MAURY USCG vessel records Sign in
← All vessels

JUNGLE QUEEN IV

JUNGLE QUEEN IV is a 1971 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1985, most recently in August 2026, along with 211 deficiencies, 1 operational control and 1 casualty investigation in 2012.

Records from 1985 to 2026. Most recent: inspection, 11 August 2026.

Built
1971
Last inspected
11 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI9827
Flag
UNITED STATES
367752540
Maury page id
psix-46913

Inspections, by type

…with no type recorded9
Years with a record 39 calendar years (1985–2026)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)78.0 ft × 26.5 ft × 7.1 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHALTER MARINE SERVICES INC · NEW ORLEANS, LA, UNITED STATES · built 1971
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI9827MMSI 367752540 · active · voluntarily equipped · granted 26 August 2016, expires 26 August 2026
WDC9889MMSI 367107980 · expired · compulsorily equipped · granted 19 April 2006, cancelled 25 June 2016
WTY9126MMSI not assigned · expired · compulsorily equipped · granted 23 January 1996, cancelled 3 June 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 81

11 August 2026 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8461829
13 January 2026 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8295401
15 October 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8253162
22 January 2025 Administrative Inspection · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8067299
1 February 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7858747
29 September 2023 Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7806882
10 May 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7685450
8 November 2022 Internal Structural Exam · Administrative Inspection · Examination of Repairs · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7579443
1 December 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7360008
13 October 2021 Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7331904
16 February 2021 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7141401
10 February 2020 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6904919
23 October 2019 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6851409
26 August 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6794797
25 February 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6629722
7 December 2017 COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6310584
3 October 2017 Spot Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6280264
21 November 2016 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6044935
2 May 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5867574
17 November 2015 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5765750
10 November 2015 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5760870
15 September 2015 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5720217
7 August 2014 In-Service Inspection · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4959589
4 January 2012 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4218021
7 September 2011 Hull Examination · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4137782
13 September 2010 MTSA Verification · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3846695
21 January 2010 Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3666851
18 July 2008 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3271603
27 February 2008 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3154630
7 November 2007 Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3093252
11 September 2007 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3051656
18 September 2006 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2779150
15 November 2005 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2534838
2 September 2005 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2486441
2 November 2004 Damage Survey · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2234544
20 October 2004 Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2224007
11 May 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2065092
12 March 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2023407
28 April 2003 COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1781828
17 November 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1708772
10 June 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1628598
23 May 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1619896
18 April 2002 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1606028
1 May 2001 Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1422053
11 May 2000 Deficiency Check · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1417055
28 April 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1427817
25 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 779963
11 May 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 795446
29 April 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1404742
26 April 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1457641
30 April 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 790052
20 April 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1123440
31 October 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 31003
29 October 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1110800
12 May 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1094888
29 April 1996 COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1085942
10 October 1995 Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 878707
30 June 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1190597
15 May 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1234538
4 February 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 159084
25 November 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 108337
1 October 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 16516
12 August 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 864035
26 May 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1170604
24 November 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1161661
29 May 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1149128
6 May 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1134578
28 May 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 952471
28 May 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1268232
7 May 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 945343
10 April 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 943586
6 May 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1310887
21 September 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1222364
9 May 1990 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1240903
19 September 1989 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1197678
9 May 1989 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1340033
10 May 1988 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1345453
13 May 1987 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1324220
17 November 1986 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1010511
13 May 1986 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1299630
17 May 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 984356

Deficiency record · 211

04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 13 January 2026 Resolved
All vessels shall be provided with bilge pumps IAW Table 182.25-10(a). Replace check valve for engine room bilge suction. 46CFR182.25-10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2026
Resolved 17 January 2026
Resolution: Bilge piping repaired.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 January 2026 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Charts of large enough scale to make safe navigation possible. Paper charts must be ENC-Derived Paper Charts. If Electronic chart plotter is utilized, it must be 7.8" X 7.8" display. CG NVIC 01-16-Ch-3 guidance to be forwarded for clarification. 46 CFR 184.420(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2026
Resolved 17 January 2026
Resolution: Charts purchased.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 January 2026 Resolved
Suitable storm rails or hand grabs shall be installed where necessary in all passageways, at deckhouse sides, and at ladders and hatches where passengers or crew might have normal access. Repair stanchions identified during inspection and previous DD/ISE. 46CFR177.35-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2026
Resolved 17 January 2026
Resolution: Railing repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 January 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection .... Rusted holes were found in engine room bilge, rust holes through the fire hose stanchion on the third deck and a temporary repair on the the starboard side generator exhaust line in the lazerette. 46 CFR 177.100 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2025
Resolved 20 February 2025
Resolution: Vessel provided proof of acceptable schedule 80 piping
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 January 2025 Resolved
The pump outlet must be fitted with a pressure gauge. Vessel Fire pump gauge was inoperable 46 CFR 181.300(b) 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2025
Resolved 27 January 2025
Resolution: Submitted picture gauge was replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2025 Resolved
Each battery must be ...secured to protect against shifting with the roll and pitch of the vessel... Multiple batteries were found without a secured tops. 46 CFR 183.350(b) 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2025
Resolved 27 January 2025
Resolution: Submitted picture batteries were secured
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 January 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazard... Multiple open ended wires were found throughout the engine room. 46 CFR 183.200(b) 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2025
Resolved 21 February 2025
Resolution: Wires repaired to the satisfaction of CG MI.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 November 2022 Resolved
The inspection shall be such as to insure that the arrangement, materials and scantlings of the structure , piping, main and aux machinery... comply with the regulations in this sub chapter. During vessels material inspection, MIs identified the following items; 1. Excessive wastage in top plate of fuel tank and aft bulkhead of compartment. Clean area to bear metal and take gauging measurements to asses condition. 2. Fuel tank pick up pipe is severely wasted. Clean to bear metal for inspection and preserve. 3. Two holes near PORT side deck drain in fuel tank compartment and one near deck drain STBD side in fore peak. Make proper repairs. 46 CFR 176.05-5(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2022
Resolution: MI witnessed proper repairs.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 November 2022 Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. Steering gear system is misaligned causing contact in STBD rudder post. Complete proper repairs. 46 CFR 182.30-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2022
Resolution: MI witnessed proper repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 November 2022 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. MIs identified two of the lifebuoys on board were not serviceable. Replace with serviceable life buoys. 46 CFR 117.70 (a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2022
Resolution: Operator replaced with new life buoys.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 February 2021 Resolved
Vessel failed to carry out satisfactory bilge pump test of fuel tank compartment. Vessel must conduct satisfactory test of the bilge pump test from fuel tank compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2021
Resolution: Observed satisfactory bilge pump test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 February 2021 Resolved
Incorrect size life buoy for vessel's route of service. Provide three 24" ring buoys and place them into proper service.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2021
Resolution: Vessel equipped with three 24" ring buoys.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 February 2021 Resolved
Vessel missing one 10BC portable fire extinguisher on 2nd deck concession stand. Install 10bc portable fire extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2021
Resolution: Observed new portable fire extinguisher installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2021 Resolved
Install metal support brackets for electrical wires on 2nd deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2021
Resolution: Metal support brackets installed on 2nd deck for electrical wires running overhead.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 February 2021 Resolved
Replace broken portable fire extinguisher bracket located on main deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2021
Resolution: New portable fire extinguisher bracket installed on main deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2019 Resolved
Vessel has 100 type II lifejackets onboard.Vessel required to have Type I per Subchapter Q specs.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 6 March 2019
Resolution: Recieved proof of lifejacket replacement.
Construction/Loadline › Penetrations › Valve Flange
Issued 7 December 2017 Resolved
Shutoff Valves for generator not installed
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 19 December 2017
Resolution: See photos
Engineering › Steering Gear System › Rudder Stock
Issued 7 December 2017 Resolved
Gusset missing for rudder post / top
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 8 February 2018
Construction/Loadline › Hull › Bottom Plating
Issued 12 October 2017 Resolved
Vessel to submit repair proposal for all wasted areas indicated.
Action required: 705 - Other - as specified
Resolved 16 October 2017
Resolution: Vessel submitted acceptable repair proposal.
Engineering › Thrusters › Shaft
Issued 2 May 2016 Resolved
Provide shaft alignment report (and port prop servicing and vibration report).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 3 June 2016
Resolution: recieved all three reports and attached copies to this activity.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 17 November 2015 Resolved
Repair inoperative port side running light.
Condition: Invalid
Due 18 November 2015
Resolved 18 November 2015
Resolution: Vessel repairedport side running light while inspectors were onboard.
Navigation › Piloting/Steering › Marine Charts
Issued 17 November 2015 Resolved
Provide updated charts and publications.
Condition: Invalid
Due 1 December 2015
Resolved 23 November 2015
Resolution: Vessel provided updated charts and publications.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 November 2015 Resolved
Provide serviceable port and starboard upper deck life rings.
Condition: Improper/Lack of Maintenance
Due 1 December 2015
Resolved 23 November 2015
Resolution: Vessel provided serviceable port and starboard upper deck life rings.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 17 November 2015 Resolved
Provide verification (size) of hydrostatic test on air receiver under pilothouse.
Condition: Invalid
Due 1 December 2015
Resolved 14 December 2015
Resolution: Vessel provided hydrostatic test results on air receiver under pilothouse.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 November 2015 Resolved
Renew all childrens' PFDs with SOLAS approved retroflective tape.
Condition: Improper/Lack of Maintenance
Due 1 December 2015
Resolved 23 November 2015
Resolution: Vessel renewed all childrens' PFDs with SOLAS approved retroflective tape.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 November 2015 Resolved
Provide PFD quantities are indicated where PFDs are stowed.
Condition: Improper Installation
Due 1 December 2015
Resolved 23 November 2015
Resolution: Vessel provided PFD quantities and indicated where PFDs are stowed.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 November 2015 Resolved
Provide operable overhead lighting in engine room.
Condition: Improper/Lack of Maintenance
Due 1 December 2015
Resolved 23 November 2015
Resolution: Vessel provided operable overhead lighting in engine room.
Engineering › Bilge Water Management System › Hose
Issued 17 November 2015 Resolved
Repair main deck line bilge suction and renew hose.
Condition: Improper/Lack of Maintenance
Due 1 December 2015
Resolved 23 November 2015
Resolution: Vessel repair main deck line bilge suction and renewed hose.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 November 2015 Resolved
Provide cover for exposed bow thruster electrical contactor.
Condition: Placed in Improper Service
Due 1 December 2015
Resolved 23 November 2015
Resolution: Vessel provided cover for exposed bow thruster electrical contactor.
Fire Fighting › Combustible Materials › Insulation
Issued 10 November 2015 Resolved
Install starboard side insulation and fuel oil shut-off valve insulation in engine room.
Condition: Improper Installation
Due 1 December 2015
Resolved 23 November 2015
Resolution: Vessel installed starboard side insulation and fuel oil shut-off valve insulation in engine room.
Construction/Loadline › Hull › Bottom Plating
Issued 15 September 2015 Resolved
Hole in hull under starboard generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 September 2015
Resolution: Verified correction of deficiency.
Construction/Loadline › Hull › Bottom Plating
Issued 15 September 2015 Resolved
Hole in hull in starboard forepeak, just forward of collision bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 September 2015
Resolution: Verified correction of deficiency.
Construction/Loadline › Hull › Side Shell
Issued 15 September 2015 Resolved
Holes in sideshell on starboard side behind rubrail in rope hold (#2 void).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 September 2015
Resolution: Verified correction of deficiency.
Construction/Loadline › Hull › Side Shell
Issued 15 September 2015 Resolved
Hole in sideshell starboard side lazarette just aft of bulkhead.
Action required: 705 - Other - as specified
Resolved 30 September 2015
Resolution: Verified correction of deficiency.
Construction/Loadline › Hull › Bottom Plating
Issued 15 September 2015 Resolved
Hole in hull starboard side of keel forward of fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 September 2015
Resolution: Verified correction of deficiency.
Construction/Loadline › Structures › Deck Plating
Issued 15 September 2015 Resolved
Holes in overhead on port side in fuel tank space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 September 2015
Resolution: Verified correction of deficiency.
Construction/Loadline › Structures › Deck Plating
Issued 15 September 2015 Resolved
Plugged thru-hull in deck (former vent) with rag stuffed in it. Properly remove deck penetration.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 30 September 2015
Resolution: Verified correction of deficiency.
Construction/Loadline › Hull › Bottom Plating
Issued 15 September 2015 Resolved
Descale and gauge hull plating under port shaft seal in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 September 2015
Resolution: Verified correction of deficiency.
Construction/Loadline › Hull › Side Shell
Issued 15 September 2015 Resolved
Gauge side shell behind starboard rub rail from stem to stern.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 September 2015
Resolution: Verified correction of deficiency.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 15 September 2015 Resolved
Gauge marked section of fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 September 2015
Resolution: Verified correction of deficiency.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 15 September 2015 Resolved
Renew port and starboard shaft log and strut cutlass bearings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 September 2015
Resolution: Verified correction of deficiency.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 September 2015 Resolved
Remove extension cords powering fans on second deck. Install proper/permanent wiring installation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 30 September 2015
Resolution: Verified correction of deficiency.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 7 August 2014 Resolved
Provide repair proposal for wasted e/r stbd side shell IWO stbd deck drain piping and under stbd main deck ventilation duct by next avail dry dock in Sept14.
Action required: 705 - Other - as specified
Resolved 5 September 2014
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 7 August 2014 Resolved
Crop and renew wasted e/r steel on stbd side shell as identified.
Action required: 705 - Other - as specified
Resolved 5 September 2014
Construction/Loadline › Structures › Deck Plating
Issued 7 August 2014 Resolved
Make stbd side m/d IWO vent duct available for insp.
Action required: 705 - Other - as specified
Resolved 5 September 2014
Stability › Incline Test › General
Issued 4 January 2012 Resolved
In accordance with CG-543 Policy Letter 11-03 (Dated April 8, 2011), submit certification information to Sector Miami OCMI, with a copy to the MSC, certifying compliance with the new Final Rule regarding Assumed Average Weight Per Person (AAWPP) of 185 lbs. MSC will review and verify the information provided and issue an addendum to the existing stability letter or a new stability letter.
Due 3 November 2012
Resolved 10 October 2012
Resolution: VP of operations for vessel''s company requested addendum to the Stability Letter from MSC. Recieved copy of Stability Letter Addendum sent by MSN dated 10COT12.
Fire Fighting › Fire Main › Material
Issued 13 September 2011 Resolved
Hard pipe fire main pipe where flex hose is installed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2011
Engineering › Bilge Water Management System › Piping
Issued 13 September 2011 Resolved
Hard pipe bilge piping where flex hose is installed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 September 2011 Resolved
Provide cover over battery start connections on stanchion inboard of stbd MDE.
Action required: 705 - Other - as specified
Due 21 October 2011
Resolved 12 October 2011
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2011 Resolved
Provide UT shots of Engine Room hull where identified.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2011
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2011 Resolved
C/Renew bottom plate engine room, starboard side outboard of MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2011
Construction/Loadline › Hull › Side Shell
Issued 7 September 2011 Resolved
Crop/renew to good metal and renew as original STBD side shell hull where holed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2011
Construction/Loadline › Structures › Deck Plating
Issued 7 September 2011 Resolved
Scale back and make available for USCG inspection both Port & STBD side main deck outboard of bulwark where identified by USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2011
Construction/Loadline › Hull › Stiffener
Issued 7 September 2011 Resolved
Crop to good metal and renew as original deck stantion tubes where wasted at base as identified Port & STBD main deck and FWD on 2nd deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2011
Construction/Loadline › Structures › Ventilators
Issued 7 September 2011 Resolved
Crop and renew as original Port & STBD vent cowling and vent frame.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2011 Resolved
Remove wasted external light fixture cover, AFT in line with 2nd deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2011
Construction/Loadline › Structures › Deck Plating
Issued 7 September 2011 Resolved
Scale back flange of overhead on 2nd deck where decorative work is attached and make available for USCG inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2011 Resolved
Make all exterior light fixtures water tight.
Action required: 705 - Other - as specified
Due 21 October 2011
Resolved 12 October 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 September 2011 Resolved
Remove dead end wire fwd and inboard of STBD MDE attached to overhead in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2011
Fire Fighting › Fire Main › Condition
Issued 7 September 2011 Resolved
Service fire main piping at FWD engine room bulkhead and lower elbow.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2011
Engineering › Bilge Water Management System › Piping
Issued 7 September 2011 Resolved
Service bilge line discharge side of STBD bilge pump and fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2011
Fire Fighting › Fire Main › Condition
Issued 7 September 2011 Resolved
Service fittings on discharge side of fire pump raw water strainer and replace wasted metal pipe at approx 1 foot away from discharge side of strainer.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2011
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 September 2011 Resolved
Degrease engine room and scale hull under fire pump raw water strainer, under STBD shaft and throughout E/R as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2011
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 7 September 2011 Resolved
Service fittings @ heat exchanger STBD engine room side shell.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2011
Electrical › Electrical Distribution System (service) › Cable
Issued 7 September 2011 Resolved
Relocate electrical cable run for head raw water pump outboard of STBD MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 September 2011
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 7 September 2011 Resolved
Crop to good metal both Port & STBD stern tube inboard leading edges and repair as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 September 2011 Resolved
Clean/degrease both Port & STBD SSDG & MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 September 2011
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 September 2011 Resolved
Make proper repairs to Port MDE exhaust pipe where cracked in way of lagging & raw water cooling Port outboard side of pipe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 September 2011 Resolved
Make repairs to Port MDE exhaust fiberglass baffle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 September 2011 Resolved
Replace Port MDE raw water cooling pipe outboard IWO overhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 September 2011 Resolved
Replace STBD MDE raw water hose of exhaust cooling and ENG cooling hose outboard side as marked in orange with approved J1942 hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2011 Resolved
Provide cover for light fixture aft engine room and a cage for light fixture just STBD & FWD of aft eng room light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2011
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 7 September 2011 Resolved
Crop & renew piping @ fuel tank & have a marine chemist certify the space prior to conducting hot work.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2011
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 September 2011 Resolved
Scale and gouge and reweld cap on Port Main engine & generator exhaust piping @ through Hull in Lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2011
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 September 2011 Resolved
Crop/renew to good metal longitudinal stringer #2 & #3 outboard of center vertical keel STBD side in Lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2011
Engineering › Steering Gear System › Bracket/Clamp
Issued 7 September 2011 Resolved
Crop/renew to good metal STBD steering gear support bracket in Lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2011
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 September 2011 Resolved
Crop/renew STBD side shell longitudinal #1 & #2 IWO FWD bulkhead in Lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2011
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 September 2011 Resolved
Crop/renew hand rails @ base in AFT & FWD stairs on Deck 2 leading up to Deck 3.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2011
Electrical › Electric Supply System (service) › Cable
Issued 13 September 2010 Resolved
Remove dead wire or properly terminate in junction box. Wire found on top of house stbd side.
Action required: 705 - Other - as specified
Due 27 September 2010
Resolved 29 September 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 September 2010 Resolved
Remove or renew rotten fancy wood work from upper deck over pilot house.
Action required: 705 - Other - as specified
Due 27 September 2010
Resolved 29 September 2010
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 September 2010 Resolved
Replace grab line on stbd ring buoy on house deck and replace battery in floating water light.
Action required: 705 - Other - as specified
Due 27 September 2010
Resolved 29 September 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 September 2010 Resolved
Renew both wasted upper stacks and ensure deck IWO stacks are sound.
Action required: 705 - Other - as specified
Due 27 September 2010
Resolved 29 September 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 September 2010 Resolved
Provide guard over belt on stbd generator.
Action required: 705 - Other - as specified
Due 27 September 2010
Resolved 29 September 2010
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 13 September 2010 Resolved
Remove or properly terminate dead end wire over tool box in engine room.
Action required: 705 - Other - as specified
Due 27 September 2010
Resolved 29 September 2010
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 September 2010 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 27 September 2010
Resolved 29 September 2010
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 September 2010 Resolved
Provide updated list from consortium showing all members enrolled in consortium for company (Jungle Queen). Five employees missing from list.
Action required: 705 - Other - as specified
Due 27 September 2010
Resolved 29 September 2010
Fire Fighting › Fire Pumps › Pressure
Issued 18 July 2008 Resolved
Provide a pressure gauge for fire pump on the discharge side to prove system operates 50 GPM at 60 PSI.
Due 5 August 2008
Resolved 31 July 2008
Documentation › Certificates/Documents › FCC SSL
Issued 18 July 2008 Resolved
Provide vessel bridge to bridge radiotelephone certificate IAW 33 CFR 26.03.
Due 5 August 2008
Resolved 31 July 2008
Fire Fighting › Fire Hoses › Condition
Issued 7 November 2007 Resolved
Replace wasted fire hose on third deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 November 2007
Resolved 7 November 2007
Construction/Loadline › Hull › Hull Plating
Issued 11 September 2007 Resolved
Repair steel plating that is wasted in area of port decking void #1.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 22 October 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 11 September 2007 Resolved
Replace wasted frame stbd of keel in void #1.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 22 October 2007
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 11 September 2007 Resolved
provide structural fire protection plan as closed boat or remove viser roll down panels.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 27 February 2008
Construction/Loadline › Structures › Deck Plating
Issued 11 September 2007 Resolved
Crop and renew five areas of overhead decking and crop and renew three longitudinal frames in void #2.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 22 October 2007
Construction/Loadline › Penetrations › Pipe Flange
Issued 11 September 2007 Resolved
Crop and repair stbd deck drain overboard piping in void #4.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 22 October 2007
Fire Fighting › Fire Main › Condition
Issued 11 September 2007 Resolved
Properly secure potable water pump and piping and secure firemain piping fwd engine room.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 22 October 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 11 September 2007 Resolved
Prove proper operation of sewage level alarm.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 7 November 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 September 2007 Resolved
Remove dead ended wires in void #5.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 22 October 2007
Construction/Loadline › Hull › Hull Plating
Issued 11 September 2007 Resolved
Clad weld two areas of the stbd hull. (Pits)
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 22 October 2007
Construction/Loadline › Hull › Bottom Plating
Issued 11 September 2007 Resolved
Make proper repairs to wasted areas IWO sewage tank and test in presence of marine inspector.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 22 October 2007
Construction/Loadline › Hull › Keel
Issued 11 September 2007 Resolved
Air test keel in presence of marine inspector
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 22 October 2007
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 11 September 2007 Resolved
Install draft marks or loading line fore and aft at 4 ft 1 inch as per requirement of vessel's stability letter.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 7 November 2007
Electrical › Electrical Distribution System (service) › Switchboard
Issued 18 September 2006 Resolved
Install proper drip shield and protective matting in front of switchboard.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 19 September 2006
Resolution: fax
Engineering › Bilge Water Management System › Piping
Issued 18 September 2006 Resolved
Properly mount bilge piping in #2 hold.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 19 September 2006
Engineering › Fuel Oil Service System › Valve
Issued 18 September 2006 Resolved
Provide proper spanner for Emergency F/O supply valve deck cover.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 19 September 2006
Resolution: fax
Engineering › Pressure Vessel › Relief Valve
Issued 18 September 2006 Resolved
Replace compressed air safety relief valve in engine room.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 19 September 2006
Resolution: fax
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 16 November 2005 Resolved
Present 543 adult and 55 child size life jackets for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2005
Resolved 17 November 2005
Engineering › Bilge Water Management System › Pump
Issued 16 November 2005 Resolved
Prove proper operation of Bilge de-watering pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2005
Resolved 17 November 2005
Construction/Loadline › Structures › Superstructure
Issued 16 November 2005 Resolved
Make proper repairs to portside smoke stack.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Engineering › Fuel Oil Service System › Valve
Issued 16 November 2005 Resolved
Remove all plastic pet cocks from all Racor filters.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 November 2005 Resolved
Provide current Coast Pilot and Light List.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 16 November 2005 Resolved
Fill out Emergency Broadcast Placard.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 16 November 2005 Resolved
Make proper electrical repairs to pilot house top lights, spot light, shore tie connection, pilot house junction box, and 110vac outlets.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 16 November 2005 Resolved
Post vessel's current Station Bill.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Electrical › Lighting (service) › Outlet Box
Issued 16 November 2005 Resolved
Remove power strip form pilot house.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 16 November 2005 Resolved
Provide complete First Aid Kit.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 16 November 2005 Resolved
Provide complete First Aid Kit.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 16 November 2005 Resolved
Replace all missing and broken fluorescent light covers.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 16 November 2005 Resolved
Properly mount ring life buoy water light bracket.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Engineering › Bilge Water Management System › Pump
Issued 16 November 2005 Resolved
Properly mount both bilge pumps in engine room.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 16 November 2005 Resolved
Properly mount high water level alarm in engine room.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Electrical › Electric Supply System (service) › Cable
Issued 16 November 2005 Resolved
Remove or properly wire electrical bilge pump in engine room
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 16 November 2005 Resolved
Provide visual indicators for all high water alarms at the operating station.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 November 2005 Resolved
Secure battery box covers in engine room and bow thruster room.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 November 2005 Resolved
Replace electrical junction box cover on bow thruster motor.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 16 November 2005 Resolved
Properly mount water temperature gauge on port main diesel engine.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 November 2005 Resolved
Remove power strip from bridge.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 16 November 2005 Resolved
Properly mount vhf, am/fm, and PA radios on bridge.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 6 December 2005
Construction/Loadline › Hull › Hull Plating
Issued 2 September 2005 Resolved
Crop to good metal and insert new plate IWO starboard forward void.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2005
Engineering › Steering Gear System › Rudder
Issued 2 September 2005 Resolved
Grind out and re-weld crack in rudder.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2005
Construction/Loadline › Penetrations › Pipe Flange
Issued 2 September 2005 Resolved
Crop out deck drain pipe IWO bow thruster room port side and replace as new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 2 September 2005 Resolved
Install covers on light fixtures throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 2 September 2005 Resolved
replace exhaust flexible hose starboard side aft.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 September 2005 Resolved
Properly mark emergency fuel shut off.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2005
Construction/Loadline › Hull › Hull Plating
Issued 2 September 2005 Resolved
Crop to good metal and repair hole in bottom plate IWO aft starboard side sewage tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2005
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 2 November 2004 Resolved
Make permanent repairs to cracks on both rudders prior to carrying passengers.
Condition: Unknown
Due 2 November 2004
Resolved 2 November 2004
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 20 October 2004 Resolved
Provide new Navigation Rules, Tide Tables and Light List
Condition: Placed in Improper Service
Due 20 November 2004
Resolved 16 November 2005
Operations/Management › Drills/Instruction › Fire
Issued 20 October 2004 Resolved
Post Station Bill at operating station.
Condition: Placed in Improper Service
Due 20 November 2004
Resolved 6 December 2005
Navigation › Piloting/Steering › Compass Deviation Table
Issued 20 October 2004 Resolved
Provide compass deviation table.
Condition: Placed in Improper Service
Due 20 November 2004
Resolved 16 November 2005
Resolution: Vessel on Rivers route, compass not required.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 October 2004 Resolved
Update 1st aid kit.
Condition: Placed in Improper Service
Due 20 November 2004
Resolved 3 November 2004
Lifesaving › Lifebuoys
Issued 18 April 2002 Resolved
Install 60ft of buoyant, U/V resistant line on ring life buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 26 April 2002
Resolved 18 April 2002
Lifesaving › Lifejacket/PFD (General)
Issued 18 April 2002 Resolved
Provide 21 additional adult PFD's and until such time, total persons allowed is reduced to 522. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 26 April 2002
Resolved 18 April 2002
Engineering › Bilge Water Management System
Issued 18 April 2002 Resolved
Permanently install bilge pump with proper wiring and connections. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 3 May 2002
Resolved 7 June 2002
Engineering › Bilge Water Management System
Issued 18 April 2002 Resolved
Permanently mount bilge pumps to base. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 3 May 2002
Resolved 7 June 2002
Engineering › Bilge Water Management System
Issued 18 April 2002 Resolved
Install check valves in all bilge suction lines. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 3 May 2002
Resolved 7 June 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 18 April 2002 Resolved
Provide fire extinguisher servicing report. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 1 May 2002
Resolved 7 June 2002
Unknown
Issued 28 April 2000 Resolved
REMOVE ALL FLAMMABLES FROM ENGINE ROOM AND PROVIDE SUITABLE STORAGE.
Condition: Unknown
Due 11 May 2000
Resolved 17 May 2000
Lifesaving
Issued 28 April 2000 Resolved
PROVIDE RETROREFLECTIVE TAPE ON ALL RING BUOYS.
Condition: Unknown
Due 11 May 2000
Resolved 17 May 2000
Electrical
Issued 28 April 2000 Resolved
PROVIDE BLANK PLATES ON ELECTRICAL PANELS LOCATED AT ENTRANCE TO ENGINE ROOM.
Condition: Unknown
Due 11 May 2000
Resolved 17 May 2000
Electrical
Issued 28 April 2000 Resolved
PROVIDE FLOURESCENT LIGHT COVERS FOR THE FOLLOWING LIGHTS: MAIN DECK, PORTSIDE AFT AND ENGINE ROOM.
Condition: Unknown
Due 11 May 2000
Resolved 17 May 2000
Fire Fighting
Issued 28 April 2000 Resolved
REPLACE 01 AND 02 DECK FIRE HOSES PRIOR TO OPERATING.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Fire Fighting
Issued 28 April 2000 Resolved
REPLACE FIRE PUMP PRESSURE SWITCH AND PROVE PROPER OPERATION OF FIRE PUMP TO SATISFACTION OF USCG INSPECTORS.
Condition: Unknown
Due 28 April 2000
Resolved 8 May 2000
Documentation
Issued 28 April 2000 Resolved
PROPERLY LOG REQUIRED CREW TRAINING AND DRILLS IAW 46 CFR 185.25.
Condition: Unknown
Due 11 May 2000
Resolved 17 May 2000
Documentation
Issued 28 April 2000 Resolved
PROVIDE CPR CERTIFICATION FOR AT LEAST 50% OF THE CREW.
Condition: Unknown
Due 11 May 2000
Resolved 17 May 2000
Unknown
Issued 28 April 2000 Resolved
PROVIDE APPROVED WIRE HANGERS IN ENGINE ROOM.
Condition: Unknown
Due 11 May 2000
Resolved 17 May 2000
Unknown
Issued 28 April 2000 Resolved
PROVIDE MACHINERY GUARDS ON THE PORT GENERATOR.
Condition: Unknown
Due 11 May 2000
Resolved 17 May 2000
Construction/Loadline
Issued 28 April 2000 Resolved
REPLACE BILGE MANIFOLD HASE ON UPPER CONNECTION TRANSFER PIPE.
Condition: Unknown
Due 11 May 2000
Resolved 17 May 2000
Fire Fighting
Issued 28 April 2000 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVE PROPER OPERATION OF FIRE PUMP FROM EITHER SOURCE OF POWER (PORT AND STARBOARD GENERAOTR).
Condition: Unknown
Due 8 May 2000
Resolved 8 May 2000
Engineering
Issued 28 April 2000 Resolved
REPLACE PORT GENERATOR AIR INTAKE HOSE.
Condition: Unknown
Due 11 May 2000
Resolved 17 May 2000
Fire Fighting
Issued 28 April 2000 Resolved
REPLACE FIRE PUMP PRESSURE GAUGE.
Condition: Unknown
Due 11 May 2000
Resolved 8 May 2000
Documentation
Issued 29 April 1999 Resolved
Correct drug testing procedure.
Condition: Unknown
Due 6 May 1999
Resolved 11 May 1999
Lifesaving
Issued 29 April 1999 Resolved
Provide visual indicator light of high bilge level alarm for two aft compts.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Engineering
Issued 20 April 1998 Resolved
PROVIDE RUN-OUT READINGS ON BOTH PROP SHAFTS IN ENGINEROOM.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Construction/Loadline
Issued 29 April 1996 Resolved
PROVE COMPLIANCE OF BILGE SYSTEM TO PUMP 50 GPM
Condition: Unknown
Due 29 May 1996
Resolved 9 May 1996
Unknown
Issued 29 April 1996 Resolved
COMPLY WITH DRUG TESTING PROGRAM.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Electrical
Issued 10 October 1995 Resolved
Make proper electrical connection at junction box forward starboard quarter.
Condition: Unknown
Due 24 October 1995
Resolved 25 October 1995
Construction/Loadline
Issued 10 October 1995 Resolved
Correct small leaks on 2 welded inserts as identified.
Condition: Unknown
Due 24 October 1995
Resolved 25 October 1995
Electrical
Issued 15 May 1995 Resolved
Prove proper operation of emergency lighting system. _x001C_ _Vessel operations are restricted to daylight hrs. only until corrected.
Condition: Unknown
Due 2 July 1995
Resolved 2 July 1995
Fire Fighting
Issued 15 May 1995 Resolved
Prove proper operation of fixed fire pump & system to 50 gpm at 60 psi.
Condition: Unknown
Due 2 July 1995
Resolved 2 July 1995
Lifesaving
Issued 15 May 1995 Resolved
Replace upper deck port side ring bouy.
Condition: Unknown
Due 2 July 1995
Resolved 2 July 1995
Lifesaving
Issued 15 May 1995 Resolved
Provide 60' painter & stencil vessel's name on upper deck stbd side ring bouy. (Current painter is only 45')
Condition: Unknown
Due 2 July 1995
Resolved 2 July 1995
Fire Fighting
Issued 15 May 1995 Resolved
Stencil vsl. name on fire axe.
Condition: Unknown
Due 2 July 1995
Resolved 2 July 1995
Electrical
Issued 15 May 1995 Resolved
Prove proper operation of frequency meter for generators.
Condition: Unknown
Due 2 July 1995
Resolved 2 July 1995
Engineering
Issued 15 May 1995 Resolved
Repair & prove proper operation of fuel oil shut off valve.
Condition: Unknown
Due 2 July 1995
Resolved 2 July 1995
Fire Fighting
Issued 15 May 1995 Resolved
Replace horn/nozzle on BII fire ext. in E/R.
Condition: Unknown
Due 2 July 1995
Resolved 2 July 1995
Lifesaving
Issued 15 May 1995 Resolved
Wash all foam type PFD's to remove excessive amount of mold, mildew & paintchips.
Condition: Unknown
Due 2 July 1995
Resolved 2 July 1995
Fire Fighting
Issued 26 May 1994 Resolved
PROVE FIRE PUMP IS CAPABLE OF SUPPLYING 50 GALLONS PER MIN AT 60 PSI AS REQUIRED BY 46 CFR 181.10.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Lifesaving
Issued 26 May 1994 Resolved
MAKE VESSEL AVIALABLE FOR UNDERWAY MANOVERBOARD, FIRE AND SENIOR DECKHAND MANUVERING DRILLS.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Documentation
Issued 26 May 1994 Resolved
SUBMIT WRITTEN PROOF OF A CHEMICAL TESTING PROGRAM WHICH COMPLIES WITH 46 CFR PART 16 TO MSO MIAMI.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Electrical
Issued 26 May 1994 Resolved
PROVIDE A SEPERATE CIRCUIT FUSED AT THE DISTRIBUTION PANEL FOR THE RADIO ASPER 46 CFR 183.05-25.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Documentation
Issued 26 May 1994 Resolved
POST EMERGENCY CHECKOFF LIST.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Fire Fighting
Issued 26 May 1994 Resolved
PROVIDE MARINE FIRE EXTINGUISHER BRACKETS FOR THE 4 BII EXTINGUISHERS.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Documentation
Issued 26 May 1994 Resolved
PROVIDE A COPY OF SUBCHAPTER T FOR VESSEL (46 CFR PARTS 166 TO 199).
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Construction/Loadline
Issued 26 May 1994 Resolved
CONNECT BOTH REQUIRED BILGE PUMPS TO A PIPING SYSTEM COMMEN TO ALL SPACES.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Construction/Loadline
Issued 26 May 1994 Resolved
ADJUST ALL FLUSH DECK HATCHES.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Construction/Loadline
Issued 26 May 1994 Resolved
INSTALL CHECK VALVES IN ALL BILGE SUCTION LINES AS PER 46 CFR 182.25-5 (C).
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Engineering
Issued 26 May 1994 Resolved
PROVIDE COAST GUARD APPROVED FUEL HOSE FOR MAIN ENGINES.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Construction/Loadline
Issued 6 May 1993 Resolved
AT NEXT DRYDOCKING GAUGE SHELL PLATING AND FUEL TANK PLATING FOR WASTAGE
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Navigation
Issued 6 May 1993 Resolved
PROVIDE COPY OF 46CFR SUB-CHAPTER T
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Engineering
Issued 6 May 1993 Resolved
PROVIDE NEW PRESSURE GAUGE TO FIRE MAIN
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Lifesaving
Issued 6 May 1993 Resolved
RELINE OR REPLACE STBD BRIDGE DECK LIFE RING
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Electrical
Issued 6 May 1993 Resolved
PROVIDE RUBBER MAT IN FRONT OF MN SWICTH BOARD
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Accommodation/Occupational Safety
Issued 7 May 1992 Resolved
PROPERLY HARDPIPE THE SW DISCHARGE FROM THE SW SEWAGE PUMP TO SERVICE.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Electrical
Issued 7 May 1992 Resolved
REMOVE ALL IMPROPER WIRE CABLE (LAMP CORDS).
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Fire Fighting
Issued 7 May 1992 Resolved
HYDROSTATIC TEST THE TWO B-II (CO2) FIRE EXTINGUISHERS LOCATED IN ENG ROOM.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Electrical
Issued 7 May 1992 Resolved
SUBMITE A REVISED WIRING DIAGRAGM. INDICATE WIRE SIZES/TYPE USED. INDICATE ALL BREAKERS SERVICING ALL PUMPS AND MOTORS.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Electrical
Issued 7 May 1992 Resolved
properly hardpipe the sw soppy from pump to both s/s diesel generators.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Engineering
Issued 7 May 1992 Resolved
reinstall the racor heat deflector shield; port mde.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Electrical
Issued 7 May 1992 Resolved
reinstall the starboard engine room flourescant light globe or replace entire fixture.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Construction/Loadline
Issued 7 May 1992 Resolved
PROPERLY LABEL BILGE MANIFOLD.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Navigation
Issued 7 May 1992 Resolved
PROPERLY PAINT BOTH SIDE LIGHT SCREENS FOR RUNNING LIGHTS USING MATTE BLACKFINISH.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Engineering
Issued 7 May 1992 Resolved
REINSTALL STBD MDE EXHAUST PIPE BRACKET.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Fire Fighting
Issued 7 May 1992 Resolved
PROVIDE SUITABLE MARINE BRACKET FOR FIRE EXTINGUISHER LOCATED IN PILOT HOUSE.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Accommodation/Occupational Safety
Issued 7 May 1992 Resolved
PROVIDE AND POST GARBAGE PLACARD.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Accommodation/Occupational Safety
Issued 7 May 1992 Resolved
PROVIDE A WRITTEN WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Engineering
Issued 7 May 1992 Resolved
PROVIDE AND INSTALL SUITABLE BELT GUARDS FOR EACH D. GEN.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Engineering
Issued 7 May 1992 Resolved
REPLACE FLACE SCREEN FOR FUEL TANK WITH 30 X 30 MESH METAL SCREEN.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Navigation
Issued 7 May 1992 Resolved
PROVIDE NAVIGATION RULES OF THE ROAD, TIDE TABLES, AND CHARTS FOR AREA OF OPERATION.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Construction/Loadline
Issued 13 May 1987 Resolved
RENEW 2 GOOSENECK VENTS TO WATER TANK COMPARTMENT, PORT AND STARBOARD SIDES
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Construction/Loadline
Issued 13 May 1987 Resolved
CROP OUT AND RENEW APPROXIMATELY 8"X18" SECTION OF DECK PLATE AT STARBOARD SIDE OF ENGINEROOM HATCH.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Engineering
Issued 13 May 1987 Resolved
RENEW SECTION OF FUEL TANK VENT PIPING BELOW MAIN DECK IN FUEL TANK SPACE.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Construction/Loadline
Issued 13 May 1987 Resolved
RENEW SCUPPER DRAIN PIPING IN WATER TANK COMPARTMENT, PORT SIDE, FORWARD.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987

Casualty record · 1

17 April 2012Routine · role: Involved in a Marine Casualty · activity 4289520
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.