← All vessels
THE ENTERPRISE
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named THE ENTERPRISE
THE ENTERPRISE is a 1997 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 1998, most recently in April 2009, along with 22 deficiencies and 1 operational control.
Records from 1998 to 2009. Most recent: inspection, 14 April 2009.
- Built
- 1997
- Last inspected
- 14 April 2009
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 22 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1063146
WCY3212
470364
Flag
UNITED STATES
367336250 (licence lapsed)
Maury page id
psix-470364
Inspections, by type
…with no type recorded1
Years with a record
9 calendar years (1998–2009)
The 19 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.4 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER BOATS INTER · FT PIERCE, FL, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHARLESTON, SC
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Net Ton
12 - Simplified, Gross Ton
12 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WCY3212MMSI 367336250 · expired · voluntarily equipped · granted 8 February 2008, cancelled 23 June 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 19
14 April 2009
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3453074
21 February 2008
Annual Inspection · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3150549
1 February 2007
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2865283
26 May 2005
Deficiency Check · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2405941
8 March 2005
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2332167
25 April 2002
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1609409
25 September 2001
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1384886
19 April 2001
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1420496
14 April 2000
Plan Review "T" Boat
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1462835
10 April 2000
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1451535
5 April 2000
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1417042
6 July 1999
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1089481
30 April 1999
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 813281
27 April 1999
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1436200
18 August 1998
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1131682
3 July 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 185086
22 April 1998
Initial Certification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1123111
20 February 1998
Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 788299
20 February 1998
Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 792225
Deficiency record · 22
Engineering › Bilge Water Management System › Valve
Issued 21 February 2008
Resolved
Install positive shutoff valves on all bilge system overboard piping.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 February 2008
Resolved
Properly repair or remove dead end wires in engine room located by engine room lighting.
Electrical › Electrical Distribution System (service) › Switch
Issued 21 February 2008
Resolved
Properly mount battery switch onto bulkhead in the engine room. Aft switch is currently being supported by the wiring.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 21 February 2008
Resolved
Found engine rooms' pre engineered fixed fire fighting system manual release valve disconnected. Ensure engine rooms' fixed fire system is maintained and working properly.
Electrical › Electric Supply System (service) › Cable
Issued 26 May 2005
Resolved
Remove dead Wiring from engine room and aft steering.
Lifesaving › Lifebuoys › Stowage
Issued 26 May 2005
Resolved
Install lifeline on lifering with clip for light
Engineering › Bilge Water Management System › Pump
Issued 26 May 2005
Resolved
Secure forward engine room bilge pump
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 May 2005
Resolved
Update light list & Coast Pilot to current year.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 25 April 2002
Resolved
Provide one B-II portable fire extinguisher.
Engineering
Issued 10 April 2000
Resolved
REPLACE FLEXIBLE FUEL HOSES IAW 46 CFR 182.720.e.1
Lifesaving
Issued 10 April 2000
Resolved
OBTAIN TWO ADDITIONAL ADULT PFD'S. UNTIL PFD'S HAVE BEEN OBTAINED, VESSEL IS LIMITED TO 22 PEOPLE ALLOWED O/B VESSEL.
Lifesaving
Issued 10 April 2000
Resolved
REPLACE BATTERY ON WATERLIGHT ATTACHED TO LIFEFLOAT.
Fire Fighting
Issued 10 April 2000
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS
Lifesaving
Issued 10 April 2000
Resolved
REPLACE 3 EXPIRED FLARES
Lifesaving
Issued 10 April 2000
Resolved
MAINTAIN A VOYAGE PLAN FOR ALL VOYAGES MADE WITH PASSENGERS
Navigation
Issued 10 April 2000
Resolved
OBTAIN CURRENT COPIES OF CG LIGHT LISTS AND US COAST PILOT
Fire Fighting
Issued 27 April 1999
Resolved
Provide servicing report for fixed fire extinguishing system.
Documentation
Issued 27 April 1999
Resolved
Obtain logbooks for bridge and training records.
Lifesaving
Issued 27 April 1999
Resolved
Paint name on ring buoy.
Lifesaving
Issued 27 April 1999
Resolved
Hang first aid kit in accesible area.
Navigation
Issued 22 April 1998
Resolved
PROVIDE 46 CFR SUBCHAPTER T.
Documentation
Issued 22 April 1998
Resolved
POST STABILITY LETTER, PERMANENT FCC STATION LICENSE AND FCC SAFETY CERTIFICATE WHEN RECEIVED. (ALL IN PROCESS).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.