LEATHERJACK

LEATHERJACK is a 1998 offshore supply vessel. The Coast Guard has recorded 44 inspections since 1998, most recently in January 2026, along with 58 deficiencies — 1 with no resolution recorded — and 3 casualty investigations between 2002 and 2013.

Records from 1998 to 2026. Most recent: inspection, 21 January 2026.

Built
1998
Last inspected
21 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8765711 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH5376
468957
Flag
UNITED STATES
367627350
Maury page id
psix-468957

Inspections, by type

…with no type recorded4
Years with a record 22 calendar years (1998–2026)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)105.8 ft × 64.5 ft × 9.0 ft
Registered tonnagegross 168 / net 134
ITC dimensions (L × B × D)105.8 ft × 64.5 ft × 9.0 ft
ITC tonnagegross 497 / net 149
BuilderCONRAD INDUSTRIES- HULL · MORGAN CITY, LA, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it168 - Regulatory (Subpart C or D), Gross Ton
497 - Convention (Subpart B), Gross Ton
134 - Regulatory (Subpart C or D), Net Ton
149 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP9620MMSI 367627350 · active · compulsorily equipped · granted 15 January 2025, expires 15 January 2035
WDH5376MMSI 367627350 · expired · compulsorily equipped · granted 13 June 2014, cancelled 17 August 2024
WDD3519MMSI 367132570 · expired · compulsorily equipped · granted 1 August 2006, cancelled 1 October 2016
WCX9627MMSI 366744170 · expired · compulsorily equipped · granted 11 February 1998, cancelled 12 April 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CROSBY CHAMPION Towing Vessel · MISLE 3719 · 14 June 2002 · activity 1693690TRINMAR #202 Freight Barge · MISLE 19041 · 16 September 2000 · activity 2932LADY TEREA Towing Vessel · MISLE 440727 · 16 September 2000 · activity 2932

Inspection history · 44

21 January 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8285369
18 March 2025 Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8095877
17 March 2025 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8092680
17 April 2024 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7897118
24 April 2023 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7676793
1 February 2023 Examination of Repairs · Internal Structural Exam · Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7630375
13 December 2021 MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7366937
12 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7195600
26 February 2020 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6916302
7 February 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6906231
9 January 2020 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6886812
7 January 2019 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6606825
8 March 2018 MTSA Verification · Internal Structural Exam · Examination of Repairs · Annual Inspection · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6368609
21 February 2017 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6092068
15 February 2017 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6088681
17 February 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5816487
5 February 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5812594
14 February 2012 Deficiency Check · Examination of Repairs · Administrative Inspection · COI Inspection · Ballast Water Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4245476
14 January 2010 Re-Inspection · Hull Examination · Examination of Repairs · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3666069
21 December 2007 Examination of Repairs · Re-Inspection · Ballast Water Examination · Internal Structural Exam · MTSA Verification · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3119513
20 March 2007 Ballast Water Examination · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2891110
26 October 2006 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2808580
9 August 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2741481
8 August 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2739771
10 April 2006 Examination of Repairs · MTSA Verification · Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2621517
22 August 2005 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2493936
19 August 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2468090
9 August 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2456857
29 December 2004 Hull Examination · COI Inspection · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2265970
22 June 2004 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2107150
1 June 2004 Examination of Repairs · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2084739
15 May 2003 Periodic Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1794232
24 December 2002 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1721552
19 June 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1630654
14 June 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1693690
11 April 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428003
16 September 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2932
20 March 2000 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1395393
28 February 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815772
17 March 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1461119
15 December 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 807221
10 November 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808991
8 June 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424615
20 January 1998 Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375315

Deficiency record · 58

10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 21 January 2026 Resolved
Each vessel that relies on electricity to power the navigational equipment must be arranged so that the equipment can be energized from at least two sources of electricity. Vessel's electronic charts only had one source of electricity. 46 CFR 129.310(a)(1)(iv)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2026
Resolution: Electronic chart functional on emergency power.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 January 2026 Resolved
Fire main piping must be of a suitable corrosion-resistant material. Fire main piping outside the wheelhouse must be replaced due to the level of corrosion. 46 CFR 132.110(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2026
Resolution: Firemain piping replaced.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 21 January 2026 Resolved
The operator must secure each marine sanitation device in a manner which prevents discharge of treated or untreated sewage. Vessel's current configuration does not have an acceptable method of securing the device. 33 CFR 159.7
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2026
Resolved 23 January 2026
Resolution: Sewage discharge valve properly secured with lock.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 January 2026 Resolved
Each OSV must have, at the pilothouse, controls to monitor the pressure in the fire main. Vessel does not have a pressure gauge for the fire pump in the wheelhouse. 46 CFR 130.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2026
Resolved 23 January 2026
Resolution: Firemain pressure gauge in wheelhouse installed and functional.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 January 2026 Resolved
Each liftboat must have aboard an operating manual approved by the Coast Guard as complying with this section. Vessel's level indicator (tilt) alarm's visual alarm for 1.5 and 2.5 degrees was inoperable. 46 CFR 134.170(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2026
Resolved 23 January 2026
Resolution: Visual alarms for 1.5 and 2.5 degree level indicator (tilt alarm) fuctional.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 January 2026 No resolution recorded
Paint lockers and similar compartments must be constructed of steel or be wholly lined with steel. Paint locker was constructed of aluminum. Next dry dock inspection. 46 CFR 127.220(c)
Action required: 705 - Other - as specified
Due 31 March 2028
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 18 March 2025 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Medical certificates must be issued and will remain current for the following periods of time, unless otherwise noted on the certificate. Vessel was employing an individual who did not possess a valid medical certificate.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 March 2025
Resolution: Vessel replaced crew member in question.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 March 2025 Resolved
No vessel may be navigated unless it has in its service and onboard the crew complement required by the COI. Vessel had employed in its service an individual who did not possess a valid credential and therefore the vessel did not meet their minimum manning requirement as per the COI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 March 2025
Resolution: Vessel replaced crew member in question.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 March 2025 Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to protect crew members, offshore workers, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment. The starboard generator overspeed alarm and shutdown did not function as required. This is a repetitive occurrence which has been witnessed by the Coast Guard for two years in a row. Vessel to conduct trouble shooting and complete satisfactory test in the presence of USCG Inspectors.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 March 2025
Resolution: Tech found that bad wireing in the solinoid flapper valve was to blame for the failure. Problem corrected and satisfactory test witnessed by inspectors.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 18 March 2025 Resolved
Any discharge of oil or oily mixtures into the sea from a ship other than oil tanker or from machinery space bilges of an oil tanker is prohibited except: 4) ship has in operation oily-water separating equipment, a bilge monitor, bilge alarm, or combination thereof as required by part 115 subpart b of this chapter and 5) oily-water separating equipment is equipped with a 15 ppm bilge alarm; for US inspected ships. Vessel had oily-water in bilge area with an electric bilge pump with float switch that is directly connected to an overboard discharge. Vessel may not elevate or lower.Any discharge of oil or oily mixtures into the sea from a ship other than oil tanker or from machinery space bilges of an oil tanker is prohibited except: 4) ship has in operation oily-water separating equipment, a bilge monitor, bilge alarm, or combination thereof as required by part 115 subpart b of this chapter and 5) oily-water separating equipment is equipped with a 15 ppm bilge alarm; for US inspected ships. Vessel had oily-water in bilge area with an electric bilge pump with float switch that is directly connected to an overboard discharge. Vessel may not elevate or lower.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 March 2025
Resolution: Marine inspectors were unable to find evidence that oil was being discharged overboard through the suction line in question. Oil was not present and arrangements were in place to prevent oil intrusion into the containment when marine inspectors reattended
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2025 Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to protect crew members, offshore workers, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. The 480 Volt electrical panel in the starboard deck locker was missing protections against electrical hazards including fire and electrical shock. Vessel to repair or replace missing part to eliminate aforementioned risk.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2025
Resolution: Unit was repaired to prevent risk of shock and fire.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 March 2025 Resolved
Each portable fire extinguisher must be inspected and maintained to ensure that they are in good general condition. The hose attached to extinguishers at station 9 and 11 showed signs of deterioration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2025
Resolution: Hoses were replaced by third party tech.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 March 2025 Resolved
Nothing in this part shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the safety and seaworthiness of the vessel and the inspection procedures for marine-engineering systems contained in subchapter F of this chapter apply to the inspection of vessels regulated under subchapter L of 46 CFR. The fuel hose running to the port generator was in poor condition and in need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2025
Resolution: Damaged fuel hose was replaced.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 18 March 2025 Resolved
Each alarm required by 46 CFR 130.460 must be of the self-monitoring type that will both show visibly and sound audibly. The alarm panel on the bridge and one of the two alarm panels in the engine room did not display all of the required visual indicators.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 19 March 2025
Resolution: Non-functional lights were replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 18 March 2025 Resolved
The owner of a vessel shall ensure that such vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel's master key. Vessel was not equipped with a master key control system. 46 USC 3106(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 19 March 2025
Resolution: Vessel received a master key control system from the company.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 18 March 2025 Resolved
Each crew berthing area shall be equipped with information on the procedures and resources to report crimes, including sexual assault and sexual harassment. Reporting procedures and resources for sexual assault and sexual harassment were not posted in crew berthing. 46 USC 11101(5)(B)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 19 March 2025
Resolution: Required information was posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 March 2025 Resolved
The owner or operator of a non-tank vessel must review the vessel response plan (VRP) annually. This review must occur within 1 month of the anniversary date of Coast Guard approval of the VRP. Vessel did not submit evidence of review to the USCG. 33 CFR 155.5070(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 19 March 2025
Resolution: Required evidence was reviewed and found satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 March 2025 Resolved
An owner or operator of a ship to which this subpart applies must review the shipboard oil pollution emergency plan annually and submit a letter to Commandant (CG-MER) certifying that the review has been completed. This review must occur within 1 month of the anniversary date of Coast Guard approval of the plan. Vessel did not submit evidence of review to the USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 19 March 2025
Resolution: Required evidence was reviewed and found satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 March 2025 Resolved
Each vessel assigned a loadline must have loadline markings and deck-line markings permanently scribed or embossed as required by subchapter E of this chapter. The vessel’s deckline was found to be painted the same color as the hull. Vessel crew painted the deckline white, contrasting the dark hull. Deficiency rectified.
Action required: 10 - Deficiency Rectified
Due 18 March 2025
Resolved 18 March 2025
Resolution: Vessel corrected painted color of deck line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 April 2023 Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to protect crew members, offshore workers, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment. The starboard generator overspeed alarm and shutdown did not function as required. Complete troubleshooting on automation, ensuring the function. 46CFR129.410(d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 May 2023
Resolution: Satisfactory overspeed tests conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 April 2023 Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to protect crew members, offshore workers, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment. The windings on both generators are caked with dust and dirt, presenting a fire hazard. The shrouds on both generators are damaged presenting a personnel hazard. Replace/repair shrouds and clean the generator windings. 46CFR129.200(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 May 2023
Resolution: Shrouds renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 April 2023 Resolved
Each OSV must carry at least one rescue boat and must be approved under approval series 160.156. Vessel’s crew experienced difficulties starting the engine. Conduct assessment and complete needed repairs. 46CFR133.135(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 May 2023
Resolution: Crew conducted test of rescue boat motor. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 April 2023 Resolved
Each OSV must carry at least one rescue boat. Propeller on outboard engine displayed impact damage resulting in a missing portion and crack on the flukes. Renew/repair propeller. 46CFR133.134(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 May 2023
Resolution: Propeller for motor was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 April 2023 Resolved
Each OSV must carry lifebuoys approved under approval series 160.150 or 160.050. Retroreflective tape on numerous ring buoys was found improperly installed. Renew type I retroreflective tape. 46CFR133.70(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2023
Resolution: Retro Renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 April 2023 Resolved
Each lifejacket must be marked with type I retro-reflective material approved under approval series 164.018.Retroreflective tape on numerous lifejackets was found wasted. Renew type I retroreflective tape. 46CFR133.70(b)(3)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2023
Resolution: Retro renewed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 April 2023 Resolved
Each vessel must be designed and constructed to minimize fire hazards, as far as reasonable and practicable. MI observed that the bulkhead between the deck locker and the laundry room / upper engine room was not gas tight. 46CFR127.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2023
Resolution: Cable penetration has been sealed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 April 2023 Resolved
Drug testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in the Serious Marine Incident (SMI). The collection of drug-test specimens of each individual must be conducted within 32 hours of when the SMI occurred. MI observed that the vessel did not have means onboard to conduct drug testing within 32 hours from an SMI. 46CFR4.06-3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 May 2023
Resolution: Vessel provided proof of drug testing equipment.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 April 2023 Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil, hazardous material, or liquefied gas as regulated in Table 4 of 46 CFR part 154 shall provide transfer procedures that meet the requirements of this part and part 156 of this chapter for transferring—(a) To or from the vessel; and (b) From tank to tank within the vessel. MI observed that the total tank capacity of the vessel was greater that 250 barrels yet they did not have oil transfer procedures onboard. 33CFR155.720
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2023
Resolution: Transfer procedures were provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 April 2023 Resolved
Each vessel must be designed and constructed to minimize fire hazards, as far as reasonable and practicable. MI observed significant grease build up in the galley exhaust hood. 46CFR127.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2023
Resolution: Excessive grease was cleaned.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 12 April 2023 Resolved
Each lighting fixture in an electrical system operating at more than 50 volts must comply with UL 595. There are cracks on the light cover in the galley. Replace light cover. 46 CFR 129.410(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2023
Resolution: Light covers renewed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 April 2023 Resolved
AIS must be maintained in effective operating condition which includes the accurate broadcast of a properly assigned MMSI number. The vessel does not have their current MMSI number programed into their AIS or VHF radio. Update the MMSI number in the AIS and VHF to match the current MMSI number for vessel. 33CFR164.46(d)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2023
Resolution: MMSI updated on AIS.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 April 2023 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel under way. MI observed that the refrigerators, washers, and dryers were not secured. 46CFR129.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2023
Resolution: Appliances secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2023 Resolved
At least one lifebuoy on each side of the OSV fitted with a buoyant lifeline that is resistant to deterioration from ultraviolent light. Buoyant lifeline on second deck STBD ring buoy was wasted. Renew lifeline. 46cfr133.70(a)4(i)(E)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2023
Resolution: Ring buoy line was renewed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage comminuting and disinfecting system
Issued 1 February 2023 Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable Type II device. The MSD aerator is inoperable and the vessel owner is utilizing the wrong chlorine tablets, minimizing the MSDs functionality. Repair aerator and urchase/utilize approved tablets per manufacturers manual. 33CFR159.7(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2023
Resolution: Aerator renewed; operating properly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 February 2023 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel under way. The electrical connections of all of the engineering alarm panels are loose. Tighten the electrical connections. 46CFR129.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2023
Resolution: Connections were tightened. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2021 Resolved
If your vessel's COI is renewed less often than annually, the MI must check the setting of the safety or relief valves on all pressure vessels, twice every 5 years; relief device was missing servicing information.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2021
Resolved 20 May 2021
Resolution: Vessel installed new pressure relief devices that had proof of servicing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 May 2021 Resolved
Each box for a small battery installation must have openings near the top to allow escape of gas. If the installaiton is in a non-environmentally controlled location, the installation must prevent the ingress of water; battery box for the the port generator had water intrusion.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 13 May 2021
Resolution: Battery box was cleaned out and free of water inside.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 May 2021 Resolved
In addition to the design requirements of paragraph (a), each crane must have the following: Instruments with built-in lighting; boom pressure gauge was not readable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 20 May 2021
Resolution: Vessel rep sent picture of newly installed gauge that was legible.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 February 2020 Resolved
A person may not employ or engage an individual in a position required to hold an MMS unless that individual maintains a current medical certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2020
Resolved 26 February 2020
Resolution: MMC Medical Certificate was renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 23 August 2018 Resolved
Anchor chain was seized together in anchor box not allowing for proper deployment. Anchor chain to be pulled from deck storage box and exercised. Pelican hook holding anchor to vessel to also be replaced. 46 CFR 130.240
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2018
Resolved 24 August 2018
Resolution: Chain exercised and pelican hook replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 August 2018 Resolved
Vessel equippped with fixed pitched propellers must have on the nav bridge a propeller speed and direction indicator for each shaft. Starboard shaft tachometer was inoperable. 46 CFR 113.37-5.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2018
Resolved 24 August 2018
Resolution: Tachometer was repaired and reading correctly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 23 August 2018 Resolved
Draft marks worn on bow. Each vessel must have the drafts of the vessel plainly and legibly marked upon the stern. 46 CFR 131.720
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2018
Resolved 24 August 2018
Resolution: Draft marks were cleaned.
Lifesaving › Lifefloat › Lifeline
Issued 15 February 2017 Resolved
The lifelines on the starboard side lifefloat were deteriorated and un-serviceable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2017
Resolution: Lifefloat was repaired.
Lifesaving › Lifefloat › Serviceable
Issued 29 March 2012 Resolved
Port lower lifefloat had damage exposing floatation material.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2012
Resolution: Replaced.
Documentation › Markings/Placards › Warning Signs
Issued 29 March 2012 Resolved
Markings for centerline WTD between enginerooms were missing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2012
Resolution: Markings installed.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 1 June 2004 Resolved
Provide oily waste pump and deck connection per 33 CFR 155.420.
Action required: 705 - Other - as specified
Due 4 July 2004
Resolved 22 June 2004
Resolution: provided.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 1 June 2004 Resolved
Provide corrected fire safety plan for approval.
Action required: 705 - Other - as specified
Due 4 July 2004
Resolved 22 June 2004
Resolution: provided
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 1 June 2004 Resolved
Provide corrected operations manual to include leg flooding conditions and hurricane actions, for approval.
Action required: 705 - Other - as specified
Due 4 July 2004
Resolved 22 June 2004
Resolution: provided.
Fire Fighting › Structural - Horizontal Zones
Issued 15 May 2003 Resolved
Install approved deck penetration block iwo E/R overhead (electrical penetration).
Due 15 June 2003
Resolved 27 May 2003
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 15 May 2003 Resolved
Re-paint load line deck mark.
Due 15 May 2003
Resolved 15 May 2003
Engineering › Bilge Water Management System
Issued 15 May 2003 Resolved
Replace faulty bilge high-water alarm.
Due 15 May 2003
Resolved 15 May 2003
Engineering › Fuel Oil Service System › Piping
Issued 15 May 2003 Resolved
Stanch leak in port M/E diesel fuel piping.
Due 15 May 2003
Resolved 15 May 2003
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 15 May 2003 Resolved
Install flame screen in lube oil vent pipe.
Due 15 May 2003
Resolved 15 May 2003
Engineering
Issued 19 June 2002 Resolved
Provide for approval, automation test procedures as per 46 CFR 130.480. LEGACY COMPONENT DESC: automation test procedures
Condition: Unknown
Due 26 July 2002
Resolved 26 July 2002
Resolution: On 15 MAY 03, examined automation test procedures stamped "Approved" by MORMS, and dated 26 JUL 02.
Engineering
Issued 19 June 2002 Resolved
Install shaft tachs as per 46 CFR 113.37.5. LEGACY COMPONENT DESC: shaft tachs
Condition: Unknown
Due 20 January 2003
Resolved 15 May 2003
Resolution: Verified installation.
Electrical
Issued 11 April 2001 Resolved
REPLACE FIRE MAIN PRESSURE GUAGE ON BRIDGE.
Condition: Unknown
Due 14 May 2001
Resolved 17 May 2001
Lifesaving
Issued 11 April 2001 Resolved
REPLACE KNOTTED EMBARKATION LINES WITH LADDERS. LADDERS MUST BE 25 FEET TO ACCOUNT FOR VESSEL'S OPERATIONS AIR DRAFT.
Condition: Unknown
Due 11 May 2001
Resolved 1 June 2001
Documentation
Issued 8 June 1998 Resolved
Provide approved structural fire protection plans to cognizant OCMI.
Condition: Unknown
Due 8 June 1998
Resolved 8 June 1998

Casualty record · 3

14 June 2002Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1693690
10 May 2013Routine · role: Involved in a Marine Casualty · activity 4588413
12 May 2013Routine · role: Involved in a Marine Casualty · activity 4622984
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

LAB LIFT III (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.