Inspection history · 25
2 February 2026
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8306889
21 July 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8190947
27 January 2025
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8070527
22 August 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7987027
25 July 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7967775
25 July 2024
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7974863
28 July 2023
Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7853661
16 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7689571
16 May 2023
Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7689889
19 January 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7624064
31 August 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7548270
12 May 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7449526
2 June 2021
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7215814
9 April 2021
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7172055
22 March 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7172197
18 September 2020
Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7061055
16 June 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6978686
7 October 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6829618
29 May 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6696693
20 March 2019
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6645869
2 February 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6618971
15 May 2018
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6415336
7 June 2017
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6168410
30 January 2017
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6079718
12 April 2016
COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5846959
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 21 July 2025
Resolved
Vessels roving watch system was inoperable. Operator was not using system due to the system not reseting if the alarm was engaged. Vessel contacted technician and talked through how to reset. Vessel was educated on how to reset the system to prevent troubles in the future and the need to use the system was discussed.46 CFR 185.410
Action required: 10 - Deficiency Rectified
Resolved 21 July 2025
Resolution: Vessel contacted technician while we were out there, walking him through how to reset it.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 July 2025
Resolved
Discovered that battery cables and the primary conductor from the generator were routed through the bilge. Re-route these cables to be as high as practicable above the bilge. The wiring shall hang with metal supports spaced not more than 24 inches and have no sharp bends in the wires. Code: 50c. Cite: 46 CFR 183.200(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 August 2025
Resolution: Vessel sent pictures and stated cabling was above bilges.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 July 2025
Resolved
Discovered a junction box on the upper deck by the starboard IBA, which was missing its cover. Replace the junction box cover.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2025
Resolution: Pic sent of replaced junction box
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 July 2025
Resolved
The ringbuoy’s floating waterlight was inoperable. Repair/replace the waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2025
Resolution: Operator sent in documentation and stated the waterlight was operable.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 21 July 2025
Resolved
The port quarter window of the pilot house was severely cracked. Replace the damaged window at DDX
Action required: 705 - Other - as specified
Due 31 January 2027
Resolved 2 February 2026
Resolution: Witnessed satisfactory installation of repairs. All sat
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 July 2025
Resolved
Except on vessels limited to daytime operations, the compass mounted at the operations station must be illuminated.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 August 2025
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 21 July 2025
Resolved
Radio lifesaving appliance installations and arrangements must comply with 46 CFR part 80. Vessels radio did not have the MMSI number programed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 August 2025
Resolution: Rcvd picture of updated radio installation
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 July 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons and the vessel from electrical hazards including fire caused by or originating in electrical equipment and shock. Remove all wires not currently being used, properly dead end all wires and remove surge protectors under consul in wheelhouse and hard wire all permanent equipment being used. Ensure all grounding wires. Submit proposal for approval if changing any electrical components.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 August 2025
Resolution: Cleared via email
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 July 2025
Resolved
As appropriate a vessel mucy carry adequate and up to date: charts and publications as listed in 46 CFR 184.420.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2025
Resolution: Rcvd pictures of updated charts
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 January 2025
Resolved
Angel hair and soft wood was found throughout laz. Take down to good wood and as necessary recommend repairs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Inspected repairs. All sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 January 2025
Resolved
Angel hair and soft wood was found throughout engine room. Take down to good wood and as necessary recommend repairs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Inspected repairs. All sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 January 2025
Resolved
Longitudinal in engine room was found with rot. Take down to good wood and submit repair proposal.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Inspected repairs. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 27 January 2025
Resolved
Sewage gate valve was found with a hole. As proposed, replace with ball valve.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Inspected repairs. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 August 2024
Resolved
An interconnected detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. Interconnected fire detection system not operational. Provide operational fire detection system. Vessel restricted to limited coastwise.
Cite: 46 CFR 181.450
Action required: 705 - Other - as specified
Resolved 22 August 2024
Resolution: Detectors were corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 July 2024
Resolved
Vessel was unable to restart MDEs or gen-set due to inoperable start battery. Repair/replace starting battery prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2024
Resolution: Vessel replaced all batteries on board.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 16 May 2023
Resolved
After March 24, 2019, a person may not employ or engage any individual on a national voyage that is required to hold an MMC unless that individual maintains a current medical certificate. 00 of the vessel's licensed crew members does not have evidence of a valid medical certificate. Provide evidence of valid medical certificate for the affected crew member. The affected crew member may not stand in a licensed Master or Mate position on the vessel until this deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 16 July 2025
Resolution: Legacy 835, closed out due to age
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2023
Resolved
Vessel's ring life buoy has a breached plug. Repair the plug per a manufacturer approved repair method or replace the ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 17 May 2023
Resolution: Vessel purchased a new ring buoy. Inspected as satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 May 2022
Resolved
Vessel operators required to instruct each crew member once every three (03) months as to the duties that the member is expected to perform in an emergency. Last drills were recorded in November, 2021. Operator required to conduct emergency drills with all crew members prior to them getting underway with passengers.
Action required: 10 - Deficiency Rectified
Resolved 12 May 2022
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 12 May 2022
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. No flamescreen was installed on the vent pipe end from the fuel tank on the port side. Must repair to satisfaction of USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 13 May 2022
Resolution: Def rectified onsite...[name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2021
Resolved
Fuel clamps required on all flex fuel lines in engine space.
Action required: 10 - Deficiency Rectified
Due 4 June 2021
Resolved 4 June 2021
Resolution: Installed clamps fuel line clamps on all flex fuel lines in engine space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 June 2021
Resolved
Voltmeter/Ammeter must be properly working for the ship service generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2021
Resolved 16 May 2023
Resolution: New Voltmeter/ammeter installed and inspected.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 April 2021
Resolved
Vessel's COI expires on 12APR21 and has not completed a COI renewal inspection. Vessel is restricted from carrying passengers until successful completion of COI inspection.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 June 2021
Resolution: Completed COI renewal, issued new COI.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 7 October 2019
Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously.
Action required: 10 - Deficiency Rectified
Due 7 October 2019
Resolved 7 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 7 January 2020
Resolved 16 June 2020
Resolution: Verified by [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2019
Resolved
All vessel electrical switchboards must be compliant with marine safety standards. It was discovered that there is exposed wiring going into the panel box and there openings that need to be blanked off. Must make corrections to the satisfaction of the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 1 November 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2018
Resolved
Install pre-engineered fixed fire extinguishing bottle in the E/R and prove proper operation
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2018
Resolved
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2018
Resolved 24 May 2018
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 May 2018
Resolved
Properly secure ladder leading to upper deck
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2018
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 15 May 2018
Resolved
Provide EPIRB Hydrostatic release
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2018
Resolved
Replace electric cord for cooler
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 16 May 2018
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 May 2018
Resolved
Renew fuel line suction on port and starboard mde
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 17 May 2018
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 May 2018
Resolved
Prove proper operation on E/R ventilation dampners.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 16 May 2018
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 June 2017
Resolved
Install covers or guards on rotating machinery; galley exhaust fan pulley, water maker pump.
Condition: Improper Installation
Due 7 July 2017
Resolved 24 July 2017
Resolution: Covers and guards installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 June 2017
Resolved
Cover battery terminals under pilothouse console
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 24 July 2017
Resolution: Battery terminals under pilothouse console are covered.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 7 June 2017
Resolved
Properly label diesel fuel fill caps.
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 24 July 2017
Resolution: Properly labeled.
Construction/Loadline › Hull › Stiffener
Issued 30 January 2017
Resolved
Make repairs to transum as planned with thru bolts and backing plates.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 30 March 2017
Resolution: Witnessed satisfactory installation of transom stiffeners. Stiffeners are installed with through bolts through the transom. All work was sealed with 5200.