Records from 2012 to 2026. Most recent: inspection, 11 August 2026.
Documentation record
Registered dimensions (L × B × D)78.0 ft × 26.5 ft × 7.1 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHALTER MARINE · NEW ORLEANS, LA, UNITED STATES · built 1971
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFORT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 22 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
11 August 2026
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8461829
13 January 2026
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8295401
15 October 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8253162
22 January 2025
Administrative Inspection · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8067299
1 February 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7858747
29 September 2023
Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7806882
10 May 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7685450
8 November 2022
Internal Structural Exam · Administrative Inspection · Examination of Repairs · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7579443
1 December 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7360008
13 October 2021
Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7331904
16 February 2021
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7141401
10 February 2020
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6904919
23 October 2019
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6851409
26 August 2019
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6794797
25 February 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6629722
7 December 2017
COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6310584
3 October 2017
Spot Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6280264
21 November 2016
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6044935
2 May 2016
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5867574
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 13 January 2026
Resolved
All vessels shall be provided with bilge pumps IAW Table 182.25-10(a).
Replace check valve for engine room bilge suction.
46CFR182.25-10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2026
Resolved 17 January 2026
Resolution: Bilge piping repaired.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 January 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Charts of large enough scale to make safe navigation possible.
Paper charts must be ENC-Derived Paper Charts. If Electronic chart plotter is utilized, it must be 7.8" X 7.8" display. CG NVIC 01-16-Ch-3 guidance to be forwarded for clarification.
46 CFR 184.420(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2026
Resolved 17 January 2026
Resolution: Charts purchased.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 January 2026
Resolved
Suitable storm rails or hand grabs shall be installed where necessary in all passageways, at deckhouse sides, and at ladders and hatches where passengers or crew might have normal access.
Repair stanchions identified during inspection and previous DD/ISE.
46CFR177.35-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2026
Resolved 17 January 2026
Resolution: Railing repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 January 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection ....
Rusted holes were found in engine room bilge, rust holes through the fire hose stanchion on the third deck and a temporary repair on the the starboard side generator exhaust line in the lazerette.
46 CFR 177.100 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2025
Resolved 20 February 2025
Resolution: Vessel provided proof of acceptable schedule 80 piping
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 January 2025
Resolved
The pump outlet must be fitted with a pressure gauge.
Vessel Fire pump gauge was inoperable
46 CFR 181.300(b)
16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2025
Resolved 27 January 2025
Resolution: Submitted picture gauge was replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2025
Resolved
Each battery must be ...secured to protect against shifting with the roll and pitch of the vessel...
Multiple batteries were found without a secured tops.
46 CFR 183.350(b)
16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2025
Resolved 27 January 2025
Resolution: Submitted picture batteries were secured
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 January 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazard...
Multiple open ended wires were found throughout the engine room.
46 CFR 183.200(b)
16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2025
Resolved 21 February 2025
Resolution: Wires repaired to the satisfaction of CG MI.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 November 2022
Resolved
The inspection shall be such as to insure that the arrangement, materials and scantlings of the structure , piping, main and aux machinery... comply with the regulations in this sub chapter. During vessels material inspection, MIs identified the following items;
1. Excessive wastage in top plate of fuel tank and aft bulkhead of compartment. Clean area to bear metal and take gauging measurements to asses condition.
2. Fuel tank pick up pipe is severely wasted. Clean to bear metal for inspection and preserve.
3. Two holes near PORT side deck drain in fuel tank compartment and one near deck drain STBD side in fore peak. Make proper repairs.
46 CFR 176.05-5(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2022
Resolution: MI witnessed proper repairs.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 November 2022
Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. Steering gear system is misaligned causing contact in STBD rudder post. Complete proper repairs.
46 CFR 182.30-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2022
Resolution: MI witnessed proper repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 November 2022
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. MIs identified two of the lifebuoys on board were not serviceable. Replace with serviceable life buoys.
46 CFR 117.70 (a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2022
Resolution: Operator replaced with new life buoys.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 February 2021
Resolved
Vessel failed to carry out satisfactory bilge pump test of fuel tank compartment. Vessel must conduct satisfactory test of the bilge pump test from fuel tank compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2021
Resolution: Observed satisfactory bilge pump test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 February 2021
Resolved
Incorrect size life buoy for vessel's route of service. Provide three 24" ring buoys and place them into proper service.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2021
Resolution: Vessel equipped with three 24" ring buoys.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 February 2021
Resolved
Vessel missing one 10BC portable fire extinguisher on 2nd deck concession stand. Install 10bc portable fire extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2021
Resolution: Observed new portable fire extinguisher installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2021
Resolved
Install metal support brackets for electrical wires on 2nd deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2021
Resolution: Metal support brackets installed on 2nd deck for electrical wires running overhead.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 February 2021
Resolved
Replace broken portable fire extinguisher bracket located on main deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2021
Resolution: New portable fire extinguisher bracket installed on main deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2019
Resolved
Vessel has 100 type II lifejackets onboard.Vessel required to have Type I per Subchapter Q specs.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 6 March 2019
Resolution: Recieved proof of lifejacket replacement.
Construction/Loadline › Penetrations › Valve Flange
Issued 7 December 2017
Resolved
Shutoff Valves for generator not installed
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 19 December 2017
Resolution: See photos
Engineering › Steering Gear System › Rudder Stock
Issued 7 December 2017
Resolved
Gusset missing for rudder post / top
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 8 February 2018
Construction/Loadline › Hull › Bottom Plating
Issued 12 October 2017
Resolved
Vessel to submit repair proposal for all wasted areas indicated.
Action required: 705 - Other - as specified
Resolved 16 October 2017
Resolution: Vessel submitted acceptable repair proposal.
Engineering › Thrusters › Shaft
Issued 2 May 2016
Resolved
Provide shaft alignment report (and port prop servicing and vibration report).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 3 June 2016
Resolution: recieved all three reports and attached copies to this activity.