MAURY USCG vessel records Sign in
← All vessels

SUGARFOOT

SUGARFOOT is a 1971 commercial fishing vessel. The Coast Guard has recorded 45 inspections since 1986, most recently in November 2015, along with 29 deficiencies.

Records from 1986 to 2015. Most recent: inspection, 1 November 2015.

Built
1971
Last inspected
1 November 2015
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WUZ2678
Flag
UNITED STATES
366968650, 367361070 (licence lapsed)
Maury page id
psix-46885

Inspections, by type

…with no type recorded4
Years with a record 27 calendar years (1986–2015)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)43.6 ft × 13.5 ft × 6.0 ft
Registered tonnagegross 24 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCON YOUNGQUIST BOAT WORKS · SEATTLE, WA, UNITED STATES · built 1971
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCRAIG, AK
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WUZ2678MMSI 367361070 · expired · compulsorily equipped · granted 5 June 2008, cancelled 13 October 2018
WYD8906MMSI 366968650 · expired · compulsorily equipped · granted 3 August 2004, cancelled 1 November 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 45

1 November 2015 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5758961
28 May 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4326043
28 July 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4096969
3 October 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3869123
8 May 2009 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3470215
24 April 2008 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3191132
4 April 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2901529
26 March 2007 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2895654
24 April 2006 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2632180
13 April 2005 Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2333321
16 April 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2050274
18 April 2003 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1776120
12 April 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1604020
18 April 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1429535
10 April 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1429534
10 April 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1450434
27 April 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1381552
19 April 1999 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1411856
26 January 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1463429
21 April 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1419933
15 January 1998 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 811472
10 April 1997 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1392652
18 May 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 225078
17 April 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1360500
21 April 1995 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1416121
7 April 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 857390
19 October 1993 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1154765
15 October 1993 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 838912
6 April 1993 Re-Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1354296
7 October 1992 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1251862
13 April 1992 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 942763
15 November 1991 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1244973
4 October 1991 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 942657
10 June 1991 Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 931275
17 April 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1212923
17 April 1991 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1225817
31 May 1990 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1211033
26 March 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 910203
6 February 1990 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1213985
4 August 1989 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1042337
1 June 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1200319
13 April 1988 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1203752
30 March 1988 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 996277
4 September 1986 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1304050
16 July 1986 Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1300551

Deficiency record · 29

Lifesaving › Buoyant Apparatus › Painter
Issued 8 May 2009 Resolved
Properly secure life floats lines(painter), in accoradance with 46 CFR 180.130, subpart D.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2009
Resolved 11 May 2009
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 8 May 2009 Resolved
Provide proper safety radio certificate/documentation onboard as part of the radiotelephone installation in accordance with 47 CFR 80.903, Subpart S.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2009
Resolved 14 April 2011
Resolution: MISLE states that a new certificate was issued in April of 2010.
Lifesaving › Buoyant Apparatus › Marking
Issued 8 May 2009 Resolved
Properly re-stencil vessel name on the life-float, in accordance with 46 CFR 185.604 (a)(2).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2009
Resolved 11 May 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 May 2009 Resolved
Properly label storage area where adult and children lifejackets are stored, in accordance with 46 CFR 180.78 (a)(5).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2009
Resolved 11 May 2009
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 24 April 2008 Resolved
Replace galley fuel oil service tank with approved tank or re plumb to main service tanks prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 28 April 2008
Resolution: Galley fuel oil system has been re-plumbed back to main tank and old leaking tank has been removed.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 24 April 2008 Resolved
Replace 02 worn life jackets with new type I PFD. Vessel is limited to 28 passengers until replaced.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2008
Resolved 28 April 2008
Resolution: Life jackets have been replaced with new type I pfd''s with lights.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 24 April 2008 Resolved
Battery boxes installed in machinery compartments need to have box covers installed.
Condition: Design Flaw
Due 5 May 2008
Resolved 28 April 2008
Resolution: Battery box covers have been installed.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 24 April 2008 Resolved
Renew gasket on steering hatch cover.
Condition: Improper/Lack of Maintenance
Due 5 May 2008
Resolved 28 April 2008
Resolution: gasket has been replaced with a new gasket.
Construction/Loadline › Structures › Deck Plating
Issued 4 April 2007 Resolved
Replace damaged deck at fuel shut-off on main deck to original condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 April 2007 Resolved
Replace all engine room raw water hoses from thru-hull opening to sea strainer.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2007
Resolution: Hoses replaced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 4 April 2007 Resolved
Make remote fuel shut off to engine room tank operable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2007
Resolution: Remote fuel shut off now operable.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 4 April 2007 Resolved
Install fuse in engine room fuel transfer pump electrical line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2007
Resolution: Fuse installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 April 2004 Resolved
Replace buoyant line for ring buoy.
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 17 April 2004
Lifesaving › Rigid Liferafts
Issued 16 April 2004 Resolved
Replace reflective tape on life float.
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 17 April 2004
Lifesaving › Lifejacket/PFD (General)
Issued 16 April 2004 Resolved
Vessel needs new life jacket donning placards.
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 17 April 2004
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 16 April 2004 Resolved
Light list and tide & current tables were missing.
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 17 April 2004
Lifesaving › Lifebuoys
Issued 21 April 2003 Resolved
New life ring is required on vsl. Owner states that damage to ring occured when ring was outside in the elements. owner will purchase new ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 23 April 2003
Resolution: purchused new life ring.
Lifesaving › Lifejacket/PFD (Type I)
Issued 21 April 2003 Resolved
Vsl has kaypok PFD's. Required to replace all 3 child pfd's with new. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 23 April 2003
Resolution: purchased new child PFD.
Documentation › Logs/Records
Issued 21 April 2003 Resolved
vsl does not maintain a bridge log. vsl will purchase bridge log and ensure that training is logged as well as lifesaving equipment maintainence. LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 23 April 2003
Resolution: purchased bridgelog.
Navigation › Collision/Grounding Avoidance
Issued 21 April 2003 Resolved
Vessel needs to purchase current 2003 Tide table and Tidal Current table books. Absolutely none on board. LEGACY COMPONENT DESC: Danger Messages
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 23 April 2003
Resolution: purchased new 2003 navigateion manuals.
Communications › Radio Communications
Issued 21 April 2003 Resolved
provide emergency broadcast plackerd and post in the bridge. LEGACY COMPONENT DESC: VHF Radiotelephone
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 April 2003
Resolved 23 April 2003
Resolution: provied emergency broadcast and posted in the bridge.
Engineering
Issued 15 October 1993 Resolved
REPAIR OR REPLACE PORT EXHAUST HOSE FOR THE MAIN ENGINE.
Condition: Unknown
Due 19 October 1993
Resolved 21 October 1993
Lifesaving
Issued 6 April 1993 Resolved
RENEW RING BUOY HAND HOLD LINE.
Condition: Unknown
Due 20 April 1993
Resolved 25 April 1993
Fire Fighting
Issued 6 April 1993 Resolved
HYDROSTATICALLY TEST THREE B-II (CO2) FIRE EXTINGUISHERS.
Condition: Unknown
Due 20 April 1993
Resolved 25 April 1993
Unknown
Issued 6 April 1993 Resolved
PROVIDE PROOF OF PARTICIPATION IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 20 April 1993
Resolved 25 April 1993
Construction/Loadline
Issued 4 October 1991 Resolved
RENEW THE BULWARKS, PORT AND STARBOARD WITH MATERIAL LIKE ORIGINAL. PERMANENT REPAIRS SHALL BE STARTED NO LATER THAN 15NOV91 AND COMPLETED PRIOR TO 30DEC91. VESSEL'S ROUTE SHALL BE RESTRICTED TO LAKES, BAYS AND SOUNDS UNTIL PERMANENT REPIRS ARE COMPLETED._x001C_
Condition: Unknown
Due 4 October 1991
Resolved 4 October 1991
Documentation
Issued 17 April 1991 Resolved
PROVIDE SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Construction/Loadline
Issued 17 April 1991 Resolved
PROVIDE POSITIVE MEANS OF CLOSURE FOR ENGINE COMPARTMENT HATCH.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Documentation
Issued 17 April 1991 Resolved
CONDUCT SIMPLIFIED STABILITY TEST. UNTIL TEST HAS BEEN SATISFACTORILY COMPLETED, MANNING SHALL BE LIMITED TO 1O PASSENGERS ON AN EXPOSED (COASTWISE) ROUTE. ALL OTHER ROUTES/CONDITIONS OF OPERATION MAY REMAIN AS STATED ON COI.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.