← All vessels
JUNGLE QUEEN IV
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named JUNGLE QUEEN IV
JUNGLE QUEEN IV is a 1971 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1985, most recently in August 2026, along with 211 deficiencies, 1 operational control and 1 casualty investigation in 2012.
Records from 1985 to 2026. Most recent: inspection, 11 August 2026.
- Built
- 1971
- Last inspected
- 11 August 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 211 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2012
Identity
533098
WDI9827
46913
Flag
UNITED STATES
367752540
Maury page id
psix-46913
Inspections, by type
…with no type recorded9
Years with a record
39 calendar years (1985–2026)
The 81 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)78.0 ft × 26.5 ft × 7.1 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHALTER MARINE SERVICES INC · NEW ORLEANS, LA, UNITED STATES · built 1971
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI9827MMSI 367752540 · active · voluntarily equipped · granted 26 August 2016, expires 26 August 2026
WDC9889MMSI 367107980 · expired · compulsorily equipped · granted 19 April 2006, cancelled 25 June 2016
WTY9126MMSI not assigned · expired · compulsorily equipped · granted 23 January 1996, cancelled 3 June 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 81
11 August 2026
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8461829
13 January 2026
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8295401
15 October 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8253162
22 January 2025
Administrative Inspection · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8067299
1 February 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7858747
29 September 2023
Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7806882
10 May 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7685450
8 November 2022
Internal Structural Exam · Administrative Inspection · Examination of Repairs · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7579443
1 December 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7360008
13 October 2021
Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7331904
16 February 2021
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7141401
10 February 2020
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6904919
23 October 2019
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6851409
26 August 2019
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6794797
25 February 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6629722
7 December 2017
COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6310584
3 October 2017
Spot Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6280264
21 November 2016
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6044935
2 May 2016
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5867574
17 November 2015
DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5765750
10 November 2015
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5760870
15 September 2015
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5720217
7 August 2014
In-Service Inspection · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4959589
4 January 2012
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4218021
7 September 2011
Hull Examination · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4137782
13 September 2010
MTSA Verification · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3846695
21 January 2010
Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3666851
18 July 2008
MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3271603
27 February 2008
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3154630
7 November 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3093252
11 September 2007
Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3051656
18 September 2006
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2779150
15 November 2005
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2534838
2 September 2005
Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2486441
2 November 2004
Damage Survey · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2234544
20 October 2004
Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2224007
11 May 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2065092
12 March 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2023407
28 April 2003
COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1781828
17 November 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1708772
10 June 2002
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1628598
23 May 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1619896
18 April 2002
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1606028
1 May 2001
Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1422053
11 May 2000
Deficiency Check · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1417055
28 April 2000
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1427817
25 August 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 779963
11 May 1999
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 795446
29 April 1999
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1404742
26 April 1999
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1457641
30 April 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 790052
20 April 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1123440
31 October 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 31003
29 October 1997
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1110800
12 May 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1094888
29 April 1996
COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1085942
10 October 1995
Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 878707
30 June 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1190597
15 May 1995
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1234538
4 February 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 159084
25 November 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 108337
1 October 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 16516
12 August 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 864035
26 May 1994
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1170604
24 November 1993
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1161661
29 May 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1149128
6 May 1993
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1134578
28 May 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 952471
28 May 1992
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1268232
7 May 1992
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 945343
10 April 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 943586
6 May 1991
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1310887
21 September 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1222364
9 May 1990
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1240903
19 September 1989
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1197678
9 May 1989
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1340033
10 May 1988
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1345453
13 May 1987
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1324220
17 November 1986
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1010511
13 May 1986
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1299630
17 May 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 984356
Deficiency record · 211
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 13 January 2026
Resolved
All vessels shall be provided with bilge pumps IAW Table 182.25-10(a).
Replace check valve for engine room bilge suction.
46CFR182.25-10
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 January 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Charts of large enough scale to make safe navigation possible.
Paper charts must be ENC-Derived Paper Charts. If Electronic chart plotter is utilized, it must be 7.8" X 7.8" display. CG NVIC 01-16-Ch-3 guidance to be forwarded for clarification.
46 CFR 184.420(a)(1)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 January 2026
Resolved
Suitable storm rails or hand grabs shall be installed where necessary in all passageways, at deckhouse sides, and at ladders and hatches where passengers or crew might have normal access.
Repair stanchions identified during inspection and previous DD/ISE.
46CFR177.35-5
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 January 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection ....
Rusted holes were found in engine room bilge, rust holes through the fire hose stanchion on the third deck and a temporary repair on the the starboard side generator exhaust line in the lazerette.
46 CFR 177.100 16c
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 January 2025
Resolved
The pump outlet must be fitted with a pressure gauge.
Vessel Fire pump gauge was inoperable
46 CFR 181.300(b)
16c
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2025
Resolved
Each battery must be ...secured to protect against shifting with the roll and pitch of the vessel...
Multiple batteries were found without a secured tops.
46 CFR 183.350(b)
16c
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 January 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazard...
Multiple open ended wires were found throughout the engine room.
46 CFR 183.200(b)
16c
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 November 2022
Resolved
The inspection shall be such as to insure that the arrangement, materials and scantlings of the structure , piping, main and aux machinery... comply with the regulations in this sub chapter. During vessels material inspection, MIs identified the following items;
1. Excessive wastage in top plate of fuel tank and aft bulkhead of compartment. Clean area to bear metal and take gauging measurements to asses condition.
2. Fuel tank pick up pipe is severely wasted. Clean to bear metal for inspection and preserve.
3. Two holes near PORT side deck drain in fuel tank compartment and one near deck drain STBD side in fore peak. Make proper repairs.
46 CFR 176.05-5(c)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 November 2022
Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. Steering gear system is misaligned causing contact in STBD rudder post. Complete proper repairs.
46 CFR 182.30-1
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 November 2022
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. MIs identified two of the lifebuoys on board were not serviceable. Replace with serviceable life buoys.
46 CFR 117.70 (a)(3)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 February 2021
Resolved
Vessel failed to carry out satisfactory bilge pump test of fuel tank compartment. Vessel must conduct satisfactory test of the bilge pump test from fuel tank compartment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 February 2021
Resolved
Incorrect size life buoy for vessel's route of service. Provide three 24" ring buoys and place them into proper service.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 February 2021
Resolved
Vessel missing one 10BC portable fire extinguisher on 2nd deck concession stand. Install 10bc portable fire extinguisher.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2021
Resolved
Install metal support brackets for electrical wires on 2nd deck.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 February 2021
Resolved
Replace broken portable fire extinguisher bracket located on main deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2019
Resolved
Vessel has 100 type II lifejackets onboard.Vessel required to have Type I per Subchapter Q specs.
Construction/Loadline › Penetrations › Valve Flange
Issued 7 December 2017
Resolved
Shutoff Valves for generator not installed
Engineering › Steering Gear System › Rudder Stock
Issued 7 December 2017
Resolved
Gusset missing for rudder post / top
Construction/Loadline › Hull › Bottom Plating
Issued 12 October 2017
Resolved
Vessel to submit repair proposal for all wasted areas indicated.
Engineering › Thrusters › Shaft
Issued 2 May 2016
Resolved
Provide shaft alignment report (and port prop servicing and vibration report).
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 17 November 2015
Resolved
Repair inoperative port side running light.
Navigation › Piloting/Steering › Marine Charts
Issued 17 November 2015
Resolved
Provide updated charts and publications.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 November 2015
Resolved
Provide serviceable port and starboard upper deck life rings.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 17 November 2015
Resolved
Provide verification (size) of hydrostatic test on air receiver under pilothouse.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 November 2015
Resolved
Renew all childrens' PFDs with SOLAS approved retroflective tape.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 November 2015
Resolved
Provide PFD quantities are indicated where PFDs are stowed.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 November 2015
Resolved
Provide operable overhead lighting in engine room.
Engineering › Bilge Water Management System › Hose
Issued 17 November 2015
Resolved
Repair main deck line bilge suction and renew hose.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 November 2015
Resolved
Provide cover for exposed bow thruster electrical contactor.
Fire Fighting › Combustible Materials › Insulation
Issued 10 November 2015
Resolved
Install starboard side insulation and fuel oil shut-off valve insulation in engine room.
Construction/Loadline › Hull › Bottom Plating
Issued 15 September 2015
Resolved
Hole in hull under starboard generator.
Construction/Loadline › Hull › Bottom Plating
Issued 15 September 2015
Resolved
Hole in hull in starboard forepeak, just forward of collision bulkhead.
Construction/Loadline › Hull › Side Shell
Issued 15 September 2015
Resolved
Holes in sideshell on starboard side behind rubrail in rope hold (#2 void).
Construction/Loadline › Hull › Side Shell
Issued 15 September 2015
Resolved
Hole in sideshell starboard side lazarette just aft of bulkhead.
Construction/Loadline › Hull › Bottom Plating
Issued 15 September 2015
Resolved
Hole in hull starboard side of keel forward of fuel tank.
Construction/Loadline › Structures › Deck Plating
Issued 15 September 2015
Resolved
Holes in overhead on port side in fuel tank space.
Construction/Loadline › Structures › Deck Plating
Issued 15 September 2015
Resolved
Plugged thru-hull in deck (former vent) with rag stuffed in it. Properly remove deck penetration.
Construction/Loadline › Hull › Bottom Plating
Issued 15 September 2015
Resolved
Descale and gauge hull plating under port shaft seal in engine room.
Construction/Loadline › Hull › Side Shell
Issued 15 September 2015
Resolved
Gauge side shell behind starboard rub rail from stem to stern.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 15 September 2015
Resolved
Gauge marked section of fuel tank.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 15 September 2015
Resolved
Renew port and starboard shaft log and strut cutlass bearings.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 September 2015
Resolved
Remove extension cords powering fans on second deck. Install proper/permanent wiring installation.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 7 August 2014
Resolved
Provide repair proposal for wasted e/r stbd side shell IWO stbd deck drain piping and under stbd main deck ventilation duct by next avail dry dock in Sept14.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 7 August 2014
Resolved
Crop and renew wasted e/r steel on stbd side shell as identified.
Construction/Loadline › Structures › Deck Plating
Issued 7 August 2014
Resolved
Make stbd side m/d IWO vent duct available for insp.
Stability › Incline Test › General
Issued 4 January 2012
Resolved
In accordance with CG-543 Policy Letter 11-03 (Dated April 8, 2011), submit certification information to Sector Miami OCMI, with a copy to the MSC, certifying compliance with the new Final Rule regarding Assumed Average Weight Per Person (AAWPP) of 185 lbs. MSC will review and verify the information provided and issue an addendum to the existing stability letter or a new stability letter.
Fire Fighting › Fire Main › Material
Issued 13 September 2011
Resolved
Hard pipe fire main pipe where flex hose is installed.
Engineering › Bilge Water Management System › Piping
Issued 13 September 2011
Resolved
Hard pipe bilge piping where flex hose is installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 September 2011
Resolved
Provide cover over battery start connections on stanchion inboard of stbd MDE.
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2011
Resolved
Provide UT shots of Engine Room hull where identified.
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2011
Resolved
C/Renew bottom plate engine room, starboard side outboard of MDE.
Construction/Loadline › Hull › Side Shell
Issued 7 September 2011
Resolved
Crop/renew to good metal and renew as original STBD side shell hull where holed.
Construction/Loadline › Structures › Deck Plating
Issued 7 September 2011
Resolved
Scale back and make available for USCG inspection both Port & STBD side main deck outboard of bulwark where identified by USCG.
Construction/Loadline › Hull › Stiffener
Issued 7 September 2011
Resolved
Crop to good metal and renew as original deck stantion tubes where wasted at base as identified Port & STBD main deck and FWD on 2nd deck.
Construction/Loadline › Structures › Ventilators
Issued 7 September 2011
Resolved
Crop and renew as original Port & STBD vent cowling and vent frame.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2011
Resolved
Remove wasted external light fixture cover, AFT in line with 2nd deck.
Construction/Loadline › Structures › Deck Plating
Issued 7 September 2011
Resolved
Scale back flange of overhead on 2nd deck where decorative work is attached and make available for USCG inspection.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2011
Resolved
Make all exterior light fixtures water tight.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 September 2011
Resolved
Remove dead end wire fwd and inboard of STBD MDE attached to overhead in engine room.
Fire Fighting › Fire Main › Condition
Issued 7 September 2011
Resolved
Service fire main piping at FWD engine room bulkhead and lower elbow.
Engineering › Bilge Water Management System › Piping
Issued 7 September 2011
Resolved
Service bilge line discharge side of STBD bilge pump and fittings.
Fire Fighting › Fire Main › Condition
Issued 7 September 2011
Resolved
Service fittings on discharge side of fire pump raw water strainer and replace wasted metal pipe at approx 1 foot away from discharge side of strainer.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 September 2011
Resolved
Degrease engine room and scale hull under fire pump raw water strainer, under STBD shaft and throughout E/R as needed.
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 7 September 2011
Resolved
Service fittings @ heat exchanger STBD engine room side shell.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 September 2011
Resolved
Relocate electrical cable run for head raw water pump outboard of STBD MDE.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 7 September 2011
Resolved
Crop to good metal both Port & STBD stern tube inboard leading edges and repair as original.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 September 2011
Resolved
Clean/degrease both Port & STBD SSDG & MDE.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 September 2011
Resolved
Make proper repairs to Port MDE exhaust pipe where cracked in way of lagging & raw water cooling Port outboard side of pipe.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 September 2011
Resolved
Make repairs to Port MDE exhaust fiberglass baffle.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 September 2011
Resolved
Replace Port MDE raw water cooling pipe outboard IWO overhead.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 September 2011
Resolved
Replace STBD MDE raw water hose of exhaust cooling and ENG cooling hose outboard side as marked in orange with approved J1942 hose.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2011
Resolved
Provide cover for light fixture aft engine room and a cage for light fixture just STBD & FWD of aft eng room light.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 7 September 2011
Resolved
Crop & renew piping @ fuel tank & have a marine chemist certify the space prior to conducting hot work.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 September 2011
Resolved
Scale and gouge and reweld cap on Port Main engine & generator exhaust piping @ through Hull in Lazarette.
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 September 2011
Resolved
Crop/renew to good metal longitudinal stringer #2 & #3 outboard of center vertical keel STBD side in Lazarette.
Engineering › Steering Gear System › Bracket/Clamp
Issued 7 September 2011
Resolved
Crop/renew to good metal STBD steering gear support bracket in Lazarette.
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 September 2011
Resolved
Crop/renew STBD side shell longitudinal #1 & #2 IWO FWD bulkhead in Lazarette.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 September 2011
Resolved
Crop/renew hand rails @ base in AFT & FWD stairs on Deck 2 leading up to Deck 3.
Electrical › Electric Supply System (service) › Cable
Issued 13 September 2010
Resolved
Remove dead wire or properly terminate in junction box. Wire found on top of house stbd side.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 September 2010
Resolved
Remove or renew rotten fancy wood work from upper deck over pilot house.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 September 2010
Resolved
Replace grab line on stbd ring buoy on house deck and replace battery in floating water light.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 September 2010
Resolved
Renew both wasted upper stacks and ensure deck IWO stacks are sound.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 September 2010
Resolved
Provide guard over belt on stbd generator.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 13 September 2010
Resolved
Remove or properly terminate dead end wire over tool box in engine room.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 September 2010
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 September 2010
Resolved
Provide updated list from consortium showing all members enrolled in consortium for company (Jungle Queen). Five employees missing from list.
Fire Fighting › Fire Pumps › Pressure
Issued 18 July 2008
Resolved
Provide a pressure gauge for fire pump on the discharge side to prove system operates 50 GPM at 60 PSI.
Documentation › Certificates/Documents › FCC SSL
Issued 18 July 2008
Resolved
Provide vessel bridge to bridge radiotelephone certificate IAW 33 CFR 26.03.
Fire Fighting › Fire Hoses › Condition
Issued 7 November 2007
Resolved
Replace wasted fire hose on third deck.
Construction/Loadline › Hull › Hull Plating
Issued 11 September 2007
Resolved
Repair steel plating that is wasted in area of port decking void #1.
Construction/Loadline › Hull › Longitudinal Frame
Issued 11 September 2007
Resolved
Replace wasted frame stbd of keel in void #1.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 11 September 2007
Resolved
provide structural fire protection plan as closed boat or remove viser roll down panels.
Construction/Loadline › Structures › Deck Plating
Issued 11 September 2007
Resolved
Crop and renew five areas of overhead decking and crop and renew three longitudinal frames in void #2.
Construction/Loadline › Penetrations › Pipe Flange
Issued 11 September 2007
Resolved
Crop and repair stbd deck drain overboard piping in void #4.
Fire Fighting › Fire Main › Condition
Issued 11 September 2007
Resolved
Properly secure potable water pump and piping and secure firemain piping fwd engine room.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 11 September 2007
Resolved
Prove proper operation of sewage level alarm.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 September 2007
Resolved
Remove dead ended wires in void #5.
Construction/Loadline › Hull › Hull Plating
Issued 11 September 2007
Resolved
Clad weld two areas of the stbd hull. (Pits)
Construction/Loadline › Hull › Bottom Plating
Issued 11 September 2007
Resolved
Make proper repairs to wasted areas IWO sewage tank and test in presence of marine inspector.
Construction/Loadline › Hull › Keel
Issued 11 September 2007
Resolved
Air test keel in presence of marine inspector
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 11 September 2007
Resolved
Install draft marks or loading line fore and aft at 4 ft 1 inch as per requirement of vessel's stability letter.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 18 September 2006
Resolved
Install proper drip shield and protective matting in front of switchboard.
Engineering › Bilge Water Management System › Piping
Issued 18 September 2006
Resolved
Properly mount bilge piping in #2 hold.
Engineering › Fuel Oil Service System › Valve
Issued 18 September 2006
Resolved
Provide proper spanner for Emergency F/O supply valve deck cover.
Engineering › Pressure Vessel › Relief Valve
Issued 18 September 2006
Resolved
Replace compressed air safety relief valve in engine room.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 16 November 2005
Resolved
Present 543 adult and 55 child size life jackets for inspection.
Engineering › Bilge Water Management System › Pump
Issued 16 November 2005
Resolved
Prove proper operation of Bilge de-watering pumps.
Construction/Loadline › Structures › Superstructure
Issued 16 November 2005
Resolved
Make proper repairs to portside smoke stack.
Engineering › Fuel Oil Service System › Valve
Issued 16 November 2005
Resolved
Remove all plastic pet cocks from all Racor filters.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 November 2005
Resolved
Provide current Coast Pilot and Light List.
Communications › Radio Communications › VHF Radiotelephone
Issued 16 November 2005
Resolved
Fill out Emergency Broadcast Placard.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 November 2005
Resolved
Make proper electrical repairs to pilot house top lights, spot light, shore tie connection, pilot house junction box, and 110vac outlets.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 16 November 2005
Resolved
Post vessel's current Station Bill.
Electrical › Lighting (service) › Outlet Box
Issued 16 November 2005
Resolved
Remove power strip form pilot house.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 16 November 2005
Resolved
Provide complete First Aid Kit.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 16 November 2005
Resolved
Provide complete First Aid Kit.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 November 2005
Resolved
Replace all missing and broken fluorescent light covers.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 16 November 2005
Resolved
Properly mount ring life buoy water light bracket.
Engineering › Bilge Water Management System › Pump
Issued 16 November 2005
Resolved
Properly mount both bilge pumps in engine room.
Engineering › Bilge Water Management System › Interface Detector
Issued 16 November 2005
Resolved
Properly mount high water level alarm in engine room.
Electrical › Electric Supply System (service) › Cable
Issued 16 November 2005
Resolved
Remove or properly wire electrical bilge pump in engine room
Engineering › Bilge Water Management System › Interface Detector
Issued 16 November 2005
Resolved
Provide visual indicators for all high water alarms at the operating station.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 November 2005
Resolved
Secure battery box covers in engine room and bow thruster room.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 November 2005
Resolved
Replace electrical junction box cover on bow thruster motor.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 16 November 2005
Resolved
Properly mount water temperature gauge on port main diesel engine.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 November 2005
Resolved
Remove power strip from bridge.
Communications › Radio Communications › VHF Radiotelephone
Issued 16 November 2005
Resolved
Properly mount vhf, am/fm, and PA radios on bridge.
Construction/Loadline › Hull › Hull Plating
Issued 2 September 2005
Resolved
Crop to good metal and insert new plate IWO starboard forward void.
Engineering › Steering Gear System › Rudder
Issued 2 September 2005
Resolved
Grind out and re-weld crack in rudder.
Construction/Loadline › Penetrations › Pipe Flange
Issued 2 September 2005
Resolved
Crop out deck drain pipe IWO bow thruster room port side and replace as new.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 September 2005
Resolved
Install covers on light fixtures throughout the vessel.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 2 September 2005
Resolved
replace exhaust flexible hose starboard side aft.
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 September 2005
Resolved
Properly mark emergency fuel shut off.
Construction/Loadline › Hull › Hull Plating
Issued 2 September 2005
Resolved
Crop to good metal and repair hole in bottom plate IWO aft starboard side sewage tank.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 2 November 2004
Resolved
Make permanent repairs to cracks on both rudders prior to carrying passengers.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 20 October 2004
Resolved
Provide new Navigation Rules, Tide Tables and Light List
Operations/Management › Drills/Instruction › Fire
Issued 20 October 2004
Resolved
Post Station Bill at operating station.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 20 October 2004
Resolved
Provide compass deviation table.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 October 2004
Resolved
Update 1st aid kit.
Lifesaving › Lifebuoys
Issued 18 April 2002
Resolved
Install 60ft of buoyant, U/V resistant line on ring life buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Lifesaving › Lifejacket/PFD (General)
Issued 18 April 2002
Resolved
Provide 21 additional adult PFD's and until such time, total persons allowed is reduced to 522. LEGACY COMPONENT DESC: Condition
Engineering › Bilge Water Management System
Issued 18 April 2002
Resolved
Permanently install bilge pump with proper wiring and connections. LEGACY COMPONENT DESC: Pump
Engineering › Bilge Water Management System
Issued 18 April 2002
Resolved
Permanently mount bilge pumps to base. LEGACY COMPONENT DESC: Pump
Engineering › Bilge Water Management System
Issued 18 April 2002
Resolved
Install check valves in all bilge suction lines. LEGACY COMPONENT DESC: Piping
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 18 April 2002
Resolved
Provide fire extinguisher servicing report. LEGACY COMPONENT DESC: Service
Unknown
Issued 28 April 2000
Resolved
REMOVE ALL FLAMMABLES FROM ENGINE ROOM AND PROVIDE SUITABLE STORAGE.
Lifesaving
Issued 28 April 2000
Resolved
PROVIDE RETROREFLECTIVE TAPE ON ALL RING BUOYS.
Electrical
Issued 28 April 2000
Resolved
PROVIDE BLANK PLATES ON ELECTRICAL PANELS LOCATED AT ENTRANCE TO ENGINE ROOM.
Electrical
Issued 28 April 2000
Resolved
PROVIDE FLOURESCENT LIGHT COVERS FOR THE FOLLOWING LIGHTS: MAIN DECK, PORTSIDE AFT AND ENGINE ROOM.
Fire Fighting
Issued 28 April 2000
Resolved
REPLACE 01 AND 02 DECK FIRE HOSES PRIOR TO OPERATING.
Fire Fighting
Issued 28 April 2000
Resolved
REPLACE FIRE PUMP PRESSURE SWITCH AND PROVE PROPER OPERATION OF FIRE PUMP TO SATISFACTION OF USCG INSPECTORS.
Documentation
Issued 28 April 2000
Resolved
PROPERLY LOG REQUIRED CREW TRAINING AND DRILLS IAW 46 CFR 185.25.
Documentation
Issued 28 April 2000
Resolved
PROVIDE CPR CERTIFICATION FOR AT LEAST 50% OF THE CREW.
Unknown
Issued 28 April 2000
Resolved
PROVIDE APPROVED WIRE HANGERS IN ENGINE ROOM.
Unknown
Issued 28 April 2000
Resolved
PROVIDE MACHINERY GUARDS ON THE PORT GENERATOR.
Construction/Loadline
Issued 28 April 2000
Resolved
REPLACE BILGE MANIFOLD HASE ON UPPER CONNECTION TRANSFER PIPE.
Fire Fighting
Issued 28 April 2000
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVE PROPER OPERATION OF FIRE PUMP FROM EITHER SOURCE OF POWER (PORT AND STARBOARD GENERAOTR).
Engineering
Issued 28 April 2000
Resolved
REPLACE PORT GENERATOR AIR INTAKE HOSE.
Fire Fighting
Issued 28 April 2000
Resolved
REPLACE FIRE PUMP PRESSURE GAUGE.
Documentation
Issued 29 April 1999
Resolved
Correct drug testing procedure.
Lifesaving
Issued 29 April 1999
Resolved
Provide visual indicator light of high bilge level alarm for two aft compts.
Engineering
Issued 20 April 1998
Resolved
PROVIDE RUN-OUT READINGS ON BOTH PROP SHAFTS IN ENGINEROOM.
Construction/Loadline
Issued 29 April 1996
Resolved
PROVE COMPLIANCE OF BILGE SYSTEM TO PUMP 50 GPM
Unknown
Issued 29 April 1996
Resolved
COMPLY WITH DRUG TESTING PROGRAM.
Electrical
Issued 10 October 1995
Resolved
Make proper electrical connection at junction box forward starboard quarter.
Construction/Loadline
Issued 10 October 1995
Resolved
Correct small leaks on 2 welded inserts as identified.
Electrical
Issued 15 May 1995
Resolved
Prove proper operation of emergency lighting system. _x001C_ _Vessel operations are restricted to daylight hrs. only until corrected.
Fire Fighting
Issued 15 May 1995
Resolved
Prove proper operation of fixed fire pump & system to 50 gpm at 60 psi.
Lifesaving
Issued 15 May 1995
Resolved
Replace upper deck port side ring bouy.
Lifesaving
Issued 15 May 1995
Resolved
Provide 60' painter & stencil vessel's name on upper deck stbd side ring bouy. (Current painter is only 45')
Fire Fighting
Issued 15 May 1995
Resolved
Stencil vsl. name on fire axe.
Electrical
Issued 15 May 1995
Resolved
Prove proper operation of frequency meter for generators.
Engineering
Issued 15 May 1995
Resolved
Repair & prove proper operation of fuel oil shut off valve.
Fire Fighting
Issued 15 May 1995
Resolved
Replace horn/nozzle on BII fire ext. in E/R.
Lifesaving
Issued 15 May 1995
Resolved
Wash all foam type PFD's to remove excessive amount of mold, mildew & paintchips.
Fire Fighting
Issued 26 May 1994
Resolved
PROVE FIRE PUMP IS CAPABLE OF SUPPLYING 50 GALLONS PER MIN AT 60 PSI AS REQUIRED BY 46 CFR 181.10.
Lifesaving
Issued 26 May 1994
Resolved
MAKE VESSEL AVIALABLE FOR UNDERWAY MANOVERBOARD, FIRE AND SENIOR DECKHAND MANUVERING DRILLS.
Documentation
Issued 26 May 1994
Resolved
SUBMIT WRITTEN PROOF OF A CHEMICAL TESTING PROGRAM WHICH COMPLIES WITH 46 CFR PART 16 TO MSO MIAMI.
Electrical
Issued 26 May 1994
Resolved
PROVIDE A SEPERATE CIRCUIT FUSED AT THE DISTRIBUTION PANEL FOR THE RADIO ASPER 46 CFR 183.05-25.
Documentation
Issued 26 May 1994
Resolved
POST EMERGENCY CHECKOFF LIST.
Fire Fighting
Issued 26 May 1994
Resolved
PROVIDE MARINE FIRE EXTINGUISHER BRACKETS FOR THE 4 BII EXTINGUISHERS.
Documentation
Issued 26 May 1994
Resolved
PROVIDE A COPY OF SUBCHAPTER T FOR VESSEL (46 CFR PARTS 166 TO 199).
Construction/Loadline
Issued 26 May 1994
Resolved
CONNECT BOTH REQUIRED BILGE PUMPS TO A PIPING SYSTEM COMMEN TO ALL SPACES.
Construction/Loadline
Issued 26 May 1994
Resolved
ADJUST ALL FLUSH DECK HATCHES.
Construction/Loadline
Issued 26 May 1994
Resolved
INSTALL CHECK VALVES IN ALL BILGE SUCTION LINES AS PER 46 CFR 182.25-5 (C).
Engineering
Issued 26 May 1994
Resolved
PROVIDE COAST GUARD APPROVED FUEL HOSE FOR MAIN ENGINES.
Construction/Loadline
Issued 6 May 1993
Resolved
AT NEXT DRYDOCKING GAUGE SHELL PLATING AND FUEL TANK PLATING FOR WASTAGE
Navigation
Issued 6 May 1993
Resolved
PROVIDE COPY OF 46CFR SUB-CHAPTER T
Engineering
Issued 6 May 1993
Resolved
PROVIDE NEW PRESSURE GAUGE TO FIRE MAIN
Lifesaving
Issued 6 May 1993
Resolved
RELINE OR REPLACE STBD BRIDGE DECK LIFE RING
Electrical
Issued 6 May 1993
Resolved
PROVIDE RUBBER MAT IN FRONT OF MN SWICTH BOARD
Accommodation/Occupational Safety
Issued 7 May 1992
Resolved
PROPERLY HARDPIPE THE SW DISCHARGE FROM THE SW SEWAGE PUMP TO SERVICE.
Electrical
Issued 7 May 1992
Resolved
REMOVE ALL IMPROPER WIRE CABLE (LAMP CORDS).
Fire Fighting
Issued 7 May 1992
Resolved
HYDROSTATIC TEST THE TWO B-II (CO2) FIRE EXTINGUISHERS LOCATED IN ENG ROOM.
Electrical
Issued 7 May 1992
Resolved
SUBMITE A REVISED WIRING DIAGRAGM. INDICATE WIRE SIZES/TYPE USED. INDICATE ALL BREAKERS SERVICING ALL PUMPS AND MOTORS.
Electrical
Issued 7 May 1992
Resolved
properly hardpipe the sw soppy from pump to both s/s diesel generators.
Engineering
Issued 7 May 1992
Resolved
reinstall the racor heat deflector shield; port mde.
Electrical
Issued 7 May 1992
Resolved
reinstall the starboard engine room flourescant light globe or replace entire fixture.
Construction/Loadline
Issued 7 May 1992
Resolved
PROPERLY LABEL BILGE MANIFOLD.
Navigation
Issued 7 May 1992
Resolved
PROPERLY PAINT BOTH SIDE LIGHT SCREENS FOR RUNNING LIGHTS USING MATTE BLACKFINISH.
Engineering
Issued 7 May 1992
Resolved
REINSTALL STBD MDE EXHAUST PIPE BRACKET.
Fire Fighting
Issued 7 May 1992
Resolved
PROVIDE SUITABLE MARINE BRACKET FOR FIRE EXTINGUISHER LOCATED IN PILOT HOUSE.
Accommodation/Occupational Safety
Issued 7 May 1992
Resolved
PROVIDE AND POST GARBAGE PLACARD.
Accommodation/Occupational Safety
Issued 7 May 1992
Resolved
PROVIDE A WRITTEN WASTE MANAGEMENT PLAN.
Engineering
Issued 7 May 1992
Resolved
PROVIDE AND INSTALL SUITABLE BELT GUARDS FOR EACH D. GEN.
Engineering
Issued 7 May 1992
Resolved
REPLACE FLACE SCREEN FOR FUEL TANK WITH 30 X 30 MESH METAL SCREEN.
Navigation
Issued 7 May 1992
Resolved
PROVIDE NAVIGATION RULES OF THE ROAD, TIDE TABLES, AND CHARTS FOR AREA OF OPERATION.
Construction/Loadline
Issued 13 May 1987
Resolved
RENEW 2 GOOSENECK VENTS TO WATER TANK COMPARTMENT, PORT AND STARBOARD SIDES
Construction/Loadline
Issued 13 May 1987
Resolved
CROP OUT AND RENEW APPROXIMATELY 8"X18" SECTION OF DECK PLATE AT STARBOARD SIDE OF ENGINEROOM HATCH.
Engineering
Issued 13 May 1987
Resolved
RENEW SECTION OF FUEL TANK VENT PIPING BELOW MAIN DECK IN FUEL TANK SPACE.
Construction/Loadline
Issued 13 May 1987
Resolved
RENEW SCUPPER DRAIN PIPING IN WATER TANK COMPARTMENT, PORT SIDE, FORWARD.
Casualty record · 1
17 April 2012Routine · role: Involved in a Marine Casualty · activity 4289520
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.