Records from 1984 to 2026. Most recent: inspection, 2 February 2026.
Inspection history · 96
2 February 2026
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8306889
21 July 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8190947
27 January 2025
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8070527
22 August 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7987027
25 July 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7967775
25 July 2024
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7974863
28 July 2023
Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7853661
16 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7689571
16 May 2023
Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7689889
19 January 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7624064
31 August 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7548270
12 May 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7449526
2 June 2021
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7215814
9 April 2021
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7172055
22 March 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7172197
18 September 2020
Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7061055
16 June 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6978686
7 October 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6829618
29 May 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6696693
20 March 2019
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6645869
2 February 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6618971
15 May 2018
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6415336
7 June 2017
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6168410
30 January 2017
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6079718
12 April 2016
COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5846959
15 May 2014
DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4859224
2 May 2012
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4300406
25 August 2011
Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4126194
18 March 2009
Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3404214
27 January 2009
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3401184
14 August 2008
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3303089
3 April 2008
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3163328
11 April 2007
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2889468
2 April 2007
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2889466
12 April 2006
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2604397
28 June 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2406451
9 June 2005
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2389712
25 April 2005
Hull Examination · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2339225
5 April 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2326934
29 April 2004
Examination of Repairs · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2047618
13 April 2004
Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2030529
11 April 2003
Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1769283
4 April 2003
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1767496
2 May 2002
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1611897
8 April 2002
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1602223
12 February 2002
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1485812
25 December 2001
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1473717
29 August 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1071441
20 July 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 157760
20 July 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 225460
20 July 2001
Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1457968
14 May 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1063770
10 May 2001
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1068335
13 April 2001
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1391543
4 April 2001
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1393640
1 February 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1397572
21 April 2000
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1384419
21 March 2000
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1450425
21 April 1999
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1384113
10 March 1999
Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 805086
22 April 1998
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1394970
13 April 1998
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1368733
22 April 1997
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1438572
22 April 1996
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1409487
4 April 1996
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1465246
27 April 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1178434
5 April 1995
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1153985
31 May 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1326434
10 May 1994
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1169084
10 May 1994
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1169465
9 December 1993
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 850055
3 December 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 849476
22 November 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1401774
10 May 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 830034
14 May 1992
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 958851
5 May 1992
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 944534
7 May 1991
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 923000
10 January 1991
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 916226
8 November 1990
Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 914881
4 September 1990
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1235299
13 July 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1213269
17 May 1990
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241808
19 March 1990
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1238906
7 March 1990
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241731
20 February 1990
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1236578
29 December 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1229635
22 May 1989
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1194871
19 May 1989
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 888724
18 May 1989
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1196161
23 May 1988
Re-Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1045186
27 May 1987
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1334080
16 December 1986
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1333648
12 May 1986
COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1301077
4 June 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1288050
23 May 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1291050
30 November 1984
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1284704
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 21 July 2025
Resolved
Vessels roving watch system was inoperable. Operator was not using system due to the system not reseting if the alarm was engaged. Vessel contacted technician and talked through how to reset. Vessel was educated on how to reset the system to prevent troubles in the future and the need to use the system was discussed.46 CFR 185.410
Action required: 10 - Deficiency Rectified
Resolved 21 July 2025
Resolution: Vessel contacted technician while we were out there, walking him through how to reset it.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 July 2025
Resolved
Discovered that battery cables and the primary conductor from the generator were routed through the bilge. Re-route these cables to be as high as practicable above the bilge. The wiring shall hang with metal supports spaced not more than 24 inches and have no sharp bends in the wires. Code: 50c. Cite: 46 CFR 183.200(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 August 2025
Resolution: Vessel sent pictures and stated cabling was above bilges.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 July 2025
Resolved
Discovered a junction box on the upper deck by the starboard IBA, which was missing its cover. Replace the junction box cover.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2025
Resolution: Pic sent of replaced junction box
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 July 2025
Resolved
The ringbuoy’s floating waterlight was inoperable. Repair/replace the waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2025
Resolution: Operator sent in documentation and stated the waterlight was operable.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 21 July 2025
Resolved
The port quarter window of the pilot house was severely cracked. Replace the damaged window at DDX
Action required: 705 - Other - as specified
Due 31 January 2027
Resolved 2 February 2026
Resolution: Witnessed satisfactory installation of repairs. All sat
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 July 2025
Resolved
Except on vessels limited to daytime operations, the compass mounted at the operations station must be illuminated.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 August 2025
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 21 July 2025
Resolved
Radio lifesaving appliance installations and arrangements must comply with 46 CFR part 80. Vessels radio did not have the MMSI number programed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 August 2025
Resolution: Rcvd picture of updated radio installation
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 July 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons and the vessel from electrical hazards including fire caused by or originating in electrical equipment and shock. Remove all wires not currently being used, properly dead end all wires and remove surge protectors under consul in wheelhouse and hard wire all permanent equipment being used. Ensure all grounding wires. Submit proposal for approval if changing any electrical components.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 August 2025
Resolution: Cleared via email
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 July 2025
Resolved
As appropriate a vessel mucy carry adequate and up to date: charts and publications as listed in 46 CFR 184.420.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2025
Resolution: Rcvd pictures of updated charts
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 January 2025
Resolved
Angel hair and soft wood was found throughout laz. Take down to good wood and as necessary recommend repairs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Inspected repairs. All sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 January 2025
Resolved
Angel hair and soft wood was found throughout engine room. Take down to good wood and as necessary recommend repairs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Inspected repairs. All sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 January 2025
Resolved
Longitudinal in engine room was found with rot. Take down to good wood and submit repair proposal.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Inspected repairs. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 27 January 2025
Resolved
Sewage gate valve was found with a hole. As proposed, replace with ball valve.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Inspected repairs. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 August 2024
Resolved
An interconnected detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. Interconnected fire detection system not operational. Provide operational fire detection system. Vessel restricted to limited coastwise.
Cite: 46 CFR 181.450
Action required: 705 - Other - as specified
Resolved 22 August 2024
Resolution: Detectors were corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 July 2024
Resolved
Vessel was unable to restart MDEs or gen-set due to inoperable start battery. Repair/replace starting battery prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2024
Resolution: Vessel replaced all batteries on board.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 16 May 2023
Resolved
After March 24, 2019, a person may not employ or engage any individual on a national voyage that is required to hold an MMC unless that individual maintains a current medical certificate. 00 of the vessel's licensed crew members does not have evidence of a valid medical certificate. Provide evidence of valid medical certificate for the affected crew member. The affected crew member may not stand in a licensed Master or Mate position on the vessel until this deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 16 July 2025
Resolution: Legacy 835, closed out due to age
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2023
Resolved
Vessel's ring life buoy has a breached plug. Repair the plug per a manufacturer approved repair method or replace the ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 17 May 2023
Resolution: Vessel purchased a new ring buoy. Inspected as satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 May 2022
Resolved
Vessel operators required to instruct each crew member once every three (03) months as to the duties that the member is expected to perform in an emergency. Last drills were recorded in November, 2021. Operator required to conduct emergency drills with all crew members prior to them getting underway with passengers.
Action required: 10 - Deficiency Rectified
Resolved 12 May 2022
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 12 May 2022
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. No flamescreen was installed on the vent pipe end from the fuel tank on the port side. Must repair to satisfaction of USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 13 May 2022
Resolution: Def rectified onsite...[name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2021
Resolved
Fuel clamps required on all flex fuel lines in engine space.
Action required: 10 - Deficiency Rectified
Due 4 June 2021
Resolved 4 June 2021
Resolution: Installed clamps fuel line clamps on all flex fuel lines in engine space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 June 2021
Resolved
Voltmeter/Ammeter must be properly working for the ship service generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2021
Resolved 16 May 2023
Resolution: New Voltmeter/ammeter installed and inspected.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 April 2021
Resolved
Vessel's COI expires on 12APR21 and has not completed a COI renewal inspection. Vessel is restricted from carrying passengers until successful completion of COI inspection.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 June 2021
Resolution: Completed COI renewal, issued new COI.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 7 October 2019
Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously.
Action required: 10 - Deficiency Rectified
Due 7 October 2019
Resolved 7 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 7 January 2020
Resolved 16 June 2020
Resolution: Verified by [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2019
Resolved
All vessel electrical switchboards must be compliant with marine safety standards. It was discovered that there is exposed wiring going into the panel box and there openings that need to be blanked off. Must make corrections to the satisfaction of the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 1 November 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2018
Resolved
Install pre-engineered fixed fire extinguishing bottle in the E/R and prove proper operation
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2018
Resolved
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2018
Resolved 24 May 2018
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 May 2018
Resolved
Properly secure ladder leading to upper deck
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2018
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 15 May 2018
Resolved
Provide EPIRB Hydrostatic release
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2018
Resolved
Replace electric cord for cooler
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 16 May 2018
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 May 2018
Resolved
Renew fuel line suction on port and starboard mde
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 17 May 2018
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 May 2018
Resolved
Prove proper operation on E/R ventilation dampners.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 16 May 2018
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 June 2017
Resolved
Install covers or guards on rotating machinery; galley exhaust fan pulley, water maker pump.
Condition: Improper Installation
Due 7 July 2017
Resolved 24 July 2017
Resolution: Covers and guards installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 June 2017
Resolved
Cover battery terminals under pilothouse console
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 24 July 2017
Resolution: Battery terminals under pilothouse console are covered.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 7 June 2017
Resolved
Properly label diesel fuel fill caps.
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 24 July 2017
Resolution: Properly labeled.
Construction/Loadline › Hull › Stiffener
Issued 30 January 2017
Resolved
Make repairs to transum as planned with thru bolts and backing plates.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 30 March 2017
Resolution: Witnessed satisfactory installation of transom stiffeners. Stiffeners are installed with through bolts through the transom. All work was sealed with 5200.
Engineering › Bilge Water Management System › Pump
Issued 15 May 2014
Resolved
Prove proper operation of fixed bilge pump. Prior to carrying passengers
Action required: 705 - Other - as specified
Due 15 June 2014
Resolved 5 June 2014
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 May 2014
Resolved
Prove proper operation of starboard remote fuel shut off valve. Prior to carrying passengers
Action required: 705 - Other - as specified
Due 15 June 2014
Resolved 5 June 2014
Engineering › Fuel Oil Service System › Piping
Issued 15 May 2014
Resolved
Replace diesel fuel tank sight glass with proper heat resistant material as per 46 CFR 182.440 (a) 7
Action required: 705 - Other - as specified
Due 15 June 2014
Resolved 5 June 2014
Engineering › Lubricating Oil Service System › Hose
Issued 15 May 2014
Resolved
Replace wasted lube oil hose starboard MDE filter.
Action required: 705 - Other - as specified
Due 15 June 2014
Resolved 5 June 2014
Navigation › Piloting/Steering › Marine Charts
Issued 3 April 2008
Resolved
Update charts.
Due 17 April 2008
Resolved 4 April 2008
Communications › Radio Communications › EPIRB
Issued 3 April 2008
Resolved
Provide documentation on when EPIRB hydro release was replaced/when due to replacement. Correct prior to sailing beyond 3 miles from shore.
Due 17 April 2008
Resolved 4 April 2008
Resolution: New installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 3 April 2008
Resolved
Make all bulkhead penetrations on fwd E/R bulkhead water tight.
Due 17 April 2008
Resolved 4 April 2008
Lifesaving › Hand Flares › Expired
Issued 2 April 2007
Resolved
Provide a total of (6) hand flares.
Due 16 April 2007
Resolved 5 April 2007
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 2 April 2007
Resolved
Provide documentation of FCC acceptance of the FURUNO NX300 NAVTEX for installation on SPV's or install correct NAVTEX to meet 47CFR80.905 or vessels COI will be amended to voyages w/in 100 miles from mainland shore.
Due 16 April 2007
Resolved 5 April 2007
Resolution: Installed JRC NCR-333 NAVTEX
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 April 2007
Resolved
Provide/replace (3) adult Type-1 lifejackets. Vessel restricted to not more than 44 total persons until corrected.
Due 16 April 2007
Resolved 5 April 2007
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 2 April 2007
Resolved
Replace/provide (2) lifejacket lights.
Due 16 April 2007
Resolved 5 April 2007
Communications › Radio Communications › EPIRB
Issued 2 April 2007
Resolved
Provide documentation for EPIRB battery expiration date. Vsl restricted to NMT 3 miles from shore until corrected.
Due 16 April 2007
Resolved 5 April 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 2 April 2007
Resolved
Prove proper operation of E/R fixed fire system engine shutdowns.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2007
Resolved 5 April 2007
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Injector (fuel injection)
Issued 2 April 2007
Resolved
Repair fuel leak on generator injector line.
Due 16 April 2007
Resolved 5 April 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 2 April 2007
Resolved
Properly terminate or remove dead ended wire/cable in E/R over genset, fwd bulkhead, aft stbd bulkhead.
Due 16 April 2007
Resolved 5 April 2007
Engineering › Steering Gear System › Linkage
Issued 12 April 2006
Resolved
Provide sleeves in steering gear arms to prevent/stop excessive wear.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 14 April 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 June 2005
Resolved
Procure guard for fan in engine room, port side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 23 September 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 June 2005
Resolved
Procure cover for junction box in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 3 August 2005
Electrical › Electrical Distribution System (service)
Issued 13 April 2004
Resolved
Renew and permanently mount 12 V transformer for brine pump in lazaret. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 13 May 2004
Resolved 21 April 2004
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 11 April 2003
Resolved
Demonstrate proper operation of fixed fire fighting system in engineroom to shut down all machinery. 46CFR181.420(a)(3) LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2003
Resolved 15 April 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 11 April 2003
Resolved
Demonstrate proper operation of manual pull cable for FFS in E/R. 46CFR181.420(a)(2) LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2003
Resolved 15 April 2003
Electrical › Lighting (service)
Issued 11 April 2003
Resolved
Demonstrate proper operation of stern light LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2003
Resolved 15 April 2003
Electrical › Electrical Distribution System (service)
Issued 8 April 2002
Resolved
Install blank panels where breakers are missing. LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Due 16 April 2002
Resolved 2 May 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 8 April 2002
Resolved
Repair shut down selonoid on starb. MDE, so fixed system can secure the engine. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Due 16 April 2002
Resolved 2 May 2002
Documentation
Issued 29 August 2001
Resolved
Post all pages of COI for public viewing.
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 August 2001
Resolved
Repair all oil leaks on main engines and generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2001
Resolved 14 December 2001
Resolution: Engine gaskets replaced and leaking significantly abated.
Construction/Loadline
Issued 29 August 2001
Resolved
Demonstrate proper operation of all bilge alarms.
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Construction/Loadline
Issued 29 August 2001
Resolved
Clean all E/R bilges of oil and diesel fuel and clear all oil and fuel fromthe exterior of the engines.
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Construction/Loadline
Issued 20 July 2001
Resolved
Drydock the vessel for USCG inspection.
Condition: Unknown
Due 20 July 2001
Resolved 25 July 2001
Construction/Loadline
Issued 20 July 2001
Resolved
Make appropriate repairs to the vessel to include all areas of damage discovered during drydock, bow damage, potential prop or rudder damage, andany internal structural damage.
Condition: Unknown
Due 20 July 2001
Resolved 25 July 2001
Navigation
Issued 13 April 2001
Resolved
COMPASS BULB BURNED OUT, REPLACE AS NECESSARY.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Accommodation/Occupational Safety
Issued 13 April 2001
Resolved
PROPERLY MARK EMERGENCY EXITS " EMERGENCY EXIT DO NOT BLOCK "
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Lifesaving
Issued 13 April 2001
Resolved
MARK LIFE FLOATS WITH VESSELS NAME.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Engineering
Issued 4 April 2001
Resolved
Clean bilge port and starboard side under bunk room.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Construction/Loadline
Issued 4 April 2001
Resolved
Thru hole fittings (engine room) replace or repair as necessary to proper working order.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Engineering
Issued 4 April 2001
Resolved
Clean wood rot starboard side support beam in engine room.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Lifesaving
Issued 1 February 2001
Resolved
Provide damage control kit consisting of a mallet, various sized cone plugsand okum in a labeled container/bag. Kit is to stored in an accessible areaabove the bulkhead deck.
Condition: Unknown
Due 1 February 2001
Resolved 13 February 2001
Construction/Loadline
Issued 1 February 2001
Resolved
Provide metallic valves and penetrations for PVC traversing watertight bulkheads.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 February 2002
Resolved 19 February 2002
Engineering
Issued 21 April 2000
Resolved
Provide vent covers for engine room.
Condition: Unknown
Due 5 May 2000
Resolved 3 May 2000
Electrical
Issued 21 April 2000
Resolved
Clean oily residue from generator set.
Condition: Unknown
Due 5 May 2000
Resolved 3 May 2000
Engineering
Issued 21 April 2000
Resolved
Clean oil from bilges.
Condition: Unknown
Due 5 May 2000
Resolved 3 May 2000
Fire Fighting
Issued 21 April 2000
Resolved
Prove proper operation of generator shut down for fixed fire fighting system.
Condition: Unknown
Due 5 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 22 April 1998
Resolved
Repair and demonstrate operation of bilge high level alarms.
Condition: Unknown
Due 26 May 1998
Resolved 26 May 1998
Lifesaving
Issued 27 April 1995
Resolved
REPLACE OUTDATED EPIRB BATTERY.
Condition: Unknown
Due 2 May 1995
Resolved 2 May 1995
Construction/Loadline
Issued 5 April 1995
Resolved
ADD RESIN TO FIBERGLASS CLOTH IN FISH HOLD.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 5 April 1995
Resolved
ADD RESIN TO BULKHEAD IN STEERING ROOM.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Electrical
Issued 10 May 1994
Resolved
PROPERLY REPLACE THE DAMAGED WIRE IN THE EMERGENCY LIGHTING WIRE RUN.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Electrical
Issued 10 May 1994
Resolved
INSTALL PROPER CONNECTIONS TO THE BATTERY TERMINALS.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Accommodation/Occupational Safety
Issued 10 May 1994
Resolved
INSTALL A LOCKING DEVICE ON THE PORT MSD OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Electrical
Issued 10 May 1994
Resolved
PROPERLY LABEL THE PANEL BOARD IN THE ENGINEROOM.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Engineering
Issued 10 May 1994
Resolved
PROVE PROPER OPERATION OF THE HOT WATER SAFETY VALVE.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Engineering
Issued 10 May 1994
Resolved
REPLACE BOTH FLAME SCREENS ON BOTH FUEL VENTS.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Navigation
Issued 10 May 1994
Resolved
PROVIDE AN UP TO DATE COPY OF THE LIGHT LIST.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Electrical
Issued 10 May 1994
Resolved
PROVIDE THE PROPER WIRE CONNECTIONS ON THE BRIDGE AND REFRIGERATION COMPRESSOR
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Accommodation/Occupational Safety
Issued 22 November 1993
Resolved
REMOVE ALL MEANS OF SECURING FORWARD GEAR LOCKER DOOR WHICH WOULD PREVENT ITS BEING OPENED FROM THE INSIDE.
Condition: Unknown
Due 22 November 1993
Resolved 22 November 1993
Engineering
Issued 22 November 1993
Resolved
RE-ATTACH BONDING STRAP FOR PORT SHAFT GLAND.
Condition: Unknown
Due 22 November 1993
Resolved 22 November 1993
Navigation
Issued 22 November 1993
Resolved
PROVE PROPER OPERATION OF STARBOARD RUDDER.
Condition: Unknown
Due 22 November 1993
Resolved 22 November 1993
Construction/Loadline
Issued 22 November 1993
Resolved
RE-INSTALL METALLIC BILGE VALVE FOR FOREPEAK ADJACENT TO COLLISION BULKHEADMETALLIC FITTING.
Condition: Unknown
Due 22 November 1993
Resolved 22 November 1993
Construction/Loadline
Issued 22 November 1993
Resolved
STENCIL IN A VISIBLE LOCATION THE BILGE VALVE ADJACENT TO THE COLLISION BULKHEAD.
Condition: Unknown
Due 22 November 1993
Resolved 22 November 1993
Lifesaving
Issued 14 May 1992
Resolved
RENEW EXPIRED PFD LIGHT BATTERIES WITH BATTERIES MARKED WITH THE EXPIRATIONDATE ON THEM. UNTIL CORRECTED THE VESSEL'S ROUTE IS LIMITED TO NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE.
Condition: Unknown
Due 14 May 1992
Resolved 14 May 1992
Engineering
Issued 14 May 1992
Resolved
REPLACE ALL STAINLESS STEEL FUEL LINE WITH AN ACCEPTABLE MATERIAL.
Condition: Unknown
Due 14 May 1992
Resolved 14 May 1992
Navigation
Issued 14 May 1992
Resolved
PROVIDE PROPER NAVIGATION CHARTS OF THE AREA OF OPERATION, CURRENT LIGHT LIST, TIDE TABLES, AND RULES OF THE ROAD.
Condition: Unknown
Due 20 May 1992
Resolved 26 May 1992
Electrical
Issued 14 May 1992
Resolved
REPLACE WIRE SCREW NUTS WITH CRIMP OR PRESSURE TYPE CONNECTORS, ON ELECTRICAL WIRING, LOCATED IN THE BRIDGE.
Condition: Unknown
Due 20 May 1992
Resolved 26 May 1992
Engineering
Issued 14 May 1992
Resolved
RENEW WASTED FUEL VENT FLAME SCREEN LOCATED ON THE PORT FUEL VENT.
Condition: Unknown
Due 20 May 1992
Resolved 26 May 1992
Lifesaving
Issued 14 May 1992
Resolved
PROVIDE PROPER EPIRB ON BOARD THAT IS IN SERVICEABLE CONDITION AND MANUFACTURED IN OCTOBER 1989 OR LATER. UNTIL CORRECTED THE VESSEL'S ROUTE IS LIMITED TO NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE WITH PASSENGERS ON BOARD.
Condition: Unknown
Due 15 May 1992
Resolved 26 May 1992
Accommodation/Occupational Safety
Issued 8 November 1990
Resolved
PROVIDE A MARINE SANITATION DEVICE HOLDING TANK FOR THE TOILET WITH A CAPACITY TO HOLD THE WASTE OF THE MAX. NO. OF PASSENGERS ALLOWED ON BOARD, WHILE THE VESSEL IS OPERATING INSIDE THE U.S. TERRITORIAL WATERS AND INLANDWATERS.
Condition: Unknown
Due 8 November 1990
Resolved 8 November 1990
Electrical
Issued 17 May 1990
Resolved
PROVIDE ADDITIONAL EMERGENCY LIGHTING IN BUNK ROOM TO ILLUMINATE THE PORT SIDE AND THE BUNK ROOM STAIRS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990
Resolved
PROVIDE PROPER METALLIC CABLE SUPPORTS THROUGHOUT VESSEL.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990
Resolved
REPLACE YELLOW SJO CAABLE IN BUNK ROOM BILGE WITH COAST GUARD ACCEPTABLE CABLE.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990
Resolved
LABEL BILGE MANIFOLD VALVES.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Lifesaving
Issued 17 May 1990
Resolved
ATTACH THE WATERLIGHT AND THROW LINE AROUND THE BODY OF THE RING BUOY.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990
Resolved
REPLACE CRACKED WINDOW GLASS IN PORT FWD GALLEY WINDOW AND STBD BRIDGE WINDOW.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990
Resolved
PROPERLY MOUNT OUTLET BOX LOCATED ON CENTERLINE AFT UNDER BRIDGE CONSOLE.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990
Resolved
CLEAN GALLEY VENT SCREENS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Engineering
Issued 17 May 1990
Resolved
REPLACE FLAME SCREEN ON PORT FUEL TANK VENT.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990
Resolved
REMOVE OR PROPERLY DEAD-END UNUSED WIRES UNDER BRIDGE CONSOLE.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990
Resolved
REMOVE ORANGE EXTENSION CORD FROM STBD SIDE OF BRIDGE CONSOLE AND OUTLET EXPANSION PLUG FROM UNDER PORT SIDE OF BRIDGE CONSOLE.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Unknown
Issued 19 May 1989
Resolved
PROVIDE TIDE AND CURRENTS TABLES.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Lifesaving
Issued 23 May 1988
Resolved
REPLACE HAND HELD RED FLARES ON OR BEFORE JULY 31, 1988.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Lifesaving
Issued 23 May 1988
Resolved
REPLACE HAND HELD ORANGE FLARES ON OR BEFORE SEPTEMBER 30, 1988.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Accommodation/Occupational Safety
Issued 12 May 1986
Resolved
INSTALL ENGINE ROOM EXHAUST VENT IAW 46CFR182.20-45
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986