Records from 1998 to 2012. Most recent: casualty investigation, 30 September 2012.
Inspection history · 26
13 July 2012
DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4377921
15 February 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4244789
24 January 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4230614
29 March 2010
Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3689788
2 July 2009
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3521369
2 July 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3254345
2 April 2008
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3175949
18 May 2007
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2921221
13 April 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2913857
10 April 2006
Hull Examination · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2618108
10 May 2005
Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2353273
11 June 2004
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2098961
13 May 2004
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2059731
21 April 2004
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2049262
7 July 2003
Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1813579
24 May 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1622795
15 April 2002
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1602245
19 February 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1058739
12 February 2001
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1379286
20 March 2000
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1386771
14 March 2000
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 816518
23 February 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 126188
4 May 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1420185
26 February 1998
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1048875
26 February 1998
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1428918
4 February 1998
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1107490
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 13 July 2012
Resolved
Provide BI extinguisher as per COI, currently replaced with BII. IAW 46CFR176.810
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 17 August 2012
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 13 July 2012
Resolved
Mark and identify all electrical equipment in distribution panel. IAW CFR183.05-15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 17 August 2012
Resolution: Corrected.
Engineering › Bilge Water Management System › Not Installed
Issued 13 July 2012
Resolved
Provide visible & audible high level alarm, and visual indicator for auto bilge pump operation. IAW 46CFR182.530(c), 46CFR182.530.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 17 August 2012
Resolution: Corrected.
Navigation › Piloting/Steering › Marine Charts
Issued 2 July 2009
Resolved
PROVIDE UP TO DATE CHARTS FOR NAVIGATED.
Due 16 July 2009
Resolved 22 July 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 2 July 2009
Resolved
INSTALL PROPER CLIP ON REMOTE PULL CABLE ON FIXED FIRE FIGHTING BOTTLE IN THE ENGINE ROOM. HAVE BOTTLE CHECKED BY A TRAINED SERVICE TECH FOR PROPER INSTALLATION AND OPERATION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2009
Engineering › Fuel Oil Service System › Vent Pipe
Issued 2 July 2009
Resolved
REPLACE FUEL VENT PORT SIDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 July 2009
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 2 July 2009
Resolved
REINSTALL FIRE RETARDENT PANEL IN ENGINE ROOM OVERHEAD.
Due 16 July 2009
Resolved 22 July 2009
Communications › Radio Communications › EPIRB
Issued 10 April 2006
Resolved
Prior to the carriage of more than 6 passengers, replace EPIRB antenna. Antenna insulation is cracked and was warped with electrical tape.
Condition: Improper/Lack of Maintenance
Due 10 April 2006
Resolved 11 April 2006
Resolution: POC replaced antenna.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 10 April 2006
Resolved
Prior to the carriage of passengers, replace ring life buoy. Buoy was cracked in several areas exposing the internal foam.
Condition: Improper/Lack of Maintenance
Due 10 April 2006
Resolved 11 April 2006
Resolution: POC PURCHASED A NEW RING LIFE BUOY.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 April 2006
Resolved
Label amount and size of life jacket stowage areas. Vessel has "Life Jacket" Signs, but the size and amount is missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 11 April 2006
Resolution: POC STATED CORRECTED
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 10 May 2005
Resolved
PROVIDE CURRENT CHEMICAL TESTING PROGRAM OUTLINE INCLUDING EMPLOYEE ASSISTANCE PROGRAM.
Due 24 May 2005
Resolved 23 May 2005
Resolution: FAX DOCUMENATION.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 10 May 2005
Resolved
PROVIDE EMERGENCY PROCEDURES UNIQUE TO VESSEL OPERATIONS.
Due 24 May 2005
Resolved 23 May 2005
Resolution: FAX APPROVAL.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 10 May 2005
Resolved
REPLACE RETROREFLECTIVE MATERIAL ON LIFEJACKETS AS NEEDED.
Due 24 May 2005
Resolved 23 May 2005
Resolution: FAX.
Fire Fighting › Fire Bucket › Quantity
Issued 10 May 2005
Resolved
PROVIDE 3 2 1/2 GALLON FIRE BUCKETS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2005
Resolution: FAX.
Communications › Audible Communications › Horn/Whistle
Issued 10 May 2005
Resolved
PROVIDE HORN.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2005
Resolution: PORTABLE AIR HORN.
Communications › Radio Communications
Issued 13 May 2004
Resolved
RE-NEW FCC RADIOTELEPHONE SAFETY CERTIFICATE.
Due 13 June 2004
Resolved 11 June 2004
Resolution: FAX.
Engineering › Bilge Water Management System › Piping
Issued 13 May 2004
Resolved
REMOVE CHECK VALVE FROM FORWARD BILGE SYSTEM AND INSTALL POSITIVE CLOSURE DEVICE AT THROUGH HULL PRIOR TO CARRIAGE OF PASSENGERS.
Due 20 May 2004
Resolved 14 May 2004
Resolution: FAX DOCUMENTATION.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 13 May 2004
Resolved
REPAIR VENT CLOSURES IN ENGINE ROOM PRIOR TO CARRIAGE OF PASSENGERS.
Due 20 May 2004
Resolved 14 May 2004
Resolution: FAX DOCUMENTATION.
Operations/Management › Drug and Alcohol Testing
Issued 13 May 2004
Resolved
PROVIDE CHEMICAL TESTING ENR0LLMENT FOR CHARLES LOGSDON PRIOR TO HIM OPERATING AS MARINE CREW. LEGACY COMPONENT DESC: Employee Coverage
Due 13 June 2004
Resolved 20 May 2004
Resolution: FAX CONFIRMATION.
Communications › Radio Communications
Issued 13 May 2004
Resolved
PROVIDE CURRENT EPIRB REGISTRATION. LEGACY COMPONENT DESC: EPIRB
Due 13 June 2004
Resolved 11 June 2004
Resolution: FAX.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 9 June 2003
Resolved
REPAIR FIXED FIRE FIGHTING SYSTEM ENGINE SHUTDOWN PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Due 16 June 2003
Resolved 7 July 2003
Resolution: TESTED.
Communications › Radio Communications
Issued 9 June 2003
Resolved
REPALCE EPIRB BATTERY PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 16 June 2003
Resolved 7 July 2003
Resolution: WITNESSED.
Construction/Loadline › Penetrations
Issued 9 June 2003
Resolved
REAPIR ENGINE ROOM VENTILLATION COVER. LEGACY COMPONENT DESC: Ventillation Duct
Condition: Improper/Lack of Maintenance
Due 16 June 2003
Resolved 7 July 2003
Resolution: WITNESSED.
Engineering › Bilge Water Management System
Issued 9 June 2003
Resolved
INSTALL POSITIVE CLOSURE DEVICES ON BILGE DISCHARGE LINES AT THRU HULL. LEGACY COMPONENT DESC: Piping
Condition: Placed in Improper Service
Due 16 June 2003
Resolved 7 July 2003
Resolution: WITNESSED INSTALLATION.
Communications › Radio Communications
Issued 9 June 2003
Resolved
REPLACE 406 MHZ HYDROSTATIC RELEASE PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 16 June 2003
Resolved 7 July 2003
Resolution: WITNESSED.
Operations/Management › Drills/Instruction
Issued 15 April 2002
Resolved
INITIATE CREW TRAINING LOGS (ABANDON SHIP, MAN OVEROARD, FIRE, AND EPIRB TESTS) INCLUDING BRIEF DESCRIPTION OF EACH MONTHLY EXERCISE.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 24 May 2002
Resolution: INITIATED.
Communications › Radio Communications
Issued 15 April 2002
Resolved
PROPERLY REGISTER EPIRB. LEGACY COMPONENT DESC: EPIRB
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 May 2002
Resolved 24 May 2002
Resolution: APPLIED FOR, NOT YET RCVD.
Operations/Management › Drug and Alcohol Testing
Issued 15 April 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 24 May 2002
Resolution: ASAP PROGRAMS
Lifesaving
Issued 12 February 2001
Resolved
RE-NEW 406 MHZ HYDROSTATIC RELEASE.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Engineering
Issued 12 February 2001
Resolved
INSTALL FLAME BOWL ON FUEL STRAINER.
Condition: Unknown
Due 14 February 2001
Resolved 14 February 2001
Lifesaving
Issued 12 February 2001
Resolved
ENSURE PROPER REGISTRATION OF 406 MHZ EPIRB.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Documentation
Issued 4 May 1999
Resolved
PROVIDE MIS REPORT.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Lifesaving
Issued 4 May 1999
Resolved
REPLACE WATERLIGHT BATTERY.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Documentation
Issued 4 May 1999
Resolved
PROVIDE FCC RADIO SAFETY TELEPHONY CERTIFICATE, VSL RESTRICTED TO 1000FT FROM SHORE PENDING PROVISION.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Navigation
Issued 26 February 1998
Resolved
PROVIDE CHARTS AND OTHER REQUIRED NAVIGATION PUBLICATIONS PRIOR TO CARRYINGPASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998