← All vessels
ORCA TOO
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named ORCA TOO
ORCA TOO is a 1997 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 1998, most recently in May 2012, along with 42 deficiencies and 1 casualty investigation in 2007.
Records from 1998 to 2012. Most recent: inspection, 22 May 2012.
- Built
- 1997
- Last inspected
- 22 May 2012
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 42 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2007
Identity
1062406
WCX9667
469322
Flag
UNITED STATES
367336770
Maury page id
psix-469322
Inspections, by type
…with no type recorded5
Years with a record
13 calendar years (1998–2012)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)41.9 ft × 15.3 ft × 8.7 ft
Registered tonnagegross 37 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBELFAST ME · BELFAST ME, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBOQUERON, PR
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 9 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Net Ton
37 - Simplified, Gross Ton
37 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDM4927MMSI 367336770 · active · voluntarily equipped · granted 20 July 2021, expires 20 July 2031
WCX9667MMSI 367336770 · expired · voluntarily equipped · granted 9 February 2008, cancelled 26 May 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 26
22 May 2012
Hull Examination · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4328627
7 May 2009
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3469613
28 April 2008
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3194989
22 April 2008
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3191306
16 July 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2997315
9 April 2007
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2909514
23 July 2006
Type not recorded
No type recorded · USCGC MATINICUS (WPB 1315) · USCG Southeast District (CGD-SE) · Activity 2799840
26 April 2006
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2637589
21 April 2006
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2626351
26 November 2005
Type not recorded
No type recorded · USCGC CUSHING (WPB 1321) · USCG Southeast District (CGD-SE) · Activity 2546707
1 June 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2376528
27 April 2005
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2339491
27 April 2004
Hull Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2058301
7 May 2003
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1789881
29 April 2002
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1611141
23 April 2002
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1611128
14 March 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1493775
24 April 2001
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1431024
9 September 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 30463
7 July 2000
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 820768
11 April 2000
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1429362
4 April 2000
Deficiency Check · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1453769
27 April 1999
Re-Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1386486
15 June 1998
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1364756
30 April 1998
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1132153
30 April 1998
Initial Construction-Excluding Oversight · Plan Review "T" Boat · Initial Certification
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1472726
Deficiency record · 42
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 May 2009
Resolved
High water bilge alarm not working properly, fix prior to taking on passengers.
Lifesaving › Lifefloat › Serviceable
Issued 7 May 2009
Resolved
Lifefloats need reconditiong and line replacement. Prior to taking on passengers.
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 May 2009
Resolved
Found (3) deck longs in w/o starboard side of engine compartment deterioated. Angel hair excess of humidity(wet rot). Replace or reinforce. If replaced, replace in kind.
Operations/Management › Pollution › Control of Garbage
Issued 28 April 2008
Resolved
Provide a Waste Management Plan as per 33 CFR 151.57 for commercial vessel with oceangoing route over 40 feet.
Navigation › Piloting/Steering › US Coast Pilot
Issued 28 April 2008
Resolved
Provide navigatioon publications for area of operation (Coast Pilot, Tide and Tidal tables, lightlist).
Construction/Loadline › Hull › Bottom Plating
Issued 27 April 2006
Resolved
Make proper repair to the hull area surrounding the rudder post, external area, where the head of the support bolt penetrates the hull.
Lifesaving › Lifefloat › Netting
Issued 27 April 2005
Resolved
Replace as original the netting to the 22 person lifefloat.
Communications › Radio Communications › EPIRB
Issued 27 April 2005
Resolved
Provide updated NOAA registration for EPIRB.
Lifesaving › Lifefloat › Platform
Issued 27 April 2005
Resolved
Provide spacers between lifefloats.
Construction/Loadline › Hull
Issued 27 April 2004
Resolved
Grind and reseal with fiber glass forward section of bow, port and starboard, below the waterline. Item to be verified prior in placing the vessel back in the water. LEGACY COMPONENT DESC: Hull Plating
Lifesaving
Issued 7 May 2003
Resolved
Replace EPIRB battery prior to carry passengers for hire.
Accommodation/Occupational Safety › Medical/First Aid
Issued 7 May 2003
Resolved
Provide Coast Guard or equivalent first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Documentation
Issued 24 April 2001
Resolved
Vessel to provide proof of FCC Communication Act Safety Radiotelephony Certificate.
Fire Fighting
Issued 4 April 2000
Resolved
DEVELOP AND POST "OPERATOR INSTRUCTIONS" FOR THE FIXED FIRE SYSTEM
Lifesaving
Issued 4 April 2000
Resolved
PROVIDE FIRST AID KIT
Fire Fighting
Issued 4 April 2000
Resolved
SERVICE FIRE EXTINGUISHERS AND FIXED SYSTEM
Accommodation/Occupational Safety
Issued 4 April 2000
Resolved
REPLACE FOREPEAK BROKEN LADDER
Lifesaving
Issued 4 April 2000
Resolved
ATTACH DARK LINE TO THE FLOAT LIGHT AND THE LIFERING
Documentation
Issued 27 April 1999
Resolved
PROVIDE EVIDENCE OF EMPLYER ASSISTANCE PROGRAM TO INCLUDE EMPLOYER'S POLICY, HOTLINE NUMBERS, AND TRAINING TOP CREW.
Documentation
Issued 27 April 1999
Resolved
PROVIDE CREW TRAINING LOG.
Electrical
Issued 27 April 1999
Resolved
PROVIDE TWO (2) PORTABLE LIGHTS.
Lifesaving
Issued 27 April 1999
Resolved
PROVIDE THREE (3) HAND HELD ORANGE SMOKE DISTRESS SIGNALS.
Fire Fighting
Issued 27 April 1999
Resolved
ATTACH LINE AND LABEL ALL FIRE BUCKETS WITH "FIRE BUCKET".
Lifesaving
Issued 15 June 1998
Resolved
PROVIDE LIFEJACKET DONNING PLACARD.
Documentation
Issued 15 June 1998
Resolved
PROVIDE EVIDENCE OF RANDOM DRUG TESTING.
Lifesaving
Issued 15 June 1998
Resolved
PROVIDE LIFE LINE ON TRANSOM DOOR.
Documentation
Issued 15 June 1998
Resolved
PROVIDE EVIDENCE OF CG PAYMENT FEE PAYMENT.
Navigation
Issued 15 June 1998
Resolved
REPAIR EMERGENCY STEERING TILLER.
Lifesaving
Issued 15 June 1998
Resolved
SEPARATE ADULT FROM CHILD LIFE PRESERVERS.
Lifesaving
Issued 15 June 1998
Resolved
LABEL LIFE FLOAT OARS WITH VESSEL NAME.
Lifesaving
Issued 15 June 1998
Resolved
CONDUCT EMERGENCY DRILLS WITH CG INSPECTORS
Electrical
Issued 15 June 1998
Resolved
PROVIDE ADDITIONAL EMERGENCY LIGHT.
Lifesaving
Issued 15 June 1998
Resolved
LABEL VESSEL NAME ON EPIRB.
Lifesaving
Issued 15 June 1998
Resolved
LABEL PFD LIFE PRESERVER CONTAINER WITH QUANTITY AND SIZE.
Lifesaving
Issued 15 June 1998
Resolved
PROVIDE 50 LBS CORROSION RESISTANT CLIP ON LIFE RING LIGHT AND PROVIDE DARKOR UV RESISTANT TIE DOWN LINE.
Lifesaving
Issued 15 June 1998
Resolved
LABEL FIRST AID KIT.
Engineering
Issued 30 April 1998
Resolved
PROVIDE BARBED FITTINGS OR PREMADE HOSE FOR FUEL LINES ON FILTER. PROVIDE TUBING/PIPE FROM TANK THRU BULKHEAD TO ENGINE ROOM.
Unknown
Issued 30 April 1998
Resolved
PROVIDE PROOF OF CHEMICASL TESTING PROGRAM.
Documentation
Issued 30 April 1998
Resolved
PROVIDE PROOF OF FCC SAFETY INSPECTION AND STATION LICENSE.
Fire Fighting
Issued 30 April 1998
Resolved
LABLE VENTILATION CLOSURES.
Unknown
Issued 30 April 1998
Resolved
PROVIDE EMERGENCY INSTRUCTIONS.
Unknown
Issued 30 April 1998
Resolved
CONDUCT NEW TO ZONE INSPECTION WITH MSO SAN JUAN.
Casualty record · 1
16 July 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2997315
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.