MAURY USCG vessel records
← All vessels

YANKEE CLIPPER

YANKEE CLIPPER is a 1971 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in May 2026, along with 20 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 1 May 2026.

Built
1971
Last inspected
1 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB8100
Flag
UNITED STATES
Maury page id
psix-46923

Documentation record

Registered dimensions (L × B × D)46.6 ft × 16.9 ft × 6.4 ft
Registered tonnagegross 41 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSOUTHERN MARINE CORP · PALATKA, FL, UNITED STATES · built 1971
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGILLS ROCK, WI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Gross Ton
27 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

1 May 2026 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8359413
13 November 2025 Vessel Attendance · Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8268336
13 June 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8158899
4 June 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7928810
7 June 2023 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7709685
13 July 2022 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7505841
17 June 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7228286
21 April 2021 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7179825
7 July 2020 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7001694
15 May 2020 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6967534
23 September 2019 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6819212
5 July 2019 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6745007
17 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6718299
14 June 2018 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6444521
16 June 2017 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6253660
4 May 2016 Hull Examination · Annual Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5886596

Deficiency record · 20

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2025 Resolved
17 adult and 8 child pfds were found in disrepair. Vessel restricted to 58 adult passengers and 0 children until new arrangements are made.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 July 2025
Resolved 21 July 2025
Resolution: Operator sent photographs of new pfds (20 child size pfds and 17 adult pfds) properly labeled and stowed on board.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 15 June 2020 Resolved
Unable to verify companies Drug and Alcohol testing Management Information System (MIS) data collection form submitted for 2019 calendrer year for Voight's Marine Services. Company required to submit the MIS form each year by March 15th. Company required to submit the 2019 MIS form to the USCG or appropriate office on or before 15 July 2020. Includes Small Passenger Vessels; Yankee Clipper, ON 533288 and Island Clipper, ON 909861
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 28 June 2021
Resolution: A new dapi audit was conducted and no defs with the program were found.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 June 2019 Resolved
Forward bulkhead in enginer room has cable penetration that is not watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 6 July 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 June 2019 Resolved
Servicing on fire extinguishers expires this month. Provide servicing report once servicing is complete.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 6 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2019 Resolved
Port engine driven aft water water pump for the water injection system on the exhaust is leaking excessively. Replace/ complete maintenance as needed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 18 September 2019
Resolution: Pump gasket replaced
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 14 June 2018 Resolved
2 adult PFD's were found to be unservicable.
Action required: 705 - Other - as specified
Resolved 27 June 2018
Resolution: 2 PFD's procured and labeled.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2018 Resolved
Renew wire for alarm system on stbd MDE.
Action required: 705 - Other - as specified
Resolved 27 June 2018
Resolution: Wire was renewed.
Engineering › Bilge Water Management System › Piping
Issued 14 June 2018 Resolved
Renew bilge piping in fuel tank room during winter lay-up.
Action required: 705 - Other - as specified
Due 1 March 2019
Resolved 17 June 2019
Engineering › Steering Gear System › Linkage
Issued 29 June 2017 Resolved
Steering system grease fittings were dry. Grease steering linkages per 46 CFR 182.600
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Accommodation/Occupational Safety › Potable Water System › General
Issued 29 June 2017 Resolved
Potable water tank vent screen covered with debris. Clean the potable water vent screen per 46 CFR 176.818
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 29 June 2017 Resolved
Three adult Type I Life Jackets were no longer in service condition. Renew 3 Type I Adult Like Jackets. Vessel restricted to carry 74 persons until corrected IAW 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 29 June 2017 Resolved
Loose debris observed in the #2 compartment. Remove, per 46 CFR 182.500
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 June 2017 Resolved
Only page one of the COI was viable to passengers. Post so all pages are viewable per 46 CFR 176.302
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 29 June 2017 Resolved
Stbd main engine voltage regulator cover missing. Locate and place cover on the voltage regulator per 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 29 June 2017 Resolved
Observed a wire was disconnected from the stbd main engine low oil pressure switch. Reconnect, and test, per 46 CFR 182.200
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 July 2016 Resolved
Battery boxes are full of old dried acid waste and require cleaning to prevent damage.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2016
Resolved 20 July 2016
Resolution: Battery boxes were cleaned out.
Electrical › Electric Supply System (service) › Cable
Issued 20 July 2016 Resolved
The electrical cable for the port alternator was found significantly chaffed and requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 29 July 2016
Resolution: Cable was replaced in kind with 14-2 marine cable.
Engineering › Fuel Oil Service System › Hose
Issued 20 July 2016 Resolved
Several fuel hoses required new chaffing protection as old protection was missing or worn.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2016
Resolution: Hoses were protected with chaffing protection consisting of old fire hose.
Electrical › Electric Supply System (service) › Cable
Issued 20 July 2016 Resolved
new alternator cable must be properly supported and provided with proper chaffing protection.
Condition: Damaged By Earlier Event
Due 29 July 2016
Resolved 29 July 2016
Resolution: New cable was properly supported and provided with chaffing protection.
Stability › Watertight Integrity › General
Issued 20 July 2016 Resolved
The aft peak and forepeak hatches have wasted hatch gasket rings that require replacement as well as new gaskets to ensure watertight integrity of both spaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 1 September 2016
Resolution: MI verified two new hatch rings were installed with new gaskets. Installation found to be watertight.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.