YANKEE CLIPPER

YANKEE CLIPPER is a 1971 passenger vessel (inspected). The Coast Guard has recorded 59 inspections since 1985, most recently in May 2026, along with 89 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 1 May 2026.

Built
1971
Last inspected
1 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB8100
Flag
UNITED STATES
366952980
Maury page id
psix-46923

Inspections, by type

…with no type recorded2
Years with a record 37 calendar years (1985–2026)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.6 ft × 16.9 ft × 6.4 ft
Registered tonnagegross 41 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSOUTHERN MARINE CORP · PALATKA, FL, UNITED STATES · built 1971
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGILLS ROCK, WI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Gross Ton
27 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB8100MMSI 366952980 · active · compulsorily equipped · granted 30 May 2024, expires 29 May 2034
WZP9681MMSI not assigned · expired · compulsorily equipped · granted 2 February 1994, cancelled 16 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 59

1 May 2026 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8359413
13 November 2025 Vessel Attendance · Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8268336
13 June 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8158899
4 June 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7928810
7 June 2023 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7709685
13 July 2022 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7505841
17 June 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7228286
21 April 2021 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7179825
7 July 2020 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7001694
15 May 2020 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6967534
23 September 2019 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6819212
5 July 2019 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6745007
17 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6718299
14 June 2018 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6444521
16 June 2017 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6253660
4 May 2016 Hull Examination · Annual Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5886596
20 June 2012 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4347861
16 May 2012 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4315042
4 August 2011 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4105150
8 July 2008 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3261819
4 June 2007 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2945050
14 April 2006 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2624911
12 April 2006 Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2623045
21 September 2005 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2497951
11 April 2005 COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2331579
1 June 2004 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2709582
3 July 2003 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1833752
28 June 2002 Periodic Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1672040
15 July 2001 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1072736
29 June 2001 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1393711
13 April 2001 Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1366273
14 June 2000 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 821659
2 August 1999 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 776716
2 July 1999 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1445485
2 July 1998 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1129121
11 July 1997 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 778713
20 June 1997 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1113388
1 July 1996 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1089268
6 June 1996 Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 874318
27 June 1995 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 878718
20 September 1994 Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 869495
2 August 1994 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 866161
23 June 1994 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1024087
4 August 1993 Deficiency Check
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 843495
9 July 1993 Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1154362
11 June 1992 Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 956085
21 June 1991 COI Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 935742
17 June 1991 Hull Examination
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1198780
3 July 1990 Deficiency Check
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1228997
5 May 1990 Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 907830
24 May 1989 Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1036741
13 June 1988 COI Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1202186
18 June 1987 Type not recorded
No type recorded · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1001991
4 June 1987 Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1028484
3 June 1986 Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 991133
15 May 1986 Credit Drydock
Administrative · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1304422
9 September 1985 Deficiency Check
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1298059
30 July 1985 Deficiency Check
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 982240
24 May 1985 Type not recorded
No type recorded · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1291434

Deficiency record · 89

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2025 Resolved
17 adult and 8 child pfds were found in disrepair. Vessel restricted to 58 adult passengers and 0 children until new arrangements are made.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 July 2025
Resolved 21 July 2025
Resolution: Operator sent photographs of new pfds (20 child size pfds and 17 adult pfds) properly labeled and stowed on board.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 15 June 2020 Resolved
Unable to verify companies Drug and Alcohol testing Management Information System (MIS) data collection form submitted for 2019 calendrer year for Voight's Marine Services. Company required to submit the MIS form each year by March 15th. Company required to submit the 2019 MIS form to the USCG or appropriate office on or before 15 July 2020. Includes Small Passenger Vessels; Yankee Clipper, ON 533288 and Island Clipper, ON 909861
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 28 June 2021
Resolution: A new dapi audit was conducted and no defs with the program were found.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 June 2019 Resolved
Forward bulkhead in enginer room has cable penetration that is not watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 6 July 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 June 2019 Resolved
Servicing on fire extinguishers expires this month. Provide servicing report once servicing is complete.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 6 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2019 Resolved
Port engine driven aft water water pump for the water injection system on the exhaust is leaking excessively. Replace/ complete maintenance as needed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 18 September 2019
Resolution: Pump gasket replaced
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 14 June 2018 Resolved
2 adult PFD's were found to be unservicable.
Action required: 705 - Other - as specified
Resolved 27 June 2018
Resolution: 2 PFD's procured and labeled.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2018 Resolved
Renew wire for alarm system on stbd MDE.
Action required: 705 - Other - as specified
Resolved 27 June 2018
Resolution: Wire was renewed.
Engineering › Bilge Water Management System › Piping
Issued 14 June 2018 Resolved
Renew bilge piping in fuel tank room during winter lay-up.
Action required: 705 - Other - as specified
Due 1 March 2019
Resolved 17 June 2019
Engineering › Steering Gear System › Linkage
Issued 29 June 2017 Resolved
Steering system grease fittings were dry. Grease steering linkages per 46 CFR 182.600
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Accommodation/Occupational Safety › Potable Water System › General
Issued 29 June 2017 Resolved
Potable water tank vent screen covered with debris. Clean the potable water vent screen per 46 CFR 176.818
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 29 June 2017 Resolved
Three adult Type I Life Jackets were no longer in service condition. Renew 3 Type I Adult Like Jackets. Vessel restricted to carry 74 persons until corrected IAW 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 29 June 2017 Resolved
Loose debris observed in the #2 compartment. Remove, per 46 CFR 182.500
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 June 2017 Resolved
Only page one of the COI was viable to passengers. Post so all pages are viewable per 46 CFR 176.302
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 29 June 2017 Resolved
Stbd main engine voltage regulator cover missing. Locate and place cover on the voltage regulator per 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 29 June 2017 Resolved
Observed a wire was disconnected from the stbd main engine low oil pressure switch. Reconnect, and test, per 46 CFR 182.200
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 6 July 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 July 2016 Resolved
Battery boxes are full of old dried acid waste and require cleaning to prevent damage.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2016
Resolved 20 July 2016
Resolution: Battery boxes were cleaned out.
Electrical › Electric Supply System (service) › Cable
Issued 20 July 2016 Resolved
The electrical cable for the port alternator was found significantly chaffed and requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 29 July 2016
Resolution: Cable was replaced in kind with 14-2 marine cable.
Engineering › Fuel Oil Service System › Hose
Issued 20 July 2016 Resolved
Several fuel hoses required new chaffing protection as old protection was missing or worn.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2016
Resolution: Hoses were protected with chaffing protection consisting of old fire hose.
Electrical › Electric Supply System (service) › Cable
Issued 20 July 2016 Resolved
new alternator cable must be properly supported and provided with proper chaffing protection.
Condition: Damaged By Earlier Event
Due 29 July 2016
Resolved 29 July 2016
Resolution: New cable was properly supported and provided with chaffing protection.
Stability › Watertight Integrity › General
Issued 20 July 2016 Resolved
The aft peak and forepeak hatches have wasted hatch gasket rings that require replacement as well as new gaskets to ensure watertight integrity of both spaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 1 September 2016
Resolution: MI verified two new hatch rings were installed with new gaskets. Installation found to be watertight.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 20 June 2012 Resolved
Prove proper operation of port main engine. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2012
Resolution: Port engine operating properly.
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 June 2012 Resolved
Conduct underway man over board & fire drills in presence of MI upon repair of port engine. 46 CFR 185.520 & .524
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2012
Resolution: Sat drills conducted.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 20 June 2012 Resolved
Provide portable lighting (flashlight) for operating station. 46 CFR 183.430
Due 27 June 2012
Resolved 26 June 2012
Resolution: Flashlight provided in operating station.
Documentation › Markings/Placards › Capacity Marking
Issued 20 June 2012 Resolved
Post correct upper deck passenger limit (20). 46 CFR 185.602(g)
Due 27 June 2012
Resolved 26 June 2012
Resolution: Upper deck passenger limit correctly marked.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 4 June 2007 Resolved
Provide proper engine mounts of suitable type and design for propulsion machinery as installed in accordance with 46 CFR 182.200. Currently the vessel has wooden blocks installed in place adequate motor mounts.
Condition: Placed in Improper Service
Due 4 July 2007
Resolved 26 June 2007
Resolution: Attended vessel and observed suitable motor mounts had been installed.
Navigation › Piloting/Steering › Magnetic Compass
Issued 5 June 2006 Resolved
Renew Compass Light and demonstrate proper illumination
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 6 June 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 June 2006 Resolved
Secure loose main deck seats as required
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2006
Resolved 6 June 2006
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 5 June 2006 Resolved
Renew both main engine foundation shims with acceptable material, realign shaft bearings as needed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 9 July 2008
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 3 May 2006 Resolved
Remove wooden motor mount shims, reline or ensure shafts are aligned, and renew motor mount shims with acceptable material (steel or chalk-fast).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 5 June 2006
Resolution: Cleared and Issue a new CG-835 allowing the vessel to operate for summer 2006, to be replaced by 01May2007
Construction/Loadline › Structures › Deck Plating
Issued 3 May 2006 Resolved
Reweld or renew wasted deck plate angle in the fwd peak.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 6 June 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 31 May 2005 Resolved
Renew Ampere on Pilot House 32 VDC electrical panel
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 July 2005
Resolved 21 September 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 May 2005 Resolved
Fix and demonstrate proper operation of vessels anchor light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 July 2005
Resolved 9 June 2005
Lifesaving › Hand Flares › Expired
Issued 31 May 2005 Resolved
Renew outdated Flares, 6 Red & 6 Orange
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2005
Resolved 9 June 2005
Engineering › Fuel Oil Service System
Issued 3 July 2003 Resolved
Fuel hose on STBD M/E is showing signs of aging/wear. Replace hose with USCG approved hose. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2003
Resolved 28 July 2003
Resolution: Replaced hose with USCg approved hose.
Electrical › Electric Generation Source (service)
Issued 3 July 2003 Resolved
Alternator/Generator on port M/E is dirty and in need of cleaning. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2003
Resolved 28 July 2003
Resolution: Cleaned alternator.
Lifesaving › Lifejacket/PFD (Type I)
Issued 3 July 2003 Resolved
11 type I jackets failed due to stiching on the seams. Replace with new approved lifejackets and mark with vessel name. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2003
Resolved 28 July 2003
Resolution: Replaced life jackets and marked with vessel name.
Lifesaving › Lifebuoys
Issued 3 July 2003 Resolved
Present light is no longer approved and needs to be replace with a current approved model. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2003
Resolved 28 July 2003
Resolution: Replaced light with an approved model.
Communications › Radio Communications
Issued 3 July 2003 Resolved
Provide emergency broadcast placard for VHF radio. LEGACY COMPONENT DESC: VHF Radiotelephone
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2003
Resolved 28 July 2003
Resolution: Provided an emergency broadcast placard for VHF radio.
Lifesaving › Lifejacket/PFD (General)
Issued 3 July 2003 Resolved
Provide donning placard for collar type PFD's.
Action required: 705 - Other - as specified
Due 28 July 2003
Resolved 28 July 2003
Resolution: Provided donning placard for collar type PFD''s.
Electrical › Lighting (emergency)
Issued 3 July 2003 Resolved
Provide portable light for engine room. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2003
Resolved 28 July 2003
Resolution: Provided portable light for engine room.
Electrical › Lighting (service) › Lighting Fixture
Issued 28 June 2002 Resolved
Repair faulty masthead light contacts at bulb.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 June 2002
Resolution: Contacts cleaned and light functioning properly.
Construction/Loadline
Issued 29 June 2001 Resolved
Secure deck hatch over steering compartment.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Documentation
Issued 29 June 2001 Resolved
Obtain and maintain training and life saving maintenance logs.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Fire Fighting
Issued 29 June 2001 Resolved
Service or replace B-I extinguisher in pilothouse.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Fire Fighting
Issued 2 July 1999 Resolved
PROVIDE ADDITIONAL HOSE CLAMP ON SUCTION SIDE OF FIRE PUMP.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Accommodation/Occupational Safety
Issued 2 July 1999 Resolved
REMARK LOCATION OF CHILDRENS PFDS.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Construction/Loadline
Issued 2 July 1999 Resolved
REPLACE BROKEN BILGE PIPING STRAINER IN FUEL ROOM.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Lifesaving
Issued 2 July 1999 Resolved
REPLACE LIFE RING LINES.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Construction/Loadline
Issued 2 July 1999 Resolved
MAKE WT BLKD PENETRATIONS WATERTIGHT.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Engineering
Issued 20 June 1997 Resolved
Provide lagging/insulation for main engine exhaust expansion joints.
Condition: Unknown
Due 20 June 1997
Resolved 20 June 1997
Engineering
Issued 20 June 1997 Resolved
Prove proper operation of starboard main engine tachometer.
Condition: Unknown
Due 20 June 1997
Resolved 20 June 1997
Accommodation/Occupational Safety
Issued 20 June 1997 Resolved
Mark the upper deck maximum passenger capacity in vicinity of access to deck.
Condition: Unknown
Due 20 June 1997
Resolved 20 June 1997
Lifesaving
Issued 20 June 1997 Resolved
Mark life preserver stowage in the forward locker with contrasting label.
Condition: Unknown
Due 20 June 1997
Resolved 20 June 1997
Engineering
Issued 20 June 1997 Resolved
Relabel fuel marking for shut-off valves in port and stbd heads to better indicate valve locations.
Condition: Unknown
Due 20 June 1997
Resolved 20 June 1997
Engineering
Issued 20 June 1997 Resolved
Renew deteriorated fuel hoses to main engine fuel filters.
Condition: Unknown
Due 20 June 1997
Resolved 20 June 1997
Accommodation/Occupational Safety
Issued 20 June 1997 Resolved
Properly secure sanitary water pump to mounting.
Condition: Unknown
Due 20 June 1997
Resolved 20 June 1997
Fire Fighting
Issued 20 June 1997 Resolved
Adjust belt tension to fire pump and prove proper operation of effective stream.
Condition: Unknown
Due 20 June 1997
Resolved 20 June 1997
Engineering
Issued 6 June 1996 Resolved
Renew starboard water lubricated strut bearing.
Condition: Unknown
Due 30 June 1996
Resolved 6 September 1996
Construction/Loadline
Issued 6 June 1996 Resolved
Install bolts were missing in sewage tank top cover.
Condition: Unknown
Due 30 June 1996
Resolved 6 September 1996
Accommodation/Occupational Safety
Issued 27 June 1995 Resolved
Toilet in Men's head not proprly operating due to lack of flushing water. Prove proper operation of toilet with adequate plumbing.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Navigation
Issued 27 June 1995 Resolved
Provide proper navigation running lights in accordance with 72 COLREGS inland rule 23(a)(i) and 23(a)(iv) masthead and stern lights or mount the all-round light aft to comply with exemption rule 38(vi).
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Lifesaving
Issued 27 June 1995 Resolved
Provide 4 additional adult lifejackets for a total of 103.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Documentation
Issued 23 June 1994 Resolved
Post the stability letter dated 22JUN71 under glass in the pilothouse as required by 46CFR185.12-1(a) prior to the compliance date.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Lifesaving
Issued 23 June 1994 Resolved
Provide 20 additional approved adult type I life preservers on board the vessel as required by 46CFR180.25-5(a) prior to the compliance date.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Documentation
Issued 23 June 1994 Resolved
Implement a pre-employment chemical testing program for seasonal employees as required by 46CFR16.210(a) prior to the compliance date.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Electrical
Issued 23 June 1994 Resolved
Remove the torn electrical wire from the old masthead light located on the forward side of the flying bridge as required by 46CFR183.05-45(e) prior tothe compliance date.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Accommodation/Occupational Safety
Issued 23 June 1994 Resolved
Resecure the bottom of the ladder located inside after steering to the transverse framing as required by 46CFR177.35-15(a) prior to the compliancedate.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Accommodation/Occupational Safety
Issued 23 June 1994 Resolved
Repair the wooden passenger seating on the after passenger deck located on the starboard side forward and athwartships aft as required by 46CFR177.30-1(a) prior to the compliance date.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Fire Fighting
Issued 23 June 1994 Resolved
Repair the broken hanger on the neck of the B-II hand portable fire extinguisher (CO2) located in the engineroom as required by 46CFR181.30- 5(a) prior to the compliance date.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Engineering
Issued 23 June 1994 Resolved
Replace the leaking gasket in the cover to the exhaust impellor on the aft side of the starboard engine as required by 46CFR182.05-1(a) prior to the compliance date.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Electrical
Issued 9 July 1993 Resolved
CLEAN BATTERY TERMINAL CONNECTIONS ON PORT AND STBD MAIN ENGINE STARTING BATTERIES.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Engineering
Issued 9 July 1993 Resolved
REPLACE MISSING SPRING ON STBD MAIN ENGINE GOVERNOR.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Electrical
Issued 9 July 1993 Resolved
REPLACE MISSING LIGHT FIXTURE AND EXPLOSION COVER IN ENGINEROOM.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Lifesaving
Issued 21 June 1991 Resolved
PROVIDE ONE ADDITIONAL TYPE I PFD.
Condition: Unknown
Due 21 June 1991
Resolved 21 June 1991
Lifesaving
Issued 21 June 1991 Resolved
STENCIL ADULT PFD QUANTITY AND TYPE ON FWD. CABIN.
Condition: Unknown
Due 21 June 1991
Resolved 21 June 1991
Documentation
Issued 21 June 1991 Resolved
RENEW RADIOTELEPHONE CERTIFICATE
Condition: Unknown
Due 21 June 1991
Resolved 21 June 1991
Unknown
Issued 5 May 1990 Resolved
PROVE OPERATION OF PRESSURE VESSEL RELIEF VALVE.
Condition: Unknown
Due 5 May 1990
Resolved 5 May 1990
Construction/Loadline
Issued 5 May 1990 Resolved
SEAL AND PROPERLY SECURE AFT VOID HATCH COVER.
Condition: Unknown
Due 5 May 1990
Resolved 5 May 1990
Construction/Loadline
Issued 5 May 1990 Resolved
CAP OFF PIPE GOING THROUGH ENGINE ROOM AFTER BULKHEAD.
Condition: Unknown
Due 5 May 1990
Resolved 5 May 1990
Engineering
Issued 5 May 1990 Resolved
REPAIR LEAK ON STBD EXHAUST DIRECTLY FORWARD OF MUFFLER.
Condition: Unknown
Due 5 May 1990
Resolved 5 May 1990
Navigation
Issued 5 May 1990 Resolved
ENSURE ALL RUNNING LIGHTS ARE IN ACCORDANCE WITH RULES OF ROAD.
Condition: Unknown
Due 5 May 1990
Resolved 5 May 1990
Lifesaving
Issued 5 May 1990 Resolved
PROVIDE DONNING INSTRUCTIONS FOR LIFEPRESERVERS AND ADDITIONAL SAFETY ORIENTATION REQUIRED BY 46 CFR 185.25.
Condition: Unknown
Due 5 May 1990
Resolved 5 May 1990
Electrical
Issued 5 May 1990 Resolved
MARK ALL CIRCUIT BREAKERS AS TO THEIR USE.
Condition: Unknown
Due 5 May 1990
Resolved 5 May 1990
Lifesaving
Issued 4 June 1987 Resolved
TOTAL PERSONS ALLOWED IS REDUCED TO 98 PERSONS UNTIL 5 ADDITIONAL ADULT PFD'S HAVE BEEN INSPECTED AND STAMPED. (9 PFD'S FOUND WASTED- 6 REPLACED ON SCENE AND STAMPED PASSED. 5 ADDITIONAL REQUIRED TO MEET COI TOTAL POB ALLOWED- 103).
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Engineering
Issued 24 May 1985 Resolved
REPAIR THE EXHAUST LEAK ON THE STBD MAIN ENGINE, INBOARD HEADER OUTLET.
Condition: Unknown
Due 24 May 1985
Resolved 24 May 1985
Electrical
Issued 24 May 1985 Resolved
REPAIR OR REPLACE THE STARTING SOLENOID FOR THE AIR COMPRESSOR.
Condition: Unknown
Due 24 May 1985
Resolved 24 May 1985
Electrical
Issued 24 May 1985 Resolved
PROVIDE A COVER FOR THE 110 VOLT SHORE TIE ELECTRICAL CONNECTIONS.
Condition: Unknown
Due 24 May 1985
Resolved 24 May 1985
Navigation
Issued 24 May 1985 Resolved
PAINT THE SIDE LIGHT SCREENS FLAT BLACK.
Condition: Unknown
Due 24 May 1985
Resolved 24 May 1985
Navigation
Issued 24 May 1985 Resolved
REPLACE THE RED LENSE IN THE PORT SIDE LIGHT.
Condition: Unknown
Due 24 May 1985
Resolved 24 May 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.