← All vessels
JOLLY ROGER
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named JOLLY ROGER
JOLLY ROGER is a 1983 passenger vessel (inspected). The Coast Guard has recorded 59 inspections since 1984, most recently in February 2021, along with 60 deficiencies and 1 casualty investigation in 2013.
Records from 1984 to 2021. Most recent: inspection, 2 February 2021.
- Built
- 1983
- Last inspected
- 2 February 2021
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 60 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2013
Identity
1062750
WDD2828
469776
Flag
UNITED STATES
303643000
Maury page id
psix-469776
Inspections, by type
…with no type recorded8
Years with a record
28 calendar years (1984–2021)
The 59 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)41.5 ft × 21.0 ft × 5.8 ft
Registered tonnagegross 14 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderANTHONY COLLINS · ST CROIX, VI, UNITED STATES · built 1983
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationTwin Hull
Hailing portST CROIX, VI
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 30 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
14 - Simplified, Net Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD2828MMSI 303643000 · active · compulsorily equipped · granted 27 May 2026, expires 9 June 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 59
2 February 2021
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7134521
9 September 2019
Internal Structural Exam · Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6807503
3 September 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6802298
30 August 2018
DAPI Audit · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6527511
28 February 2018
Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6365793
31 May 2017
Drydock Exam · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6868728
11 October 2016
Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6020086
4 November 2015
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5756535
19 August 2015
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5226846
13 August 2014
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4953771
11 July 2012
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4376167
31 August 2011
Deficiency Check · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4132167
5 July 2011
DAPI Audit
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4078860
23 November 2010
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3897052
5 November 2010
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3887946
31 October 2008
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3354949
14 April 2008
Hull Examination · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3185568
25 August 2005
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2474052
15 April 2005
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2334568
7 June 2004
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2050732
29 October 2003
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1938354
30 September 2003
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1923700
28 August 2003
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1889474
23 February 2003
Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1748029
8 March 2002
COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1703852
4 October 2001
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1405260
8 July 2001
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1068870
21 May 2001
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1417284
25 April 2000
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1384425
18 August 1999
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1472764
26 July 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1472458
15 July 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1106878
7 June 1999
Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 805184
27 April 1999
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 792099
8 March 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 802359
8 March 1999
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1410066
9 March 1998
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1469500
20 January 1998
Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 774947
7 January 1998
Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 785126
13 August 1997
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1371951
7 March 1997
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1368083
13 January 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1442499
8 July 1996
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 779390
5 July 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1088353
8 March 1996
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 885207
2 February 1996
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1363394
1 March 1995
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1358660
1 July 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 926546
30 January 1990
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1228036
20 November 1989
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1231969
8 April 1989
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1045223
13 July 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 898251
13 July 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1346659
30 June 1988
Hull Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1031408
4 May 1987
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1337876
4 August 1986
Credit Drydock
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 990603
8 April 1986
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1305650
12 February 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 985713
11 December 1984
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1284588
Deficiency record · 60
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 August 2018
Resolved
Lifebuoy and associated line needs replacing. Line was fraying and lifebuoy is at the end of its useful service.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 August 2015
Resolved
Provide working life float light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 August 2015
Resolved
Provide first aid kit.
Communications › Radio Communications › EPIRB
Issued 19 August 2015
Resolved
Provide valid EPIRB.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 13 August 2014
Resolved
Provid Waste Management Plan
Navigation › Piloting/Steering › Marine Charts
Issued 13 August 2014
Resolved
Provide current charts.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 13 August 2014
Resolved
Provide navigation rules.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 13 August 2014
Resolved
Provide working retroreflective material on lifejackets.
Lifesaving › Lifebuoys › Serviceable
Issued 13 August 2014
Resolved
Repair lifebuoy.
Lifesaving › Lifebuoys › Serviceable
Issued 13 August 2014
Resolved
Provide working retroreflective material on lifebuoy.
Electrical › Electric Generation Source (service) › Panelboard
Issued 13 August 2014
Resolved
Provide 03 fuse caps on panel under helm.
Construction/Loadline › Structures › Manhole
Issued 31 July 2012
Resolved
Aft hatches unable to be made water tight. Provide means to secure aft water tight hatches.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 31 July 2012
Resolved
Vessel's name missing from stern. Affix vessel's name in 4" Letters.
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 July 2012
Resolved
Hight water alarms in all water tight compartments are inoperative. Prove proper operation of bilge alarms prior to carrying passengers.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 July 2012
Resolved
Vessel VHF radio did not function and had been modified by wiring in a household stereo speaker to make function. Repair or replace VHF radio. Vessel restricted to no more than 1000ft from shore.
Communications › Radio Communications › EPIRB
Issued 11 July 2012
Resolved
EPIRB HRU expired and antennae broken. Repair. Vessel operations restricted to within 3NM
Construction/Loadline › Structures › Manhole
Issued 11 July 2012
Resolved
Fwd deck hatches missing hasps to secure. Provide means to secure forward hatches.
Lifesaving › Lifefloat › Markings
Issued 11 July 2012
Resolved
Label Life Floats with vessel name and affix retro-reflective tape.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 July 2012
Resolved
Provide Coast Guard approved first aid kit.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 July 2012
Resolved
Provide/Repair 9 adult Life Jackets and three child size life jackets. Passenger allowance reduced to 31 adults/2 children
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 July 2012
Resolved
Vesse; was operating with an invalid COI from February through July 2012.
Construction/Loadline › Hull › Bracket
Issued 31 August 2011
Resolved
Repair or replace main sheet car.
Construction/Loadline › Hull › Bracket
Issued 5 November 2010
Resolved
Replace topping lift line and replace sheave for topping lift line for Jib sail. vessel cannot use Jib sail when passengers are onboard until permanent repair are made.
Construction/Loadline › Hull › Bracket
Issued 5 November 2010
Resolved
replace all missing cotter pins for turn buckles through the vessel.
Unknown
Issued 21 May 2001
Resolved
PROVIDE PORTABLE BILGE/FIRE PUMP IAW TABLE 46 CFR 182.520(A).
System not recorded
Issued 21 May 2001
Resolved
SUBMIT FOR APPROVAL BILGE PLANS IAW 46 CFR 182.
System not recorded
Issued 21 May 2001
Resolved
INSTALL BILGE SYSTEM IAW APPROVED PLANS.
Unknown
Issued 21 May 2001
Resolved
Provide corrosion resistant clip iaw 46 CFR 180.70.
Unknown
Issued 21 May 2001
Resolved
COMPLETE DRILLS TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR.
Unknown
Issued 21 May 2001
Resolved
PROVIDE MAINTENANCE FOR LIFESAVING EQUIPMENT IAW 46 CFR 185 SUBPART G.
System not recorded
Issued 21 May 2001
Resolved
PROVIDE FCC SAFETY CERTIFICATE.
System not recorded
Issued 21 May 2001
Resolved
UPDATE FCC STATION LICENSE TO INCLUDE EPIRB.
Documentation
Issued 8 March 1999
Resolved
Log maintenance of lifesaving equipment and drills.
Documentation
Issued 8 March 1999
Resolved
Post emergency instructions
Construction/Loadline
Issued 8 March 1999
Resolved
Replace bent forestay pin on forward upper rigging.
Lifesaving
Issued 8 March 1999
Resolved
Post life jacket placard.
Documentation
Issued 8 March 1999
Resolved
Provide evidence of compliance with drug testing program.
Deck/Cargo
Issued 9 March 1998
Resolved
Replace starboard Bob Stay
Deck/Cargo
Issued 9 March 1998
Resolved
Replace lower Jaw Eye toggle on forestay.
Navigation
Issued 9 March 1998
Resolved
Replace the 1/2" nut missing from the starboard tiller arm
Accommodation/Occupational Safety
Issued 9 March 1998
Resolved
Repair top step of ladder at entrance to port hull.
Documentation
Issued 7 March 1997
Resolved
Log all man overboard and abandon ship drills IAW 46CFR185.520(g)
Navigation
Issued 7 March 1997
Resolved
Provide a radio emergency broadcast placard IAW 46CFR184.506
Lifesaving
Issued 7 March 1997
Resolved
Provide EPIRB IAW 46CFR180.64_x001C_ _x001C_ Test EPIRB Monthly and log tests IAW 46CFR185.728(c)
Lifesaving
Issued 7 March 1997
Resolved
Provide Life Jacket Placard IAW 46CFR185.516
Documentation
Issued 7 March 1997
Resolved
Provide log book for foreign voyages
Lifesaving
Issued 7 March 1997
Resolved
Provide corrosion resistant clip to attach lanyard to light IAW 46CFR180.70(d)
Documentation
Issued 7 March 1997
Resolved
Log required crew training IAW 46CFR420(b)
Documentation
Issued 7 March 1997
Resolved
log fire fighting drills IAW 46CFR185.524(e)
Documentation
Issued 5 July 1996
Resolved
VESSEL LIMITED TO 42 TOTAL PERSONS ON BOARD. RESUBMIT INFORMATION AND CALCULATIONS TO THE MARINE SAFETY CENTER FOR APPROVAL TO CARRY 44 TOTAL PERSONS ON BOARD.
Documentation
Issued 8 March 1996
Resolved
VESSEL LIMITED TO 30 PASSENGERS FOR HIRE UNTIL RESULTS OF DEAD WEIGHT SURVEY ARE APPROVED BY COAST GUARD MARINE SAFETY CENTRE (MSC).
Construction/Loadline
Issued 1 March 1995
Resolved
PORT HULL FOREPEAK, REPLACE ROTTED INBOARD SHEER CLAMP AND CHAIN PLATE FRAME.
Construction/Loadline
Issued 1 March 1995
Resolved
IN STBD HULL #1 VOID, REPLACE ROTTED INBOARD LONG AT FRAME #2 AND INSERT HULL IN SAME AREA TO GOOD WOOD.
Construction/Loadline
Issued 1 March 1995
Resolved
IN STBD HULL VOID #3, REPLACE ROTTED INBOARD UPPER LONG
Construction/Loadline
Issued 1 March 1995
Resolved
STBD HULL VOID #2, REPLACE ROTTED FRAMING IN AREA OF FRAME #3
Construction/Loadline
Issued 1 March 1995
Resolved
PORT HULL VOID #2, REPLACE ROTTED LONG #1 INBOARD AND INSERT HULL TO GOOD WOOD IN SAME AREA
Navigation
Issued 30 June 1988
Resolved
NEEDS NEW COMPRESSED AIR BOTTLE FOR SHIP'S HORN
Lifesaving
Issued 4 May 1987
Resolved
VSL HAD TWO BAD LIFEJACKETS
Lifesaving
Issued 4 May 1987
Resolved
MSG WATER LIGHT FOR RING BUOY
Lifesaving
Issued 4 May 1987
Resolved
PFD LOCKERS NEED TO BE MARKED
Casualty record · 1
18 March 2013Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 4556521
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.