IN DUTCH II is a 1998 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 1998, most recently in May 2026, along with 13 deficiencies.

Records from 1998 to 2026. Most recent: inspection, 19 May 2026.

Built
1998
Last inspected
19 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

469372
Flag
UNITED STATES
—
Maury page id
psix-469372

Inspections, by type

Years with a record 25 calendar years (1998–2026)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)28.0 ft × 9.0 ft × 4.0 ft
Registered tonnagegross 6 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS MFG · LEWISTON ID, UNITED STATES · built 1998
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portRIGGINS, ID
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 28

19 May 2026 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8383468
13 May 2025 DAPI Audit · COI Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8140641
22 May 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7929348
23 May 2023 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7702141
20 April 2022 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7445369
19 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7226172
29 July 2020 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7019630
19 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6963609
20 May 2019 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6685715
8 May 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6402662
27 April 2017 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6133965
3 May 2016 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5863249
13 May 2014 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4854441
15 May 2012 Administrative Inspection · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4305980
11 May 2009 Annual Inspection · Administrative Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3468211
13 May 2008 Annual Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3192156
24 March 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3022302
18 April 2006 Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2621547
3 May 2005 Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2338269
28 April 2004 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2048516
30 April 2003 Annual Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1779386
26 February 2003 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1749889
1 May 2002 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1608811
1 May 2001 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1063508
3 May 2000 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1410336
15 December 1999 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 812944
21 April 1999 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 791338
15 February 1998 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification · Plan Review "T" Boat
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1110299

Deficiency record · 13

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 May 2018 Resolved
Prove proper operation of the fume/vapor detector in the machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2018
Resolution: Vessel owner replaced fume/vapor detector in the engine compartment.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2018 Resolved
Provide one (1) A-2 portable fire extinguisher for the accommodation space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2018
Resolution: Vessel owner purchased and installed new portable fire extinguisher aboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 May 2018 Resolved
Repair or replace the starboard navigation light as needed.
Action required: 705 - Other - as specified
Resolved 8 June 2018
Resolution: Vessel owner replaced the bulb for the starboard navigation light; tested satisfactorily.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2018 Resolved
Provide a manual bilge pump, with a discharge hose of adequate length to dewater the vessel in the event of an emergency.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2018
Resolution: Vessel owner purchased a new manual bilge pump with a 4' discharge hose.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 24 March 2007 Resolved
Replace Ring buoy with 24" ring buoy, ensure vsls name is stenciled new ring buoy.
Due 24 April 2007
Resolved 15 April 2007
Resolution: Completed
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 April 2006 Resolved
Renew the following first aid kit items: Aspirin, Ice Pack, Eye Wash.
Due 18 May 2006
Resolved 24 April 2006
Resolution: Received email stating all First Aid items have been replaced.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 18 April 2006 Resolved
Provide wiper blade for window wipe, prior to operating with passengers.
Due 18 May 2006
Resolved 18 April 2006
Resolution: Operator had spare in truck and corrected prior to end of inspection.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 18 April 2006 Resolved
Re-stencil life jacket stowage to be legible and reflect 18 lifejackets under port bench, 2 under stbd. and 3 child under port aft stowage bin.
Due 18 May 2006
Resolved 24 April 2006
Resolution: Received email sating all markings have been corrected.
Fire Fighting › Fire Bucket › Availability
Issued 18 April 2006 Resolved
Provide 2 designated 2.5 gal. fire buckets.
Due 18 May 2006
Resolved 24 April 2006
Resolution: Received email stating fire buckets have been replaced and stenciled.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 3 May 2005 Resolved
Renew duct seal compound in cable/ wire ducting in engine space to make space vapor tight. (46 CFR 181.410)
Due 3 May 2005
Resolved 5 May 2005
Resolution: Renewed duct seal compound.
Construction/Loadline › Penetrations
Issued 30 April 2003 Resolved
Make all forward engine room bulkhead penetrations and stuffing pipes vapor-tight. 46 CFR 177.405 (c) LEGACY COMPONENT DESC: Engine Room Bulkhead
Condition: Improper/Lack of Maintenance
Due 30 May 2003
Resolved 15 May 2003
Fire Fighting › Ventilation Systems
Issued 30 April 2003 Resolved
Replace both power driven exhaust hoses/vent pipes. 46 CFR 182.460 LEGACY COMPONENT DESC: Exhaust Hoses
Condition: Improper/Lack of Maintenance
Due 30 May 2003
Resolved 15 May 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 1 May 2002 Resolved
Install/repair exhaust ventilation shutdowns for the fixed (FIREBOY) fire extinguishing system IAW 46 CFR 181.420. A second option is to install a 160 degree F or lower heat detector. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Due 15 June 2002
Resolved 27 May 2002

Ownership record