Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 December 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE2394
470353
Flag
UNITED STATES
Maury page id
psix-470353

Documentation record

Registered dimensions (L × B × D)38.0 ft × 11.0 ft × 3.0 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCANAL BOATS INC · FORT LAUDERDALE, FL, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portFORT LAUDERDALE, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 20 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

22 December 2025 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8283837
20 May 2025 Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8139559
25 March 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8099109
21 March 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7883651
26 September 2023 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7799157
2 February 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7629865
6 October 2022 Administrative Inspection · Simplified Stability Test
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7572979
24 January 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7384577
13 December 2021 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7367332
27 December 2020 Deficiency Check · Annual Inspection · COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7116596
8 June 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6971276
30 March 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6933058
16 December 2019 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6874350
3 April 2019 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6655064
14 March 2018 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6370100
20 December 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6326994
22 March 2017 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6109392
2 September 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5990514

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2025 Resolved
On a vessel of not more than 19.8 meters in length carrying more than 49 passengers...each hose must be lined commercial fire hose that conforms to UL 19 or hose that is listed and labeled by an independent laboratory recognized by the Commandant as being equivalent performance. A pin hole leak was discovered on the fire hose and water was leaking from the connection port of the fire hose. 46CFR181.320(B)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 9 April 2025
Resolution: Vessel crew replaced fire hose.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 March 2025 Resolved
...Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. The visual auto bilge indicator to the bilge high level alarm did not activate. 46CFR182.520
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 9 April 2025
Resolution: Vessel crew repaired bilge high level alarm and provided proof of indication light for alarm activation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 January 2021 Resolved
Flexible hose runs must be visible, easily accessible, protected from mechanical damage, and must not penetrate watertight decks or bulkheads. Ensure hoses are outfitted with metal fittings at bulkhead penetration. 46CFR182.720(e)(3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 January 2021
Resolved 21 January 2021
Resolution: All hoses installed with plate and coupling at bulkhead penetration.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 January 2021 Resolved
Each life jacket must be marked with Type 1 retroreflective material approved in 46CFR164.018. Replace retro on 16 life jackets. 46CFR185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2021
Resolved 14 January 2021
Resolution: All retro replaced.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 January 2021 Resolved
Vessel bilge alarm panel must have a light or other visual means at control station. Engn Rm high water light on panel not working. 46CFR182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2021
Resolved 14 January 2021
Resolution: High water visual indicator test sat.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 9 June 2020 Resolved
A visual and audible alarm must be provided at operating station to indicate high water level. center void bilge alarm needs to operate. 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2020
Resolved 12 June 2020
Resolution: Recieved video evidence to clear deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 June 2020 Resolved
Lifejackets must be provided for each person onboard IAW Subchapter Q. Replace retroreflective tape with SOLAS approved type. 46 CFR 180.71(c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2020
Resolved 12 June 2020
Resolution: all identified lifejackets have been refit with retro-reflective tape.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 22 March 2017 Resolved
Provide emergency broadcast placard to be posted next to radio. 46 CFR 184.506.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 22 March 2017
Resolution: Provided emergency broadcast placard near radio.
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 March 2017 Resolved
Provide visual and audible bilge high level alarm for compartment #1. 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 22 March 2017
Resolution: Provided operable visual and audible bilge high level alarm for compartment #1.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 March 2017 Resolved
Conduct successful MOB drill. 46 CFR 185.520.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 22 March 2017
Resolution: Conducted successful MOB drill.

Ownership record