Records from 1998 to 2026. Most recent: inspection, 14 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 38
14 April 2026
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8343591
24 April 2025
Annual Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8103807
30 October 2024
Internal Structural Exam · Hull Examination · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8027360
7 August 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7942928
18 July 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7747540
25 May 2023
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7696376
7 July 2022
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7500046
13 April 2021
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7174447
29 April 2020
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6945728
12 December 2019
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6874542
17 June 2019
Annual Survey
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6717635
5 June 2018
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6435657
12 December 2017
Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6334125
24 May 2017
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6154548
6 June 2016
Type not recorded
No type recorded · USCGC CYPRESS (WLB 210) · USCG Heartland District (CGD-H) · Activity 5900238
8 April 2016
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5850121
9 November 2015
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5756479
5 March 2014
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4884097
7 May 2012
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4304904
1 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4200331
14 July 2009
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3534121
28 August 2008
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3311328
12 July 2008
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3302954
8 May 2008
Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3204899
4 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2922206
28 March 2007
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2900258
13 April 2006
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2626775
4 April 2006
Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2626746
27 July 2005
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2442718
4 June 2004
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2095328
20 May 2004
Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2085337
24 June 2003
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1834032
13 May 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 772614
6 April 2001
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1382356
4 April 2000
Hull Examination · Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1468964
12 April 1999
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1384108
14 May 1998
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 791016
17 April 1998
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364655
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 14 April 2026
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Vessels forward engine room access ladder is unsafe for use due to broken weld. Use aft access ladder until repaired.
46 CFR 177.100
Action required: 705 - Other - as specified
Resolved 20 April 2026
Resolution: MI reviewed proof of deficiency rectification.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2026
Resolved
At each initial inspection for certification of a vessel the owner or operator shall have the vessel ready for inspection all machinery essential to the routine operation of the vessel. MI found the emergency fuel shut off not properly secured. Repair within 5 days.
46 CFR 176.804 (c)
Action required: 705 - Other - as specified
Resolved 20 April 2026
Resolution: MI reviewed proof of deficiency rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2026
Resolved
Life ring grab line
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI found the life ring buoy grab line unserviceable.
46 CFR 176.808 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 6 May 2026
Resolution: MI reviewed photos of repair.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 April 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Life float paint unserviceable.
46 CFR 176.808 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 6 May 2026
Resolution: MI reviewed photos of repair.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 April 2026
Resolved
5. LF grab line
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. MI found the life float grab lines unserviceable due to paint and frayed lines.
46 CFR 180.175 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 6 May 2026
Resolution: MI reviewed photos of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 April 2026
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. MI found the port positive MDE battery bank and SSDG positive battery terminals unserviceable.
46 CFR 177.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 20 April 2026
Resolution: MI reviewed proof of deficiency rectification.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 April 2026
Resolved
A hatch exposed to the weather must be watertight. MI found five hatches unserviceable. Reduce route to LBS.
46 CFR 179.360 (a)
Action required: 705 - Other - as specified
Resolved 22 April 2026
Resolution: MI received proof of def rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 April 2026
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. MI found 19 life jackets with unserviceable retro reflective material.
46 CFR 185.604 (h)
IMO RESOLUTION A.658(16) (5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 20 April 2026
Resolution: MI reviewed proof of deficiency rectification.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 April 2026
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. MI found jagged edges on the aft deck lights.
46 CFR 177.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 20 April 2026
Resolution: MI reviewed proof of deficiency rectification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 April 2026
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). MI found the hand pump could not reach each space and dewater the vessel. Reduce route to LBS.
46 CFR 182.520 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 20 April 2026
Resolution: MI reviewed proof of deficiency rectification.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 April 2026
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. MI found the port side main access door in an unsafe condition for passengers.
46 CFR 177.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 20 April 2026
Resolution: MI reviewed proof of deficiency rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 April 2026
Resolved
Life oats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers. MI found three life floats stacked without spacers.
46 CFR 180.137 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 6 May 2026
Resolution: MI reviewed photos of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 April 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed fire hazards must be corrected. MI observed oil leak from stbd main engine oil filter return line. Repair/Replace within 1 week.
*While underway crew will monitor and wipe up any excess oil when vessel anchors to fish.
Action required: 705 - Other - as specified
Due 1 May 2025
Resolved 30 April 2025
Resolution: MI observed brand new hose installed, no deficiency identified.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 24 April 2025
Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. MI observed expired battery in stbd most life float light. Replace.
Action required: 705 - Other - as specified
Due 8 May 2025
Resolved 30 April 2025
Resolution: MI observed brand new battery installed, no deficiency identified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2025
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). MI observed only one means of de-watering. Procure 1x portable hand bilge pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 5 May 2025
Resolution: Vessel rep supplied satisfactory evidence of new hand bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2025
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters. MI observed no label. Label.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 30 April 2025
Resolution: MI observed brand new label, no deficiency identified.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to:(b)Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment. MI observed melted lighting fixtures in engine room and melted wiring. Replace or remove.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2025
Resolved 30 April 2025
Resolution: MI observed all burnt wiring removed, no deficiency identified.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 24 April 2025
Resolved
A vessel must comply with the applicable design, equipment, personnel procedures, and record requirements of 33CFR151, 155, and 156. 33CFR151.57 requires a Garbage management Plan. MI observed no plan posted. Create and post.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 30 April 2025
Resolution: MI observed plan posted, no deficiency identified.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 August 2024
Resolved
Each survival craft required on a vessel by this part must meet approval series 160.027. Marine Inspector was unable to see data plate stating capacity of each life float. Prove existing data plate or renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2024
Resolved 20 August 2024
Resolution: MI attended vessel and inspected deficiency rectification. All sat.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 7 August 2024
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station must carry a radio operator who holds a marine radio operator permit and have the system inspected by an FCC licensed technician. Marine Inspector was informed by Captain that they did not have either. Procure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2024
Resolved 20 August 2024
Resolution: MI attended vessel and inspected deficiency rectification. All sat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 7 August 2024
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removal flame screens. Marine Inspector found one missing. Procure and install.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2024
Resolved 20 August 2024
Resolution: MI attended vessel and inspected deficiency rectification. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 August 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. Marine Inspector found lifeline to be fraying and coming apart in multiple locations. Replace. Marine Inspector found ring buoy grab line to also be fraying. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2024
Resolved 20 August 2024
Resolution: MI attended vessel and inspected deficiency rectification. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 August 2024
Resolved
Electrical equipment and installations must be suitable for the roll of the vessel underway. Marine Inspector found aft deck lights zip tied in place and not mounted appropriately. Mount correctly. Electrical equipment on a vessel must protect the vessel from electrical hazards. Marine Inspector found dead end wires under the console on the bridge and in the engine room. Fix.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2024
Resolved 20 August 2024
Resolution: MI attended vessel and inspected deficiency rectification. All sat.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 7 August 2024
Resolved
Each vessel must be equipped with a public address system. Marine Inspector found system to not be audible during the man overboard drill as Captain and deckhand were not able to use it to communicate. Fix. Vessel is not allowed to operate with only 1 master and 1 deckhand.
Action required: 705 - Other - as specified
Resolved 20 August 2024
Resolution: MI attended vessel and inspected deficiency rectification. All sat.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 June 2018
Resolved
Retro present on 08 PFDs is worn, apply retro on 08 PFDs where indicated.
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 6 June 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2018
Resolved
Twist caps found on generator wires; replace twist caps with suitable wire connectors.
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 6 June 2018
Communications › Alarms/Indicators › High Water Alarm
Issued 11 April 2016
Resolved
Label high level alarm pannel.
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 13 April 2016
Resolution: Alarm pannel labled.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 April 2016
Resolved
Several items expired in first aid kit. Replace expired medicine in first aid kit.
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 13 April 2016
Resolution: Operator purchased new first aid kit.
Navigation › Piloting/Steering › Marine Charts
Issued 11 April 2016
Resolved
Update or replace chart.
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 18 July 2016
Resolution: replace with new up to date charts
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 11 April 2016
Resolved
Chaffing gear needed for starboard MDE fuel hose extending from fuel filter.
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 13 April 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 April 2016
Resolved
Re-ground wire/fitting on port MDE.
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 13 April 2016
Construction/Loadline › Structures › Superstructure
Issued 11 April 2016
Resolved
Replace broken windows in passenger compartment.
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 18 July 2016
Resolution: replaced with new windows
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 8 April 2016
Resolved
Complete CPR/First aid training.
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 18 July 2016
Resolution: Conducted training and provided certficates
Electrical › Electric Supply System (service) › Cable
Issued 8 April 2016
Resolved
Replace plastic tie straps if used for support (and not for bundling) and if more than 24 inches apart.
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 13 April 2016
Construction/Loadline › Hull › Bottom Plating
Issued 9 November 2015
Resolved
Crop and renew resurface weld on starboard bow.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 December 2015
Resolved 17 November 2015
Construction/Loadline › Hull › Weld
Issued 9 November 2015
Resolved
Repair weld on starboard plate seam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2015
Resolved 17 November 2015
Construction/Loadline › Hull › Weld
Issued 9 November 2015
Resolved
Excessive porosity on port quarter weld.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2015
Resolved 17 November 2015
Construction/Loadline › Hull › Keel
Issued 9 November 2015
Resolved
Washed out welds on keel, and port/starboard chine, exposing plate seams at joint welds.
Due 9 December 2015
Resolved 30 November 2015
Accommodation/Occupational Safety › Potable Water System › General
Issued 9 November 2015
Resolved
Water pumps not mounted to the deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2015
Resolved 30 November 2015
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 9 November 2015
Resolved
Wire penetrating watertight bulkheads are not watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2015
Resolved 30 November 2015
Lifesaving › Lifefloat › Pendant
Issued 7 May 2012
Resolved
Replace dry rotted pendants on life floats.
Due 16 May 2012
Resolved 25 March 2013
Resolution: Verified corrected.
Lifesaving › Lifefloat › Netting
Issued 7 May 2012
Resolved
Repair basket on 8 person lifefloat.
Due 16 May 2012
Resolved 25 March 2013
Resolution: Verified corrected
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 December 2011
Resolved
Total persons allowed on vessel is reduced to 45. Crew manning shall comply with requirements and conditions set forth on the COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2013
Resolution: Issued stability letter addendum.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 14 July 2009
Resolved
Provide written designation denoting deckhand permanently assigned to vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 20 August 2009
Resolution: Item Cleared/Corrected.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 14 July 2009
Resolved
Renew expired CPR training/pgm for all crew mbrs with expired cards.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 20 August 2009
Resolution: Item Corrected/Completed.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 July 2009
Resolved
Replace Inop anchor light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 July 2009
Resolved 20 August 2009
Resolution: Item corrected.
Lifesaving › Lifefloat › Markings
Issued 14 July 2009
Resolved
Re-stencil all life-floats and oars/paddles.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 20 August 2009
Resolution: Item corrected/completed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 July 2009
Resolved
Repair two (2) through-hull bulkhead fittings located in mid-ship compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 20 August 2009
Resolution: Items completed/corrected.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 14 July 2009
Resolved
Repair inop (battery wasted) portable engine room emergency light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 20 August 2009
Resolution: Item corrected/completed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 12 July 2008
Resolved
Remove excess waste oil from engine room bilge.
Due 12 August 2008
Resolved 28 August 2008
Documentation › Certificates/Documents › Stability Letter
Issued 12 July 2008
Resolved
Post Stability Letter
Due 12 August 2008
Resolved 18 August 2008
Documentation › Certificates/Documents › FCC SSL
Issued 12 July 2008
Resolved
Obtain FCC Radio Telephony Certificate.
Due 12 July 2008
Resolved 28 August 2008
Engineering › Steering Gear System › Linkage
Issued 12 July 2008
Resolved
Starboard rudder linkage in steering compartment missing nuts. Fasten with double nuts or cotter pin
Due 12 July 2008
Resolved 12 August 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 July 2008
Resolved
Repair exhaust leak on port main engine.
Due 12 August 2008
Resolved 18 August 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 July 2008
Resolved
Refasten exhaust insulation
Due 12 August 2008
Resolved 18 August 2008
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 12 July 2008
Resolved
Repair emergency fuel shut-off valve.
Due 12 August 2008
Resolved 28 August 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 July 2008
Resolved
Provide copy of fixed firefighting service report to USCG Marine Inspector.
Due 12 August 2008
Resolved 28 August 2008
Engineering › Steering Gear System › Hydraulic Hose
Issued 8 May 2008
Resolved
Replace hydraulic lines & fittings for anchor winch & steering ram.
Due 8 June 2008
Resolved 18 August 2008
Engineering › Steering Gear System › Linkage
Issued 8 May 2008
Resolved
Steering linkage worn & loose. Rebuild pin seating.
Due 8 June 2008
Resolved 18 August 2008
Communications › Radio Communications › EPIRB
Issued 28 March 2007
Resolved
Service EPIRB (battery, hydo-release, registration, manual release pin)
Due 28 March 2007
Resolved 4 April 2007
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 28 March 2007
Resolved
Renew retroreflective material on 3 lifejackets.
Due 28 April 2007
Resolved 3 May 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 28 March 2007
Resolved
Prove proper operation of floating water lights on lifefloats. Also renew retroreflective material where needed.
Due 28 April 2007
Resolved 3 May 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 March 2007
Resolved
Ring buoy needs 60 ft of buoyant lifeline and name of vessel.
Due 28 March 2007
Resolved 3 May 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 March 2007
Resolved
Update expired & missing items or renew 1st Aid Kit.
Due 28 March 2007
Resolved 3 May 2007
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 28 March 2007
Resolved
Renew CPR cards.
Due 28 April 2007
Resolved 3 May 2007
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 28 March 2007
Resolved
Complete pre-employment drug testing on deckhand & show proof of enrollment in drug testing program.
Due 28 April 2007
Resolved 3 May 2007
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 28 March 2007
Resolved
Document tests and inspections of lifesaving equipment.
Due 28 April 2007
Resolved 3 May 2007
Fire Fighting › Fire Bucket › Quantity
Issued 28 March 2007
Resolved
Place three (3) 2.5 gallon capacity fire buckets on board vessel.
Due 28 March 2007
Resolved 4 April 2007
Fire Fighting › Fire Pumps › Capacity
Issued 4 June 2004
Resolved
Main fire pump pressure low. Make suitable repairs and retest.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2004
Resolved 30 June 2005
Lifesaving › Hand Flares › Expired
Issued 4 June 2004
Resolved
Replace 3 hand held red flares and 6 orange smoke signals.
Condition: Improper/Lack of Maintenance
Due 15 June 2004
Resolved 30 June 2005
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 4 June 2004
Resolved
Repair/replace vessel's horn.
Condition: Improper/Lack of Maintenance
Due 15 June 2004
Resolved 30 June 2005
Documentation › Certificates/Documents › FCC SSL
Issued 4 June 2004
Resolved
Renew or locate vessel's FCC Radio Safety Certificate.
Condition: Unknown
Due 31 August 2004
Resolved 30 June 2005
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 4 June 2004
Resolved
Fabricate hand wheel for emergency fuel cut off valve.
Condition: Improper/Lack of Maintenance
Due 15 July 2004
Resolved 30 June 2005
Communications › Audible Communications › SPD (Other)
Issued 24 June 2003
Resolved
Repair public announcement speaker in passenger accommodations.
Condition: Improper/Lack of Maintenance
Due 4 July 2003
Resolved 4 June 2004
Engineering › Bilge Water Management System › Not Operational
Issued 24 June 2003
Resolved
Repair bilge alarm light indicator.
Condition: Improper/Lack of Maintenance
Due 4 July 2003
Resolved 4 June 2004
Fire Fighting › Fire Pumps › Capacity
Issued 24 June 2003
Resolved
Adjust main fire pump and increase fire main pressure.
Condition: Improper/Lack of Maintenance
Due 4 July 2003
Resolved 4 June 2004
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 24 June 2003
Resolved
Replace the 1 damaged water light on vessel's life float. LEGACY COMPONENT DESC: water light
Condition: Improper/Lack of Maintenance
Due 4 July 2003
Resolved 4 June 2004
Lifesaving
Issued 17 April 1998
Resolved
PROVIDE DOCUMENTATION OF IMPLEMETATION OF A CHEMICAL TESTING PROGRAM AS REQUIRED BY 46 CFR PART 16 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 April 1998
Resolved 17 April 1998
Documentation
Issued 17 April 1998
Resolved
PROVIDE ON BOARD AN F.C.C. RADIO SAFETY CERTIFICATE AS REQUIRED BY 47 CFR 80.903.
Condition: Unknown
Due 17 April 1998
Resolved 17 April 1998
Lifesaving
Issued 17 April 1998
Resolved
CONDUCT ABONDON SHIP, MAN OVERBOARD, AND FIRE FIGHTING DRILLS AS REQUIRED BY 46 CFR 185.520 AND 185.524 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 April 1998
Resolved 17 April 1998