Records from 1985 to 2017. Most recent: inspection, 20 April 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 48
20 April 2017
Type not recorded
No type recorded · Station Valdez · USCG Arctic District (CGD-A) · Activity 6129309
28 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5934133
8 June 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4335736
29 May 2012
Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4327192
12 September 2008
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3323558
28 July 2008
COI Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3282039
10 June 2007
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2972204
29 March 2007
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2897961
9 March 2007
Type not recorded
No type recorded · USCGC NAUSHON (WPB 1311) · USCG Arctic District (CGD-A) · Activity 2893899
26 April 2006
Annual Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2644166
21 April 2005
Deficiency Check
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2459710
12 April 2005
Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2336888
19 June 2003
Re-Inspection · Damage Survey
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1822561
19 June 2003
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1930047
3 March 2003
Periodic Inspection · Hull Examination
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1764404
22 October 2002
Re-Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1697471
9 April 2002
Deficiency Check
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1602974
11 September 2001
Deficiency Check · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1366653
8 March 2001
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1373402
24 July 2000
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1444401
2 September 1999
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1117384
3 August 1999
Re-Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1459532
6 October 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1378524
13 March 1998
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1109137
5 January 1998
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 784475
4 November 1997
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 783179
18 September 1997
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 783129
7 August 1997
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1409729
9 July 1997
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1371898
9 October 1996
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1409572
10 June 1996
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1407695
7 August 1995
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1451003
23 September 1994
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1358538
8 July 1994
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1436891
27 August 1993
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1412563
29 September 1992
Hull Examination · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1455023
7 October 1991
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 950236
24 July 1991
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 942249
11 August 1990
Hull Examination · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1215264
18 August 1989
Re-Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1034131
12 August 1988
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1345033
20 May 1988
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 889568
6 April 1988
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 994425
20 March 1987
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1017661
20 March 1987
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1017821
11 March 1986
Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1292784
10 March 1986
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 998857
12 March 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 978899
Engineering › Fuel Oil Service System › Valve
Issued 29 May 2012
Resolved
Prove proper operation of port emergency fuel shut-off.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2012
Resolution: This item was verified and cleared by MSU Ketchikan prior to vessel departing Ketchikan’s AOR. 835 was lined out and signed off on hard copy 835 onboard copy. md
Engineering › Fuel Oil Service System › Filter
Issued 29 May 2012
Resolved
Install flame bowl on main engine fuel filter.
Due 10 June 2012
Resolved 11 June 2012
Engineering › Fuel Oil Service System › Filter
Issued 29 May 2012
Resolved
Install solid bottom plug on main engine fuel filter.
Due 10 June 2012
Resolved 11 June 2012
Engineering › Fuel Oil Service System › Filter
Issued 29 May 2012
Resolved
Install solid botton plug on generator fuel filter.
Due 10 June 2012
Resolved 11 June 2012
Engineering › Steering Gear System › Linkage
Issued 29 May 2012
Resolved
Prove proper operation of emergency steering system.
Due 10 June 2012
Resolved 11 June 2012
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 May 2012
Resolved
Conduct man overboard drill.
Due 10 June 2012
Resolved 11 June 2012
Fire Fighting › Fire Main › Material
Issued 28 July 2008
Resolved
Replace PVC piping in fire main with suitable materials.
Due 28 August 2008
Resolved 12 September 2008
Stability › Watertight Integrity › Weathertight Enclosure
Issued 28 July 2008
Resolved
Replace WTD gasket in FWD engine room door.
Due 28 August 2008
Resolved 12 September 2008
Engineering › Fuel Oil Service System › Hose
Issued 28 July 2008
Resolved
Provide chaffing gear on all hoses in vital systems that are in risk of wear due to contact with metal surfaces.
Due 28 August 2008
Resolved 12 September 2008
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 28 July 2008
Resolved
Seal all exposed insulation in engine room by taping with approved materials to prevent saturation of oil residue.
Due 28 August 2008
Resolved 12 September 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 28 July 2008
Resolved
Provide cover for light in FWD storage area below decks.
Due 28 August 2008
Resolved 12 September 2008
Operations/Management › Passenger Operations › Safety Orientation
Issued 28 July 2008
Resolved
Provide information on passenger count or voyage plan when appropriate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2008
Resolved 12 September 2008
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 28 July 2008
Resolved
Provide proof of pre-employment drug screening.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2008
Resolved 12 September 2008
Operations/Management › Drills/Instruction › Fire
Issued 28 July 2008
Resolved
Log training and drills.
Due 28 August 2008
Resolved 12 September 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 26 April 2006
Resolved
Lock overboard discharge valve on MSD holding tank to prevent accidental discharge.
Due 10 May 2006
Resolved 29 March 2007
Personnel › Training › First Aid/CPR
Issued 26 April 2006
Resolved
Provide proof of first aid/CPR training.
Due 1 June 2006
Resolved 29 March 2007
Engineering › Pressure Vessel › Relief Valve
Issued 26 April 2006
Resolved
Install and prove proper operations of pressure relief valve IAW manufacturers instructions for engine room air receiver.
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 29 March 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 April 2006
Resolved
Repair emergency light in passageway in lower deck.
Due 1 May 2006
Resolved 29 March 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 26 April 2006
Resolved
Due to condition of B-II fire extinguisher in galley, hydrostatically test or replace at annual service.
Due 1 July 2006
Resolved 29 March 2007
Engineering › Fuel Oil Service System › Vent Pipe
Issued 26 April 2006
Resolved
Install 30x30 stainless steel mesh screen on fuel tank vents.
Due 14 May 2006
Resolved 29 March 2007
Communications › Radio Communications › EPIRB
Issued 12 April 2005
Resolved
Replace hydrostatic release unit on EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 12 April 2005
Resolved
Provide current nautical publications for operating area
Action required: 705 - Other - as specified
Resolved 21 April 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 April 2005
Resolved
Demonstrate proper operation of bilge high level alarm IAW 46CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2005
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 April 2005
Resolved
Provide three additional type 1 life jackets to ensure a total of 51 life jackets. Total persons on board shall be reduced to 48 until 3 additional life jackets are on board.
Action required: 705 - Other - as specified
Resolved 28 April 2005
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 12 April 2005
Resolved
Post life jacket donning placard IAW 46CFR181.516
Action required: 705 - Other - as specified
Resolved 21 April 2005
Communications › Internal Communications System › Portable Radios
Issued 12 April 2005
Resolved
Provide a suitable public address system IAW 46CFR184.610
Action required: 705 - Other - as specified
Resolved 14 April 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 19 June 2003
Resolved
Complete annual servicing of portable fire extinguishers.
Due 1 August 2003
Resolved 11 July 2003
Resolution: Received notification that servicing was complete by approved servicing facility KPB
Construction/Loadline › Hull › Bottom Plating
Issued 19 June 2003
Resolved
Crop and renew area of port bow holed from grounding and gauge area port side creased. If reading present wastage in excess of 25% crop and renew to good metal.
Due 19 June 2003
Resolved 21 June 2003
Resolution: Insert completed with fit up and pressure test upon completion. Creased gauged and identified within allowable standards. Plating IWO crease in good condition. Area cleaned and prepped prior to re-entry to water.
Construction/Loadline › Structures › Scuttle
Issued 22 October 2002
Resolved
Complete maintenance on scuttle leading to passenger accommodations located on aft deck starboard side, presently operations extremely difficult.
Due 22 October 2002
Resolved 22 October 2002
Resolution: Prof of proper operation demonstrated prior to departure. [name withheld]
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 22 October 2002
Resolved
Produce information regarding ASTM testing of new carpeting installed in berthing compartment.
Due 22 October 2002
Resolved 22 October 2002
Resolution: Fact sheets presented which have appropriate ASTM tests with satisfactory results for critical Radiant flux, flame spread and smoke density. On file at MSD Ketchikan, AK [name withheld]
Construction/Loadline
Issued 11 September 2001
Resolved
Prove proper operation of lazarette hatch, with keep open device installed.{Hinge mounted hatch}.
Condition: Unknown
Due 11 November 2001
Resolved 8 April 2002
Resolution: Completed administrative def check. Received faxed letter from [name withheld], master of MV CHRISTIAN attesting to the correction of the above item.
Electrical
Issued 11 September 2001
Resolved
Removed dead ended wire in lazarette.
Condition: Unknown
Due 11 November 2001
Resolved 8 April 2002
Resolution: Competed administrative def check. Received faxed letter from [name withheld], Master of MV CHRISTIAN, attesting to the completion of the above item.
Lifesaving
Issued 11 September 2001
Resolved
Provide proof of registration of newly installed EPIRB.
Condition: Unknown
Due 17 October 2001
Resolved 11 November 2001
Construction/Loadline
Issued 11 September 2001
Resolved
Provide keep open device for forward hatch.
Condition: Unknown
Due 11 November 2001
Resolved 8 April 2002
Resolution: Competed administrative def check. Received faxed letter from [name withheld], Master of MV CHRISTIAN, attesting to the completion of the above item.
Construction/Loadline
Issued 8 March 2001
Resolved
PROVIDE A DOGGING WRENCH FOR READY USE IN VICINITY OF WATERTIGHT SCUTTLE SERVING LAZARETTE.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Fire Fighting
Issued 8 March 2001
Resolved
PROVIDE APPROVED MARINE-TYPE MOUNT FOR ALL PORTABLE FIRE EXTINGUISHERS PER 46 CFR 181.500.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Lifesaving
Issued 24 July 2000
Resolved
Rejected 12 adult PFDs and 1 child PFD. Reduced total persons allowed to 42until required number of PFDs on board to meet total persons allowed as perCOI.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Lifesaving
Issued 24 July 2000
Resolved
Replace lifeline on lifering and attach waterlight with 3-foot lanyard.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Lifesaving
Issued 24 July 2000
Resolved
Both lifelines on 15 man buoyant apparatus deteriorated and in need of replacement.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Electrical
Issued 24 July 2000
Resolved
Install metalic overhead wiring supports every 24 inches in engine room.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Engineering
Issued 3 August 1999
Resolved
Install a means to shut down main diesel engine at the pilot station on bridge.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Electrical
Issued 3 August 1999
Resolved
Install one additional Emergency Light fixture in passageway outside after most berthing compartments. Light must automatically illuminate upon loss of power.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Fire Fighting
Issued 3 August 1999
Resolved
Fabricate and have available vent closure device for natural engine room vent.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Lifesaving
Issued 3 August 1999
Resolved
Procure and post placard giving donning instructions for on board PFDs.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Accommodation/Occupational Safety
Issued 13 March 1998
Resolved
Diesel fuel heater in below deck accomodation space may be operated when nopersonnel or passengers are berthing below. Submit proposal for replacement hot water heating system as discussed with attentding marine inspector.
Condition: Unknown
Due 13 March 1998
Resolved 13 March 1998
Fire Fighting
Issued 18 September 1997
Resolved
Installed CO2 system (ER space protection) has been disconnected (bottles removed) due to improper location (forward berthing area). Prior to reinstallation, submit written proposal with details of installation that will completely isolate system from berthing area.
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Accommodation/Occupational Safety
Issued 18 September 1997
Resolved
Modify escape hatch to open aft, eliminating contact with installed bench._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Accommodation/Occupational Safety
Issued 18 September 1997
Resolved
Diesel heater in below deck accomodation space may be operated when no personnel are below, but shall not be operated while persons are berthed_x001C_ in area. Submit proposal for modifying exhaust routing more directly from berthing area.
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Accommodation/Occupational Safety
Issued 7 August 1997
Resolved
REMOVE DIESEL SPACE HEATER FROM ACCOMODATION SPACE OR PROVIDE APPROVAL LETTER FROM COMDT FOR INSTALLATION.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Engineering
Issued 7 August 1997
Resolved
PROVIDE FLAME SCREEN FOR PORT SIDE MIDSHIPS FUEL TANK GOOSENECK VENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Accommodation/Occupational Safety
Issued 7 August 1997
Resolved
REPLACE CRACKED PORTHOLE GLASS ON STBD SIDE OF HOUSE.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Accommodation/Occupational Safety
Issued 7 August 1997
Resolved
PROVIDE CG-APPROVED FIRST AID KIT OR UPDATE EXISTING KIT.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Fire Fighting
Issued 7 August 1997
Resolved
INSTALL FIRE EXTINGUISHER BRACKETS FOR EXTINGUISHERS IN GALLEY AND ENGINE ROOM.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Accommodation/Occupational Safety
Issued 7 August 1997
Resolved
CLEAR AREA AROUND EMERGENCY ESCAPE HATCH BY REMOVING BENCH INSTALLED AFT OFHOUSE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Accommodation/Occupational Safety
Issued 7 August 1997
Resolved
STENCIL EMERGENCY ESCAPE HATCH "ESCAPE HATCH - KEEP CLEAR"._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Engineering
Issued 7 August 1997
Resolved
PROVIDE FLAMMABLE LIQUID STORAGE LOCKER FOR GAS CAN/PORTABLE FUEL TANKS.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Lifesaving
Issued 29 September 1992
Resolved
TOTAL NUMBER OF PASSENGERS LIMITED TO 45 UNTIL THE 2 REJECTED ADULT LIFE_x001C_ PRESERVERS ARE REPLACED.
Condition: Unknown
Due 29 September 1992
Resolved 29 September 1992
Unknown
Issued 29 September 1992
Resolved
INSTITUTE A RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 29 September 1992
Resolved 29 September 1992
Engineering
Issued 24 July 1991
Resolved
INSTALL METAL DRIP PAN ON M/E RAYCOR FUEL FILTER.
Condition: Unknown
Due 24 July 1991
Resolved 24 July 1991