ROSLYN

ROSLYN is a 1998 towing vessel. The Coast Guard has recorded 16 inspections since 1998, most recently in April 2025, along with 16 deficiencies and 2 casualty investigations between 2002 and 2013.

Records from 1998 to 2025. Most recent: inspection, 21 April 2025.

Built
1998
Last inspected
21 April 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 21 April 2025
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 12 calendar years (1998–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH3835
469597
Flag
UNITED STATES
Maury page id
psix-469597

Documentation record

Registered dimensions (L × B × D)66.0 ft × 22.0 ft × 8.0 ft
Registered tonnagegross 77 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRODRIGUEZ BOAT BUILDERS · CODEN, AL, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it77 - Simplified, Gross Ton
62 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DMS 104 Freight Barge · MISLE 155106 · 13 May 2002 · activity 1624402

Inspection history · 16

21 April 2025 TPO Audit
Administrative · Towing Vessel National Center of Expertise · Activity 8116077
13 March 2025 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8093078
23 December 2021 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7375477
3 June 2020 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6967745
15 April 2019 Administrative Inspection · Initial Certification · USCG Audit
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6645451
10 April 2015 Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 5100596
5 April 2013 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4564888
5 December 2012 Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4517801
26 July 2012 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4391902
21 November 2011 Industry Initiated Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4193743
15 September 2006 Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 2779625
10 October 2005 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2511500
6 March 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2304521
21 January 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2278554
13 May 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1624402
6 May 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 32876

Deficiency record · 16

03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 25 March 2025 Resolved
Any piping system that penetrates the hull below the waterline must be fitted with an accessible valve, located as close to the hull penetration as is practicable, for preventing the accidental admission of water into the vessel either through such pipes or in the event of a fracture of such pipe. The isolation valve installed at the overboard discharge piping was installed outboard inboard between a check valve and flexible hose connected to the MSD. Vessel shall properly install the isolation valve to prevent accidental admission of water if the hard and flexible piping fails prior to departure to the satisfaction of the MI.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2025
Resolution: Received satisfactory objective evidence that vessel installed the isolation valve in the MSD system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2025 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards…The fuel supply flexible hose line connecting the fuel piping to the port generating was significantly worn creating a significant threat to a fire hazard. Vessel shall replace fuel hose prior to departure to the satisfaction of the MI.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2025
Resolution: Received satisfactory objective evidence that vessel installed new fuel supply flexible hose.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 March 2025 Resolved
o stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. There was no remote fuel shut off valve installed in the piping leaving the starboard side fuel tank. Vessel shall install a remote fuel shut off valve prior to departure to the satisfaction of the MI.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2025
Resolution: Received satisfactory objective evidence that vessel installed remote fuel shut off valve for the starboard side fuel tank.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The generator switchboard interlock was inoperable, allowing both generators to run at the same time without parallel safety features. Vessel shall properly install interlock prior to departure to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2025
Resolution: Received satisfactory objective evidence that vessel installed new generator switchboard interlock.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2025 Resolved
A towing vessel that is… Certificated for limited coastwise… whose contract for construction was executed prior to August 27, 2003… must be equipped with either… An approved 160-B semi-portable fire-extinguishing system to protect the engine room or fixed fire-extinguishing system installed to protect the engine room…The vessels chosen option, 160-B, was not installed in a location that would allow the hose to reach anywhere in the engine space, with the exception of the bottom of the ladderway. Vessel shall install the 160-B in a location that is compliance with 46CFR142.230(e) and can reach all areas in the engine space to facilitate extinguishing of a fire prior to departure to the satisfaction of the MI.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2025
Resolution: Received satisfactory objective evidence that vessel moved location of 160-B and can reach all areas in the engine space to facilitate extinguishing of a fire.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 25 March 2025 Resolved
A towing vessel with overnight accommodations and alternating watches (shift work), when pulling, pushing or hauling alongside one or more barges, must have a system to detect when its master or mate (pilot) becomes incapacitated. The system must: Require action from the master or officer in charge of a navigational watch, during an interval not to exceed 10 minutes, in order to reset the alarm timer. The current installation of the alert system is set at 15 minute intervals. Vessel shall ensure the intervals are set to comply with regulations prior to departure to the satisfaction of the MI.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2025
Resolution: Received satisfactory objective evidence that BNWAS interval was set not to exceed 10 minutes in order to reset the alarm timer.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 August 2019 Resolved
Vessel was requesting a Limited Coastwise route but did not have storm rails or hand grabs installed.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 3 June 2020
Resolution: Received email with photos showing storm rails/hand grabs were installed. Vessel may operate on a Limited Coastwise route.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 August 2019 Resolved
Flammable liquid storage cabinet had a 10 B:C extinguisher attached to it. A 40 B extinguisher is required to be attached to the flammable liquid storage cabinet.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 August 2019
Resolution: Verified 40 B extinguisher attached to the flammable liquid storage cabinet.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2019 Resolved
Distribution panel on aft engine room bulkhead was missing identification labels for several breakers.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 August 2019
Resolution: Verified identification labels for several breakers were in place on distribution panel on aft engine room bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 August 2019 Resolved
Excessive leaking from port shaft bearing in which a continuous flow of water was entering the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 August 2019
Resolution: Verified there was no excessive leaking from port shaft bearing.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 August 2019 Resolved
Steering actuator directional control valve located fwd side of hydraulic tank on stbd engine was leaking directly over the battery and battery cover ventilation creating a fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 August 2019
Resolution: Verified steering actuator directional control valve was no longer leaking over the battery and battery cover ventilation.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 8 August 2019 Resolved
Stbd side pilot house handle on the weathertight door would not hold door closed as designed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 August 2019
Resolution: Verified Stbd side pilot house handle on the weathertight door would hold door closed as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 August 2019 Resolved
Posted instructions for launching inflatable survival craft were not located in conspicuous places near where the inflatable survival craft was stored.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 August 2019
Resolution: Verified posted instructions for launching inflatable survival craft were located in conspicuous places near where the inflatable survival craft was stored.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 August 2019 Resolved
Crew was not familiar or well trained on fire drills. Upon conducting a fire drill the Master was unfamiliar with communication procedures and crewmembers were not familiar with proper fire fighting techniques for handling a hose.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 August 2019
Resolution: Verified crew on this vessel was familiar and trained on fire drills. Upon conducting a new fire drill the Master demonstrated proper communication procedures and crewmembers were familiar with proper fire fighting techniques for handling a hose.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 August 2019 Resolved
Current and/or corrected charts were missing.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 August 2019
Resolution: Verified current and/or corrected charts were onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 August 2019 Resolved
Dryer located in the engine room was discovered operating and exhaust ventilation connection missing. Dryer was exhausting on the port main diesel engine creating a fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 August 2019
Resolution: Verified dryer located in the engine room was no longer exhausting on the port main diesel engine creating a fire hazard.

Casualty record · 2

13 May 2002Routine · role: Involved in a Marine Casualty · activity 1624402
5 April 2013Routine · role: Involved in a Marine Casualty · 1 injured · activity 4564888
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

KYLE JOSEPH (2002), COASTAL RUNNER (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.