Records from 1985 to 2012. Most recent: inspection, 17 January 2012.
Inspection history · 90
17 January 2012
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4226364
9 December 2010
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3902757
15 October 2010
Drydock Extension · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3869333
27 February 2010
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3688853
27 February 2010
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3693944
10 September 2008
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3322701
15 July 2008
COI Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3269078
13 February 2008
In-Service Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3146867
11 July 2007
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3071657
18 June 2007
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2966198
17 May 2007
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2933253
4 October 2006
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2757498
1 August 2006
Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2740099
12 May 2006
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2647813
14 March 2005
Administrative Inspection · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2309730
22 October 2004
Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2228670
7 May 2004
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2059293
5 June 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1810231
22 August 2002
Administrative Inspection
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1673303
17 April 2002
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1617536
10 April 2002
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1603270
2 April 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1600284
2 April 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1403331
14 February 2001
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1467729
19 January 2001
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 825335
30 May 2000
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 168859
23 March 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1415332
1 March 2000
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1410241
23 June 1999
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 531518
22 June 1999
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 65327
8 June 1999
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 132170
2 June 1999
Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 803648
2 April 1999
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1395153
24 February 1999
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1447914
17 March 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1388507
27 January 1998
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1123143
23 September 1997
Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1424474
21 September 1997
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 13708
19 May 1997
Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1095947
10 April 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1385975
21 February 1997
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 785216
21 February 1997
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1411413
13 September 1996
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 66186
13 September 1996
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 691533
28 May 1996
Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1404186
12 April 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1080545
1 April 1996
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1355724
7 February 1996
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1438399
9 February 1995
COI Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1357010
2 February 1995
Hull Examination · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1431467
18 November 1994
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 868528
23 September 1994
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1470096
1 September 1994
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 114642
10 March 1994
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 857675
11 February 1994
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 853054
1 February 1994
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1165477
20 September 1993
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 842353
21 July 1993
Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1377016
20 July 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 40874
8 July 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 98640
6 July 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 6893
14 June 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 691534
8 June 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 691535
4 June 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 182975
14 May 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 119653
16 February 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 691532
9 February 1993
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1389604
20 July 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 176953
15 April 1992
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1266640
11 April 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 220950
7 February 1992
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 959776
25 October 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 653162
25 June 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1338113
5 April 1991
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 910760
8 March 1991
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 910238
26 February 1991
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 921309
8 May 1990
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1227725
7 May 1990
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 914286
21 August 1989
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 893503
4 April 1989
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1194084
1 August 1988
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1033883
1 April 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1196853
25 March 1988
COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 886414
18 September 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1007408
29 May 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1335111
26 May 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1026760
6 March 1987
COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1008716
27 February 1986
Credit Drydock · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1301627
9 October 1985
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 986967
28 March 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 982167
Fire Fighting › Fire Pumps › Arrangement
Issued 15 October 2010
Resolved
Pump piping had a flexible hose portion (pedro line) in the discharge line
Action required: 705 - Other - as specified
Due 1 January 2011
Resolved 9 December 2010
Resolution: Corrected at drydock
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 15 October 2010
Resolved
05 portable extinguishers were in their brackts but not mounted to the wall
Action required: 705 - Other - as specified
Due 15 November 2010
Resolved 9 December 2010
Resolution: Corrected at drydock.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 October 2010
Resolved
Provided exhaust lagging on main diesel engines.
Action required: 705 - Other - as specified
Due 15 November 2010
Resolved 9 December 2010
Resolution: Corrected at drydock.
Lifesaving › Inflatable Liferafts › Capacity
Issued 16 July 2008
Resolved
Vessel is limited to 100 total persons on board due to liferaft capacity.
Action required: 705 - Other - as specified
Due 17 July 2009
Resolved 17 October 2008
Resolution: Amended COI.
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 March 2005
Resolved
Do not carry passengers until fire and man overboard drills are conducted to the satisfaction of the attending Coast Guard Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2006
Fire Fighting › Structural Fire Protection - General
Issued 7 May 2004
Resolved
Approximate 4 sqft of insulation missing near ladder in engine room overhead.
Action required: 705 - Other - as specified
Due 14 May 2004
Resolved 7 May 2004
Resolution: Insulation replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 May 2004
Resolved
Leaking exhaust piping penetrating through the lazarette making space IDLH to crew.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2004
Resolution: Seal in lazarette replaced to prevent exhaust from entering space.
Lifesaving › Inflatable Liferafts
Issued 5 June 2003
Resolved
Connect painters from liferafts to weak links on hydrostatic releases IAW mffrs instructions. LEGACY COMPONENT DESC: Painter
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2003
Electrical › Electrical Distribution System (service)
Issued 5 June 2003
Resolved
Install blanks in panel board on bridge where breakers have been removed. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 1 July 2003
Stability › Watertight Integrity
Issued 5 June 2003
Resolved
Complete permanent repairs to grey water line in engineroom outboard port main engine. Exact location indicated to Port Engineer. LEGACY COMPONENT DESC: Grey Water Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 18 February 2004
Navigation › Collision/Grounding Avoidance
Issued 5 June 2003
Resolved
Install appropriately sized bell on board.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 1 July 2003
Engineering
Issued 16 May 2002
Resolved
Grinder in engine room needed to be hard wired or removed from eng room. LEGACY COMPONENT DESC: Grinder in eng room
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 16 May 2002
Resolution: Grinder was removed from engine room.
Electrical › Lighting (service)
Issued 17 April 2002
Resolved
Light fixtures in Orcas room were not operating. Due to lack of maintenance. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 14 May 2002
Resolution: Light fixtures in Orcas Room are working.
Electrical › Lighting (service)
Issued 17 April 2002
Resolved
Electrical boxes in Orcas room missing covers. Need to place covers on boxes. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2002
Resolved 14 May 2002
Resolution: Covers placed on outlet boxes in Orcas Room
Electrical › Lighting (emergency)
Issued 17 April 2002
Resolved
Need to demonstrate emergency lighting throughout vessel LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 14 May 2002
Resolution: Demonstrated proper operation of emergency lighting.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 17 April 2002
Resolved
Replace outlet in engine room with marine grade junkion boxes/covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 14 May 2002
Resolution: Marine grade junkion boxes placed in engine room on all outlets.
Lifesaving › Lifejacket/PFD (Type I)
Issued 17 April 2002
Resolved
Vessel was missing 1 adult PFD. Lacking 100% PFD's on board.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 14 May 2002
Resolution: 100% life jackets on board.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 17 April 2002
Resolved
Vessel did not have on board proof of enrollment in drug alcohol testing.
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 14 May 2002
Resolution: Drug and Alcohol testing letter for company on board vessel.
Stability
Issued 17 April 2002
Resolved
Stability letter not on board vessel.
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 14 May 2002
Resolution: Original stability letter was on board vessel.
Operations/Management › Passenger Operations › Safety Orientation
Issued 17 April 2002
Resolved
No emergency instruction anywhere on board vessel. Vessel needs to create and post emergency instructions.
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 14 May 2002
Resolution: Vessel created and posted emergency instructions.
Accommodation/Occupational Safety › Ventilation
Issued 17 April 2002
Resolved
Vent ducting was taped together with duct tape. Need to replace with fire safe product.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 14 May 2002
Resolution: Replaced duct tape with aluminum duct tape.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 17 April 2002
Resolved
Improper dryer vent ducting tube was used, not the marine approved dryer ducting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 14 May 2002
Resolution: Removed unapproved dryer ducting and replaced with proper ducting.
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 17 April 2002
Resolved
Lagging on stbd main eng exhaust needs replacement. Lagging has holes and is disintigraing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 14 May 2002
Resolution: Lagging replaced around exhaust piping.
Engineering › Generator (propulsion/auxiliary-electric) › Auto Transformer Circuitry
Issued 17 April 2002
Resolved
Vessel needs to demonstrate emergency generator starts and transfers power. Emergency lighting will also be demonstrated at same time.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 14 May 2002
Resolution: Power was dumped and emergency generator came on line automatically, demonstrated e-lighting as well.
Engineering › Steering Gear System
Issued 2 April 2002
Resolved
Steering cable chaffing exhaust lagging. Provide proposal to office of design to eliminate continued chaffing. LEGACY COMPONENT DESC: Linkage
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2002
Resolved 10 April 2002
Resolution: A half pipe was welded to the ehaust pipe to act as cable guide. Checked by [name withheld]
Engineering › Steering Gear System
Issued 2 April 2002
Resolved
Starboard side internal cast top for rudder post cracked. Repair or replace. LEGACY COMPONENT DESC: Rudder
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2002
Resolved 10 April 2002
Resolution: New internal cast top for rudder post installed. Checked by [name withheld]
Electrical › Electrical Distribution System (service)
Issued 2 April 2002
Resolved
Conductor box in engine room does not have a drip pan protecting it from moisture. LEGACY COMPONENT DESC: Conductor
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2002
Resolved 10 April 2002
Resolution: Drip pans installed. Checked by [name withheld]
Electrical › Electrical Distribution System (service)
Issued 2 April 2002
Resolved
Battery charger box without drip pan to provide protection from moisture. LEGACY COMPONENT DESC: Junction Box
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2002
Resolved 10 April 2002
Resolution: Drip pan installed. Checked by [name withheld]
Navigation
Issued 24 February 1999
Resolved
REPAIR CRACK ON STARBOARD RUDDER TAB.
Condition: Unknown
Due 17 March 1999
Resolved 10 March 1999
Construction/Loadline
Issued 24 February 1999
Resolved
COMPLETE INSERTS TO PORT AND STARBOARD MAIN ENGINE EXHAUST PORTS.
Condition: Unknown
Due 17 March 1999
Resolved 10 March 1999
Engineering
Issued 23 September 1997
Resolved
Prove proper operation of port MDE and associated alarms and shutdowns prior to carrying passengers._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 September 1997
Resolved 30 September 1997
Accommodation/Occupational Safety
Issued 1 April 1996
Resolved
PRIOR TO CARRYING PASSENGERS, SANITIZE ALL GALLEY EQUIPMENT AND REEFERS.
Condition: Unknown
Due 15 April 1996
Resolved 17 April 1996
Engineering
Issued 1 April 1996
Resolved
PROVIDE TEST OVERSPEED DEVICES AND LOW LUBE OIL SHUTDOWNS INSTALLED ON BOTHSHIP SERVICE GENERATORS
Condition: Unknown
Due 15 April 1996
Resolved 17 April 1996
Engineering
Issued 1 April 1996
Resolved
PROVIDE RELIEF VALVE FOR AIR COMPRESSOR WHICH WILL LIMIT INTERNAL PRESSURE TO NO MORE THAN 150 PSI.
Condition: Unknown
Due 15 April 1996
Resolved 17 April 1996
Fire Fighting
Issued 1 April 1996
Resolved
CONDUCT SATISFACTORY TEST OF VESSELS FIRE PUMP.
Condition: Unknown
Due 15 April 1996
Resolved 17 April 1996
Electrical
Issued 1 April 1996
Resolved
INSTALL SUITABLE MECHANICAL SLIDER BAR TO ENSURE THAT SSG CAN NOT BE BROUGHT ON LINE WHILE UNDER SHORE POWER.
Condition: Unknown
Due 15 April 1996
Resolved 17 April 1996
Engineering
Issued 9 February 1995
Resolved
FIX STARBOARD MAIN DIESEL ENGINE TACHOMETER.
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Fire Fighting
Issued 9 February 1995
Resolved
PORTABLE FIRE/BILGE PUMP NEEDS SUFFICIENT HOSE TO FIGHT FIRE ABOVE DECKS.
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Electrical
Issued 9 February 1995
Resolved
LABEL MAIN DECK EMERGENCY LIGHTS WITH 'E'.
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Electrical
Issued 9 February 1995
Resolved
STARBOARD SIDE BATTERY BANK NEEDS BRACING FOR ALL BATTERIES.
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Lifesaving
Issued 9 February 1995
Resolved
PROVE COAST GUARD APPROVALS OR REPLACE RING BUOYS 1, 3 AND 4.
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Engineering
Issued 9 February 1995
Resolved
PERFORM REQUIRED TESTS ON SHIP'S SERVICE AND EMERGENCY GENERATORS. TESTS THAT NEED TO BE CONDUCTED INCLUDE OVERSPEED AND LOW LUBE OIL SHUTDOWNS._x001C_ (SOLAS MACHINERY REQUIRMENT)
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Accommodation/Occupational Safety
Issued 9 February 1995
Resolved
REPLACE CRACKED WINDOW IN THE AFT SECTION OF THE GALLEY.
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Documentation
Issued 9 February 1995
Resolved
NEED TO UPDATE FCC SAFETY RADIO TELEPHONE CERTIFICATE (EXP 19JAN95).
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Construction/Loadline
Issued 23 September 1994
Resolved
Provide copy of gauging report completed on vessel during 23SEP94 DDX.
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Construction/Loadline
Issued 23 September 1994
Resolved
Repaint all draft marks
Condition: Unknown
Due 23 September 1994
Resolved 27 September 1994
Construction/Loadline
Issued 23 September 1994
Resolved
Repair hull plate, port side between frames 43 and 46, 6 ft outboard of CVKto 11 ft outboard. To be completed at next drydock in February, 1995.
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Engineering
Issued 23 September 1994
Resolved
Repair metal around port main engine exhaust in steering compartment where wasted.
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Navigation
Issued 23 September 1994
Resolved
Reinstall steering pins w/ cotter key or threads on the underside of the steering gear arm. Pins are installed upside down.
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Construction/Loadline
Issued 23 September 1994
Resolved
Repair fracture at frame 36 at CVK, 18 inches both port and stbd and 18 inches above CVK.
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Electrical
Issued 11 February 1994
Resolved
PROVE PROPER INSTALLATION AND OPERATION OF EMERGENCY GENERATOR
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Fire Fighting
Issued 21 July 1993
Resolved
Provide one additional Halon extinguisher (B-1) to replace discharged extinguisher in engineroom. The above must be completed to the satisfaction of the attending OCMI prior to the carriage of pax. This requirement may be satisfied by fax receipt of servicing.
Condition: Unknown
Due 28 July 1993
Resolved 21 July 1993
Fire Fighting
Issued 21 July 1993
Resolved
Recharge and service or remove SCBAs used during the engineroom fire on 20 July 1993.
Condition: Unknown
Due 28 July 1993
Resolved 21 July 1993
Electrical
Issued 21 July 1993
Resolved
During installation a clamp at a junction box separated two conductors witha metal screw. Working over several years the screw broke through_x001C_ the conductors insulation, shorting them and burning the wire. New clamp of different style installed on renewed wiring.
Condition: Unknown
Due 28 July 1993
Resolved 21 July 1993
Deck/Cargo
Issued 4 April 1989
Resolved
PROVIDE PLANS FOR APPROVAL ON THE ELECTRIC HYDRAULIC GROUND TACKLE SYSTEM. THIS IS TO BE ACCOMPLISHED TO THE SATISFACTION OF THE [name withheld] NO LATER THAN 04 JUNE 1989.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Construction/Loadline
Issued 6 March 1987
Resolved
REPAIR/REPLACE PORT LIGHTS IN STATE ROOMS #16,19,26,27,28,33,34.
Condition: Unknown
Due 6 March 1987
Resolved 6 March 1987
Engineering
Issued 27 February 1986
Resolved
MAKE PERMANENT REPAIRS TO EXHAUST LEAK IN PORT EXHAUST IN WAY OF STERN BULKHEAD IN LAZERRETTE AND PROVE SATISFACTORY REPAIRS.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Electrical
Issued 27 February 1986
Resolved
COMPLETE PERMANENT REPAIRS TO PORT MAIN GENERATOR AND PROVE SATISFACTORY OPERATION.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986