BILL OF RIGHTS
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named BILL OF RIGHTS
BILL OF RIGHTS is a 1971 passenger vessel (inspected). The Coast Guard has recorded 98 inspections since 1985, most recently in June 2025, along with 202 deficiencies, 1 operational control and 2 casualty investigations between 2005 and 2012.
Records from 1985 to 2025. Most recent: inspection, 24 June 2025.
- Built
- 1971
- Last inspected
- 24 June 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 202 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2005–2012
Identity
533074
WDH2461
46912
Flag
UNITED STATES
338151000
Maury page id
psix-46912
Inspections, by type
…with no type recorded11
Years with a record
38 calendar years (1985–2025)
The 98 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)89.6 ft × 23.8 ft × 9.6 ft
Registered tonnagegross 95 / net 87
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHARVEY F GAMAGE SHIPBUILDER INC · SOUTH BRISTOL, ME, UNITED STATES · built 1971
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHULA VISTA, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 August 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
87 - Regulatory (Subpart C or D), Net Ton
87 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDP7675MMSI 338151000 · active · compulsorily equipped · granted 17 August 2024, expires 17 August 2034
WDH2461MMSI 338151000 · expired · compulsorily equipped · granted 7 December 2013, cancelled 10 February 2024
WDE6817MMSI 367385250 · expired · compulsorily equipped · granted 19 November 2008, cancelled 16 February 2019
WCX8898MMSI not assigned · expired · compulsorily equipped · granted 22 December 1997, cancelled 19 April 2008
WTF3528MMSI not assigned · expired · compulsorily equipped · granted 6 October 1997, cancelled 9 February 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 98
24 June 2025
Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8166595
5 September 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7996473
6 August 2024
Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7975357
24 June 2024
Internal Structural Exam · Drydock Extension
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7941545
26 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7723830
26 June 2023
Deficiency Check · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7725985
26 June 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7774546
13 June 2022
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7491538
17 May 2022
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7452922
16 July 2021
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7261364
28 May 2021
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7209207
17 November 2020
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7097649
15 July 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7005142
9 March 2020
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6923461
7 October 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6830126
27 June 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6727308
27 June 2018
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6436352
18 April 2018
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6409530
14 August 2017
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6240813
21 March 2017
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6108712
31 May 2016
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5892476
28 July 2015
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5198657
30 May 2014
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4874627
29 May 2012
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4306214
27 September 2011
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4306193
8 April 2009
Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3444552
18 March 2009
Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3444140
3 November 2008
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3348290
15 June 2007
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2966172
30 May 2007
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2939511
20 February 2007
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2874527
27 January 2006
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2574670
27 June 2005
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2404514
2 June 2005
Attraction Vessel Exam · Excursion Permit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2377438
21 April 2005
Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 2340191
14 April 2005
Type not recorded
No type recorded · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2523315
21 March 2005
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2315956
24 January 2005
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2278206
7 January 2005
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2270788
16 November 2004
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2238680
31 October 2003
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1939650
23 October 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1932233
8 February 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1747187
30 October 2002
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1698399
2 October 2002
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1683306
19 November 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1075755
5 November 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1366645
4 April 2001
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1059850
17 October 2000
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1391394
18 October 1999
COI Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1440211
21 June 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1449193
11 March 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 805128
6 February 1999
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375635
29 January 1999
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 790259
11 January 1999
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1438763
11 September 1998
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 799151
24 May 1998
Inclining Experiment
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1127487
10 March 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 789113
18 December 1997
Re-Inspection · Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1375214
29 April 1997
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1094642
30 October 1996
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 13671
28 October 1996
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1356014
18 October 1996
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 855355
14 February 1996
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1188135
13 October 1995
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1448733
25 October 1994
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 868950
13 October 1994
MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1411048
29 July 1994
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 146856
6 October 1993
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1164479
14 April 1993
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1142946
13 October 1992
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1401642
3 June 1992
Excursion Permit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 947955
22 April 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 953304
19 December 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1265152
29 November 1991
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 942601
15 October 1991
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1407052
10 October 1991
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1247693
30 August 1991
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1251779
1 July 1991
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 937067
31 October 1990
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 919024
5 October 1990
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 930990
3 October 1990
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1242599
10 September 1990
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 905624
23 February 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 926259
22 January 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1240843
17 January 1990
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 920170
15 November 1989
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1223410
19 September 1989
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1197774
12 September 1989
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 895247
9 February 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1344767
5 January 1989
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1196012
15 November 1988
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 894127
19 July 1988
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 898688
9 March 1988
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1029673
2 February 1988
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1034923
24 July 1986
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1307232
10 June 1986
Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1310818
3 June 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1291583
Deficiency record · 202
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2025
Resolved
The design, materials, and construction of masts, posts,
yards, booms, bowsprits, and standing rigging on a
sailing vessel must be suitable for the intended
service. Vessels inner bob-stay, jib haul out, and
hardware in way of bowsprit bob-stay/whisker-stays were
found broken, damaged, or corroded during inspection.
Vessel is required to make all required repairs and
provide third party survey attesting to condition of all
rigging prior to hauling any sails or getting underway
with passengers on board.
Cite: 46 CFR 177.330.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 September 2024
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. MI found expired FCC Station license. Crew has already ordered an new one. Send new certificate to [email withheld] once received.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 September 2024
Resolved
Found a bulkhead penetration in the engine room that was not sealed and would allow the fixed firefighting to escape outside. Seal bulkheaded penetration with approved material and notify local OCMI when repairs are completed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 September 2024
Resolved
Each collision bulkhead must be maintained watertight. MI found collision bulkhead was not maintained watertight as plug was missing from a pipe. Put cap on pipe to make collision bulkhead watertight and notify local OCMI for inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 September 2024
Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Vessel is missing four adult life jackets at the port and STBD storage location, midship and two in the captain’s cabin. Vessel is to replace life jackets w/ approved whistle.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 September 2024
Resolved
Vessel pyrotechnic distress signals were all expired. Vessel is to replace all pyrotechnic distress signals (6 red and 6 orange) or 12 combination hand flare and smoke.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 September 2024
Resolved
Observed dead-end wires located FWD of the engine room (portside and by muffler). Vessel is to terminate wires in a terminal box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 September 2024
Resolved
Observed A-compartment bilge pump not operational. Vessel to repair pump prior to departure.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 September 2024
Resolved
Observed rotting wood on Mast mast step. Vessel is to have the mast step available for further inspection underneath the mast. Vessel is to provide a repair plan prior to repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 September 2024
Resolved
Vessel provide a repair plan to use a wire brush and vacuuming up rotten wood. Vessel can try this plan but is not aloud to have any passengers, no other persons onboard except necessary crew to facilitate repairs.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 June 2023
Resolved
All escape hatches and other means of escape must be marked on both sides "EMERGENCY EXIT, KEEP CLEAR". Vessel's emergency escapes are not marked on both sides. Install adequate signage for emergency escapes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 June 2023
Resolved
Vessel diesel generator found to have fuel filter installed incorrectly (upside down) Install filter with flame bowl on the bottom.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2023
Resolved
Fuel line from filter to engine found to have incorrect connection. Install J-1942 approved fuel line with J-1942 approved connections.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2023
Resolved
Distribution panel IWO engine room found to have wasted door. Replace hinge and make latch operable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2023
Resolved
Wiring IWO engine room found to not be securely mounted. Install wire supports no more than 12 inches apart.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2023
Resolved
Battery bank on deck found to be installed without a battery box or securing mounts. Provide a protective battery box and secure to prevent movement.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 June 2022
Resolved
Vessel found to have missed annual inspection window. Schedule COI inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 June 2022
Resolved
EPIRP hydrostatic release found to be expired. Vessel restricted to Lakes, Bays, Sounds until new hydrostatic release is installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2022
Resolved
Both ring buoys found to have wasted lanyards. Replace lanyards with approved material.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 June 2022
Resolved
STBD water light mount found to be loose. Install mount to prevent movement while underway.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2022
Resolved
Port main throat turning block at deck level found to be worn. Refurbish block to ensure pin is secure.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2022
Resolved
Port main preventer bolt found to be wasted and oversized. Replace bolt with new, appropriately sized bolt.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022
Resolved
Engine room: dead-ended cable; remove.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022
Resolved
Engine room electrical junction box cover missing hardware & not sealed. Repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 June 2022
Resolved
Main deck firepump starting battery terminal cable not properly sealed. Repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022
Resolved
Aft compartment electrical outlet cover broken. Repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022
Resolved
Aft compartment electrical dead ended cable; remove.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2022
Resolved
The owner / operator must make the vessel available for all specific inspections and drills the OCMI requires. Vessel is required to satisfactory demonstrate a fire and man overboard drill prior to the vessel carrying passengers for hire.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 13 June 2022
Resolved
Placards containing instructions for the donning and use of the types of life jackets carried aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2022
Resolved
Engine room bilge bonding system; bonding wire corroded and not properly connected. Repair.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 17 May 2022
Resolved
MDE and generator unit missing rotating belt guards. Install belt guards.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2022
Resolved
Forward compartment portable fire extinguisher at aft bulkhead; mounting bracket securing straps corroded. Repair/replace.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 July 2020
Resolved
Prove proper operation of inflatable rescue boat. Soap test required in presence of Marine Inspector. Alternate rescue boat obtained, tested and installed with proper equipment. Vessel restricted to LBS route (705c).
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 July 2020
Resolved
Complete servicing and properly install 03 life-rafts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 July 2020
Resolved
Properly repair bilge piping in Compartment B where PVC piping was installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 July 2020
Resolved
Prove fire pump pressure at outlet (60psi).
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 July 2020
Resolved
Install or prove proper operation of AIS (Class A or B).
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 July 2020
Resolved
Properly input GPS location and MMSI into VHF-DSC radio.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 July 2020
Resolved
Ensure aft deck rails port/stbd are structurally sound in the opinion of the Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 15 July 2020
Resolved
Prove proper operation of fixed PA system operable from operating station which is audible during normal operations in each accomodation/crew space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2020
Resolved
Double hose clamp all vital systems with flexible hoses in engine room (fuel/cooling/exhaust/shaft packing).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2020
Resolved
Properly mount MDE and GEN sea strainers and GEN Raycor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 15 July 2020
Resolved
Vents to shower and head B shall be sealed off watertight or properly vented with gooseneck >12".
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2020
Resolved
Mark vessel name on port side bow.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2020
Resolved
Provide copy of annual rigging inspection report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2020
Resolved
Maintain copy of approved vessel sail plan on board.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2020
Resolved
Plug forward pinhole on stbd side aft pin-rail due to wood rot IWO this section. Repair fully by next dry-dock.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2020
Resolved
Provide list of crew qualified/trained as gunners.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2020
Resolved
Provide retro reflective tape on deteriorated side of stbd life ring.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 March 2020
Resolved
Repair port side hawse pipe at next drydock. Due 09Mar2022.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 October 2019
Resolved
Replace smoke detector in forward-most berthing area.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 October 2019
Resolved
Replace the faulty emergency lighting in the two forward-most berthing areas. To be completed prior to carrying passengers on overnight voyages.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 October 2019
Resolved
Repair or remove the old emergency lighting system.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 October 2019
Resolved
Ensure that emergency lights automatically activate at a loss of power. To be corrected within 60 days.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 7 October 2019
Resolved
Label "Emergency Exit Keep Clear" on top and bottom side of all emergency exits.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019
Resolved
Replace the missing interior bolt nuts on the forward chain plates on port and starboard. To be completed prior to using sails.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019
Resolved
Replace the missing bolts on the forward-most chain plate. To be completed prior to using sails.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019
Resolved
Repair/replace the second-most aft chain plate on the port side. To be completd prior to using sails.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019
Resolved
Replace the missing hawse at approximately midship-port.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019
Resolved
Replace the missing hawse at approximately stern starboard side.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2019
Resolved
Repair the mainmast sail.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2019
Resolved
Replace Romex cable with boat cable on forward starboard shroud (white aft, black forward).
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2019
Resolved
Replace section of Romex cable with boat cable in forward/starboard bunk room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2019
Resolved
Replace generator fuel hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2019
Resolved
Repair generator water leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2019
Resolved
Replace generator air intake.
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 27 June 2019
Resolved
Provide oven with proper propane hose with correct crimped/threaded fittings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 June 2019
Resolved
Replace main engine fuel lines and support brackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 June 2019
Resolved
Prove operation of engine start batteries without generator.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 27 June 2018
Resolved
Provide new battery for EPIRB. Route restricted to Lakes, Bays, and Sounds.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 June 2018
Resolved
Make captain's quarters bilge high water alarm function.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 27 June 2018
Resolved
Make galley water tight door audible alarm operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 June 2018
Resolved
Provide retro reflective tape on life rings and repair identified holes.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2018
Resolved
Remove battery cables from bilge and provide supports every 24 inches.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2018
Resolved
Provide cotter pins for both sides of all turnbuckles.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2018
Resolved
Provide preventitive maintenance plan.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 August 2017
Resolved
Haul out vessel for Dry Dock and Internal Structural Exam by Coast Guard Marine Inspector. Provide rigging survey by third party surveyor and unstep mast for inspection by Marine Inspector.
Fire Fighting › Fire Pumps › Pressure
Issued 27 March 2017
Resolved
Replace pressure gauge on fire pump.
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 27 March 2017
Resolved
Provide B-15 shielding around galley stove prior to operation of stove.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 March 2017
Resolved
Replace wasted waterlight line on port ring buoy.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 27 March 2017
Resolved
Provide licensed master's credentials prior to 01APR17.
Fire Fighting › Fire Pumps › Pressure
Issued 21 March 2017
Resolved
Provide proof that fire pump maintains 60 PSI of pressure.
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 March 2017
Resolved
Repair faulty bilge alarms.
Sail Rigging › Chainplates › Materials
Issued 21 March 2017
Resolved
Provide final report of 3rd party sail rigging survey.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 31 May 2016
Resolved
Renew lower deck support beam in forward compartment
Engineering › Fuel Oil Service System › Filter
Issued 31 May 2016
Resolved
Install flame shield and metal plug on generator prime mover secondary fuel filter.
Fire Fighting › Fire Pumps › Pressure
Issued 31 May 2016
Resolved
Prove proper operation of the fire pump
Engineering › Freshwater System (cylinder head cooling) › Sensor
Issued 31 May 2016
Resolved
Prove proper operation of the main engine jacket water gauge located at the operating station.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 31 May 2016
Resolved
Renew main engine sea strainer.
Documentation › Certificates/Documents › Stability Letter
Issued 29 May 2012
Resolved
Obtain a Stability Letter Addendum from Marine Safety Center and until it is received the total number of person allowed is reduced down to 76.
Documentation › Logs/Records › Drug Test Records
Issued 29 May 2012
Resolved
Complete DAPI audit - provide yearend report and proof of MIS fwd to COMDT by 15MAR.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 29 May 2012
Resolved
Replace M/E raw water coolant hoses.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 May 2012
Resolved
Label E- lighting station with red E.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 29 May 2012
Resolved
Clean grease IWO galley stove.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 29 May 2012
Resolved
Repair galley stove hand rail.
Electrical › Electric Supply System (service) › Cable
Issued 27 September 2011
Resolved
Replace all Welding cable with approved Marine Grade Cable.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 27 September 2011
Resolved
Make aft engineroom overhead vapor tight
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 April 2009
Resolved
Make vessel available for hull exam in accordance with 46 CFR 176.600
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 1 April 2009
Resolved
Hydrostatic release expired.
Engineering › Lubricating Oil Service System › Gauge
Issued 1 April 2009
Resolved
Repair MDE L/O PSI gauge
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 13 November 2008
Resolved
Provide adequate means of structural fire protection for wooden barrier on the right side of LPG stove in galley IAW 46CFR177.410(a). Vessel prohibited from using stove until rectified.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 November 2008
Resolved
Provide cover for exposed fixed light in "B" compartment accommodation space IAW 46CFR183.200(b).
Documentation › Certificates/Documents › FCC SSL
Issued 3 November 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 3 November 2008
Resolved
Repair/renew revolution per minute (RPM) gauge for main engine at local gauging station as per 46CFR182.410 (b).
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 4 June 2007
Resolved
Repair leak in the sewage holding tank in the Alpha compartment.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 June 2007
Resolved
Remove/cap dead end wires throughout the vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 June 2007
Resolved
Make DC terminal block in the engine room dripproof IAW 46 CFR 183.210.
Deck/Cargo › Holds/Tanks › Hatch
Issued 4 June 2007
Resolved
Provide securing devices for all hatches on the main deck IAW 46 CFR 179.360.
Engineering › Bilge Water Management System › Hose
Issued 4 June 2007
Resolved
Renew deterioated hose for the MDE driven bilge pump.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 February 2007
Resolved
[name withheld] notified owner on 14 FEB 2007 that the vessel was overdue for a hull inspection. Wrote a CG-835, no sail to vessel until a hull examination was completed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 February 2007
Resolved
From hull examination work list item # 01, dated 21FEB07, repair wood rot and cracking on bulwark under deck railing throughout vessel to provide safety of passengers and crew IAW 46 CFR 177.900.
Construction/Loadline › Hull › Longitudinal Frame
Issued 20 February 2007
Resolved
Repair wood where bolt penetration on port bow frame.
Construction/Loadline › Structures › Superstructure
Issued 20 February 2007
Resolved
Repair billet head rotted wood area.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 24 January 2005
Resolved
Renew 30X30 mesh flame screen on fuel tank vent pipe.
Engineering › Pressure Vessel › Marking and Stamping
Issued 24 January 2005
Resolved
Remove or replace existing air receiver with ASME approved pressure vessel to U or UM designation IAW CFR 182.330.
Electrical › Electric Generation Source (service) › Generator
Issued 24 January 2005
Resolved
Renew ammeter on Lister generator IAW 183.320(c).
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 23 October 2003
Resolved
Missing "Emergency Escape Keep Clear" sign posted at escape hatch.
Construction/Loadline
Issued 23 October 2003
Resolved
Wood rot noticed on interior of vessel around all glass view prisms on deck. Required operator to treat all rotted areas.
Lifesaving › Inflatable Liferafts
Issued 10 October 2002
Resolved
IBA not serviced within last 12 months.
Construction/Loadline › Structures
Issued 10 October 2002
Resolved
Replace broken glass in skylight leading into galley.
Construction/Loadline › Structures
Issued 10 October 2002
Resolved
Make forward hatch weathertight. LEGACY COMPONENT DESC: Door
Operations/Management › Drug and Alcohol Testing
Issued 10 October 2002
Resolved
EAP not in accorance with 46 CFR 16.401. LEGACY COMPONENT DESC: EAP Training Requirements
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 10 October 2002
Resolved
Copy of MIS not retained.
Construction/Loadline
Issued 18 October 1999
Resolved
In fore peak berthing area make hole in way of aft bulkhead, port side, upper that passes bilge alarm wiring water tight.
Documentation
Issued 18 October 1999
Resolved
Provide proff of 60 minute of supervisory E.A.P. training per 46/16.401.
Documentation
Issued 18 October 1999
Resolved
Provide proof of available 24 HR collection facility or 6 urine sampling kits onboard vessel, per 46/16.240.
Documentation
Issued 18 October 1999
Resolved
Missing Station Bill.
Electrical
Issued 18 October 1999
Resolved
Missing cover for electrical panel on back of control at steering station.
Accommodation/Occupational Safety
Issued 18 October 1999
Resolved
Provide Holding tank/MSD for or remove toilet in captain's cabin - over board discharge to remain locked and toilet not in use until corrected.
Documentation
Issued 18 October 1999
Resolved
Complete and submit M.I.S. per 46/16.500.
Lifesaving
Issued 6 February 1999
Resolved
SERVICE LIFERAFTS.
Lifesaving
Issued 6 February 1999
Resolved
PROVIDE LIGHTS ON ALL LIFEJACKETS.
Lifesaving
Issued 6 February 1999
Resolved
REPAINT VESSEL NAME ON LIFE BUOYS.
Navigation
Issued 6 February 1999
Resolved
PROVIDE CURRENT TIDE TABLES.
Fire Fighting
Issued 6 February 1999
Resolved
SERVICE FIRE EXTINGUISHERS.
Navigation
Issued 6 February 1999
Resolved
PROVIDE CURRENTLY CORRECT CHARTS, COAST PILOT AND LIGHT LIST.
Documentation
Issued 6 February 1999
Resolved
PROVIDE PROOF OF SATISFACTORY DRUG PROGRAM.
Lifesaving
Issued 6 February 1999
Resolved
PROVIDE "EPIRB" TEST LOG.
Lifesaving
Issued 6 February 1999
Resolved
PROVIDE (6) NEW RED HAND FLARES.
Lifesaving
Issued 6 February 1999
Resolved
RENEW RETROFLECTIVE TAPE ON APPROX (10) LIFEJACKETS.
Navigation
Issued 28 October 1996
Resolved
PROVIDE UL APPROVED NAVIGATION LIGHTS._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 28 October 1996
Resolved
PROPERLY INSTALL INSULATION ON THE STBD ENGINE EXHAUST, JUST AFT OF THE MANIFOLD.
Lifesaving
Issued 28 October 1996
Resolved
POST LIFEJACKET PLACARD FOR TYPE OF LIFEJACKETS ABOARD.
Electrical
Issued 13 October 1995
Resolved
UPON INSPECTION OF ELECTRICAL PANEL, POSSIBLE DECK WEEPAGE NOTED. CG-835 ISSUED TO ALTER REPLACE PANEL AND REPAIR DECK PRIOR TO 31 OCT 96 TO MEET COAST GUARD REQUIREMENTS.
Navigation
Issued 13 October 1995
Resolved
CURRENT WHEEL BOX DESIGN DOES NOT ALLOW FOR TILLER ARM ATTACHMENT. COULD NOT TEST EMERGENCY STEERING. IN EVENT OF STEERING CASUALTY, BACK WALL OF BOX WOULD HAVE TO BE KNOCKED OUT TO ATTACH TILLER ARM. CG-835 ISSUED TO MODIFY WHEEL BOX PRIOR TO 31 OCT 96 TO ALLOW FOR ATTACHMENT.
Navigation
Issued 13 October 1995
Resolved
VESSEL DID NOT HAVE CURRENT AREA CHARTS, LIGHT LIST AND COAST PILOT.
Electrical
Issued 13 October 1994
Resolved
REPAIR/REPLACE ELECTRICAL JUNCTION BOX LOCATED IN FORWARD ACCOMMODATION SPACE, STARBOARD SIDE.
Documentation
Issued 13 October 1994
Resolved
PROVIDE INFORMATION REGARDING CHEMICAL TESTING IN ACCORDANCE WITH 46 CODE OF FEDERAL REGULATIONS PART 16.
Lifesaving
Issued 6 October 1993
Resolved
CONDUCT UNDERWAY LIFE SAVING DRILL IN THE PRESENCE OF CG MARINE INSPECTOR.
Electrical
Issued 13 October 1992
Resolved
Provide and install rear housing assembly for Lister engine generator on deck.
Engineering
Issued 13 October 1992
Resolved
Demonstrate proper operation of Tachometer for main propulsion engine.
Electrical
Issued 13 October 1992
Resolved
Make proper repair to oil pressure guage on Lister deck engine.
Documentation
Issued 15 October 1991
Resolved
Provide fcc operators permit.
Navigation
Issued 15 October 1991
Resolved
Demonstrate proper operation of starboard running light.
Navigation
Issued 15 October 1991
Resolved
Provide current charts and light list for area.
Navigation
Issued 15 October 1991
Resolved
Demonstrate operation of emergency steering._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 15 October 1991
Resolved
Provide 01 adult PFD.
Lifesaving
Issued 1 July 1991
Resolved
PROVIDE ONE CHILD PFD. NUMBER OF CHILDREN PERMITTED TO BE CARRIED IS FIVE
Engineering
Issued 1 July 1991
Resolved
PROVIDE FUEL FILTER HEAT SHIELD FOR RACOR FUEL FILTER
Engineering
Issued 1 July 1991
Resolved
INSTALL 30X30 MESH FLAME SCREEN IN PORT FUEL TANK VENT
Construction/Loadline
Issued 1 July 1991
Resolved
RECALK TRANSOM. ROUTE RESTRICTED TO LBS UNTIL COMPLETED.
Fire Fighting
Issued 1 July 1991
Resolved
INSTALL REMOTE RELEASE DEVICE FOR INSTALLED FIXED HALON PRIOR TO 1AUG91
Construction/Loadline
Issued 31 October 1990
Resolved
B. INSTALL ON INDICATOR LIGHT FOR EACH DOOR AT THE OPERATORS STATION WHICH WARNS WHEN THE DOOR IS OPEN
Documentation
Issued 31 October 1990
Resolved
PROVIDE FCC OPERATORS LICENSE
Electrical
Issued 31 October 1990
Resolved
DEMONSTRATE 12VDC EMERGENCY LIGHTING
Lifesaving
Issued 31 October 1990
Resolved
PROVIDE SIX ORANGE FLARES
Lifesaving
Issued 31 October 1990
Resolved
PROVIDE 4 ADULT AND 2 CHILD'S PFD'S
Fire Fighting
Issued 31 October 1990
Resolved
INSTALLED FIXED HALON SYSTEM MUST SHUT DOWN DIESEL ENGINE UPON ACTIVIATION AND PRIOR TO RELEASE OF AGENT
Fire Fighting
Issued 31 October 1990
Resolved
INSTALLED FIXED HALON SYSTEM MUST SHUT DOWN VENTILATION SYSTEM UPON ACTIVATION AND PRIOR TO RELEASE OF AGENT
Construction/Loadline
Issued 31 October 1990
Resolved
FOR THE TWO WATERTIGHT DOORS BETWEEN MAIN SALON AND "B" COMPARTMENT AND "B"COMPARTMENT AND "A" COMPARTMENT: A. MARK ON BOTH SIDES IN AT LEAST ONE INCH LETTERS: "WATERTIGHT DOOR - KEEP CLOSED AT ALL TIMES WHEN TRANSITING"
Fire Fighting
Issued 31 October 1990
Resolved
INSTALLED FIXED HALON SYSTEM MUST BE ABLE TO BE MANUALLY ACRTIVATED WITH A REMOTE RELEASE DEVICE
Electrical
Issued 31 October 1990
Resolved
BLOCK LISTER BATTERY COMPARTMENT
Electrical
Issued 31 October 1990
Resolved
CORRECTLY WIRE FIRE PUMP/BATTERY CHARGER
Lifesaving
Issued 31 October 1990
Resolved
MARK ON DECK OFD STOWAGE AND CHILD'S PFD STOWAGE
Engineering
Issued 31 October 1990
Resolved
CONDUCT UNDERWAY TEST IN PRESENCE OF CG MARINE INSPECTOR
Navigation
Issued 31 October 1990
Resolved
DEMONSTRATE ALL ELECTRONICS
Fire Fighting
Issued 31 October 1990
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUIHERS
Engineering
Issued 31 October 1990
Resolved
REPAIR "A" COMPARTMENT EDISON HAND BILGE PUMP
Navigation
Issued 31 October 1990
Resolved
DEMONSTRATE ALL NAVIGATION LIGHTS
Unknown
Issued 15 November 1989
Resolved
SERVICE LIFERAFTS BY 1JAN90
Unknown
Issued 15 November 1989
Resolved
ADJUST STARBOARD RUNNING LIGHT SOCKET SO AS TO PLACE BULB IN CENTER OF LENS
Unknown
Issued 15 November 1989
Resolved
PROVIDE ONE ADDITIONAL B-II SIZE FIRE EXTINGUISHER ON VESSEL
Unknown
Issued 15 November 1989
Resolved
PROVIDE TWO ADDITIONAL ADULT PFD'S ON BOARD VESSEL
Unknown
Issued 15 November 1989
Resolved
RENEW FCC SAFETY CERTIFICATE
Unknown
Issued 15 November 1989
Resolved
PROVIDE ONE NEW LIFERING (24" DIAM) ON BOARD VESSEL
Unknown
Issued 15 November 1989
Resolved
PREPACK VALVE STEM ON FIRE STATION PORT
Fire Fighting
Issued 5 January 1989
Resolved
SUBMIT WRITTEN PROPOSAL FOR REPLACING PVC PIPE IN FIREMAIN WITH METALLIC PIPE AND FOR CROSS-CONNECTING TWO FIRE HYDRANTS, OR PROVIDE CERTIFICATION THAT EXISTING INSTALLATION HAS BEEN APPROVED. WRITTEN PROPOSAL SHOULD INCLUDE TIMETABLE, SKETCH OF SYSTEM, MATERIALS USED, AND LOCATION OF REPAIR
Fire Fighting
Issued 5 January 1989
Resolved
INSTALL PRESSURE GUAGE AT DISCHARGE END OF 60 PSI, 50 GPM, FIXED, POWER, FIRE PUMP.
Fire Fighting
Issued 5 January 1989
Resolved
EFFECT ALTERATIONS TO FIRE MAIN SYSTEM IN ACCORDANCE WITH APPROVED PLANS SUBMITTED 20JAN89 AND [name withheld] LETTER 16711/D533074 DATED 01FEB89.
Lifesaving
Issued 5 January 1989
Resolved
PROVIDE ONE ADDITIONAL ADULT LIFE PRESERVER.
Fire Fighting
Issued 5 January 1989
Resolved
PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER OR EQUIVALENT FIXED FIRE- FIGHTING SYSTEM IN ENGINEROOM.
Fire Fighting
Issued 19 July 1988
Resolved
RENEW #2 FIRE MAIN COUPLING LOCATED JUST INBOARD OF THROUGH HULL FITTING.
Construction/Loadline
Issued 19 July 1988
Resolved
RENEW PLANKING AS FOLLOWS: A. STARBOARD PLANK #14 BETWEEN FRAMES #34 AND #52. B. PORT PLANK #20 BETWEEN FRAMES #46 AND #59
Construction/Loadline
Issued 2 February 1988
Resolved
PLANKS TO BE RENEWED ON STBD SIDE AS FOLLOWS: PLANK 23 STEM TO FRAME 3,PLANK 22 STEM TO FRAME 5,PLANK 21 STEM TO FRAME 7 PLANK 20 STEM TO FRAME 5,PLANK 19 STEM TO FRAME 3,PLANK 18 STEM TO FRAME 5 PLANK 17 STEM TO FRAME 8,PLANK 16 STEM TO FRAME 3,PLANK 15 STEM TO FRAME 11
Construction/Loadline
Issued 2 February 1988
Resolved
PLANKS TO BE RENEWED ON STBD SIDE AS FOLLOWS: PLANK 14 STEM TO FRAME 5,PLANK 13 STEM TO FRAME 9,PLANK 12 STEM TO FRAME 14PLANK 11 STEM TO FRAME 11.
Construction/Loadline
Issued 2 February 1988
Resolved
PLANKS TO BE RENEWED ON PORT SIDE AS FOLLOWS: PLANK 23 STEM TO FRAME 4 PLANK 22 STEM TO FRAME 7,PLANK 21 STEM TO FRAME 9,PLANK 20 STEM TO FRAME 7 PLANK 19 STEM TO FRAME 5,PLANK 18 STEM TO FRAME 11,PLANK 17 STEM TO FRAME 9PLANK 16 STEM TO FRAME 7,PLANK 15 STEM TO FRAME 5,PLANK 14 STEM TO FRAME 3
Construction/Loadline
Issued 2 February 1988
Resolved
PLANKS TO BE RENEWED ON PORT SIDE AS FOLLOWS: PLANK 15 FRAME 31 TO 47, PLANK 14 FRAME 34 TO 40, PLANK 13 FRAME 36 TO 45 PLANK 12 FRAME 35 TO 42, PLANK 11 FRAME 32 TO 40, PLANK 10 FRAME 31 TO 43 PLANK 9 FRAME 35 TO 46, PLANK 8 FRAME 33 TO 42, PLANK 7 FRAME 32 TO 44
Construction/Loadline
Issued 2 February 1988
Resolved
PLANKS TO BE RENEWED ON PORT SIDE AS FOLLOWS: PLANK 6 FRAME 30 TO 51, PLANK 5 FRAME 38 TO 44.
Construction/Loadline
Issued 2 February 1988
Resolved
FRAMES TO BE RENEWED AS FOLLOWS: PORT SIDE COMPLETE #1 FRAME, TOP TIMBER OF #2 FRAME, FUTTOCKS OF #37, #38, #39 AND #40. STARBOARD SIDE COMPLETE #1 FRAME.
Engineering
Issued 2 February 1988
Resolved
RENEW THE FOREMAST.
Construction/Loadline
Issued 2 February 1988
Resolved
RENEW THE CEILING, BILGE CLAMP, SHELF AND DECKING AT BOW, SCARFING STENGTH MEMBERS INTO GOOD WOOD AS APPROPRIATE. ALSO RENEW THE CEILING IN WAY OF FRAME #37 THRU #40, AGAIN SCARFING NEW MEMBERS INTO GOOD WOOD AS APPROPRIATE.
Construction/Loadline
Issued 3 June 1985
Resolved
RENEW/REPAIR TWO (2) MUSHROOM VENTS AT FOREPEAK.
Casualty record · 2
14 April 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2523315
8 September 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 4441145
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.