13 October 1995
Resolved 25 September 1995
Engineering
Issued 13 September 1995 Resolved
Repair diesel fuel leak in way of port fuel tank.
Condition: Unknown
Due 27 September 1995
Resolved 25 September 1995
Navigation
Issued 13 September 1995 Resolved
Repair running lights.
Condition: Unknown
Due 27 September 1995
Resolved 25 September 1995
Engineering
Issued 13 September 1995 Resolved
Renew or repair cracks in exhaust tube.
Condition: Unknown
Due 27 September 1995
Resolved 25 September 1995
Navigation
Issued 13 September 1995 Resolved
Preform radio check after launching.
Condition: Unknown
Due 13 October 1995
Resolved 25 September 1995
Lifesaving
Issued 13 September 1995 Resolved
Preform crew drills after launching.
Condition: Unknown
Due 27 September 1995
Resolved 25 September 1995
Lifesaving
Issued 13 September 1995 Resolved
repair surface cracks on buoyant apparatus.
Condition: Unknown
Due 27 September 1995
Resolved 25 September 1995
Documentation
Issued 13 September 1995 Resolved
Produce original Master's license.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Construction/Loadline
Issued 13 September 1995 Resolved
Renew screen in sea strainer.
Condition: Unknown
Due 27 September 1995
Resolved 25 September 1995
Construction/Loadline
Issued 24 February 1994 Resolved
Replace main engine cooling water through hull fitting.
Condition: Unknown
Due 25 February 1994
Resolved 25 February 1994
Engineering
Issued 24 February 1994 Resolved
Renew line to salt water transmission oil cooler.
Condition: Unknown
Due 25 February 1994
Resolved 25 February 1994
Lifesaving
Issued 24 February 1994 Resolved
Renew retro reflective tape on lifejackets.
Condition: Unknown
Due 24 February 1994
Resolved 24 February 1994
Lifesaving
Issued 10 March 1993 Resolved
Renew retroreflective tape on all PFD's as required. Vessel limited to daylight operatisn until retroreflective tape is replaced._x001C_
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Documentation
Issued 10 March 1993 Resolved
Provide proof of drug testing program in accordance with 46 Code of FederalRegulations Subpart 16.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Fire Fighting
Issued 10 March 1993 Resolved
Provide approved fixed fire extinguishing system for engine room and properly insulate overhead with non combustible panels approved by 46 Code of Federal Regulations Subpart 164.009.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Lifesaving
Issued 7 November 1991 Resolved
REPLACE GRABLINE ON LIFERING WITH 3/8 INCH BUOYANT SYNTHETIC LINE HAVING A MINIMUM BREAKING STRENGTH OF 1,350 POUNDS IAW 160.050-4(C)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Engineering
Issued 7 November 1991 Resolved
PROVIDE GUARD FOR PULLY ASSEMBLY ON AIR COMPRESSOR.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Accommodation/Occupational Safety
Issued 7 November 1991 Resolved
PROVIDE HAND RAILS AROUND VESSEL WHICH ARE MINIMUM OF 42" IN HEIGHT IN ACCORDANCE WITH 46 CFR 177.35(C)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Electrical
Issued 7 November 1991 Resolved
REMOVE DEAD END WIRES IN FORWARD VOID._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Construction/Loadline
Issued 7 November 1991 Resolved
REWELD ALL FRACTURES ON PLATFORM ON STERN OF VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Electrical
Issued 7 November 1991 Resolved
PROVIDE PROTECTIVE GLOBE AND CAGE FOR LIGHTBULB LOCATED IN RESTROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Lifesaving
Issued 7 November 1991 Resolved
LABEL BUOYANT APPARATUS WITH VESSEL'S NAME AND PERSON CAPACITY WITH MINIMUMOF 1 1/2" LETTERS IN ACCORDANCE WITH 46 CFR 180.20-5._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Construction/Loadline
Issued 7 November 1991 Resolved
MAKE PERMANENT REPAIRS TO OLD SINK OVERBOARD LOCATED ON STARBOARD SIDE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Lifesaving
Issued 7 November 1991 Resolved
ENSURE BUOYANT APARATUS IS SECURED TO VESSEL BY A PAINTER AND A FLOAT FREE LINK IN ACCORDANCE WITH 46 CFR 180.20-1. ALSO ENSURE BUOYANT APPARATUS IF SECURED BY LASHINGS IS CAPABLE OF QUICK RELEASE, THIS MUST BE DONE PRIOR TORETURNING VESSEL TO SERVICE._x001C_
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Unknown
Issued 7 November 1991 Resolved
MARK VESSEL NAME ON PORT BOW WITH MINIMUM OF 4" LETTERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Lifesaving
Issued 12 March 1991 Resolved
ATTACH RETROREFLECTIVE MATERIAL TO ALL LIFE PRESERVERS IN A ACCORDANCE WITH46 CODE OF FEDERAL REGULATIONS (CFR) SUBPART 180 25-25
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Fire Fighting
Issued 12 March 1991 Resolved
SERVICE ALL PORTABLE AND FIXED FIRE EXTINGUISHERS AS PER REQUIREMENT OF 46 CFR 176 25-25_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Lifesaving
Issued 12 March 1991 Resolved
ATTACH PAINTER AND WEAK LINK TO BUOYANT APPARATUS IN ACCORDANCE WITH 46 CFR180 15-5_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Fire Fighting
Issued 12 March 1990 Resolved
VESSEL NEEDS TO INSTALL FIXED FIRE FIGHTING SYSTEM IN ENGINE ROOM, CO2 OR HALON, EITHER HEAT ACTIVATED OR REMOTE PULL.
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Accommodation/Occupational Safety
Issued 20 September 1988 Resolved
COMPLETE PERMANENT REPAIRS TO MARINE SANITATION DEVICE AND NOTIFY THIS OFFICE WHEN UNIT IS OPERATIONAL.
Condition: Unknown
Due 20 September 1988
Resolved 20 September 1988
Documentation
Issued 20 September 1988 Resolved
VESSEL REQUIRED TO OBTAIN VALID FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 20 September 1988
Resolved 20 September 1988
Lifesaving
Issued 20 September 1988 Resolved
REPLACE GRAB LINES, 100 FOOT SEA PAINTER AND WEAK LINK ON BOUYANT APPARATUS.
Condition: Unknown
Due 20 September 1988
Resolved 20 September 1988
Lifesaving
Issued 20 September 1988 Resolved
VESSEL NEEDS REPLACEMENT OF COAST GUARD DISTRESS SIGNAL FLARES, OTHERS WEREOUTDATED. PROVIDE SIX NEW DAY AND NIGHT OR SIX COMBINATION.
Condition: Unknown
Due 20 September 1988
Resolved 20 September 1988