MAURY USCG vessel records Sign in
← All vessels

BILL OF RIGHTS

BILL OF RIGHTS is a 1971 passenger vessel (inspected). The Coast Guard has recorded 98 inspections since 1985, most recently in June 2025, along with 202 deficiencies, 1 operational control and 2 casualty investigations between 2005 and 2012.

Records from 1985 to 2025. Most recent: inspection, 24 June 2025.

Built
1971
Last inspected
24 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH2461
Flag
UNITED STATES
338151000
Maury page id
psix-46912

Inspections, by type

…with no type recorded11
Years with a record 38 calendar years (1985–2025)
The 98 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)89.6 ft × 23.8 ft × 9.6 ft
Registered tonnagegross 95 / net 87
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHARVEY F GAMAGE SHIPBUILDER INC · SOUTH BRISTOL, ME, UNITED STATES · built 1971
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHULA VISTA, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 August 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
87 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP7675MMSI 338151000 · active · compulsorily equipped · granted 17 August 2024, expires 17 August 2034
WDH2461MMSI 338151000 · expired · compulsorily equipped · granted 7 December 2013, cancelled 10 February 2024
WDE6817MMSI 367385250 · expired · compulsorily equipped · granted 19 November 2008, cancelled 16 February 2019
WCX8898MMSI not assigned · expired · compulsorily equipped · granted 22 December 1997, cancelled 19 April 2008
WTF3528MMSI not assigned · expired · compulsorily equipped · granted 6 October 1997, cancelled 9 February 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 98

24 June 2025 Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8166595
5 September 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7996473
6 August 2024 Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7975357
24 June 2024 Internal Structural Exam · Drydock Extension
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7941545
26 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7723830
26 June 2023 Deficiency Check · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7725985
26 June 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7774546
13 June 2022 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7491538
17 May 2022 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7452922
16 July 2021 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7261364
28 May 2021 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7209207
17 November 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7097649
15 July 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7005142
9 March 2020 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6923461
7 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6830126
27 June 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6727308
27 June 2018 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6436352
18 April 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6409530
14 August 2017 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6240813
21 March 2017 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6108712
31 May 2016 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5892476
28 July 2015 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5198657
30 May 2014 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4874627
29 May 2012 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4306214
27 September 2011 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4306193
8 April 2009 Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3444552
18 March 2009 Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3444140
3 November 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3348290
15 June 2007 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2966172
30 May 2007 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2939511
20 February 2007 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2874527
27 January 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2574670
27 June 2005 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2404514
2 June 2005 Attraction Vessel Exam · Excursion Permit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2377438
21 April 2005 Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 2340191
14 April 2005 Type not recorded
No type recorded · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2523315
21 March 2005 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2315956
24 January 2005 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2278206
7 January 2005 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2270788
16 November 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2238680
31 October 2003 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1939650
23 October 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1932233
8 February 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1747187
30 October 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1698399
2 October 2002 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1683306
19 November 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1075755
5 November 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1366645
4 April 2001 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1059850
17 October 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1391394
18 October 1999 COI Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1440211
21 June 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1449193
11 March 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 805128
6 February 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375635
29 January 1999 Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 790259
11 January 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1438763
11 September 1998 Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 799151
24 May 1998 Inclining Experiment
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1127487
10 March 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 789113
18 December 1997 Re-Inspection · Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1375214
29 April 1997 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1094642
30 October 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 13671
28 October 1996 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1356014
18 October 1996 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 855355
14 February 1996 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1188135
13 October 1995 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1448733
25 October 1994 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 868950
13 October 1994 MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1411048
29 July 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 146856
6 October 1993 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1164479
14 April 1993 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1142946
13 October 1992 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1401642
3 June 1992 Excursion Permit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 947955
22 April 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 953304
19 December 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1265152
29 November 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 942601
15 October 1991 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1407052
10 October 1991 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1247693
30 August 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1251779
1 July 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 937067
31 October 1990 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 919024
5 October 1990 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 930990
3 October 1990 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1242599
10 September 1990 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 905624
23 February 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 926259
22 January 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1240843
17 January 1990 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 920170
15 November 1989 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1223410
19 September 1989 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1197774
12 September 1989 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 895247
9 February 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1344767
5 January 1989 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1196012
15 November 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 894127
19 July 1988 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 898688
9 March 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1029673
2 February 1988 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1034923
24 July 1986 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1307232
10 June 1986 Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1310818
3 June 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1291583

Deficiency record · 202

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2025 Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. Vessels inner bob-stay, jib haul out, and hardware in way of bowsprit bob-stay/whisker-stays were found broken, damaged, or corroded during inspection. Vessel is required to make all required repairs and provide third party survey attesting to condition of all rigging prior to hauling any sails or getting underway with passengers on board. Cite: 46 CFR 177.330.
Action required: 705 - Other - as specified
Resolved 21 August 2025
Resolution: Survey completed and necessary repairs completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 September 2024 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. MI found expired FCC Station license. Crew has already ordered an new one. Send new certificate to [email withheld] once received.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2024
Resolved 25 March 2025
Resolution: MI attended vessel. ALL SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 September 2024 Resolved
Found a bulkhead penetration in the engine room that was not sealed and would allow the fixed firefighting to escape outside. Seal bulkheaded penetration with approved material and notify local OCMI when repairs are completed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 25 March 2025
Resolution: MI attended vessel. ALL SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 September 2024 Resolved
Each collision bulkhead must be maintained watertight. MI found collision bulkhead was not maintained watertight as plug was missing from a pipe. Put cap on pipe to make collision bulkhead watertight and notify local OCMI for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 25 March 2025
Resolution: MI attended vessel. ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 September 2024 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Vessel is missing four adult life jackets at the port and STBD storage location, midship and two in the captain’s cabin. Vessel is to replace life jackets w/ approved whistle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2025
Resolution: MI attended vessel. ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 September 2024 Resolved
Vessel pyrotechnic distress signals were all expired. Vessel is to replace all pyrotechnic distress signals (6 red and 6 orange) or 12 combination hand flare and smoke.
Action required: 10 - Deficiency Rectified
Resolved 5 September 2024
Resolution: Vessel got new flares. ALL SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 September 2024 Resolved
Observed dead-end wires located FWD of the engine room (portside and by muffler). Vessel is to terminate wires in a terminal box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2025
Resolution: MI attended vessel. ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 September 2024 Resolved
Observed A-compartment bilge pump not operational. Vessel to repair pump prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2025
Resolution: MI attended vessel. ALL SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 September 2024 Resolved
Observed rotting wood on Mast mast step. Vessel is to have the mast step available for further inspection underneath the mast. Vessel is to provide a repair plan prior to repairs.
Action required: 705 - Other - as specified
Resolved 25 March 2025
Resolution: MI attended vessel. ALL SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 September 2024 Resolved
Vessel provide a repair plan to use a wire brush and vacuuming up rotten wood. Vessel can try this plan but is not aloud to have any passengers, no other persons onboard except necessary crew to facilitate repairs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: MI attended vessel. ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 June 2023 Resolved
All escape hatches and other means of escape must be marked on both sides "EMERGENCY EXIT, KEEP CLEAR". Vessel's emergency escapes are not marked on both sides. Install adequate signage for emergency escapes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2023
Resolved 17 July 2023
Resolution: New signs were installed in required areas.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 June 2023 Resolved
Vessel diesel generator found to have fuel filter installed incorrectly (upside down) Install filter with flame bowl on the bottom.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2023
Resolved 17 July 2023
Resolution: Reinstall with correct orientation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2023 Resolved
Fuel line from filter to engine found to have incorrect connection. Install J-1942 approved fuel line with J-1942 approved connections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2023
Resolved 17 July 2023
Resolution: Appropriate hoses have been installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2023 Resolved
Distribution panel IWO engine room found to have wasted door. Replace hinge and make latch operable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2023
Resolved 17 July 2023
Resolution: Door was permanently mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2023 Resolved
Wiring IWO engine room found to not be securely mounted. Install wire supports no more than 12 inches apart.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2023
Resolved 17 July 2023
Resolution: Wires properly mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2023 Resolved
Battery bank on deck found to be installed without a battery box or securing mounts. Provide a protective battery box and secure to prevent movement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2023
Resolved 17 July 2023
Resolution: Batteries placed in battery boxes.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 June 2022 Resolved
Vessel found to have missed annual inspection window. Schedule COI inspection.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 July 2022
Resolution: Issued COI Renewal certificate on this date.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 June 2022 Resolved
EPIRP hydrostatic release found to be expired. Vessel restricted to Lakes, Bays, Sounds until new hydrostatic release is installed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 13 July 2022
Resolution: Vessels hydrostatic release was found to be replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2022 Resolved
Both ring buoys found to have wasted lanyards. Replace lanyards with approved material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2022
Resolved 13 July 2022
Resolution: Both ring buoys found to have had the lanyards replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 June 2022 Resolved
STBD water light mount found to be loose. Install mount to prevent movement while underway.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2022
Resolved 13 July 2022
Resolution: STBD water light mount found to be replaced and operational
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2022 Resolved
Port main throat turning block at deck level found to be worn. Refurbish block to ensure pin is secure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2022
Resolved 13 July 2022
Resolution: SSD verified that the Port main throat turning block was secure.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2022 Resolved
Port main preventer bolt found to be wasted and oversized. Replace bolt with new, appropriately sized bolt.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2022
Resolved 13 July 2022
Resolution: SSD verified the port main preventer bolt was replaced with new and appropriately sized bolt
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022 Resolved
Engine room: dead-ended cable; remove.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2022
Resolved 13 July 2022
Resolution: SSD verified dead ended cable was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022 Resolved
Engine room electrical junction box cover missing hardware & not sealed. Repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2022
Resolved 13 July 2022
Resolution: SSD verified engine room electrical junction box cover was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 June 2022 Resolved
Main deck firepump starting battery terminal cable not properly sealed. Repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2022
Resolved 13 July 2022
Resolution: SSD verified proper battery terminal installation
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022 Resolved
Aft compartment electrical outlet cover broken. Repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2022
Resolved 13 July 2022
Resolution: SSD verified electrical outlet cover was replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022 Resolved
Aft compartment electrical dead ended cable; remove.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2022
Resolved 13 July 2022
Resolution: SSD verified dead ended cables removed in the aft compartment
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2022 Resolved
The owner / operator must make the vessel available for all specific inspections and drills the OCMI requires. Vessel is required to satisfactory demonstrate a fire and man overboard drill prior to the vessel carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 July 2022
Resolution: Vessel completed satisfactory drills in the presense of SSD MI's
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 13 June 2022 Resolved
Placards containing instructions for the donning and use of the types of life jackets carried aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2022
Resolved 13 July 2022
Resolution: SSD witness proper instuctions for donning and the use of lifejackets onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2022 Resolved
Engine room bilge bonding system; bonding wire corroded and not properly connected. Repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 June 2022
Resolution: Replaced main bonding plate and associated wiring.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 17 May 2022 Resolved
MDE and generator unit missing rotating belt guards. Install belt guards.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 22 June 2022
Resolution: Installed metal belt guards on Genset and main propulsion engine.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2022 Resolved
Forward compartment portable fire extinguisher at aft bulkhead; mounting bracket securing straps corroded. Repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 June 2022
Resolution: Bracket replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 July 2020 Resolved
Prove proper operation of inflatable rescue boat. Soap test required in presence of Marine Inspector. Alternate rescue boat obtained, tested and installed with proper equipment. Vessel restricted to LBS route (705c).
Action required: 705 - Other - as specified
Due 15 July 2020
Resolved 16 July 2021
Resolution: MI visually inspected rectified def.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 July 2020 Resolved
Complete servicing and properly install 03 life-rafts.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2020
Resolved 12 August 2020
Resolution: Liferafts on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 July 2020 Resolved
Properly repair bilge piping in Compartment B where PVC piping was installed.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2020
Resolved 14 August 2020
Resolution: Pictures received.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 July 2020 Resolved
Prove fire pump pressure at outlet (60psi).
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2020
Resolved 28 May 2021
Resolution: MI's verifed newly installed gasoline fire pump to provide >60psi at pump outlet off 01 hose.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 July 2020 Resolved
Install or prove proper operation of AIS (Class A or B).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 8 October 2020
Resolution: Verified on Marine Traffic.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 July 2020 Resolved
Properly input GPS location and MMSI into VHF-DSC radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 12 August 2020
Resolution: MMSI and GPS inputed. FCC technician ordered when AIS is installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 July 2020 Resolved
Ensure aft deck rails port/stbd are structurally sound in the opinion of the Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 14 August 2020
Resolution: Pictures received.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 15 July 2020 Resolved
Prove proper operation of fixed PA system operable from operating station which is audible during normal operations in each accomodation/crew space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 12 August 2020
Resolution: Speakers inside accom tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2020 Resolved
Double hose clamp all vital systems with flexible hoses in engine room (fuel/cooling/exhaust/shaft packing).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 12 August 2020
Resolution: Clamps found SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2020 Resolved
Properly mount MDE and GEN sea strainers and GEN Raycor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 12 August 2020
Resolution: Mounted properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 15 July 2020 Resolved
Vents to shower and head B shall be sealed off watertight or properly vented with gooseneck >12".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 28 July 2020
Resolution: Deck properly sealed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2020 Resolved
Mark vessel name on port side bow.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 8 October 2020
Resolution: Picture received.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2020 Resolved
Provide copy of annual rigging inspection report.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 28 July 2020
Resolution: Annual rigging inspection completed by Operator.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2020 Resolved
Maintain copy of approved vessel sail plan on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 28 July 2020
Resolution: Sail plan identified in MSC examined Stability Report referenced in MSC letter.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2020 Resolved
Plug forward pinhole on stbd side aft pin-rail due to wood rot IWO this section. Repair fully by next dry-dock.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 28 July 2020
Resolution: 02 forward pinholes plugged.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2020 Resolved
Provide list of crew qualified/trained as gunners.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 28 July 2020
Resolution: List of qualified/trained crew provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2020 Resolved
Provide retro reflective tape on deteriorated side of stbd life ring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 28 July 2020
Resolution: Proper retro reflective tape provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 March 2020 Resolved
Repair port side hawse pipe at next drydock. Due 09Mar2022.
Action required: 705 - Other - as specified
Due 22 March 2022
Resolved 14 June 2022
Resolution: Port Hawser pipe replaced in kind during 2022 Dry dock period.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 October 2019 Resolved
Replace smoke detector in forward-most berthing area.
Action required: 10 - Deficiency Rectified
Resolved 7 October 2019
Resolution: Corrected on the spot with a new smoke detector.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 October 2019 Resolved
Replace the faulty emergency lighting in the two forward-most berthing areas. To be completed prior to carrying passengers on overnight voyages.
Action required: 705 - Other - as specified
Resolved 16 October 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 October 2019 Resolved
Repair or remove the old emergency lighting system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2019
Resolved 16 October 2019
Resolution: Existing E-lighting was repaired and is opperational.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 October 2019 Resolved
Ensure that emergency lights automatically activate at a loss of power. To be corrected within 60 days.
Action required: 705 - Other - as specified
Due 6 December 2019
Resolved 16 October 2019
Resolution: Existing E-lighting system operates on loss of power.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 7 October 2019 Resolved
Label "Emergency Exit Keep Clear" on top and bottom side of all emergency exits.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2019
Resolved 16 October 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019 Resolved
Replace the missing interior bolt nuts on the forward chain plates on port and starboard. To be completed prior to using sails.
Action required: 705 - Other - as specified
Resolved 11 July 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019 Resolved
Replace the missing bolts on the forward-most chain plate. To be completed prior to using sails.
Action required: 705 - Other - as specified
Resolved 21 August 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019 Resolved
Repair/replace the second-most aft chain plate on the port side. To be completd prior to using sails.
Action required: 705 - Other - as specified
Resolved 11 July 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019 Resolved
Replace the missing hawse at approximately midship-port.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 11 July 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019 Resolved
Replace the missing hawse at approximately stern starboard side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 21 August 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019 Resolved
Repair the mainmast sail.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 11 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2019 Resolved
Replace Romex cable with boat cable on forward starboard shroud (white aft, black forward).
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 11 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2019 Resolved
Replace section of Romex cable with boat cable in forward/starboard bunk room.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 11 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2019 Resolved
Replace generator fuel hose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 21 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2019 Resolved
Repair generator water leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 11 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2019 Resolved
Replace generator air intake.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 21 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 27 June 2019 Resolved
Provide oven with proper propane hose with correct crimped/threaded fittings.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 11 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 June 2019 Resolved
Replace main engine fuel lines and support brackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 21 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 June 2019 Resolved
Prove operation of engine start batteries without generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 11 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 27 June 2018 Resolved
Provide new battery for EPIRB. Route restricted to Lakes, Bays, and Sounds.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 12 July 2018
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 June 2018 Resolved
Make captain's quarters bilge high water alarm function.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 12 July 2018
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 27 June 2018 Resolved
Make galley water tight door audible alarm operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 12 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 June 2018 Resolved
Provide retro reflective tape on life rings and repair identified holes.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 12 July 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2018 Resolved
Remove battery cables from bilge and provide supports every 24 inches.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2018
Resolved 12 July 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2018 Resolved
Provide cotter pins for both sides of all turnbuckles.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2018
Resolved 12 July 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2018 Resolved
Provide preventitive maintenance plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2018
Resolved 27 July 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 August 2017 Resolved
Haul out vessel for Dry Dock and Internal Structural Exam by Coast Guard Marine Inspector. Provide rigging survey by third party surveyor and unstep mast for inspection by Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2018
Fire Fighting › Fire Pumps › Pressure
Issued 27 March 2017 Resolved
Replace pressure gauge on fire pump.
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 31 May 2017
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 27 March 2017 Resolved
Provide B-15 shielding around galley stove prior to operation of stove.
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 31 March 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 March 2017 Resolved
Replace wasted waterlight line on port ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 31 March 2017
Personnel › Certificates/Documents/Licenses › License, Master
Issued 27 March 2017 Resolved
Provide licensed master's credentials prior to 01APR17.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2017
Fire Fighting › Fire Pumps › Pressure
Issued 21 March 2017 Resolved
Provide proof that fire pump maintains 60 PSI of pressure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 March 2017 Resolved
Repair faulty bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2017
Sail Rigging › Chainplates › Materials
Issued 21 March 2017 Resolved
Provide final report of 3rd party sail rigging survey.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2017
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 31 May 2016 Resolved
Renew lower deck support beam in forward compartment
Condition: Improper Installation
Due 15 June 2016
Resolved 22 June 2016
Resolution: The deck beam was properly re-inforced
Engineering › Fuel Oil Service System › Filter
Issued 31 May 2016 Resolved
Install flame shield and metal plug on generator prime mover secondary fuel filter.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 22 June 2016
Resolution: Flame shield properly installed
Fire Fighting › Fire Pumps › Pressure
Issued 31 May 2016 Resolved
Prove proper operation of the fire pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 22 June 2016
Engineering › Freshwater System (cylinder head cooling) › Sensor
Issued 31 May 2016 Resolved
Prove proper operation of the main engine jacket water gauge located at the operating station.
Condition: Improper/Lack of Maintenance
Due 15 June 2016
Resolved 22 June 2016
Resolution: Gauge was replaced and tested.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 31 May 2016 Resolved
Renew main engine sea strainer.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 22 June 2016
Resolution: Sea stariner was replaced.
Documentation › Certificates/Documents › Stability Letter
Issued 29 May 2012 Resolved
Obtain a Stability Letter Addendum from Marine Safety Center and until it is received the total number of person allowed is reduced down to 76.
Action required: 705 - Other - as specified
Due 29 August 2012
Resolved 5 September 2013
Resolution: New stability letter issued by MSC.
Documentation › Logs/Records › Drug Test Records
Issued 29 May 2012 Resolved
Complete DAPI audit - provide yearend report and proof of MIS fwd to COMDT by 15MAR.
Due 15 June 2012
Resolved 15 June 2012
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 29 May 2012 Resolved
Replace M/E raw water coolant hoses.
Due 15 June 2012
Resolved 15 June 2012
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 May 2012 Resolved
Label E- lighting station with red E.
Due 15 June 2012
Resolved 15 June 2012
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 29 May 2012 Resolved
Clean grease IWO galley stove.
Due 15 June 2012
Resolved 15 June 2012
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 29 May 2012 Resolved
Repair galley stove hand rail.
Due 15 June 2012
Resolved 15 June 2012
Electrical › Electric Supply System (service) › Cable
Issued 27 September 2011 Resolved
Replace all Welding cable with approved Marine Grade Cable.
Action required: 705 - Other - as specified
Due 27 October 2011
Resolved 14 October 2011
Resolution: Replaced all Welding cable with approved Marine Grade Cable.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 27 September 2011 Resolved
Make aft engineroom overhead vapor tight
Action required: 705 - Other - as specified
Due 27 October 2011
Resolved 14 October 2011
Resolution: Made aft engineroom overhead vapor tight
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 April 2009 Resolved
Make vessel available for hull exam in accordance with 46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2009
Resolved 19 May 2009
Resolution: Credit for hull exam given this date.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 1 April 2009 Resolved
Hydrostatic release expired.
Action required: 705 - Other - as specified
Due 1 April 2009
Resolved 1 April 2009
Resolution: renewed in kind
Engineering › Lubricating Oil Service System › Gauge
Issued 1 April 2009 Resolved
Repair MDE L/O PSI gauge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2009
Resolved 1 April 2009
Resolution: Vessel engineer corrected/ on the spot
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 13 November 2008 Resolved
Provide adequate means of structural fire protection for wooden barrier on the right side of LPG stove in galley IAW 46CFR177.410(a). Vessel prohibited from using stove until rectified.
Action required: 705 - Other - as specified
Due 13 December 2008
Resolved 8 April 2009
Resolution: Structural fire protection installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 November 2008 Resolved
Provide cover for exposed fixed light in "B" compartment accommodation space IAW 46CFR183.200(b).
Action required: 705 - Other - as specified
Due 13 December 2008
Resolved 8 April 2009
Resolution: Cover for light installed.
Documentation › Certificates/Documents › FCC SSL
Issued 3 November 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 13 December 2008
Resolved 3 November 2008
Resolution: Vessel obtained new Station License w/ expiration 11/2018.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 3 November 2008 Resolved
Repair/renew revolution per minute (RPM) gauge for main engine at local gauging station as per 46CFR182.410 (b).
Action required: 705 - Other - as specified
Due 13 December 2008
Resolved 8 April 2009
Resolution: RPM gauge repaired.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 4 June 2007 Resolved
Repair leak in the sewage holding tank in the Alpha compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 July 2007
Resolved 15 June 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 June 2007 Resolved
Remove/cap dead end wires throughout the vessel.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 15 June 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 June 2007 Resolved
Make DC terminal block in the engine room dripproof IAW 46 CFR 183.210.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 15 June 2007
Deck/Cargo › Holds/Tanks › Hatch
Issued 4 June 2007 Resolved
Provide securing devices for all hatches on the main deck IAW 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 15 June 2007
Engineering › Bilge Water Management System › Hose
Issued 4 June 2007 Resolved
Renew deterioated hose for the MDE driven bilge pump.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 15 June 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 February 2007 Resolved
[name withheld] notified owner on 14 FEB 2007 that the vessel was overdue for a hull inspection. Wrote a CG-835, no sail to vessel until a hull examination was completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2007
Resolved 29 March 2007
Resolution: Credit for dry dock given this date.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 February 2007 Resolved
From hull examination work list item # 01, dated 21FEB07, repair wood rot and cracking on bulwark under deck railing throughout vessel to provide safety of passengers and crew IAW 46 CFR 177.900.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2007
Resolved 4 June 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 20 February 2007 Resolved
Repair wood where bolt penetration on port bow frame.
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 4 June 2007
Construction/Loadline › Structures › Superstructure
Issued 20 February 2007 Resolved
Repair billet head rotted wood area.
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 4 June 2007
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 24 January 2005 Resolved
Renew 30X30 mesh flame screen on fuel tank vent pipe.
Action required: 703 - Prior to bunkering operations
Due 24 February 2005
Resolved 24 January 2005
Resolution: Renewed 30X30 mesh flame screen on fuel tank vent pipe.
Engineering › Pressure Vessel › Marking and Stamping
Issued 24 January 2005 Resolved
Remove or replace existing air receiver with ASME approved pressure vessel to U or UM designation IAW CFR 182.330.
Action required: 705 - Other - as specified
Due 24 February 2005
Resolved 17 February 2005
Resolution: Removed air receiver.
Electrical › Electric Generation Source (service) › Generator
Issued 24 January 2005 Resolved
Renew ammeter on Lister generator IAW 183.320(c).
Action required: 705 - Other - as specified
Due 24 February 2005
Resolved 17 February 2005
Resolution: Renewed ammeter on Lister generator.
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 23 October 2003 Resolved
Missing "Emergency Escape Keep Clear" sign posted at escape hatch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2003
Resolved 30 October 2003
Resolution: Sign posted for escape hatch as required.
Construction/Loadline
Issued 23 October 2003 Resolved
Wood rot noticed on interior of vessel around all glass view prisms on deck. Required operator to treat all rotted areas.
Condition: Design Flaw
Due 31 October 2003
Resolved 30 October 2003
Resolution: Wood rot treated as required.
Lifesaving › Inflatable Liferafts
Issued 10 October 2002 Resolved
IBA not serviced within last 12 months.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 9 May 2003
Construction/Loadline › Structures
Issued 10 October 2002 Resolved
Replace broken glass in skylight leading into galley.
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 9 May 2003
Construction/Loadline › Structures
Issued 10 October 2002 Resolved
Make forward hatch weathertight. LEGACY COMPONENT DESC: Door
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 9 May 2003
Operations/Management › Drug and Alcohol Testing
Issued 10 October 2002 Resolved
EAP not in accorance with 46 CFR 16.401. LEGACY COMPONENT DESC: EAP Training Requirements
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 9 May 2003
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 10 October 2002 Resolved
Copy of MIS not retained.
Due 10 October 2002
Resolved 10 October 2002
Construction/Loadline
Issued 18 October 1999 Resolved
In fore peak berthing area make hole in way of aft bulkhead, port side, upper that passes bilge alarm wiring water tight.
Condition: Unknown
Due 29 October 1999
Resolved 3 November 1999
Documentation
Issued 18 October 1999 Resolved
Provide proff of 60 minute of supervisory E.A.P. training per 46/16.401.
Condition: Unknown
Due 18 November 1999
Resolved 3 November 1999
Documentation
Issued 18 October 1999 Resolved
Provide proof of available 24 HR collection facility or 6 urine sampling kits onboard vessel, per 46/16.240.
Condition: Unknown
Due 18 November 1999
Resolved 3 November 1999
Documentation
Issued 18 October 1999 Resolved
Missing Station Bill.
Condition: Unknown
Due 29 October 1999
Resolved 3 November 1999
Electrical
Issued 18 October 1999 Resolved
Missing cover for electrical panel on back of control at steering station.
Condition: Unknown
Due 29 October 1999
Resolved 3 November 1999
Accommodation/Occupational Safety
Issued 18 October 1999 Resolved
Provide Holding tank/MSD for or remove toilet in captain's cabin - over board discharge to remain locked and toilet not in use until corrected.
Condition: Unknown
Due 29 October 1999
Resolved 3 November 1999
Documentation
Issued 18 October 1999 Resolved
Complete and submit M.I.S. per 46/16.500.
Condition: Unknown
Due 18 November 1999
Resolved 3 November 1999
Lifesaving
Issued 6 February 1999 Resolved
SERVICE LIFERAFTS.
Condition: Unknown
Due 13 February 1999
Resolved 26 February 1999
Lifesaving
Issued 6 February 1999 Resolved
PROVIDE LIGHTS ON ALL LIFEJACKETS.
Condition: Unknown
Due 13 February 1999
Resolved 26 February 1999
Lifesaving
Issued 6 February 1999 Resolved
REPAINT VESSEL NAME ON LIFE BUOYS.
Condition: Unknown
Due 13 February 1999
Resolved 26 February 1999
Navigation
Issued 6 February 1999 Resolved
PROVIDE CURRENT TIDE TABLES.
Condition: Unknown
Due 13 February 1999
Resolved 26 February 1999
Fire Fighting
Issued 6 February 1999 Resolved
SERVICE FIRE EXTINGUISHERS.
Condition: Unknown
Due 13 February 1999
Resolved 26 February 1999
Navigation
Issued 6 February 1999 Resolved
PROVIDE CURRENTLY CORRECT CHARTS, COAST PILOT AND LIGHT LIST.
Condition: Unknown
Due 13 February 1999
Resolved 26 February 1999
Documentation
Issued 6 February 1999 Resolved
PROVIDE PROOF OF SATISFACTORY DRUG PROGRAM.
Condition: Unknown
Due 13 February 1999
Resolved 26 February 1999
Lifesaving
Issued 6 February 1999 Resolved
PROVIDE "EPIRB" TEST LOG.
Condition: Unknown
Due 13 February 1999
Resolved 26 February 1999
Lifesaving
Issued 6 February 1999 Resolved
PROVIDE (6) NEW RED HAND FLARES.
Condition: Unknown
Due 13 February 1999
Resolved 26 February 1999
Lifesaving
Issued 6 February 1999 Resolved
RENEW RETROFLECTIVE TAPE ON APPROX (10) LIFEJACKETS.
Condition: Unknown
Due 13 February 1999
Resolved 26 February 1999
Navigation
Issued 28 October 1996 Resolved
PROVIDE UL APPROVED NAVIGATION LIGHTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Engineering
Issued 28 October 1996 Resolved
PROPERLY INSTALL INSULATION ON THE STBD ENGINE EXHAUST, JUST AFT OF THE MANIFOLD.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Lifesaving
Issued 28 October 1996 Resolved
POST LIFEJACKET PLACARD FOR TYPE OF LIFEJACKETS ABOARD.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Electrical
Issued 13 October 1995 Resolved
UPON INSPECTION OF ELECTRICAL PANEL, POSSIBLE DECK WEEPAGE NOTED. CG-835 ISSUED TO ALTER REPLACE PANEL AND REPAIR DECK PRIOR TO 31 OCT 96 TO MEET COAST GUARD REQUIREMENTS.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Navigation
Issued 13 October 1995 Resolved
CURRENT WHEEL BOX DESIGN DOES NOT ALLOW FOR TILLER ARM ATTACHMENT. COULD NOT TEST EMERGENCY STEERING. IN EVENT OF STEERING CASUALTY, BACK WALL OF BOX WOULD HAVE TO BE KNOCKED OUT TO ATTACH TILLER ARM. CG-835 ISSUED TO MODIFY WHEEL BOX PRIOR TO 31 OCT 96 TO ALLOW FOR ATTACHMENT.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Navigation
Issued 13 October 1995 Resolved
VESSEL DID NOT HAVE CURRENT AREA CHARTS, LIGHT LIST AND COAST PILOT.
Condition: Unknown
Due 16 October 1995
Resolved 14 February 1996
Electrical
Issued 13 October 1994 Resolved
REPAIR/REPLACE ELECTRICAL JUNCTION BOX LOCATED IN FORWARD ACCOMMODATION SPACE, STARBOARD SIDE.
Condition: Unknown
Due 20 October 1994
Resolved 30 November 1994
Documentation
Issued 13 October 1994 Resolved
PROVIDE INFORMATION REGARDING CHEMICAL TESTING IN ACCORDANCE WITH 46 CODE OF FEDERAL REGULATIONS PART 16.
Condition: Unknown
Due 13 November 1994
Resolved 30 November 1994
Lifesaving
Issued 6 October 1993 Resolved
CONDUCT UNDERWAY LIFE SAVING DRILL IN THE PRESENCE OF CG MARINE INSPECTOR.
Condition: Unknown
Due 6 October 1993
Resolved 6 October 1993
Electrical
Issued 13 October 1992 Resolved
Provide and install rear housing assembly for Lister engine generator on deck.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Engineering
Issued 13 October 1992 Resolved
Demonstrate proper operation of Tachometer for main propulsion engine.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Electrical
Issued 13 October 1992 Resolved
Make proper repair to oil pressure guage on Lister deck engine.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Documentation
Issued 15 October 1991 Resolved
Provide fcc operators permit.
Condition: Unknown
Due 15 October 1991
Resolved 15 October 1991
Navigation
Issued 15 October 1991 Resolved
Demonstrate proper operation of starboard running light.
Condition: Unknown
Due 1 November 1991
Resolved 1 November 1991
Navigation
Issued 15 October 1991 Resolved
Provide current charts and light list for area.
Condition: Unknown
Due 1 November 1991
Resolved 1 November 1991
Navigation
Issued 15 October 1991 Resolved
Demonstrate operation of emergency steering._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 November 1991
Resolved 1 November 1991
Lifesaving
Issued 15 October 1991 Resolved
Provide 01 adult PFD.
Condition: Unknown
Due 1 November 1991
Resolved 1 November 1991
Lifesaving
Issued 1 July 1991 Resolved
PROVIDE ONE CHILD PFD. NUMBER OF CHILDREN PERMITTED TO BE CARRIED IS FIVE
Condition: Unknown
Due 1 July 1991
Resolved 1 July 1991
Engineering
Issued 1 July 1991 Resolved
PROVIDE FUEL FILTER HEAT SHIELD FOR RACOR FUEL FILTER
Condition: Unknown
Due 1 July 1991
Resolved 1 July 1991
Engineering
Issued 1 July 1991 Resolved
INSTALL 30X30 MESH FLAME SCREEN IN PORT FUEL TANK VENT
Condition: Unknown
Due 1 July 1991
Resolved 1 July 1991
Construction/Loadline
Issued 1 July 1991 Resolved
RECALK TRANSOM. ROUTE RESTRICTED TO LBS UNTIL COMPLETED.
Condition: Unknown
Due 1 July 1991
Resolved 1 July 1991
Fire Fighting
Issued 1 July 1991 Resolved
INSTALL REMOTE RELEASE DEVICE FOR INSTALLED FIXED HALON PRIOR TO 1AUG91
Condition: Unknown
Due 1 July 1991
Resolved 1 July 1991
Construction/Loadline
Issued 31 October 1990 Resolved
B. INSTALL ON INDICATOR LIGHT FOR EACH DOOR AT THE OPERATORS STATION WHICH WARNS WHEN THE DOOR IS OPEN
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Documentation
Issued 31 October 1990 Resolved
PROVIDE FCC OPERATORS LICENSE
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
DEMONSTRATE 12VDC EMERGENCY LIGHTING
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Lifesaving
Issued 31 October 1990 Resolved
PROVIDE SIX ORANGE FLARES
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Lifesaving
Issued 31 October 1990 Resolved
PROVIDE 4 ADULT AND 2 CHILD'S PFD'S
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Fire Fighting
Issued 31 October 1990 Resolved
INSTALLED FIXED HALON SYSTEM MUST SHUT DOWN DIESEL ENGINE UPON ACTIVIATION AND PRIOR TO RELEASE OF AGENT
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Fire Fighting
Issued 31 October 1990 Resolved
INSTALLED FIXED HALON SYSTEM MUST SHUT DOWN VENTILATION SYSTEM UPON ACTIVATION AND PRIOR TO RELEASE OF AGENT
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Construction/Loadline
Issued 31 October 1990 Resolved
FOR THE TWO WATERTIGHT DOORS BETWEEN MAIN SALON AND "B" COMPARTMENT AND "B"COMPARTMENT AND "A" COMPARTMENT: A. MARK ON BOTH SIDES IN AT LEAST ONE INCH LETTERS: "WATERTIGHT DOOR - KEEP CLOSED AT ALL TIMES WHEN TRANSITING"
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Fire Fighting
Issued 31 October 1990 Resolved
INSTALLED FIXED HALON SYSTEM MUST BE ABLE TO BE MANUALLY ACRTIVATED WITH A REMOTE RELEASE DEVICE
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
BLOCK LISTER BATTERY COMPARTMENT
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
CORRECTLY WIRE FIRE PUMP/BATTERY CHARGER
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Lifesaving
Issued 31 October 1990 Resolved
MARK ON DECK OFD STOWAGE AND CHILD'S PFD STOWAGE
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Engineering
Issued 31 October 1990 Resolved
CONDUCT UNDERWAY TEST IN PRESENCE OF CG MARINE INSPECTOR
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Navigation
Issued 31 October 1990 Resolved
DEMONSTRATE ALL ELECTRONICS
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Fire Fighting
Issued 31 October 1990 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUIHERS
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Engineering
Issued 31 October 1990 Resolved
REPAIR "A" COMPARTMENT EDISON HAND BILGE PUMP
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Navigation
Issued 31 October 1990 Resolved
DEMONSTRATE ALL NAVIGATION LIGHTS
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Unknown
Issued 15 November 1989 Resolved
SERVICE LIFERAFTS BY 1JAN90
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Unknown
Issued 15 November 1989 Resolved
ADJUST STARBOARD RUNNING LIGHT SOCKET SO AS TO PLACE BULB IN CENTER OF LENS
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Unknown
Issued 15 November 1989 Resolved
PROVIDE ONE ADDITIONAL B-II SIZE FIRE EXTINGUISHER ON VESSEL
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Unknown
Issued 15 November 1989 Resolved
PROVIDE TWO ADDITIONAL ADULT PFD'S ON BOARD VESSEL
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Unknown
Issued 15 November 1989 Resolved
RENEW FCC SAFETY CERTIFICATE
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Unknown
Issued 15 November 1989 Resolved
PROVIDE ONE NEW LIFERING (24" DIAM) ON BOARD VESSEL
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Unknown
Issued 15 November 1989 Resolved
PREPACK VALVE STEM ON FIRE STATION PORT
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Fire Fighting
Issued 5 January 1989 Resolved
SUBMIT WRITTEN PROPOSAL FOR REPLACING PVC PIPE IN FIREMAIN WITH METALLIC PIPE AND FOR CROSS-CONNECTING TWO FIRE HYDRANTS, OR PROVIDE CERTIFICATION THAT EXISTING INSTALLATION HAS BEEN APPROVED. WRITTEN PROPOSAL SHOULD INCLUDE TIMETABLE, SKETCH OF SYSTEM, MATERIALS USED, AND LOCATION OF REPAIR
Condition: Unknown
Due 5 January 1989
Resolved 5 January 1989
Fire Fighting
Issued 5 January 1989 Resolved
INSTALL PRESSURE GUAGE AT DISCHARGE END OF 60 PSI, 50 GPM, FIXED, POWER, FIRE PUMP.
Condition: Unknown
Due 5 January 1989
Resolved 5 January 1989
Fire Fighting
Issued 5 January 1989 Resolved
EFFECT ALTERATIONS TO FIRE MAIN SYSTEM IN ACCORDANCE WITH APPROVED PLANS SUBMITTED 20JAN89 AND [name withheld] LETTER 16711/D533074 DATED 01FEB89.
Condition: Unknown
Due 5 January 1989
Resolved 5 January 1989
Lifesaving
Issued 5 January 1989 Resolved
PROVIDE ONE ADDITIONAL ADULT LIFE PRESERVER.
Condition: Unknown
Due 5 January 1989
Resolved 5 January 1989
Fire Fighting
Issued 5 January 1989 Resolved
PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER OR EQUIVALENT FIXED FIRE- FIGHTING SYSTEM IN ENGINEROOM.
Condition: Unknown
Due 5 January 1989
Resolved 5 January 1989
Fire Fighting
Issued 19 July 1988 Resolved
RENEW #2 FIRE MAIN COUPLING LOCATED JUST INBOARD OF THROUGH HULL FITTING.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Construction/Loadline
Issued 19 July 1988 Resolved
RENEW PLANKING AS FOLLOWS: A. STARBOARD PLANK #14 BETWEEN FRAMES #34 AND #52. B. PORT PLANK #20 BETWEEN FRAMES #46 AND #59
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Construction/Loadline
Issued 2 February 1988 Resolved
PLANKS TO BE RENEWED ON STBD SIDE AS FOLLOWS: PLANK 23 STEM TO FRAME 3,PLANK 22 STEM TO FRAME 5,PLANK 21 STEM TO FRAME 7 PLANK 20 STEM TO FRAME 5,PLANK 19 STEM TO FRAME 3,PLANK 18 STEM TO FRAME 5 PLANK 17 STEM TO FRAME 8,PLANK 16 STEM TO FRAME 3,PLANK 15 STEM TO FRAME 11
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Construction/Loadline
Issued 2 February 1988 Resolved
PLANKS TO BE RENEWED ON STBD SIDE AS FOLLOWS: PLANK 14 STEM TO FRAME 5,PLANK 13 STEM TO FRAME 9,PLANK 12 STEM TO FRAME 14PLANK 11 STEM TO FRAME 11.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Construction/Loadline
Issued 2 February 1988 Resolved
PLANKS TO BE RENEWED ON PORT SIDE AS FOLLOWS: PLANK 23 STEM TO FRAME 4 PLANK 22 STEM TO FRAME 7,PLANK 21 STEM TO FRAME 9,PLANK 20 STEM TO FRAME 7 PLANK 19 STEM TO FRAME 5,PLANK 18 STEM TO FRAME 11,PLANK 17 STEM TO FRAME 9PLANK 16 STEM TO FRAME 7,PLANK 15 STEM TO FRAME 5,PLANK 14 STEM TO FRAME 3
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Construction/Loadline
Issued 2 February 1988 Resolved
PLANKS TO BE RENEWED ON PORT SIDE AS FOLLOWS: PLANK 15 FRAME 31 TO 47, PLANK 14 FRAME 34 TO 40, PLANK 13 FRAME 36 TO 45 PLANK 12 FRAME 35 TO 42, PLANK 11 FRAME 32 TO 40, PLANK 10 FRAME 31 TO 43 PLANK 9 FRAME 35 TO 46, PLANK 8 FRAME 33 TO 42, PLANK 7 FRAME 32 TO 44
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Construction/Loadline
Issued 2 February 1988 Resolved
PLANKS TO BE RENEWED ON PORT SIDE AS FOLLOWS: PLANK 6 FRAME 30 TO 51, PLANK 5 FRAME 38 TO 44.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Construction/Loadline
Issued 2 February 1988 Resolved
FRAMES TO BE RENEWED AS FOLLOWS: PORT SIDE COMPLETE #1 FRAME, TOP TIMBER OF #2 FRAME, FUTTOCKS OF #37, #38, #39 AND #40. STARBOARD SIDE COMPLETE #1 FRAME.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Engineering
Issued 2 February 1988 Resolved
RENEW THE FOREMAST.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Construction/Loadline
Issued 2 February 1988 Resolved
RENEW THE CEILING, BILGE CLAMP, SHELF AND DECKING AT BOW, SCARFING STENGTH MEMBERS INTO GOOD WOOD AS APPROPRIATE. ALSO RENEW THE CEILING IN WAY OF FRAME #37 THRU #40, AGAIN SCARFING NEW MEMBERS INTO GOOD WOOD AS APPROPRIATE.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Construction/Loadline
Issued 3 June 1985 Resolved
RENEW/REPAIR TWO (2) MUSHROOM VENTS AT FOREPEAK.
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985

Casualty record · 2

14 April 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2523315
8 September 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 4441145
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.