MAURY USCG vessel records Sign in
← All vessels

JOLLY ROGER

JOLLY ROGER is a 1983 passenger vessel (inspected). The Coast Guard has recorded 59 inspections since 1984, most recently in February 2021, along with 60 deficiencies and 1 casualty investigation in 2013.

Records from 1984 to 2021. Most recent: inspection, 2 February 2021.

Built
1983
Last inspected
2 February 2021
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2828
469776
Flag
UNITED STATES
303643000
Maury page id
psix-469776

Inspections, by type

…with no type recorded8
Years with a record 28 calendar years (1984–2021)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)41.5 ft × 21.0 ft × 5.8 ft
Registered tonnagegross 14 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderANTHONY COLLINS · ST CROIX, VI, UNITED STATES · built 1983
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationTwin Hull
Hailing portST CROIX, VI
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 30 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD2828MMSI 303643000 · active · compulsorily equipped · granted 27 May 2026, expires 9 June 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 59

2 February 2021 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7134521
9 September 2019 Internal Structural Exam · Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6807503
3 September 2019 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6802298
30 August 2018 DAPI Audit · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6527511
28 February 2018 Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6365793
31 May 2017 Drydock Exam · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6868728
11 October 2016 Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6020086
4 November 2015 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5756535
19 August 2015 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5226846
13 August 2014 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4953771
11 July 2012 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4376167
31 August 2011 Deficiency Check · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4132167
5 July 2011 DAPI Audit
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4078860
23 November 2010 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3897052
5 November 2010 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3887946
31 October 2008 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3354949
14 April 2008 Hull Examination · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3185568
25 August 2005 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2474052
15 April 2005 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2334568
7 June 2004 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2050732
29 October 2003 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1938354
30 September 2003 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1923700
28 August 2003 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1889474
23 February 2003 Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1748029
8 March 2002 COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1703852
4 October 2001 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1405260
8 July 2001 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1068870
21 May 2001 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1417284
25 April 2000 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1384425
18 August 1999 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1472764
26 July 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1472458
15 July 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1106878
7 June 1999 Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 805184
27 April 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 792099
8 March 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 802359
8 March 1999 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1410066
9 March 1998 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1469500
20 January 1998 Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 774947
7 January 1998 Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 785126
13 August 1997 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1371951
7 March 1997 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1368083
13 January 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1442499
8 July 1996 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 779390
5 July 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1088353
8 March 1996 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 885207
2 February 1996 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1363394
1 March 1995 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1358660
1 July 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 926546
30 January 1990 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1228036
20 November 1989 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1231969
8 April 1989 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1045223
13 July 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 898251
13 July 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1346659
30 June 1988 Hull Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1031408
4 May 1987 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1337876
4 August 1986 Credit Drydock
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 990603
8 April 1986 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1305650
12 February 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 985713
11 December 1984 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1284588

Deficiency record · 60

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 August 2018 Resolved
Lifebuoy and associated line needs replacing. Line was fraying and lifebuoy is at the end of its useful service.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2018
Resolved 31 August 2018
Resolution: Replaced as new.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 August 2015 Resolved
Provide working life float light.
Action required: 705 - Other - as specified
Due 19 September 2015
Resolved 2 September 2015
Resolution: Life float light provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 August 2015 Resolved
Provide first aid kit.
Action required: 705 - Other - as specified
Due 19 September 2015
Resolved 2 September 2015
Resolution: First aid kit provided.
Communications › Radio Communications › EPIRB
Issued 19 August 2015 Resolved
Provide valid EPIRB.
Action required: 705 - Other - as specified
Due 19 August 2015
Resolved 2 September 2015
Resolution: EBIRB renewed.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 13 August 2014 Resolved
Provid Waste Management Plan
Action required: 705 - Other - as specified
Due 13 September 2014
Resolved 11 September 2014
Resolution: Waste management plan created
Navigation › Piloting/Steering › Marine Charts
Issued 13 August 2014 Resolved
Provide current charts.
Action required: 705 - Other - as specified
Due 13 September 2014
Resolved 11 September 2014
Resolution: Current charts provided.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 13 August 2014 Resolved
Provide navigation rules.
Action required: 705 - Other - as specified
Due 13 September 2014
Resolved 11 September 2014
Resolution: Nav rules provided
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 13 August 2014 Resolved
Provide working retroreflective material on lifejackets.
Action required: 705 - Other - as specified
Due 13 September 2014
Resolved 11 September 2014
Resolution: Retro replaced
Lifesaving › Lifebuoys › Serviceable
Issued 13 August 2014 Resolved
Repair lifebuoy.
Action required: 705 - Other - as specified
Due 13 September 2014
Resolved 11 September 2014
Resolution: Lifebuoy repaired
Lifesaving › Lifebuoys › Serviceable
Issued 13 August 2014 Resolved
Provide working retroreflective material on lifebuoy.
Action required: 705 - Other - as specified
Due 13 September 2014
Resolved 11 September 2014
Resolution: Retro replaced
Electrical › Electric Generation Source (service) › Panelboard
Issued 13 August 2014 Resolved
Provide 03 fuse caps on panel under helm.
Action required: 705 - Other - as specified
Due 13 September 2014
Resolved 11 September 2014
Resolution: Caps placed on panel.
Construction/Loadline › Structures › Manhole
Issued 31 July 2012 Resolved
Aft hatches unable to be made water tight. Provide means to secure aft water tight hatches.
Action required: 705 - Other - as specified
Due 1 September 2012
Resolved 30 August 2012
Resolution: Witnessed hinges installed on aft hatches. Sat.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 31 July 2012 Resolved
Vessel's name missing from stern. Affix vessel's name in 4" Letters.
Action required: 705 - Other - as specified
Due 1 October 2012
Resolved 30 August 2012
Resolution: Vessel''s name has been affixed to stern in 4" letters.
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 July 2012 Resolved
Hight water alarms in all water tight compartments are inoperative. Prove proper operation of bilge alarms prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2012
Resolved 13 July 2012
Resolution: Speaker for bilge alarms was wasted. Replaced main receiving unit. Attended vessel and witnessed proper operation of all bilge alarms.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 July 2012 Resolved
Vessel VHF radio did not function and had been modified by wiring in a household stereo speaker to make function. Repair or replace VHF radio. Vessel restricted to no more than 1000ft from shore.
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 13 July 2012
Resolution: Vessel Master [name withheld] provided new replacement radio.
Communications › Radio Communications › EPIRB
Issued 11 July 2012 Resolved
EPIRB HRU expired and antennae broken. Repair. Vessel operations restricted to within 3NM
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 31 July 2012
Resolution: New HRU and antennae installed and tested sat.
Construction/Loadline › Structures › Manhole
Issued 11 July 2012 Resolved
Fwd deck hatches missing hasps to secure. Provide means to secure forward hatches.
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 31 July 2012
Resolution: Hasps installed on fwd deck hatches making them water tight.
Lifesaving › Lifefloat › Markings
Issued 11 July 2012 Resolved
Label Life Floats with vessel name and affix retro-reflective tape.
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 31 July 2012
Resolution: Life Floats witnessed with vessel''s name stencilled and retro-reflective tape installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 July 2012 Resolved
Provide Coast Guard approved first aid kit.
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 31 July 2012
Resolution: Valid items for first aid kit provided onboard.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 July 2012 Resolved
Provide/Repair 9 adult Life Jackets and three child size life jackets. Passenger allowance reduced to 31 adults/2 children
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 31 July 2012
Resolution: Life jackets repaired. All sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 July 2012 Resolved
Vesse; was operating with an invalid COI from February through July 2012.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 July 2012
Resolution: Issued temporary COI.
Construction/Loadline › Hull › Bracket
Issued 31 August 2011 Resolved
Repair or replace main sheet car.
Due 11 November 2011
Resolved 13 July 2012
Resolution: Vessel Master [name withheld] removed main sheet car and lashed main sheet boom to vessel.
Construction/Loadline › Hull › Bracket
Issued 5 November 2010 Resolved
Replace topping lift line and replace sheave for topping lift line for Jib sail. vessel cannot use Jib sail when passengers are onboard until permanent repair are made.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2010
Resolved 23 November 2010
Resolution: item replace
Construction/Loadline › Hull › Bracket
Issued 5 November 2010 Resolved
replace all missing cotter pins for turn buckles through the vessel.
Action required: 705 - Other - as specified
Due 12 November 2010
Resolved 23 November 2010
Resolution: items replace
Unknown
Issued 21 May 2001 Resolved
PROVIDE PORTABLE BILGE/FIRE PUMP IAW TABLE 46 CFR 182.520(A).
Condition: Unknown
Due 21 May 2001
Resolved 21 May 2001
System not recorded
Issued 21 May 2001 Resolved
SUBMIT FOR APPROVAL BILGE PLANS IAW 46 CFR 182.
Condition: Unknown
Due 1 October 2003
Resolved 29 September 2003
Resolution: Vessel owner submitted bilge piping plan as required. Plan filed to vessel permanent file. [name withheld]
System not recorded
Issued 21 May 2001 Resolved
INSTALL BILGE SYSTEM IAW APPROVED PLANS.
Condition: Unknown
Due 31 August 2001
Resolved 28 August 2003
Unknown
Issued 21 May 2001 Resolved
Provide corrosion resistant clip iaw 46 CFR 180.70.
Condition: Unknown
Due 21 May 2001
Resolved 21 May 2001
Unknown
Issued 21 May 2001 Resolved
COMPLETE DRILLS TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR.
Condition: Unknown
Due 21 May 2001
Resolved 21 May 2001
Unknown
Issued 21 May 2001 Resolved
PROVIDE MAINTENANCE FOR LIFESAVING EQUIPMENT IAW 46 CFR 185 SUBPART G.
Condition: Unknown
Due 21 May 2001
Resolved 21 May 2001
System not recorded
Issued 21 May 2001 Resolved
PROVIDE FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 21 June 2001
Resolved 28 August 2003
System not recorded
Issued 21 May 2001 Resolved
UPDATE FCC STATION LICENSE TO INCLUDE EPIRB.
Condition: Unknown
Due 21 June 2001
Resolved 21 May 2001
Documentation
Issued 8 March 1999 Resolved
Log maintenance of lifesaving equipment and drills.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Documentation
Issued 8 March 1999 Resolved
Post emergency instructions
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Construction/Loadline
Issued 8 March 1999 Resolved
Replace bent forestay pin on forward upper rigging.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Lifesaving
Issued 8 March 1999 Resolved
Post life jacket placard.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Documentation
Issued 8 March 1999 Resolved
Provide evidence of compliance with drug testing program.
Condition: Unknown
Due 8 April 1999
Resolved 31 March 1999
Deck/Cargo
Issued 9 March 1998 Resolved
Replace starboard Bob Stay
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Deck/Cargo
Issued 9 March 1998 Resolved
Replace lower Jaw Eye toggle on forestay.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Navigation
Issued 9 March 1998 Resolved
Replace the 1/2" nut missing from the starboard tiller arm
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Accommodation/Occupational Safety
Issued 9 March 1998 Resolved
Repair top step of ladder at entrance to port hull.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Documentation
Issued 7 March 1997 Resolved
Log all man overboard and abandon ship drills IAW 46CFR185.520(g)
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Navigation
Issued 7 March 1997 Resolved
Provide a radio emergency broadcast placard IAW 46CFR184.506
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Lifesaving
Issued 7 March 1997 Resolved
Provide EPIRB IAW 46CFR180.64_x001C_ _x001C_ Test EPIRB Monthly and log tests IAW 46CFR185.728(c)
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Lifesaving
Issued 7 March 1997 Resolved
Provide Life Jacket Placard IAW 46CFR185.516
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Documentation
Issued 7 March 1997 Resolved
Provide log book for foreign voyages
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Lifesaving
Issued 7 March 1997 Resolved
Provide corrosion resistant clip to attach lanyard to light IAW 46CFR180.70(d)
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Documentation
Issued 7 March 1997 Resolved
Log required crew training IAW 46CFR420(b)
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Documentation
Issued 7 March 1997 Resolved
log fire fighting drills IAW 46CFR185.524(e)
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Documentation
Issued 5 July 1996 Resolved
VESSEL LIMITED TO 42 TOTAL PERSONS ON BOARD. RESUBMIT INFORMATION AND CALCULATIONS TO THE MARINE SAFETY CENTER FOR APPROVAL TO CARRY 44 TOTAL PERSONS ON BOARD.
Condition: Unknown
Due 5 September 1996
Resolved 23 July 1996
Documentation
Issued 8 March 1996 Resolved
VESSEL LIMITED TO 30 PASSENGERS FOR HIRE UNTIL RESULTS OF DEAD WEIGHT SURVEY ARE APPROVED BY COAST GUARD MARINE SAFETY CENTRE (MSC).
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Construction/Loadline
Issued 1 March 1995 Resolved
PORT HULL FOREPEAK, REPLACE ROTTED INBOARD SHEER CLAMP AND CHAIN PLATE FRAME.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Construction/Loadline
Issued 1 March 1995 Resolved
IN STBD HULL #1 VOID, REPLACE ROTTED INBOARD LONG AT FRAME #2 AND INSERT HULL IN SAME AREA TO GOOD WOOD.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Construction/Loadline
Issued 1 March 1995 Resolved
IN STBD HULL VOID #3, REPLACE ROTTED INBOARD UPPER LONG
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Construction/Loadline
Issued 1 March 1995 Resolved
STBD HULL VOID #2, REPLACE ROTTED FRAMING IN AREA OF FRAME #3
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Construction/Loadline
Issued 1 March 1995 Resolved
PORT HULL VOID #2, REPLACE ROTTED LONG #1 INBOARD AND INSERT HULL TO GOOD WOOD IN SAME AREA
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Navigation
Issued 30 June 1988 Resolved
NEEDS NEW COMPRESSED AIR BOTTLE FOR SHIP'S HORN
Condition: Unknown
Due 30 June 1988
Resolved 30 June 1988
Lifesaving
Issued 4 May 1987 Resolved
VSL HAD TWO BAD LIFEJACKETS
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Lifesaving
Issued 4 May 1987 Resolved
MSG WATER LIGHT FOR RING BUOY
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Lifesaving
Issued 4 May 1987 Resolved
PFD LOCKERS NEED TO BE MARKED
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987

Casualty record · 1

18 March 2013Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 4556521
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.