← All vessels
DON INNOVATION
Passenger (Uninspected) · Passenger Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named DON INNOVATION
DON INNOVATION is a 1971 passenger vessel (uninspected). The Coast Guard has recorded 74 inspections since 1984, most recently in May 2025, along with 167 deficiencies and 1 operational control.
Records from 1984 to 2025. Most recent: inspection, 20 May 2025.
- Built
- 1971
- Last inspected
- 20 May 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 167 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
532266
WDJ3296
46881
Flag
UNITED STATES
367766630
Maury page id
psix-46881
Inspections, by type
…with no type recorded6
Years with a record
36 calendar years (1984–2025)
The 74 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)33.8 ft × 12.8 ft × 5.3 ft
Registered tonnagegross 14 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · FORT LAUDERDALE FL · built 1971
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Net Ton
14 - Regulatory (Subpart C or D), Gross Ton
14 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ3296MMSI 367766630 · active · compulsorily equipped · granted 29 December 2016, expires 29 December 2026
WYZ3913MMSI 367141310 · expired · compulsorily equipped · granted 23 September 2006, cancelled 11 February 2017 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 74
20 May 2025
Uninspected Passenger Vessel
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8152774
18 February 2025
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8081273
12 March 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7865321
24 January 2024
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7857481
20 March 2023
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7652117
6 October 2022
Deficiency Check · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7572020
21 January 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7382528
3 March 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7149752
12 November 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7071449
25 June 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6985771
2 April 2019
DAPI Audit · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6651903
23 October 2018
Hull Examination · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6565571
16 February 2018
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6356358
16 October 2017
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6288517
2 November 2016
Hull Examination · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6033756
17 May 2016
DAPI Audit · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5886604
8 December 2010
Hull Examination · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3906552
19 February 2010
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3682202
15 January 2010
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3664439
8 December 2009
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3646835
5 November 2008
Drydock Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3387087
14 November 2007
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3098190
8 January 2007
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2851961
20 October 2006
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2804634
5 October 2006
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2794116
5 May 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2349711
22 December 2004
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2278511
10 November 2003
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1945221
16 September 2003
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1907031
16 September 2003
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2361096
26 January 2003
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1735467
6 November 2002
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1704682
1 May 2002
Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1611092
26 September 2001
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1469065
23 May 2001
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1379451
18 May 2001
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1064354
12 July 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1052027
4 January 2000
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 813753
1 December 1999
Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1420225
30 November 1999
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 812426
16 April 1999
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1117638
16 April 1999
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1410078
11 March 1999
Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 805771
19 February 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1388738
7 October 1997
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1427476
4 September 1997
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1390599
13 February 1997
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1359353
21 February 1996
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1459976
24 December 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1188919
13 September 1995
Hull Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1360258
5 April 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1167594
24 February 1994
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1449670
1 December 1993
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1379888
2 September 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 831431
10 March 1993
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1362743
16 June 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 952623
2 March 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1266449
16 January 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1259902
7 November 1991
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 948148
12 April 1991
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1211172
12 March 1991
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1219818
21 April 1990
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1216309
12 March 1990
COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 926384
27 September 1989
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1304939
8 March 1989
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1207339
24 October 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1203547
20 September 1988
Re-Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1200190
9 March 1987
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1323569
13 November 1986
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1316355
13 November 1986
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1328925
23 April 1986
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1306473
10 May 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1287276
27 March 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 980094
16 March 1984
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1328926
Deficiency record · 167
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 12 March 2024
Resolved
1. When operating a vessel on a body of water where the discharge of untreated sewage is prohibited, the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods include - (1) closing each valve and removing the handle; (2) padlocking each valve in the closed position; (3) Using a non-releasable wire tie to hold each valve in the closed position. Vessel has type III MSD system and system was not secured to prevent discharge.
33 CFR 159.7 (c)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 12 March 2024
Resolved
A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling water system. Vessel did not have a raw water hull strainer installed. Install strainer.
46 CFR 182.420(a)(2)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 January 2024
Resolved
Repairs or alterations to the machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement or repair, propulsion and systems; alterations affecting stability. The owner or managing operator shall submit written specifications describing the details of any proposed alterations to the cognizant OCMI for approval before work is started. The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Vessel main diesel engine was removed to be replaced for a new engine, without notifying USCG Inspections Office. 1. Provide specifications of existing and new engine to be installed for approval; 2. complete and submit the document Guidance for Repowering Vessels Inspected under 46 CFR Subchapter T with both engines specifications; 3. Prove proper operation of main diesel engine during sea trials prior to departure carrying passengers. 46 CFR 176.700, Code 17C.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 March 2023
Resolved
Repairs or alterations to equipment that affect the safety of the vessel must not be made without the approval of the OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include electrical wiring. The owner or managing operator shall submit drawings, sketches, or details of any proposed alterations to the cognizant OCMI. A new wiring diagram or electrical systems schematic is required.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 March 2023
Resolved
Machinery space boundaries. Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant. Found that the overhead area forward of the propulsion engine was missing the noncombustible panels.46 CFR 177.410(c )(4)
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 20 March 2023
Resolved
02107-The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Both the port and starboard hull fuel tank vents flame screens were partially blocked by paint.46 CFR 182.450
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 March 2023
Resolved
09112-A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.46 CFR 184.710
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 March 2023
Resolved
02108-Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: A pressure type connector on each conductor;
A solder lug on each conductor. Found in the forward cabin port side that two electrical terminal blocks had stranded wire connected directly without using pressure type terminal connectors.46 CFR 183.340(g)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 March 2023
Resolved
02108-Electrical equipment on a vessel must be installed and maintained to: Provide services necessary for safety under normal and emergency conditions; Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Minimize accidental personnel contact with energized parts. Found the following: (
a) Forward cabin port side, the two electrical terminal blocks and pressure type electrical connectors are corroded. Also there was no cover installed to prevent items stored in this area from shorting out the connects.
(b) Under the steering console, the clip type fuse panel and pressure type electrical connectors are corroded. (c) The propulsion engine battery selector switch connections are corroded.46 CFR 183.220
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2023
Resolved
CG204-Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. The following restrictions apply: Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose, or field attachable type fittings may be used. Hose end fittings must comply with SAE J-1475. Found no marking that fuel lines meets SAE J 1942 or had be spliced, and did not have connections meeting SAE J 1945. For all supply and return lines to the port and starboard fuel tanks. 46 CFR 172.720(g)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2023
Resolved
CG204-Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the supply line, at the tank connection. Found the handle for the shutoff valve located at the starboard fuel tank was loose and could not confirm the valve closed when the valve was operated by the remote pull.46 CFR 182.20-40(b)(3)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 March 2023
Resolved
02105-Except as further modified in this section all single screw vessel in ocean and coastwise service shall be provided with an auxiliary steering arrangement located above the weather deck. Found the auxiliary steering arrangement would not operate, there was no means to quickly disconnect the hydraulic ram from the rudder assembly.46 CFR 182.30-5(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2023
Resolved
11117-All vessels shall be fitted with one ring buoy of not less than 24 inches in diameter. Found following deteriorated, the line around the outside was diameter deteriorated and the retro tape. 46 CFR 180.30.5(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 March 2023
Resolved
03107-A hatch exposed to the weather must be watertight, have securing devices and be attached by hinges, captive chains or other devices or substantial strength to prevent its loss. Found that the port and starboard deck hatches located in way of the operating station not have captive devices to prevent their loss. 46 CFR 179.360
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 20 March 2023
Resolved
04110-Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Found that one of the two required portable battery lights was not operational.46 CFR 183.43
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 March 2023
Resolved
10109-The lights and shapes specified in these Rules shall comply with the provisions of Annex I of these Rules (33 CFR part 84.13(c). Found:
a. The fixture used as a stern light did not meet the requirements of having an unbroken light over an arc of the horizon of 135° and so fixed as to show the light 67.5° from right aft on each side of the vessel.
b. The means of turning on all around light (anchor light)is not separate from the rest of the navigation lights.46 CFR 183.43
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 March 2023
Resolved
02108-All electrical equipment and circuits must be clearly marked and identified. The individual fuses for the fuse panel were not marked showing load being serviced. Located on forward end, under the steering console.46 CFR 183.200(d)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 January 2022
Resolved
The marine employer must have a sufficient number of alcohol detecting testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the Serious Marine Casualty. Alcohol detecting swabs on board were found to be expired in YR2021, and lacking on an additional swab as one master and two deckhands are currently operating this vessel. Obtain an approve alcohol breathalyzer and/or current not expired alcohol swabs for all crew. 46CFR06-15
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 January 2022
Resolved
An Employee Assistance Program (EAP) must be conducted for the employer’s crewmembers and supervisory personnel. The training program must include at least the following elements: The effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crew members and employer’s supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Conduct an Employee Assistance Program training at all levels (master, deckhands and management supervisory level) and provide evidence of training.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 January 2022
Resolved
For each marine casualty required to be reported by 46CFR185.202, the vessel owner, master, or person in charge of the vessel shall determine whether there is any evidence of alcohol or drugs use by the individuals directly involved in the casualty. The owner, master or person in charge of the vessel shall include in the written report, Form CG-2692. Vessel captain failed to answer the correct reporting procedures in accordance of the regulation in how much time a alcohol or drug testing must be conducted after a marine casualty. Vessel captain must be trained and demonstrate knowledge in what are the conditions of a reportable marine casualty and timeframe for drug and alcohol testing for the satisfaction of an attending USCG Marine Inspector. 46CFR185.210.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 January 2022
Resolved
All vessels must carry adequate and up-to-date nautical charts. Vessel was found to have a nautical chart without evidence of being updated since 2007. Update nautical chart in accordance with all changes as provided in the publication called Noticed to Mariners. 46 CFR 185.20-35.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 21 January 2022
Resolved
Prepare and post emergency check-up list in a conspicuous place accessible to crew and passengers. Emergency checkup list may follow the recommended format in accordance with 46 CFR 185.25-5. Vessel was found not having posted emergency instructions or checkup list. Provide emergency instructions and post it in a conspicuous place accessible for passengers and crew. 46CFR185.25-1 and 46CFR185.25-5.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 January 2022
Resolved
A vessel on which a pre-engineered fixed gas fire system is installed must have a light to indicate discharge and an audible alarm that sounds upon discharge at the operating station. USCG Marine Inspector found that the visual light to indicate discharge was not operational. Replace the visual alarm and prove proper operation during testing of the system for the satisfaction of an attending USCG Marine Inspector. 46 CFR 181.420 (4)(b)(1).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 21 January 2022
Resolved
A hatch exposed to the weather must be weathertight and have securing devices. The following were found not to be weathertight and missing securing devices: a. forward hatch in front of the accommodation space, which is forward of the operating station; and b. center window right of the operating station.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 January 2022
Resolved
Compliance in all weathers. Rules concerning lights and shapes a vessel is required to have sidelights, means a green light on the starboard and a red light on the portside, a sternlight means a white light placed as nearly as practicable at the stern. Day shapes must have a ball, diamond, ball configuration. Vessel’s current navigation red and green lights lens was found faded by UV exposure, and sternlight inoperable. In addition, vessel did not have on board any dayshapes. Replace both red and green, and sternlight navigation lights with an approved type, and provide the day shapes. 33CFR83.20
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 March 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 3 March 2021
Resolved
Requirements of the Federal Communications Commission.
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. MMSI # Does not match up to certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2021
Resolved
All fuel tanks must be electrically bonded to a common ground. STB Side fuel tank not grounded.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 3 March 2021
Resolved
A hatch exposed to the weather must be watertight. Deck foaming has a 26” soft/water logged wood.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2021
Resolved
The marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever the condition of the shafting and bearings are in question.
Change clamps for shaft packing glans.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 June 2020
Resolved
Pre- engineered fire extinguishing systems must have a means to reset device used to automatically shut down the engine. Engine override switch does not operate. Vessel is restricted from carrying passengers.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 April 2019
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit Hydrostatic release for EPRIB is expired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 April 2019
Resolved
At each vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard or clog bilge pumping systems. Wiring in engine space is not secured and rests in the bilge.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 April 2019
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Railings block the visibility of port and starboard navigational lights. Navigational lights need to be in a location that does not prohibit the visibility and intensity of navigational lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019
Resolved
The connection fittings on the non-metallic hoses for the oil cooler for the transmission are severely corroded and require replacement in accordance with regulations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019
Resolved
In systems where flexible hoses are permitted to be clamped, two clamps must be used at each end of the hose. Flexible hose on engine cooling line needs to be readjusted and double clamped onto the though hull valve.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 April 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Coast Guard Light list and tide tables. Light list and tide tables for area of operation are out of date.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 27 March 2018
Resolved
Prove proper operation of engine room pre-engineered fire fighting system. Install proper sytem, the bottle is fyrework and the override switch is fireboy.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 February 2018
Resolved
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 February 2018
Resolved
properly install emergency steering.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 16 February 2018
Resolved
Provide alarm and lights for the bilge system
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 February 2018
Resolved
Properly install machinery guards on the exposed moving parts of the engine.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 16 February 2018
Resolved
Provide a garbage management plan for the vessel
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2018
Resolved
Repair the fuel line splice
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 February 2018
Resolved
Inspect and repair leak on the vessel's shaft.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 February 2018
Resolved
Provide proper amount of flashlights.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 16 February 2018
Resolved
Properly label distress signals watertight container with the words "DISTRESS SIGNALS"
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 16 February 2018
Resolved
Provide proper amount of distress signals
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 February 2018
Resolved
Provide appropriate first aid kit
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 February 2018
Resolved
properly label fire buckets with the words "FIRE BUCKET"
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 February 2018
Resolved
Relabel the lifebuoy with proper vessel name and hailing port
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2018
Resolved
provide proper stowage labeling for the adult and child life jackets
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2018
Resolved
replace retroreflective tape on 23 life jackets
01 - Certificates & Documentation › 013 - Documents › Fire safety operational booklet
Issued 16 February 2018
Resolved
provide proof of servicing of all three fire extinguishers and fireboy system
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 16 February 2018
Resolved
the captain of the vessel must provide proof of credentials
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 February 2018
Resolved
provide proof of the vessel's radiotelephony certificate
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 16 February 2018
Resolved
provide registration decal for EPIRB
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 16 February 2018
Resolved
provide updated information for the Employee Assistance Program and properly post in a common and accessible area
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 16 February 2018
Resolved
provide proof of all crew enrolled in a consortium or equivalent program
Engineering › Fuel Oil Service System › Piping
Issued 2 November 2016
Resolved
properly repair spliced supply fuel line.
Engineering › Bilge Water Management System › Pump
Issued 2 November 2016
Resolved
replace Rule 2000 electrical submersible bilge pumps with the UL listed type.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 November 2016
Resolved
properly repair rotted wood found on forward transverse bulkhead between engine compartment and forward accommodation space.
Construction/Loadline › Structures › Deck Plating
Issued 2 November 2016
Resolved
properly repair unfinished epoxy repair at transom.
Construction/Loadline › Structures › Deck Plating
Issued 2 November 2016
Resolved
properly close opening between the engine compartment and operating console.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 2 November 2016
Resolved
FRP structure (pulpit) that supports the anchor is wasted and needs repair.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 May 2016
Resolved
Replace 7 lifejackets. Vessel is restricted to 20 passengers until sufficient amount of approved preservers are provided.
Lifesaving › Lifebuoys › Serviceable
Issued 17 May 2016
Resolved
Replace life ring with approved type in serviceable condition. 46 CFR 180.70(a)(2)
Engineering › Fuel Oil Service System › Suction Strainer
Issued 17 May 2016
Resolved
Install approved marine grade fuel strainer. 46 CFR 182.455.
Communications › Radio Communications › Satellite Communications Capability
Issued 17 May 2016
Resolved
Program MMSI number in VHF-DSC Radio.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2016
Resolved
Provide 160.041 approved first aid kit and remove all expired items from the vessel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 December 2009
Resolved
Vessel was not made available for its annual inspection within 90 days before or following the anniversary of the issuance of its Certificate of Inspection rendering the COI invalid.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 5 November 2008
Resolved
Install and test properly functioning fireboy sysem. (engine shutdowns)
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 November 2007
Resolved
Provide rettrotape on all 4 child lifejackets.
Lifesaving › Lifefloat › Float Free
Issued 14 November 2007
Resolved
Provide float free lifefloat. (clean mildew of lifefloat)
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 November 2007
Resolved
Provide operational lifering light.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 8 January 2007
Resolved
Issued requirement to have all publications on board.
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 8 January 2007
Resolved
Issued requirement to replace all retro tape on life jackets.
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 January 2007
Resolved
Issued requirement to provide training and have maintenance log
Communications › Radio Communications › EPIRB
Issued 22 December 2004
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE OPERATIONAL EPIRB.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 22 December 2004
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE 18 PASSENGER BUOYANT APPARATUS.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 December 2004
Resolved
PRIOR TO CARRYING PASSENGERS, STENCIL STORAGE AREA OF CHILDREN AND ADULT LIFEJACKETS.
Engineering › Fuel Oil Service System › Valve
Issued 22 December 2004
Resolved
PRIOR TO CARRYING PASSENGERS, STENCIL REMOTE FUEL SHUT OFF VALVE.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 22 December 2004
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE 1 SERVICED B1 EXTINGUISHER.
Construction/Loadline › Hull › Transverse Frame
Issued 17 September 2003
Resolved
FOUND SIGN OF WOOD DRY ROT IN FRAMING INSIDE ENGINEROOM STBD SIDE. SUBMIT REPAIR PROPOSAL FOR REPLACEMENT OF DRY ROTTED FRAMING IN ENGINEROOM STBD SIDE TO MSO SAN JUAN.
Engineering › Sea-water System (primary cooling) › Valve
Issued 17 September 2003
Resolved
REMOVE ALL THRU HULL FITTING FOR INSPECTION
Construction/Loadline › Hull › Hull Plating
Issued 16 September 2003
Resolved
Remove all thru hull fittings for inspection.
Construction/Loadline › Hull › Longitudinal Frame
Issued 16 September 2003
Resolved
Submit repair proposal for replacement of dry rotted framing in engineroom stbd side overhead prior to placing vessel in dock.
Personnel › Training
Issued 6 November 2002
Resolved
50 % of the total crew must comply wit CPR/First Aid Training. training expired on 2001. LEGACY COMPONENT DESC: First Aid/CPR
Lifesaving › Lifejacket/PFD (General)
Issued 1 May 2002
Resolved
Replace retro tape on 2 PFDs LEGACY COMPONENT DESC: Marking
Lifesaving › Hand Flares
Issued 1 May 2002
Resolved
Remove expired pyro. LEGACY COMPONENT DESC: Storage
Communications › Radio Communications
Issued 1 May 2002
Resolved
Replace EPIRB battery. LEGACY COMPONENT DESC: EPIRB
Construction/Loadline
Issued 26 September 2001
Resolved
Repair/renew all delaminated spots on u/w hull and submit a detailed repairproposal prior to completion of work. This must be completed within 30 days or priort to re-launching vessel
Lifesaving
Issued 23 May 2001
Resolved
Replace retro-freflective tape on 03 child size lifejackets. Prior to next sail.
Engineering
Issued 23 May 2001
Resolved
Provide fire and impigment bowl for fuel filter.
Fire Fighting
Issued 23 May 2001
Resolved
Provide service report for fix and portable fire extinguishing systems.
Construction/Loadline
Issued 23 May 2001
Resolved
Ripair visual alarm for bilge high level alarm.
Lifesaving
Issued 1 December 1999
Resolved
Provide CG approved first aid kit.
Electrical
Issued 1 December 1999
Resolved
Rewire depth finder using connectors IAW 46 CFR 183.340.
Documentation
Issued 1 December 1999
Resolved
Provide CPR certification for at least 50% of the crew.
Unknown
Issued 1 December 1999
Resolved
Vessel is restricted to 15 passengers and 2 crew for a total of 17 persons,daylight hours only until SJ01, SJ04, SJ05, and SJ11 have been cleared.
Lifesaving
Issued 1 December 1999
Resolved
Properly mount EPIRB IAW manufacturers instructions.
Lifesaving
Issued 1 December 1999
Resolved
Provide light holder for ring buoy light and install.
Fire Fighting
Issued 1 December 1999
Resolved
Provide 3 each 3.5 gallon fire buckets with lanyards properly marked.
Lifesaving
Issued 1 December 1999
Resolved
Renew EPIRB Hydrostatic release mechanism. Provide copy of purchase recieptto MSO San Juan.
Documentation
Issued 1 December 1999
Resolved
Provide copy and post stability letter aboard vessel._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 1 December 1999
Resolved
Provide proof that all employees that operate vessel are enrolled in an approved system IAW 46 CFR 16.
Navigation
Issued 1 December 1999
Resolved
Repair compass light
Lifesaving
Issued 1 December 1999
Resolved
Provide 15 approved type I lifejackets, adult sized with retro tape to bring required amount to 32.
Fire Fighting
Issued 11 March 1999
Resolved
PROVIDE A COMPLETE AND OPERATIONAL FIXED FIRE FIGHTING SYSTEM IAW 46 CFR 181.400 NLT 11 APRIL 99.
Construction/Loadline
Issued 11 March 1999
Resolved
PROVIDE PLANS FOR INSTALLED BILGE HIGH LEVEL WARNING SYSTEM.
Lifesaving
Issued 19 February 1999
Resolved
CONDUCT FIRE AND ABANDON MAN OVERBOARD DRILL IN CG INSPECTORS PRESENCE
Documentation
Issued 19 February 1999
Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING ENROLLEMENT FOR ALL CREWMEMBERS.
Navigation
Issued 19 February 1999
Resolved
INSTALL OPERATIONAL BY PASS VALVE FOR EMERGENCY STEERING SYSTEM.
Engineering
Issued 19 February 1999
Resolved
DEMONSTRATE PROPER OPERATION OF MAIN DIESEL ENGINE.
Navigation
Issued 4 September 1997
Resolved
PROVIDE QUICK ACCESS TO RUDDER TILLER ARM TO FACILTATE EMERGENCY TILLER INSTALLATION
Deck/Cargo
Issued 4 September 1997
Resolved
RENEW ANCHOR RODE
Navigation
Issued 4 September 1997
Resolved
INVERT STEERING RAM TO TILLER BOLT SO THAT THE HEAD IS ON THE UPPER SIDE
Lifesaving
Issued 13 February 1997
Resolved
PROVIDE BRIGHT COLORED PORTABLE WATERTIGHT CONTAINER LABELLED "DISTRESS SIGNALS" FOR FLARES.
Lifesaving
Issued 13 February 1997
Resolved
PROVIDE LIFEJACKET PLACARD WITH DONNING INSTRUCTIONS.
Lifesaving
Issued 13 February 1997
Resolved
PROVIDE RETRO-REFLECTIVE TYPE II TAPE ON RING LIFEBUOY.
Lifesaving
Issued 13 February 1997
Resolved
PROVIDE FLOAT FREE MOUNTED FCC TYPE ACCEPTED CAT. 1 406 MHZ EPIRB.
Lifesaving
Issued 13 February 1997
Resolved
PROVIDE LOGBOOK WITH ENTRIES FOR ABANDON SHIP, FIREFIGHTINGDRILLS, EPIRB TESTS, AND LIFESAVING EQUIPMENT MAINTENCE.
Electrical
Issued 13 February 1997
Resolved
PROVIDE SECOND OPERABLE PORTABLE BATTERY LIGHT AT OPERATING STATION (FLASHLIGHT).
Documentation
Issued 13 September 1995
Resolved
Renew FCC Safety Certificate.
Accommodation/Occupational Safety
Issued 13 September 1995
Resolved
Remount blower by air compresser.
Fire Fighting
Issued 13 September 1995
Resolved
Service fixed Co2 flooding system.
Construction/Loadline
Issued 13 September 1995
Resolved
Crop and renew verticle support that has rot, located on bulkhead in front of air compresser.
Engineering
Issued 13 September 1995
Resolved
Fabricate and install hand guard on pulley on forward end of engine. (PTO to air compresser)
Construction/Loadline
Issued 13 September 1995
Resolved
Tighten elbow on sea suction line at sea cock.
Electrical
Issued 13 September 1995
Resolved
Remount air compresser.
Navigation
Issued 13 September 1995
Resolved
Turn bolt on steering quradant over so nut is on the down side.
Navigation
Issued 13 September 1995
Resolved
Repair or renew antenna mount
Navigation
Issued 13 September 1995
Resolved
Procure 6 each hand held orange smoke signals.
Lifesaving
Issued 13 September 1995
Resolved
Renew painter and grab lines on bouyant apparatus.
Engineering
Issued 13 September 1995
Resolved
Install cap or plug in fuel strainer petcocks.
Engineering
Issued 13 September 1995
Resolved
Repair diesel fuel leak in way of port fuel tank.
Navigation
Issued 13 September 1995
Resolved
Repair running lights.
Engineering
Issued 13 September 1995
Resolved
Renew or repair cracks in exhaust tube.
Navigation
Issued 13 September 1995
Resolved
Preform radio check after launching.
Lifesaving
Issued 13 September 1995
Resolved
Preform crew drills after launching.
Lifesaving
Issued 13 September 1995
Resolved
repair surface cracks on buoyant apparatus.
Documentation
Issued 13 September 1995
Resolved
Produce original Master's license.
Construction/Loadline
Issued 13 September 1995
Resolved
Renew screen in sea strainer.
Construction/Loadline
Issued 24 February 1994
Resolved
Replace main engine cooling water through hull fitting.
Engineering
Issued 24 February 1994
Resolved
Renew line to salt water transmission oil cooler.
Lifesaving
Issued 24 February 1994
Resolved
Renew retro reflective tape on lifejackets.
Lifesaving
Issued 10 March 1993
Resolved
Renew retroreflective tape on all PFD's as required. Vessel limited to daylight operatisn until retroreflective tape is replaced._x001C_
Documentation
Issued 10 March 1993
Resolved
Provide proof of drug testing program in accordance with 46 Code of FederalRegulations Subpart 16.
Fire Fighting
Issued 10 March 1993
Resolved
Provide approved fixed fire extinguishing system for engine room and properly insulate overhead with non combustible panels approved by 46 Code of Federal Regulations Subpart 164.009.
Lifesaving
Issued 7 November 1991
Resolved
REPLACE GRABLINE ON LIFERING WITH 3/8 INCH BUOYANT SYNTHETIC LINE HAVING A MINIMUM BREAKING STRENGTH OF 1,350 POUNDS IAW 160.050-4(C)._x001C_ _x001C_ _x001C_
Engineering
Issued 7 November 1991
Resolved
PROVIDE GUARD FOR PULLY ASSEMBLY ON AIR COMPRESSOR.
Accommodation/Occupational Safety
Issued 7 November 1991
Resolved
PROVIDE HAND RAILS AROUND VESSEL WHICH ARE MINIMUM OF 42" IN HEIGHT IN ACCORDANCE WITH 46 CFR 177.35(C)._x001C_ _x001C_ _x001C_
Electrical
Issued 7 November 1991
Resolved
REMOVE DEAD END WIRES IN FORWARD VOID._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 7 November 1991
Resolved
REWELD ALL FRACTURES ON PLATFORM ON STERN OF VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 7 November 1991
Resolved
PROVIDE PROTECTIVE GLOBE AND CAGE FOR LIGHTBULB LOCATED IN RESTROOM._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 7 November 1991
Resolved
LABEL BUOYANT APPARATUS WITH VESSEL'S NAME AND PERSON CAPACITY WITH MINIMUMOF 1 1/2" LETTERS IN ACCORDANCE WITH 46 CFR 180.20-5._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 7 November 1991
Resolved
MAKE PERMANENT REPAIRS TO OLD SINK OVERBOARD LOCATED ON STARBOARD SIDE._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 7 November 1991
Resolved
ENSURE BUOYANT APARATUS IS SECURED TO VESSEL BY A PAINTER AND A FLOAT FREE LINK IN ACCORDANCE WITH 46 CFR 180.20-1. ALSO ENSURE BUOYANT APPARATUS IF SECURED BY LASHINGS IS CAPABLE OF QUICK RELEASE, THIS MUST BE DONE PRIOR TORETURNING VESSEL TO SERVICE._x001C_
Unknown
Issued 7 November 1991
Resolved
MARK VESSEL NAME ON PORT BOW WITH MINIMUM OF 4" LETTERS._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 12 March 1991
Resolved
ATTACH RETROREFLECTIVE MATERIAL TO ALL LIFE PRESERVERS IN A ACCORDANCE WITH46 CODE OF FEDERAL REGULATIONS (CFR) SUBPART 180 25-25
Fire Fighting
Issued 12 March 1991
Resolved
SERVICE ALL PORTABLE AND FIXED FIRE EXTINGUISHERS AS PER REQUIREMENT OF 46 CFR 176 25-25_x001C_ _x001C_ _x001C_
Lifesaving
Issued 12 March 1991
Resolved
ATTACH PAINTER AND WEAK LINK TO BUOYANT APPARATUS IN ACCORDANCE WITH 46 CFR180 15-5_x001C_ _x001C_ _x001C_
Fire Fighting
Issued 12 March 1990
Resolved
VESSEL NEEDS TO INSTALL FIXED FIRE FIGHTING SYSTEM IN ENGINE ROOM, CO2 OR HALON, EITHER HEAT ACTIVATED OR REMOTE PULL.
Accommodation/Occupational Safety
Issued 20 September 1988
Resolved
COMPLETE PERMANENT REPAIRS TO MARINE SANITATION DEVICE AND NOTIFY THIS OFFICE WHEN UNIT IS OPERATIONAL.
Documentation
Issued 20 September 1988
Resolved
VESSEL REQUIRED TO OBTAIN VALID FCC RADIO SAFETY CERTIFICATE.
Lifesaving
Issued 20 September 1988
Resolved
REPLACE GRAB LINES, 100 FOOT SEA PAINTER AND WEAK LINK ON BOUYANT APPARATUS.
Lifesaving
Issued 20 September 1988
Resolved
VESSEL NEEDS REPLACEMENT OF COAST GUARD DISTRESS SIGNAL FLARES, OTHERS WEREOUTDATED. PROVIDE SIX NEW DAY AND NIGHT OR SIX COMBINATION.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.