CARNIVAL ELATION

CARNIVAL ELATION is a 1998 passenger vessel (inspected). The Coast Guard has recorded 84 inspections since 2016, most recently in June 2026, along with 92 deficiencies and 7 operational controls.

Records from 2016 to 2026. Most recent: inspection, 4 June 2026.

Built
1998
Last inspected
4 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 June 2026
…with no type recorded27
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9118721
470010
Flag
BAHAMAS, THE
Maury page id
psix-470010

Documentation record

Tonnage as PSIX records it71909 - Convention (Subpart B), Gross Ton
71909 - Simplified, Gross Ton
47863 - Convention (Subpart B), Net Ton
6960 - Dead Weight, Ton
36266 - Displacement, Ton
44045 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT. EDDIE Commercial Fishing Vessel · MISLE 176474 · 5 October 2017 · activity 6282108

Inspection history · 84

4 June 2026 In-Service Inspection · Vessel Attendance
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8390936
30 March 2026 Deficiency Check · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8344629
16 March 2026 PSC A · COC-CVE Quarterly
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8326605
22 December 2025 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8286405
15 November 2025 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8269212
23 October 2025 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8255854
15 September 2025 COC-CVE Annual · PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8233476
13 March 2025 PSC A · COC-CVE Quarterly
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8090548
9 September 2024 COC-CVE Annual · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7999456
19 April 2024 Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7898209
1 April 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7888712
28 March 2024 COC-CVE Quarterly
Type not classified · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7885799
1 February 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7858974
1 February 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7859022
1 February 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7859290
23 September 2023 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7798871
22 September 2023 COC-CVE Annual · PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7796892
31 August 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7781640
21 August 2023 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7774955
8 June 2023 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7721472
10 April 2023 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7665719
3 April 2023 COC-CVE Quarterly · PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7660210
12 December 2022 In-Service Inspection · MARPOL Annex VI Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7607668
13 October 2022 Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7576617
3 October 2022 COC-CVE Annual · PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7567395
1 August 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7522304
25 July 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7517907
16 July 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7516264
16 May 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7457075
26 April 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7438466
24 April 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7437665
7 April 2022 COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7426270
11 December 2021 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7366313
5 October 2021 PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7274977
31 March 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7180400
3 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935065
13 February 2020 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6923301
30 January 2020 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6899190
11 January 2020 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6887074
9 January 2020 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6886339
6 January 2020 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6880488
22 July 2019 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6758157
2 July 2019 ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6733079
16 March 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6649834
10 January 2019 ISPS III Exam · COC-CVE Annual · Deficiency Check · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6607124
13 December 2018 Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6595757
8 December 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6597254
24 September 2018 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6547653
13 August 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6510555
2 August 2018 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6499364
2 July 2018 COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6458325
28 June 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6464105
23 June 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6455779
18 June 2018 In-Service Inspection · Security Breach · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6448623
26 April 2018 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6399985
3 April 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6384306
9 March 2018 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6369104
5 March 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6366321
1 March 2018 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6363386
22 January 2018 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6341553
8 January 2018 COC-CVE Annual · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6331405
21 December 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6330077
16 October 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6289321
16 October 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6294794
12 October 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6288605
7 October 2017 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6282161
5 October 2017 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6282108
17 August 2017 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6243735
29 July 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6233335
6 July 2017 ISPS III Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6199218
11 May 2017 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6144724
26 April 2017 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6139539
23 April 2017 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6131270
23 January 2017 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6075366
9 January 2017 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6067867
7 October 2016 Security Breach, Erroneous or Unverifiable
Type not classified · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6018478
24 September 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6036518
22 July 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5949533
11 July 2016 ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5932357
9 June 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5915806
7 May 2016 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5872254
28 March 2016 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5842030
28 January 2016 ISPS III Exam · Deficiency Check · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5802995
14 January 2016 COC-CVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5794935

Deficiency record · 92

04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 16 March 2026 Resolved
A means of communication shall be provided between the navigation bridge and the steering gear compartment. PSCO identified the means of communication between the port steering compartment and bridge was unrecognizable. 74SOLAS(04)II-1/29.10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2026
Resolved 9 April 2026
Resolution: Received Class Report and PSCO verified.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 March 2026 Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. PSCO identified a storage locker converted to an office in Camp Carnival kids area. 74SOLAS(81Amend)II-2/28.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2026
Resolved 9 April 2026
Resolution: Received Class Report and PSCO verified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2026 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed an energized electrical wire in the STBD Azipod compartment. PSCOs also observed open electrical wiring in Aft Emergency Mooring Station, FWD Fan Room located on deck 5, and other electrical storage lockers throughout the vessel. 74SOLAS(04)II-1/45.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2026
Resolved 9 April 2026
Resolution: Received Class Report and PSCO verified.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 March 2026 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed large amounts of combustibles and other items stored in A/C 1001 as well as other A/C spaces and electrical lockers throughout the ship. 74SOLAS(81Amend)II-2/26.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2026
Resolved 9 April 2026
Resolution: Recieved Class report and PSCO verified
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 15 November 2025 Resolved
Where the emergency source of electrical power is a generator, it shall be... started automatically upon failure of the electrical power and shall be automatically connected to the emergency switchboard. Vessel notified USCG of emergency generator breaker not able to switch on emergency genrator and transfer load. Provide USCG with open oceans plan for starting emergency generator and switching load. 74 SOLAS (20) II1/ 42.3.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2025
Resolved 22 December 2025
Resolution: Submitted Class Report attesting to effective repairs and that the EDG is operational and automatically starts.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 September 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving shall be in working order and ready for immediate use. The PSCO observed the port side rescue boat self-lowering device was entangled and not ready for immediate use. 74SOLAS(20)III/20.2
Action required: 10 - Deficiency Rectified
Resolved 15 September 2025
Resolution: Vessel untangled the self-lowering device
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 September 2025 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. The PSCO observed the low location photoluminescent was blocked by construction material on deck 03 FWD starboard side. 74SOLAS(01)II-2/41.2.4.7
Action required: 10 - Deficiency Rectified
Resolved 15 September 2025
Resolution: Crew removed the construction material
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 September 2025 Resolved
The construction of all doors and door frames in "A" Class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. The PSCO observed an A-60 FSD, #302 (Brig door), had a 1" diameter hole in the center of the door where a camera was previously installed. 74SOLAS(81 Amend)II-2/30.2
Action required: 10 - Deficiency Rectified
Resolved 15 September 2025
Resolution: Crew covered hole with steel plate and replaced fire insulation to make the door an A class division.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 15 September 2025 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Portable extinguishers which have been discharged shall be immediately recharged or replaced with an equivalent unit. The valve at fire station #284 was frozen and the valve wheel at fire station #278 was stripped. 74SOLAS(20)II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 15 September 2025
Resolution: Both valve wheels were replaced on each fire station
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 March 2025 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. PSCO found escape routes not identified with signage in areas within the casino area. 74SOLAS(01)II-2/41-2.4.7
Action required: 10 - Deficiency Rectified
Resolved 13 March 2025
Resolution: Vessel crew placed additional escape route signs in casino area.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 March 2025 Resolved
Eletrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO identified unapproved cable spliced directly into cable box preventing electrical box closure. 74SOLAS(04)II-1/40.1.3
Action required: 10 - Deficiency Rectified
Resolved 13 March 2025
Resolution: Vessel electrician removed the spliced cable from the electrical box.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 March 2025 Resolved
The minimum fire integrity of all bulkheads and decks shall be prescribed in tables 26.1 to 26.4. PSCO found missing A-60 insulation in electrical locker on deck 9 at frame 35. 74SOLAS(81 Amend)II-2/26.1
Action required: 10 - Deficiency Rectified
Resolved 13 March 2025
Resolution: Vessel crew replaced missin insulation in electrical store room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2024 Resolved
Eectrical installations shall be such that electrical services for safety will be ensured under variouis emergency conditions. Dead and exposed wiring was found not in a junction box. 74 SOLAS(04) II-1/40.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2024
Resolved 23 September 2024
Resolution: Received satisfactory class report.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 September 2024 Resolved
Escape route marking must enable passengers to idenitfy the routes of escape, and readily identify the escape exit. the signage for deck 10 starboard dining area near frame 87 was missing. 74 SOLAS(01) II-2/28.1.10
Action required: 10 - Deficiency Rectified
Due 16 September 2024
Resolved 16 September 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 September 2024 Resolved
Before the ship leaves port and at all times during the voyage, all alife-saving appliances shall be in working order and ready for immediate use. The rudder angle indicator for lifeboat #16 was found in-operable. 74 SOLAS(20)III/20.2
Action required: 10 - Deficiency Rectified
Due 16 September 2024
Resolved 16 September 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 September 2024 Resolved
In passenger shios, doors other than power-operated watertight doors, shall be so arranged that positive closure is assured in case for fire in the space, by power-operated closing arrangements or by the provision of self-closing doors capable of closing against an inclination of 3.5 opposing closure. Fire doors 1202 and 1204 were found not capable of latching. 74 SOLAS(81 Amend.)II-2/11.2.3
Action required: 10 - Deficiency Rectified
Due 16 September 2024
Resolved 16 September 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 September 2024 Resolved
Before the ship leaves port and at all times during the voyage all life-saving appliances shall be in wokring order and ready for immediate use. Starboard side engine for lifeboat #8 would not start. 74 SOLAS(97)III/20.1.1.1
Action required: 10 - Deficiency Rectified
Due 16 September 2024
Resolved 16 September 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 September 2024 Resolved
Means shall be provided to close all openings which may admit air to or allow gas to escape from a protected space. Door gasket for EDG space was found deteriorated which would allow the escape of gases from the space. 74 SOLAS(01)II-2/5.1.4
Action required: 10 - Deficiency Rectified
Due 16 September 2024
Resolved 16 September 2024
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 28 March 2024 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Deck 4 and deck 9 stairway guides were unfamiliar with passenger evacuation duties. Lifeboat coxswain for lifeboats 6 and 19 were unfamiliar with operation of lifeboat. Lifeboat 9 crew were unfamiliar with safety equipment in the lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2024
Resolved 28 March 2024
Resolution: Conducted training
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 March 2024 Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. FSD 12.09 in the spa/steam room is a primary means of escape and was unable to be opened. Until door is operating as designed, no passengers can enter the Steam Room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 21 May 2024
Resolution: Satisfactory repairs. Docs uploaded.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 March 2024 Resolved
All doors and frames in such bulkheads shall be of non-combustible materials and shall be so constructed and erected as to provide substantial fire resistance to the satisfaction of the administration. FSD 835 within the main galley had a locking mechanism removed rendering the door to no longer meet the structural fire protection requirements.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 March 2024
Resolved 28 March 2024
Resolution: Replaced lock to meet structural fire protection requirements.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 March 2024 Resolved
All doors and frames in such bulkheads shall be of non-combustible materials and shall be so constructed and erected as to provide substantial fire resistance to the satisfaction of the administration. FSD 506 had two holes in the door due to missing screws in the handle assembly, and FSD 378 has holes in the door due to a peephole being removed.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 March 2024
Resolved 28 March 2024
Resolution: Replaced missing screws and blocked peephole.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 March 2024 Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire as far as practicable equivalent to that of the divisions except that ventilation openings may be permitted in the lower portion of such doors. and such opening or openings shall not exceed 0.05 square m. When such openings is cut in a door it shall be fitted with a grill made of a non-combustible material. FSD 506 in crew stairwell wont latch.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 March 2024
Resolved 28 March 2024
Resolution: adjusted door to latch properly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 March 2024 Resolved
Only public toilets, lifts, lockers of non-combustible materials providing storage for safety equipment and open information counters may be located within the stairway enclosure boundaries. PSCO observed storage of cleaning supplies in crew stair 290 on deck 7.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 March 2024
Resolved 28 March 2024
Resolution: Removed gear from stairway.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 February 2024 Resolved
Means shall be provided whereby normal operations of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. PSCO were notified that the STBD azipod become inoperable due to a failed electrical card in the cyclo converter. provide class report to Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2024
Resolved 1 February 2024
Resolution: Received class documentation attesting to satisfactory repairs.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 September 2023 Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. PSCO observed large crate of bananas blocking exit from storage room along I-95. PSCO observed multiple large carboard boxes inside crew stairwell, forward of the main stage near fire station 239. 74 SOLAS 81 Amend II-2/28.1.2 10 c
Action required: 10 - Deficiency Rectified
Resolved 23 September 2023
Resolution: Corrected deficiency.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 September 2023 Resolved
Below the bulkhead deck two means of escape, at least one of which shall be independent of watertight doors, shall be provided from each watertight compartment or similarly restricted space or group of spaces. PSCO observed large linen bin blocking escape from pressing room within the main laundry room. 74 SOLAS 81 Amend II-2/28.1.1
Action required: 10 - Deficiency Rectified
Resolved 23 September 2023
Resolution: Removed linen from escape route.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 September 2023 Resolved
The construction of all doors and door frames in "A" class divisions,with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. PSCO observed sliding fire door did not close. 74 SOLAS 81 Amend II-2/30.2
Action required: 10 - Deficiency Rectified
Resolved 23 September 2023
Resolution: Adjusted fire door for proper closure.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 April 2023 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Coxswain for lifeboat number 19 was unfamiliar with procedures for clutching in engine. Four (04) assigned boat crew for lifeboat number 8 were unfamiliar with procedures for propulsion and emergency steering. 74SOLAS(20) III/19.2.1
Action required: 10 - Deficiency Rectified
Resolved 3 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 April 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving applicances shall be in working order and ready for immediate use. PSCO observed cracked bilge hose on lifeboat number 19. 74SOLAS(20) III/20.2
Action required: 10 - Deficiency Rectified
Resolved 3 April 2023
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 April 2023 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Three (3) stairway guides in forward passenger stairway, decks 5, 6, and 7 were unfamiliar with ship's procedures for guiding passengers to muster stations who do not have sail and sign cards in their possession. 74SOLAS(20) III/19.2.1
Action required: 10 - Deficiency Rectified
Resolved 3 April 2023
14 - Pollution Prevention › 146 - MARPOL Annex VI › Quality of fuel oil
Issued 12 December 2022 Resolved
While ships are operating within an emission control area, the Sulphur content of fuel oil used on board ships shall not exceed the following limits: .10% mm on and after 1 January 2015. On 08 December 2022, vessel notified Sector Jacksonville that several of their MGO fuel tanks were found to be contaminated with HFO. Engine exhaust is being run through vessel's approved exhaust gas scrubbing unit, however vessel's boiler exhaust does not. The vessel's incinerator exhaust also does not run through the exhaust gas scrubbing unit, but it is not being used since the incident was discovered. Vessel is continuing to burn potentially contaminated fuel in the boiler inside an Emission Control Area. MARPOL VI/14.4.3
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2022
Resolved 12 December 2022
Resolution: Class report provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 December 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board... Modifications were made to the HFO tanks to comply with MARPOL Annex VI. MGO tanks are still connected to HFO tanks via a common rail pipe. During internal transfer of HFO, ship's crew overfilled FO7 and the Overfill tank. HFO backed up into MGO tank 09, which contaminated vessel's day tank in the process. 74 SOLAS (20) I/11 MARPOL I/6.3.4
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2022
Resolved 12 December 2022
Resolution: Class report provided.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 December 2022 Resolved
The company should establish procedures to ensure the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirement which may be establish by the company. The objective nature of deficiencies 1 and 2 demonstrate the vessel is not being maintained to international standards, bringing into question the validity of the safety management certificate issued pursuant to the ISM code. An external audit is required to be submitted within 14 days. 74 SOLAS (20) IX/5 ISM A/10.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2022
Resolved 10 April 2023
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 October 2022 Resolved
Every oil fuel pipe which, if damaged, would allow oil to escape from a storage, settling or daily service tank situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCOs observed fuel oil quick closing valves 4, 5, 6, and 7 unable to be remotely closed from outside the machinery space. 74 SOLAS (97) II-2/15.2.5
Action required: 10 - Deficiency Rectified
Due 3 October 2022
Resolved 3 October 2022
Resolution: Quick closing valves were able to be closed from a safe space outside the machinery space prior to PSCO team's departure. Class was onboard and noted the issues on a class report for follow-on maintenance procedure changes.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 October 2022 Resolved
Every lifeboat shall be so arranged that an adequate view forward, aft, and to both sides is provided from the control and steering position for safe launching and maneuvering. PSCOs observed lifeboat numbers, 5, 7, and 8 front and side windshields to be hazed over, impeding visibility. (74 SOLAS (97) III/41.7.13)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 13 October 2022
Resolution: Lifeboats Nos. 5, 7 & 18 – front and side windshields now cleaned or replaced as necessary and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 October 2022 Resolved
Fire dampers shall operate automatically but shall also be capable of being closed manually from both sides of the bulkhead. PSCOs observed fire damper in EDG space was unable to be fully closed. (74 SOLAS (97) 11-2/16.2 2).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 13 October 2022
Resolution: EDG room fire damper defective actuators (2) now replaced. Manual and automatic operation of fire damper now demonstrated to satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 October 2022 Resolved
All lifesaving appliances provided in this part shall be fitted with retro-reflective material where it will assist in detection and in accordance with the recommendations of the Organization. PSCOs observed retro-reflective material on the topsides of all lifeboats need replacement due to fading of material. (74 SOLAS (97) 111/30.2.7)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 13 October 2022
Resolution: Retro-reflective tape on the top of all lifeboats now replaced and found satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 October 2022 Resolved
For a period of 36 hours, emergency lighting at every muster and embarkation station and over the sides as required by regulation 111/11.4. PSCOs observed emergency lighting was not illuminated at embarkation stations for lifeboats 10, 18, and 20. (74 SOLAS (04) 11-1/42.2.1.1).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 13 October 2022
Resolution: Emergency lighting at embarkation stations for lifeboats 10, 18 & 20 now reinstated and tested to satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 April 2022 Resolved
11199- Other ( life saving) -Partially enclosed lifeboats... shall be fitted with a permanently attached foldable canopy... The canopy shall so arranged that: the occupants can escape in the event of the lifeboat capsizing. Seven lifeboats were observed to be modified whereby the canopy was secured in multiple additional locations due to damage to the attached hoop-to-frame mounting, restricting the ability to quickly open the enclosure in the event of capsizing. SOLAS 97 111/42
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 27 April 2022
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 April 2022 Resolved
-07101- Fire prevention structural integrity- The hull, superstructure, structural bulkheads, decks, and deckhouses shall be construed of steel or other equivalent material and shall be according to the integrity and insulation standards given in the tables of regulations 26 and 27. Combustibles materials, including share/expired distress signals,were found stowed in a category 10 fan space on deck 5, main vertical zone 7. SLAS 01 11-2/23.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 7 April 2022
Resolved 7 April 2022
Resolution: Removed distress signals and stored in appropriate location.
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 5 October 2021 Resolved
04104 - Emergency Systems - Alleyways, stairways and exits giving access to the muster and embarkation stations shall be lighted. The low location lighting crew corridors was not operating. SOLAS97CHIII-2/11.5
Action required: 10 - Deficiency Rectified
Due 5 October 2021
Resolved 5 October 2021
Resolution: Emergency Low-Location-Lighting was replaced and operational.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 October 2021 Resolved
07120 - Fire Safety - Below the bulkhead deck two means of escape, at least one of which shall be independent of watertight doors, shall be provided from each watertight compartment or similarly restricted space or group of spaces. PSCO observed means of escape in the main laundry ironing room obstructed and padlocked. SOLAS97CHII-2/28.1.1
Action required: 10 - Deficiency Rectified
Due 5 October 2021
Resolved 5 October 2021
Resolution: Removed obstructions and padlock.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 October 2021 Resolved
07101 - Fire Safety - The hull, superstructures, structural bulkheads, decks, and deckhouses shall be constructed of steel or other equivalent material and shall be according to the integrity and insulation standards given in the tables of regulation 26 and 27. Combustible materials were found stowed in a category 10 fan space. SOLAS97CHII-2/23.1
Action required: 10 - Deficiency Rectified
Due 5 October 2021
Resolved 5 October 2021
Resolution: Combustible materials were removed from fan space.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 October 2021 Resolved
The doors shall be self-closing... and shall have an approximately uniform rate of closure of no more than 40s and no less than 10s with the ship in the upright position. FSDs 1206, 326, 364, 359, & 337 did not close properly. SOLAS97CHII-2/30.4.1
Action required: 10 - Deficiency Rectified
Due 5 October 2021
Resolved 5 October 2021
Resolution: Maintenance completed to adjust closure speed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 9 January 2020 Resolved
03112 - Scuppers, inlets, and dischargees - While operating within three nautical miles from shore, discharges of graywater are prohibited unless they meet the effluent standards in 40 CFR 133.102. The vessel discharged 22 metric tons of graywater while in-port (within 3 nautical miles) through their ballast water line. 33 USC § 1251
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 9 January 2020
Resolved 9 January 2020
Resolution: Vessel rectified graywater discharge as soon as it was found.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 January 2020 Resolved
11118 - Life Saving Appliances - On passenger ships each lifejacket shall be fitted with a light complying with the requirements of paragraph 2.2.3. of Code. PSCO's observed numerous inoperable lifejacket lights not activating, but within expiration date of the manufacturer. Vessel is to conduct 100% accountability for all lifejacket lights prior to next US port. Vessel is to identify operational status of all lifejacket lights and develop a plan to fix all lights. SOLAS14CHIII/22.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 January 2020
Resolution: Class issued documentation attesting to the replaced lifejacket lights. See attached LR document.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 January 2020 Resolved
09209 - Working and Living Conditions - Electrical installation shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO's observed an open live circuit board in the pool pump room on Deck 09. PSCO's observed broken latch on panel door located in electrical locker 3-258. SOLAS97CHII-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 January 2020
Resolution: Panel was replaced and installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 January 2020 Resolved
09209 - Working and Living Conditions - Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Junction box 9621 CC JB 202 in forward crew stairwell found broken, free from mount, and hanging loosely. SOLAS04CHII-1/45.5.5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 January 2020
Resolution: Junction box was reinstalled.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 January 2020 Resolved
07199 - Fire Safety - Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage, settling or daily service tank situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. Valve to HFO suction to booster unit for ME 3-4 did not close during remote activation. SOLAS97CHII-2/15.2.5
Action required: 10 - Deficiency Rectified
Resolved 6 January 2020
Resolution: Vessel was able to rectify faulty valve and show proper operation.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 6 January 2020 Resolved
07104 - Fire Safety - Fire doors in main vertical zone bulkheads designed to reopen upon contacting an object in its path shall reopen sufficiently to allow clear passage. FSD 917. SOLASII-2/30.4.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 January 2020
Resolved 27 January 2020
Resolution: Vessel provided class documentation attesting to the proper repair and proper functioning of FSD917.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 6 January 2020 Resolved
07104 - Fire Safety - The doors shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure, and shall have an approximately uniform rate of closure of no more than 40s and no less than 10s with the ship in the upright position. The following FSD's did not close in the appropriate time. FSD 339, FSD 818, FSD 848, FSD 911, FSD 912, FSD 913, FSD 1004, FSD 1109 SOLAS97CHII-2/30
Action required: 10 - Deficiency Rectified
Resolved 6 January 2020
Resolution: Fire Doors were properly adjusted to meet the closing time requirements.
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 6 January 2020 Resolved
04104 - Emergency Systems - In addition to the emergency lighting required by regulations II-1/42 and III/11.5, the means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators. Several sections of photoluminescent strips were inoperable. Several sections were found in the Lido galley passage way on deck 10. SOLAS97CHII-2/28.1.10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 January 2020
Resolution: Emergency Low-Location-Lighting was replaced and operational.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 January 2020 Resolved
02105 - Structural Conditions - The steering gear compartments shall be arranged for suitable working conditions in the event of hydraulic fluid leakage. Excess hydraulic fluid was observed around the steering pumps, piping, and both azipods. SOLAS04CHII-1/29.13.2
Action required: 10 - Deficiency Rectified
Resolved 6 January 2020
Resolution: Spaces containing excess hydraulic fluid were throughly cleaned to meet the requirement.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 January 2020 Resolved
07105 - Fire Safety - Doors and door frames in "B" class divisions shall have resistance to fire equivalent to that of the divisions. "B-15" door in electrical locker 3-258 had wastage and would not prevent the passage of flame and smoke. SOLAS97CHII-2/31.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 January 2020
Resolution: USCG attended vessel and witnessed satisfactory repair of door 3-258.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 July 2019 Resolved
11129 - LIFE SAVING APPLIANCES - BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCO's OBSERVED LIFEBOAT #18's PROPELLER WOULD NOT ENGAGE AND COULD NOT BE CLUTCHED IN AHEAD OR ASTERN. 74 SOLAS 1997 CON. III/19.2 - 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 July 2019
Resolved 8 July 2019
Resolution: Linkage was adjusted and problem was resolved.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 July 2019 Resolved
07105 - FIRE SAFETY - FIRE DOORS IN MAIN VERTICAL ZONE BULKHEADS AND STAIRWAY ENCLOSURES SHALL BE DESIGNED TO RE-OPEN UPON CONTACTING AN OBJECT IN ITS PATH AND SHALL RE-OPEN SUFFICIENTLY. PSCO's OBSERVED THAT FSD # 1004 DID NOT RE-OPEN WHEN THE CRASH BAR WAS ACTIVATED. 74 SOLAS 1997 CON. II-2/30.4.2 - 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 22 July 2019
Resolution: Vessel adjusted door to meet the regulations. Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 July 2019 Resolved
07105 - FIRE SAFETY - FIRE DOORS IN MAIN VERTICAL ZONES AND STAIRWAY ENCLOSURES SHALL BE SELF-CLOSING. PSCO's OBSERVED THAT FSD# 231 & 391 WOULD NOT PROPERLY CLOSE. 74 SOLAS 1997 CON. II-2/30.4.1 - 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 July 2019
Resolved 8 July 2019
Resolution: VESSEL'S CREW WAS ABLE TO PROPERLY ADJUST DOOR TO PROPERLY CLOSE AND LATCH.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 July 2019 Resolved
04103 - EMERGENCY SYSTEMS - EMERGENCY LIGHTING IN ALL SERVICE AND ACCOMMODATION ALLEYWAYS, STAIRWAYS, AND EXITS SHALL PROVIDE LIGHT FOR A PERIOD OF 36 HRS. PSCO OBSERVED NUMEROUS EMERGENCY LIGHTS INOPERABLE OR NOT CONNECTED, DUE TO INCOMPATIBLE CONNECTORS AND INOPERABLE LED DRIVERS. 74 SOLAS 2004 CON. II-1/42.2.1.3 - 50a,c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 22 July 2019
Resolution: Vessel repaired and replaced faulty lighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2019 Resolved
13199 - MAINTENANCE OF CONDITIONS AFTER SURVEY - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO ENSURE THAT THE SHIP WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO SHIP OR PERSONS ON BOARD. PSCO OBSERVED LUBE OIL PURIFIER #1, 2, 3, & 5 WITH TEMP. REPAIRS MADE WITH PERMATEX. 74 SOLAS 2004 CON. I/11(a) - 16a,c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 22 July 2019
Resolution: Vessel replaced gaskets and PSCOs verified purifiers were not leaking. Deficiency rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2019 Resolved
13199 - PROPULSION AND AUX MACHINERY - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO ENSURE THAT THE SHIP WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO SHIP OR PERSONS ONBOARD. PSCO OBSERVED DG# 2 WITH EXCESSIVE OIL LEAKS. 74 SOLAS 2004 CON. I/11 (a). - 16a,c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 22 July 2019
Resolution: PSCOs verified leaks were secured. Deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 10 January 2019 Resolved
Rescue boat shall be stowed in a state of continuous readiness for launching within 5 minutes. Port Rescue boat would not start. Form P issued by class designating #8 lifeboat as the temporary rescue boat. 74SOLAS(97) III/14.1. 50ac.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2019
Resolved 28 January 2019
Resolution: Wintessed satisfactory test of the port rescue boat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2019 Resolved
The machinery and associated piping shall be of a design and construction adequate for the service for which they are intended. The #1 ship service generator was found to have excessive fuel oil leaking. 74SOLAS(04) II-1/26.1. 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2019
Resolved 28 January 2019
Resolution: Verified #1 SSG was free of excessive oil leakage.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 January 2019 Resolved
Doorways and corridors and immediate landings in means of escape shall be sized in the same manner as stairways. Crew property was being stowed ina fashion that blocked escape doorways in vicinity of fire screen door 348. 74SOLAS(97) II-2/28.5.3. 16ac.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2019
Resolved 28 January 2019
Resolution: Verified FSD 348 was no longer blocked.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 10 January 2019 Resolved
Every member with assigned emergency duties shall be familiar with these duties before the voyage. Several crew members lacked the minimum knowledge necessary to assist passengers in evacuation. 74SOLAS(14) III/19.2.1. 16ac.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2019
Resolved 28 January 2019
Resolution: Conducted satisfactory crew knowledge test of all three passenger stairwells and lifeboat technical crews.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 January 2019 Resolved
Fire protection systems shall be in good working order so as to ensure the required performance if a fire occurs, including fire resistant dicisions and protection of openings and penetrations. Fire doors 364, 822, 921, and 1018 did not close properly. 74SOLAS(14) II-2/14.2.1.1.1.
Action required: 10 - Deficiency Rectified
Resolved 10 January 2019
Resolution: Crew fixed all fire doors noted to be malfunctioning.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 January 2019 Resolved
The Condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship will remain fit to proceed to sea without dangers to tpersons on board. The exit passageway for the engine room in the vicinity of fire screen doow 348 is partially blocked by storage shelving. 74SOLAS(14) I/11(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2019
Resolved 28 January 2019
Resolution: Storage shelving in the vicinity of FSD 348 was modified to ensure consistent passageway space througout the area.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 2 August 2018 Resolved
Ships, when engaged on international voyages, shall be fitted with a voyage data recorded (VDR). VDR is non-operational. 74SOLAS(2014 Cons.) V/20.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2018
Resolution: Received tech report that stated repairs were made to VDR and operational test was conducted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 July 2018 Resolved
0720 (Firefighting Equipment) - The condition of the ship and its equipment shall be maintained to conform with the present regulations to ensure the ship will remain without danger to the ship. A soft patch was discovered on the firemain topping off pump discharge line in the overhead of pump room #3. 74 SOLAS (01) I/11, 16ac
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Resolution: Attended vessel and cleared.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 July 2018 Resolved
0800 (Accident prevention) - Fire doors designed to reopen upon contacting an object in its path shall reopen not more than 1 meter from the point of contact. Sliding fire door #917 did not automatically re-open once the safety bar was engaged. 74 SOLAS (01) II-2/30.4.11, 16ac
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Resolution: Attended vessel and cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 2 July 2018 Resolved
0610 (lifeboats) - All lifeboat tillers shall be capable of controlling the rudder in case of failure of the steering mechanism. It was discovered the emergency tiller was inoperable on lifeboats: #12, #14, and #17. 74 SOLAS (97) III/41.7.2, 16ac
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2018
Resolution: Attended vessel and cleared.
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 January 2018 Resolved
Bilge wells in periodically unattended machinery spaces shall be monitored in such a way that the accumulation of liquids is detected. A bilge alarm located port side in the A/C compressor room is not operational. 74 SOLAS (2004 CONS.) II-I/48.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 9 January 2018
Resolution: Vessel mitigated this deficiency by keeping an oiler in the space on watch while the alarm was repaired. Proof of operation was submitted to attending inspectors. Alarm is operating as intended.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 January 2018 Resolved
Fire protection systems shall be in good working order so as to ensure the required performance if a fire occurs; Structural fire protection, includind fire-resistant divisions and protection of openings and penetrations. Fire Doors 1403 did not closed properly, sliding fire doors: 819,822 and 843 did not automatically re open once the safety bar was engaged. 74 SOLAS (2014 Cons.) II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 26 April 2018
Resolution: Attended vessel and witnessed operation of fire door closure, work properly.
Electrical › Electrical Distribution System (service) › Cable
Issued 8 January 2018 Resolved
All electrical apparatus shall be constructed and so installed as to not cause injury while handled or touched in a normal manner. Examiners found an exposed wire on the open deck adjacent to Lifeboat #4. 74 SOLAS (04 Cons) II-I/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 29 January 2018
Resolution: Vessel attached new light and verified by marine inspector.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 8 January 2018 Resolved
There must be no sewage or sewage treatment chemicals remaining on any surface. Two soft patches were found on the exterior side wall of MSD Tank #3. 33 CFR 159.121.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 15 February 2018
Resolution: Class report attesting to repairs made to MSD Tank #3.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 8 January 2018 Resolved
After any survey of the ship has been completed, no change shall be made in the structural arrangments, machinery, or equipment without the sanction of the administration. Multiple soft patches were found on piping in way of the gray water tank. 74 SOLAS (2014 Cons.) I/11(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 1 February 2018
Resolution: Gray water piping was cut out and replaced to the satisfaction of attending marine inspector.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 8 January 2018 Resolved
Structural fire protection and protection of openings and penetrations shall be kept in good working order as to ensure required performance if a fire occurs. The fire dampers located in the emergency generator room did not close properly. 74 SOLAS (2014 Cons) II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 1 February 2018
Resolution: Fire dampners close 100%
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 8 January 2018 Resolved
Structural fire protection shall be kept in good working order so as to ensure their required performance if a fire occurs. Structural fire protection located in the Emergency generator room is missing and needs to be replaced. 74 SOLAS (2014 Cons) II-2/14.2.1.1.1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 22 January 2018
Resolution: Structural fire protection replaced to the satisfaction of Class and Coast Guard.
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 8 January 2018 Resolved
The Master, Owner, Operator, or person in charge of a vessel equipped with ballast tanks must submit request for approval of Ballast Water Management System to the Commanding Offcer Safety Marine Center.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 11 January 2018
Resolution: Recieved Coast Guard Approval letter for BWMS Extension. Letter is saved in Documents tab.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 6 July 2017 Resolved
Doors in A class division shall provide resistance to fire as well as to the passage of smoke and flame. PSCO identified Class III WTDs 2 through 6 on deck 0 are admitting air,gaskets and/or doors will need to be adjusted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 17 August 2017
Resolution: Doors examined by FPVE's and LR Surveyor. Door manufacturer to attend in dry-dock scheduled Sept 2017.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 July 2017 Resolved
Oil filtering equip shall be provided w/ alarm arrangement to indicate when oil content not exceeding 15ppm can't be maintained. Crew could not demonstrate proper operation of alarm on Turner Designs Hydrocarbon Instruments OWS. Ship's crew is prohibited from the usage of this OWS until proper op is demonstrated & the IOPP certificate form A must be amended to reflect a max thruput of 2.0 m3/h.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 July 2017
Resolved 10 July 2017
Resolution: Total Marine Solutions technician was onboard to prove proper operation of O.W.S OCM and ensure crew was properly trained as per manufacturer's instructions.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 6 July 2017 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handling. The electrical junction box in way of deck 8 overhead (near emergency generator access) is wasted and has exposed wiring causing an unsafe condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 10 July 2017
Resolution: Ship's crew removed wasted junction box and was relocated closer to exterior bulkhead IWO emergency generator door.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 26 April 2017 Resolved
Vessel failed to submit updated ANOA with new ETA to place of destination. Arranged for pilot time outside of 6 hour window.
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 26 April 2017
Resolution: VSL submitted request for waiver. Granted.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 January 2017 Resolved
Fire doors and watertight doors shall be self closing and be able to maintain structural integrity. PSCO found several fire doors and watertight doors allowing the passage of air which requires adjustment to maintain structural soundness.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Received class report attesting to rectification of deficiency
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 January 2017 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea. PSCO found in way of deck drains to be wasted. Additionally on air p?ing on Lido deck portside aft is wasted beyond repair and leaking, and railing in way of lifeboat #18 is completely wasted creating a safety issue for passenger and crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Received class report attesting to rectification of deficiency
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 11 July 2016 Resolved
Every steam system shall be designed, constructed and installed to withstand the maximum working stress. The #2 AUX Boiler Overboard blowdown discharge piping has a soft patch installed and is actively leaking, outboard of the skin valve.74 SOLAS (04) II-I/33.1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2016
Resolved 22 July 2016
Resolution: Vessel was given a condition of class to AUG2016. Refer to attached class report for further information.
Engineering › Steering Gear System › Feedback Unit
Issued 11 July 2016 Resolved
All the steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the administration. Port Side #4 steering gear displayed random surging from O to 35 degrees during operational test. 74 SOLAS (04) II-1/29.2.1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2016
Resolved 22 July 2016
Resolution: Receive class report stating no unusual operation of the steering gear was observed. Nothing further is required. Refer to attached class report for further information.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 11 July 2016 Resolved
There must be no sewage or sewage treatment chemicals remaining on any surface. #2 MSD Tank is leaking from the topside inspection cover and from the #2 sewage pump. 33 CFR 159.121
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2016
Resolved 22 July 2016
Resolution: Receive class report attesting to the repairs being made. Refer to attached report for further information.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 11 July 2016 Resolved
After any survey of the ship has been completed, no change shall be made in the structural arrangements, machinery, equipment, without the sanction of the administration. Multiple pipe patches found on potable water, grey water, black water, and sewage vent piping. 74 SOLAS (14) I/11.b
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 22 July 2016
Resolution: Receive class report attesting to the repairs being made. Refer to attached report for further information.
Fire Fighting › Means of Escape › Doorways
Issued 11 July 2016 Resolved
Above the bulkhead deck there shall be atleast two means of escape from any service accomadation, and or restricted space, provide detailed description of egress route in way of galley deep fat fryer or provide alternative arrangments. 74 SOLAS (97) II-2/28.1.2
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 22 July 2016
Resolution: Received class report stating that the owners provided a fire blanket to assist in emergency egress. Refer to attached class report for furthe information.
Lifesaving › Inflatable Liferafts › Painter
Issued 14 January 2016 Resolved
0628-Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed 04 liferafts with the painter fastened to the hydrostatic release incorrectly. 74 SOLAS(a) III/20
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 14 January 2016
Resolution: Vessels crew properly set up hydrostatic releases with the release painter going thru the red week link.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 14 January 2016 Resolved
The approximate time of closure for hinged doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. PSCO observed multiple fire screen doors closing in a 4-6 second time frame. SOLAS II-2 / 30.4.1.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 January 2016
Resolved 25 January 2016
Resolution: PSC NOLA received statement from Master and a Passenger Ship Safety Certificate issued by Lloyd's Register on 23JAN16 satisfying the deficiency had been rectified.