MAURY USCG vessel records Sign in
← All vessels

SILVER LINING

SILVER LINING is a 1971 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1981, most recently in February 2026, along with 61 deficiencies and 1 operational control.

Records from 1981 to 2026. Most recent: inspection, 26 February 2026.

Built
1971
Last inspected
26 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4531
Flag
UNITED STATES
367778570
Maury page id
psix-47032

Inspections, by type

…with no type recorded10
Years with a record 43 calendar years (1981–2026)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.2 ft × 15.8 ft × 6.8 ft
Registered tonnagegross 23 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRESMONDO BOAT WORKS · PERDIDO BEACH, AL, UNITED STATES · built 1971
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 8 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4531MMSI 367778570 · active · compulsorily equipped · granted 23 March 2017, expires 23 March 2027
WTQ5587MMSI 367165880 · expired · compulsorily equipped · granted 10 February 2007, cancelled 1 July 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

26 February 2026 Vessel Attendance · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8317191
13 March 2025 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8093445
5 March 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8089021
21 February 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7868563
25 October 2023 Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7814230
6 July 2023 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7735658
27 February 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7644590
2 March 2022 COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7399937
2 December 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7361184
6 April 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7171091
12 May 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6933144
7 November 2019 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6852119
29 June 2019 Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6734494
18 June 2019 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6718588
9 April 2019 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6659915
23 October 2018 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570702
29 March 2018 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6376988
14 November 2017 Administrative Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6303448
31 January 2017 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6078649
18 February 2016 Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5815246
19 November 2015 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5765764
23 February 2012 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4249098
25 January 2011 Deficiency Check · Annual Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3925639
23 February 2010 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3676177
5 March 2009 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3440778
4 February 2009 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3401923
4 March 2008 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3155532
20 February 2007 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2888515
6 February 2007 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2867687
6 March 2006 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2599366
3 March 2005 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2302673
19 January 2005 Welding Related Inspections Qualification Testing
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2277393
15 November 2004 Damage Survey · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2255587
3 March 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2017005
25 February 2003 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1746418
21 February 2002 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1488028
22 February 2001 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1059485
29 February 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1426404
25 February 1999 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1421649
17 February 1999 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1347982
3 March 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1426039
6 March 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446522
25 February 1997 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1447706
22 February 1996 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1363527
19 September 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1414511
7 March 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1414420
8 March 1994 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1165067
12 May 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1143834
24 February 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 838790
17 September 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 956375
8 May 1992 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 953022
4 March 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 948319
13 March 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1238971
6 March 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 927538
28 February 1990 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1242972
13 September 1989 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1195617
8 March 1989 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 896400
2 March 1988 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1031144
5 March 1987 Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1020266
28 March 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 998532
16 January 1986 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1303909
2 January 1986 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1299348
13 February 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 977912
12 December 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1285406
3 February 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 975570
28 June 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277632
27 April 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1273768
29 June 1981 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967165
4 February 1981 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967452

Deficiency record · 61

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 February 2023 Resolved
Identified broken/wasted floor frame in engine room to be repaired/replaced at next Dry-dock to be conducted NLT 31DEC2023.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 29 November 2023
Resolution: Floor frame renewed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 March 2022 Resolved
Inspect fire protection equipment in accordance with 46 CFR 176.810. Pre-engineered fire system status light at operating station was extinguished.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2022
Resolved 15 March 2022
Resolution: Light operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 March 2022 Resolved
Inspect machinery in accordance with 46 CFR 176.804 Port MDE expansion tank was heavily corroded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2022
Resolution: Corrosion was removed. Tank appears sound.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 2 March 2022 Resolved
Comply with requirements of the FCC in accordance with 46 CFR 184.502. VHF DSC Radio function was not programmed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2022
Resolution: Radio programmed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 April 2021 Resolved
Vessel is currently equipped with a Buoyant apparatus vice the required life float. Properly install a life float of at least 50% total capacity.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 April 2021
Resolution: New life float installed.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 6 April 2021 Resolved
Properly install an approved MSD no later than next Drydock period.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 November 2021
Resolved 2 December 2021
Resolution: Owner instaled USCG approved MSD.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2021 Resolved
Remove electrical wire nuts or properly secure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 April 2021
Resolution: Wire nuts secured with electrical tape.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 April 2021 Resolved
Properly install machinery guards on both main engines.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 April 2021
Resolution: Properly install machinery guards on both main engines.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 6 April 2021 Resolved
Provide proof of valid alcohol test strips.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2021
Resolution: Test strips provided.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 June 2019 Resolved
Vessel experienced sheer planking damage along its port midbody aprox 6' long and 5' above the waterline. Plank seams have been temp repaired with Marine Epoxy; no water intrusion exists. Vessel is restricted to Sector Mobile's [name withheld] and authorized to continue operating with temp repairs until 30NOV19; provided the owner/operator/master immediately notifies the local OCMI upon any changes to the vessels fitness for service or water intrusion.
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 5 May 2020
Resolution: Repairs made during vessels drydock; all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 June 2019 Resolved
Owner shall contact the local OCMI and provide a repair proposal prior to drydocking and execution of repairs.
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 5 May 2020
Resolution: Repair proposal approved and all repairs were made during vessels drydock.
Documentation › Certificates/Documents › FCC SSL
Issued 29 March 2018 Resolved
Provide valid FCC station license
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 30 March 2018
Resolution: Vessel provided valid station license
Lifesaving › Lifebuoys › Serviceable
Issued 31 January 2017 Resolved
Replace the vessels Life Ring Buoy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 7 February 2017
Resolution: Witnessed
Lifesaving › Lifefloat › Serviceable
Issued 31 January 2017 Resolved
Repair the cracks in the Life FLoat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 7 February 2017
Resolution: Witnessed
Engineering › Steering Gear System › Rudder Bearing
Issued 31 January 2017 Resolved
Repack the STBD rudder post.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 7 February 2017
Resolution: Witnessed
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 February 2016 Resolved
Provide valid first aid kit
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2016
Resolved 22 February 2016
Resolution: Vessel provided first aid kit.
Engineering › Bilge Water Management System › Interface Detector
Issued 18 February 2016 Resolved
Repair/Replace engineroom bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 22 February 2016
Resolution: Vessel replaced engineroom bilge alarm.
Stability › Incline Test › General
Issued 23 February 2012 Resolved
Schedule to have an original SST conducted.
Action required: 705 - Other - as specified
Resolved 31 May 2013
Resolution: Vessel can schedule an SST. Vessel has been issued standard passenger reduction.
Lifesaving › Lifefloat › Serviceable
Issued 25 January 2011 Resolved
Repair life float cracks with [name withheld] kit.
Due 21 February 2011
Resolved 17 February 2011
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 23 February 2010 Resolved
Install new pre-engineered fixed gas fire extinguishing system as original and provide installation and servicing report from servicing fire safety company that certifies that all the requirements listed in 46CFR 181.420 have been satisfied.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2010
Resolved 25 February 2010
Resolution: Replacement FE241 Pre-Engineered system bottle Model MA21000, Serial # DB000013124 was installed by B& C Fire Safety, Inc Ft. Walton Beach, FL and found satisfactory.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 February 2010 Resolved
Update all expired/ dated contents of first aid kit that meets the requirements of 46 CFR 184.710 .
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2010
Resolved 25 February 2010
Resolution: All outdated contents of the first aid kit were renew and found satisfactory.
Construction/Loadline › Hull › Transverse Frame
Issued 4 February 2009 Resolved
Replace or sister transverse frame #2 in berthing area on port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2009
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2009 Resolved
Provide fasteners and keel bolts as identified for credit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2009
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 4 February 2009 Resolved
Replace forward and aft cutlass bearing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2009
Construction/Loadline › Penetrations › Valve Flange
Issued 4 February 2009 Resolved
Replace ball valve for sewage thru-hull penetration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2009
Construction/Loadline › Penetrations › Pipe Flange
Issued 6 February 2007 Resolved
Found stbd propulsion engine cooling water inlet through hull fitting loose with evidence of possible decay in plank. Remove fitting and all bedding material, clean and make area available for further inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 February 2007
Resolved 7 February 2007
Resolution: Area of concern cleaned and examined. No evidence of decay found in plank and hull penetration in sound condition. Through hull fitting replaced in kind.
Construction/Loadline › Penetrations › Valve Flange
Issued 6 February 2007 Resolved
Found sewage overboard gate valve frozen. Disassemble, clean and service or replace valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2007
Resolved 7 February 2007
Resolution: Valve serviced and returned to service.
Construction/Loadline › Penetrations › Valve Flange
Issued 6 February 2007 Resolved
Found forward machinery space bilge pump overboard discharge valve frozen. Replace valve in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2007
Resolved 7 February 2007
Engineering › Bilge Water Management System › Hose
Issued 6 February 2007 Resolved
Replace improper flex hose assembly on forward machinery space electric submersible bilge pump with a hose meeting 46 CFR 182.500(f)(1).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 February 2007
Resolved 7 February 2007
Construction/Loadline › Hull › Side Shell
Issued 6 February 2007 Resolved
Re-caulk plank seam, stbd side, mid-ship approx 2 ft up from keel as marked by inspector.
Action required: 705 - Other - as specified
Due 7 February 2007
Resolved 7 February 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 March 2005 Resolved
Install suitable machinery guard on stbd propulsion engine flywheel. (46 CFR 177.960)
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 7 March 2005
Engineering › Fuel Oil Service System › Hose
Issued 3 March 2005 Resolved
Replace worn or brittle fuel oil system flex hose assemblies on propulsion engines.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 7 March 2005
Lifesaving › Buoyant Apparatus › Serviceable
Issued 3 March 2005 Resolved
Properly label/mark paddles for buoyant apparatus with vessel name (46 CFR 180.200)
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 7 March 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 March 2005 Resolved
Provide a serviceable floating electric floating light approved under 46 CFR 161.010 fitted with 3 foot lanyard and corrosion resistant clip for life ring buoy as required by 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 7 March 2005
Construction/Loadline › Hull › Longitudinal Frame
Issued 15 November 2004 Resolved
Replace outboard most vertical frames (3) starboard and (3) port on stern transom.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 6 December 2004
Resolution: Replaced as original.
Construction/Loadline › Hull › Side Shell
Issued 15 November 2004 Resolved
Renew damaged stern strip planking damaged from Hurrican Ivan as marked.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 6 December 2004
Resolution: All stern strip planking were renewed.
Construction/Loadline › Hull › Side Shell
Issued 15 November 2004 Resolved
Renew damaged planks in the vicinity of bottom adjacent to stern both port and starboard.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 6 December 2004
Resolution: Renewed 2 planks port stern quarter, 3 planks stbd stern quarter and 5 planks stbd midship-fwd.
Construction/Loadline › Hull › Hull Plating
Issued 15 November 2004 Resolved
Renew fastener as required from stern, bottom and aft of midship.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 6 December 2004
Resolution: All fasteners from midship going aft on side shell and entire bottom refastened w/ 3 1/2 inch silicon bronze ring shank.
Construction/Loadline › Hull › Bracket
Issued 15 November 2004 Resolved
Renew gussets in way of frames 1-8.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 6 December 2004
Resolution: All gussets in way of frames 1-8 reinforced and bolted w/ hot dipped galvanized 3/8 bolts.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 November 2004 Resolved
Renew starboard shaft and all water lubricated bearings.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 6 December 2004
Resolution: STBD shaft replaced. All cutlass bearings replaced.
Engineering › Steering Gear System › Fastener
Issued 15 November 2004 Resolved
Renew steering componet foundations as marked.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 6 December 2004
Resolution: Renewed all wood foundation in way of steering components.
Construction/Loadline › Hull › Keel
Issued 15 November 2004 Resolved
Renew keel bolts as marked.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 6 January 2005
Resolution: Keel rebolted from stern to fwd engine room with 5/8 Stainless Steel Bolts.
Construction/Loadline › Hull › Transverse Frame
Issued 15 November 2004 Resolved
Renew or repair cracked frame 4 IWO starboard stern.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 6 December 2004
Resolution: 4th frame starboard to be sistered with like frame.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 15 November 2004 Resolved
Renew or repair fuel tank.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 6 December 2004
Resolution: Newed aluminum fuel tank purchased from RDS Manufacturing of Perry, FL. Approved by MSO Tampa.
Navigation › Piloting/Steering
Issued 11 March 2003 Resolved
Provide up to date charts and publications as required by 46 CFR 184.420/185.20-35 LEGACY COMPONENT DESC: Charts and Publications
Condition: Unknown
Due 11 April 2003
Resolved 3 March 2004
Resolution: Owner provided up to date charts and pubs.
Communications › Radio Communications
Issued 11 March 2003 Resolved
Provide Emergency Broadcast Placard as required by 46 CFR 184.506 LEGACY COMPONENT DESC: Emergency Broadcast Placard
Due 11 April 2003
Resolved 3 March 2004
Resolution: Owner provided emergency broadcast placard.
Construction/Loadline
Issued 19 September 1995 Resolved
NUMEROUS HULL REPAIRS COMPLETED DURING THIS DRYDOCK PERIOD SEE MINS CASE NOMI95034016 FOR DETAILS.
Condition: Unknown
Due 19 September 1995
Resolved 19 September 1995
Lifesaving
Issued 24 February 1993 Resolved
RELOCATE EPIRB MOUNTING BRACKET TO WEATHERDECK TO ENSURE EPIRB WILL FLOAT FREE IN AN EMERGENCY.
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Lifesaving
Issued 24 February 1993 Resolved
RENEW EPIRB BATTERY.
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Lifesaving
Issued 24 February 1993 Resolved
INSTALL -60- FEET OF LINE TO RING LIFE BUOY.
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Lifesaving
Issued 24 February 1993 Resolved
RENEW WORN RETRO REFLECTIVE MATERIAL TO ONE ADULT LIFE PRESERVER.
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Lifesaving
Issued 24 February 1993 Resolved
RENEW WORN RETRO REFLECTIVE MATERIAL TO LIFE FLOAT.
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Navigation
Issued 4 March 1992 Resolved
REMOVE ALL TINTED PILOT HOUSE WINDOW AND REPLACE WITH CLEAR GLASS.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Unknown
Issued 2 March 1988 Resolved
REMOVE PRESENT DRAIN FITTING AND PERMANENTLY SEAL OPENING IN LOWER COLLISION BULKHEAD.
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Unknown
Issued 2 March 1988 Resolved
POST ALL CERTIFICATES.
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Unknown
Issued 2 March 1988 Resolved
LOCATE AND REPAIR SOURCE OF WATER ENTERING HULL AT STEM.
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Lifesaving
Issued 13 February 1985 Resolved
PROVIDE ONBOARD 6 RED FLARES AND 6 ORANGE SMOKES. THESE MUST BE APPROVED EQUIPMENT AND WITHIN DATE.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Lifesaving
Issued 13 February 1985 Resolved
PROVIDE ONBOARD AN APPROVED OPERABLE WATER LIGHT FOR THE LIFERING.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Lifesaving
Issued 13 February 1985 Resolved
PROVIDE ONBOARD AN APPROVED PROPERLY SIZED WEAK LINK FOR THE LIFEFLOAT.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Accommodation/Occupational Safety
Issued 13 February 1985 Resolved
INSTALL DECK RAILS IN ACCORDANCE WITH 46 CFR 177.35.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Fire Fighting
Issued 13 February 1985 Resolved
RECHARGE THE B-II FIRE EXTINGUISHER WICH HAS A LOW CHARGE.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.