This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it14786 - Convention (Subpart B), Gross Ton 8210 - Convention (Subpart B), Net Ton 24132 - Dead Weight, Ton 29603 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 2
10 June 2016ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5903149
14 April 2016Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5854589
0750-Fire Prevention. Jacketed piping system shall include means for collection of leakings and arrangements shall be provided for an alarm of a fuel line failure. Drain valve was left in open position by-passing alarm. SOLAS (11) II-2/15.9
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 18 June 2016
Resolution: Crew closed valve, locked shut and installed sinage reading "Valve to Remain Close at all times".
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 10 June 2016Resolved
0750-Fire Prevention. Fuel oil sight glasses shall be fitted with a Cock or Valve capable of being closed from a safe position. Sight glasses measuring devices were gagged open and dissassembeled. SOLAS (11)II-2/15.5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 18 June 2016
Resolution: Gags were removed from two oil tanks and Sight glass meters were reassembeled on two fuel tanks while exam team was still on board the vessel.