MSC YUVIKA V

MSC YUVIKA V is a 1997 freight ship. The Coast Guard has recorded 13 inspections since 2023, most recently in May 2025, along with 15 deficiencies and 4 operational controls.

Records from 2023 to 2025. Most recent: inspection, 26 May 2025.

Built
1997
Last inspected
26 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 May 2025
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2023–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9141285
469005
Flag
LIBERIA
Maury page id
psix-469005

Documentation record

Tonnage as PSIX records it53324 - Convention (Subpart B), Gross Ton
55515 - Dead Weight, Metric Ton
82496 - Displacement, Metric Ton
30816 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

13 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

26 May 2025 PSC A
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8143289
23 February 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8083093
15 February 2025 PSC A
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8076623
10 November 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8032858
4 August 2024 PSC A · Appeal · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7973335
3 May 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7905854
30 April 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7904085
30 April 2024 COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7904094
5 December 2023 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7833200
5 December 2023 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7834057
5 December 2023 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7839048
4 December 2023 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7834086
1 December 2023 Deficiency Check · PSC A · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7831965

Deficiency record · 15

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 4 August 2024 Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the Company. The technical and/or operational nature of deficiencies 02-08 provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency. 74 SOLAS (20)IX/3.1 ISM CODE 10.1
Action required: 30 - Ship detained
Resolved 6 August 2024
Resolution: DNV conducted ISM audit on 05AUG2024. Please see attached audit report for further details.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 August 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed rescue boat engine inoperable. 74 SOLAS (97) III/19.2
Action required: 30 - Ship detained
Resolved 6 August 2024
Resolution: Crew replaced ignition coil. Engine tested sat after repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 August 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed the remote control release cable and brake for the port side lifeboat improperly installed and seized in place by paint preventing the brake from stopping the lifeboat during lowering evolution. 74 SOLAS (97) III/19.2
Action required: 30 - Ship detained
Resolved 6 August 2024
Resolution: Third party technician attended vessel and overhauled brake.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 August 2024 Resolved
1 The fire resistance of doors shall, as far as practicable be equivalent to that of the division in which they are fitted. Doors and door frames in "A" class divisions shall be constructed of steel. Doors in "B" class divisions shall be non-combustible. Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. 2 Doors required to be self-closing shall not be fitted with holdback hooks. However, hold-back arrangements fitted with remote release devices of the fail-safe type may be utilized. PSCO observed galley doors, fitted with remote releases, held open with hold back hooks. Additionally, PSCO observed both water tight doors to engine room fitted with hold back hooks. Finally, PSCO observed self-closing doors within main stairwell to engine room, upper deck, C-deck PD/CD, nav bridge PD/CD, and engine room workshop escape trunk unable to close properly. 74 SOLAS (97) II-2/47.1 & 2
Action required: 30 - Ship detained
Resolved 6 August 2024
Resolution: Crew removed hold backs and adjusted self closing doors. Tested sat in presence of DNV surveyor.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 4 August 2024 Resolved
All the steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the Administration. PSCO observed active hydraulic oil leaks from all 4 hydraulic rams, hydraulic oil tank, and #1 servo pump. Crew fabricated drip pans to contain leaks. 74 SOLAS (97) II-1/29.2.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2024
Resolution: Crew replaced gaskets and tightened bolts. Steering gear tested leak free in presence of DNV surveyor.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 August 2024 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, PSCO observed active oil leaks and accumulating oil around M/E circulating pump, F/O booster pump, fuel oil purifiers, lube oil pumps, aux engine fuel tank, auxiliary engine #2, and all cylinder heads and fuel pumps on the main engine. 74 SOLAS (04) II-2/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2024
Resolution: Crew cleaned leaks to satisfaction of attending DNV surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 4 August 2024 Resolved
Each lifeboat shall be launched with its assigned operating crew aboard and maneuvered in the water at least once every three months, As far as is reasonable and practicable, rescue boats other than lifeboats which are also rescue boats shall be launched each month with their assigned crew aboard and maneuvered in the water. In all cases this requirement shall be complied with at least once every three months. PSCO observed both lifeboats and standalone rescue boat were last lowered and maneuvered in the water in April. 74 SOLAS (97) III/18.3.6 & 7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2024
Resolution: Vessel lowered port lifeboat and rescue boat in port. Vessel lowered starboard (inboard) lifeboat at anchorage prior to departing COTP zone.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2024 Resolved
The rating or appropriate setting of the overload protective device for each circuit shall be permanently indicated at the location of the protective device. PSCO observed circuit breaker setting for multiple breakers on main switchboard in engine control room missing/illegible. 74 SOLAS (97)II-1/45.6.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 November 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 August 2024 Resolved
The master, owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks that operates in the waters of the United States must follow these practices: (g) Maintain a ballast water management (BWM) plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's BWM strategy and comply with the requirements of this subpart. The plan must include— (6) Detailed reporting requirements and procedures for ports and places in the United States where the vessel may visit. The vessel's Ballast Management Plan does not mention US ballast requirements. 33 CFR 151.2050(g)(6)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 November 2024
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 4 August 2024 Resolved
No person may cause a vessel to enter into or get underway on the navigable waters of the United States unless no more than 12 hours before entering or getting underway, the following equipment has been tested:(1) Primary and secondary steering gear. The test procedure includes a visual inspection of the steering gear. PSCO observed records of pre-arrival checks omitting oil leaks and fabricated drip pans on steering gear. 33 CFR 164.25(a)(1)
Action required: 10 - Deficiency Rectified
Resolved 4 August 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 December 2023 Resolved
Provision shall be made to facilitate cleaning, inspection, and maintenance of main propulsion and auxiliary machinery. PSCO observed significant fuel oil accumulation and leaks found on three of the injectors on the main engine. Additionally fuel oil leaks were identified on ship's generators- to include lubricated oil leaks and pooling beneath generators. 74 SOLAS (04) II-1/26.7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2023
Resolution: Reference Class Report. PSCDO conducted admin defcheck to the DNV Class Report Attached.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 1 December 2023 Resolved
Any required fire detection and fire alarm system shall be capable of immediate operation at all times. PSCO observed failed test on incinerator smoke detector. Additionally observed fault code for fire alarm system, indicating that detector is inoperable. 74 SOLAS (97) II-2/12.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2023
Resolution: Reference Class Report. PSCDO conducted admin defcheck to the DNV Class Report Attached.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 1 December 2023 Resolved
For determining the appropriate fire integrity standards to be applied to division between adjacent spaces, such spaces are classified according to their fire risk as shown in Categories (I) to (II). Table 44.1 requires an A-60 boundary between a machinery space of Category A and a space for the stowage of flammable liquids. PSCO observed bunker samples being stored within the engine room with no boundary between them. 74 SOLAS (97) II-2/44.2.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 December 2023 Resolved
Fire extinguishing appliances shall be kept in good order and be available for immediate use at all times. PSCO observed extinguisher located in air conditioning room missing October and November 2023 inspections. 74 SOLAS (97) II-2/21
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 1 December 2023 Resolved
Oil filtering equipment referred to in Paragraph 2 of this regulation shall comply with Paragraph 6 of this regulation. PSCO observed oil content meter not intact. MARPOL I/14.7
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2023

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.