MAURY USCG vessel records
← All vessels

SILVER LINING

SILVER LINING is a 1971 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in February 2026, along with 17 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 26 February 2026.

Built
1971
Last inspected
26 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 February 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ4531
Flag
UNITED STATES
Maury page id
psix-47032

Documentation record

Registered dimensions (L × B × D)40.2 ft × 15.8 ft × 6.8 ft
Registered tonnagegross 23 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRESMONDO BOAT WORKS · PERDIDO BEACH, AL, UNITED STATES · built 1971
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 8 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

26 February 2026 Vessel Attendance · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8317191
13 March 2025 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8093445
5 March 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8089021
21 February 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7868563
25 October 2023 Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7814230
6 July 2023 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7735658
27 February 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7644590
2 March 2022 COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7399937
2 December 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7361184
6 April 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7171091
12 May 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6933144
7 November 2019 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6852119
29 June 2019 Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6734494
18 June 2019 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6718588
9 April 2019 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6659915
23 October 2018 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570702
29 March 2018 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6376988
14 November 2017 Administrative Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6303448
31 January 2017 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6078649
18 February 2016 Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5815246

Deficiency record · 17

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 February 2023 Resolved
Identified broken/wasted floor frame in engine room to be repaired/replaced at next Dry-dock to be conducted NLT 31DEC2023.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 29 November 2023
Resolution: Floor frame renewed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 March 2022 Resolved
Inspect fire protection equipment in accordance with 46 CFR 176.810. Pre-engineered fire system status light at operating station was extinguished.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2022
Resolved 15 March 2022
Resolution: Light operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 March 2022 Resolved
Inspect machinery in accordance with 46 CFR 176.804 Port MDE expansion tank was heavily corroded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2022
Resolution: Corrosion was removed. Tank appears sound.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 2 March 2022 Resolved
Comply with requirements of the FCC in accordance with 46 CFR 184.502. VHF DSC Radio function was not programmed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2022
Resolution: Radio programmed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 April 2021 Resolved
Vessel is currently equipped with a Buoyant apparatus vice the required life float. Properly install a life float of at least 50% total capacity.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 April 2021
Resolution: New life float installed.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 6 April 2021 Resolved
Properly install an approved MSD no later than next Drydock period.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 November 2021
Resolved 2 December 2021
Resolution: Owner instaled USCG approved MSD.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2021 Resolved
Remove electrical wire nuts or properly secure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 April 2021
Resolution: Wire nuts secured with electrical tape.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 April 2021 Resolved
Properly install machinery guards on both main engines.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 April 2021
Resolution: Properly install machinery guards on both main engines.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 6 April 2021 Resolved
Provide proof of valid alcohol test strips.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 April 2021
Resolution: Test strips provided.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 June 2019 Resolved
Vessel experienced sheer planking damage along its port midbody aprox 6' long and 5' above the waterline. Plank seams have been temp repaired with Marine Epoxy; no water intrusion exists. Vessel is restricted to Sector Mobile's [name withheld] and authorized to continue operating with temp repairs until 30NOV19; provided the owner/operator/master immediately notifies the local OCMI upon any changes to the vessels fitness for service or water intrusion.
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 5 May 2020
Resolution: Repairs made during vessels drydock; all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 June 2019 Resolved
Owner shall contact the local OCMI and provide a repair proposal prior to drydocking and execution of repairs.
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 5 May 2020
Resolution: Repair proposal approved and all repairs were made during vessels drydock.
Documentation › Certificates/Documents › FCC SSL
Issued 29 March 2018 Resolved
Provide valid FCC station license
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 30 March 2018
Resolution: Vessel provided valid station license
Lifesaving › Lifebuoys › Serviceable
Issued 31 January 2017 Resolved
Replace the vessels Life Ring Buoy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 7 February 2017
Resolution: Witnessed
Lifesaving › Lifefloat › Serviceable
Issued 31 January 2017 Resolved
Repair the cracks in the Life FLoat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 7 February 2017
Resolution: Witnessed
Engineering › Steering Gear System › Rudder Bearing
Issued 31 January 2017 Resolved
Repack the STBD rudder post.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 7 February 2017
Resolution: Witnessed
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 February 2016 Resolved
Provide valid first aid kit
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2016
Resolved 22 February 2016
Resolution: Vessel provided first aid kit.
Engineering › Bilge Water Management System › Interface Detector
Issued 18 February 2016 Resolved
Repair/Replace engineroom bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 22 February 2016
Resolution: Vessel replaced engineroom bilge alarm.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.