Documentation record
Registered dimensions (L × B × D)52.4 ft × 17.0 ft × 7.3 ft
Registered tonnagegross 44 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROSE BROTHERS BOAT WORKS · HARKERS ISLAND, NC, UNITED STATES · built 1971
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Endorsements, as the file codes themcw_un, reg
DocumentationCase Pending · issued 28 August 2024 · expires 31 August 2025
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Regulatory (Subpart C or D), Gross Ton
21 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
8 October 2024
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8016326
14 December 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7367614
8 July 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7249888
19 May 2020
COI Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6956258
20 August 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6721228
14 May 2019
Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6618651
27 August 2018
Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6524761
19 June 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6449859
9 June 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6188867
30 May 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6126778
9 May 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6126766
2 September 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5989686
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 August 2020
Resolved
Valves for removing water or impurities from diesel fuel in water traps or strainers are permitted. These valves must be provided with caps or plugs to prevent fuel leakage. Stbd MDE Racor fuel strainer bowl is missing plug/cap. Provide and install plug/cap.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2020
Resolved 11 August 2020
Resolution: Installed starboard MDE fuel strainer plug.
Communications › Radio Communications › EPIRB
Issued 30 May 2017
Resolved
Provide EPIRB with registration and operational battery. Operations limited to no more than 3 NM from shore.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 9 June 2017
Resolution: EPIRB was on board vessel with a valid registration and a new battery.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 30 May 2017
Resolved
Install flame screen (30 x 30 mesh) on port side fuel tank vent.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 9 June 2017
Resolution: Vent was identified as a vent for a water tank and not a fuel tank,not requiring a flame screen.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 May 2017
Resolved
Clean port/stbd sidelight filters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 9 June 2017
Resolution: Owner replaced port and sidelight filters with new ones.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 May 2017
Resolved
Publicly post all sheets of COI under transparent medium.
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 30 May 2017
Resolution: All sheets posted publicly.
Documentation › Certificates/Documents › Stability Letter
Issued 30 May 2017
Resolved
Post original stability letter with addendum.
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 30 May 2017
Resolution: Original stability lette rposted with addendum.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 30 May 2017
Resolved
Have emergency broadcast instructions readily available in pilot house.
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 30 May 2017
Resolution: Emergency broadcast instructions made readily available in pilot house.
Engineering › Bilge Water Management System › Pump
Issued 30 May 2017
Resolved
Permanently secure submersible electric bilge pump to bilge.
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 30 May 2017
Resolution: Bilge pump securely affixed to bilge.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 May 2017
Resolved
Complete a hull exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2017
Resolved 19 May 2017
Construction/Loadline › Structures › Manhole
Issued 9 May 2017
Resolved
Ensure emergency escape operates properly in forward stores.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 19 May 2017
Resolution: Confirmed proper operation of emergency escape hatch.
Construction/Loadline › Structures › Deck Plating
Issued 9 May 2017
Resolved
Repair, reinforce/replace deck beam of galley/overhead of engine room, stbd side.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 19 May 2017
Resolution: Confirmed deck beam repairs.
Construction/Loadline › Hull › Hull Plating
Issued 9 May 2017
Resolved
Crop, treat and renw areas of worm damage as indicated.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 19 May 2017
Resolution: Vessel re-entered the marine environment without allowing a marine inspector to verify the repairs. Inspector conducted internal structural exam and confirmed repairs were non-structral and watertight.
Construction/Loadline › Hull › Hull Plating
Issued 9 May 2017
Resolved
Replace nail fasteners as indicated.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 19 May 2017
Resolution: All fasteners were replaced with silicon bronze screws.
Construction/Loadline › Structures › Deck Plating
Issued 9 May 2017
Resolved
Replace swim step support bolt.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 19 May 2017
Resolution: Swim step bolts replaced.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 May 2017
Resolved
Scrape and treat rot as indicated in sft portion of engine room bulkhead.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 19 May 2017
Resolution: Rot was scraped and treated.
Communications › Radio Communications › Satellite Communications Capability
Issued 30 September 2016
Resolved
INSTALL A VHF-FM RADIO WITH DIGITAL SELECT CALLING (DSC), EITHER A CLASS "A" OR "D."
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 28 October 2016
Resolution: New VHF-DSC radio installed, tested by FCC, new safety radio cert issued, all satisfactory.
Communications › Radio Communications › EPIRB
Issued 2 September 2016
Resolved
Provide updated registration for EPIRB, restricted to no more than 03 miles from mainland shore.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 September 2016
Resolution: VSL provided new EPIRB Registration.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 September 2016
Resolved
Update FCC safety certificate with vessel's new call sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 28 October 2016
Resolution: New FCC safety radio certificate provided, verifying new VHF_DSC Radio operation.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 2 September 2016
Resolved
Provide valid FCC operator's permit for vessel's master.
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 30 September 2016
Resolution: Received proof of FCC Radio Operator's Permit, all satisfactory.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 2 September 2016
Resolved
Provide proof of company's written drug and alcohol testing program policy, or update as necessary; information on board not sufficient.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 28 September 2016
Resolution: VSL provided written policy for drug and alcohol testing program.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 2 September 2016
Resolved
Provide proof that all crewmembers are actively enrolled in drug & alcohol program.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 9 September 2016
Resolution: Chandler Bell of Hornblower provided list of enrolled members in drug testing program via e-mail attachment. All are listed in the program.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 2 September 2016
Resolved
Provide proof of the 2015 MIS report.
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 9 September 2016
Resolution: Chandler Bell of Hornblower provided 2015 MIS report via E-mail.