Inspection history · 57
30 March 2026
COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8321052
26 June 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8168755
22 May 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7899393
1 August 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7758976
13 June 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7714312
16 August 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7536705
30 March 2021
COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7165360
7 July 2020
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7112781
11 April 2018
Administrative Inspection · Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6451689
3 May 2017
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6138240
1 May 2017
Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6136395
25 April 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6132631
2 March 2016
COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5825243
4 February 2015
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5071436
2 April 2014
Periodic Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4830724
2 May 2012
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4300351
10 February 2012
Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4242035
29 November 2011
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4197514
29 November 2010
Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3900387
26 March 2010
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3703266
31 March 2009
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3445533
10 June 2008
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3232867
16 April 2008
DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3177712
16 April 2008
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3188736
20 March 2008
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3177425
5 April 2007
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2902516
15 February 2006
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2585419
29 March 2005
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2321709
31 March 2004
Uninspected Other · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2034224
3 February 2003
Internal Structural Exam · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1738990
16 September 2002
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1676373
21 August 2001
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1403442
2 October 2000
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1415452
29 March 2000
Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 816599
3 November 1999
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1448030
27 August 1998
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1386328
24 March 1998
Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1392892
23 February 1998
Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 781703
15 October 1997
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1446544
13 November 1996
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1404268
3 October 1995
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 872408
12 October 1994
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 865733
1 April 1994
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 855969
5 November 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 848769
28 October 1993
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1142738
6 October 1993
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 963196
24 February 1993
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 840649
5 February 1993
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 826297
15 December 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1414092
11 December 1992
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 830114
6 October 1992
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1254264
26 November 1991
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1249136
28 August 1990
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 909952
12 September 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1339262
15 August 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1350681
21 August 1988
COI Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1040013
11 September 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 989068
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2025
Resolved
Equipment shall me maintained to ensure the safety of the crew. Electrical junction box missing cover. Replace cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 July 2025
Resolution: Reviewed objective evidence of corrective action.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 June 2025
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Yellow lights inoperable. Repair yellow lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2025
Resolution: Reviewed objective evidence of corrective action.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 26 June 2025
Resolved
The hull of each documented vessel must be marked as required by part 67 of this chapter. The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel name not on port and starboard side. Hailing port not marked.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2025
Resolution: Reviewed objective evidence of corrective action.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 May 2024
Resolved
Vessel required to have a fire pump. Fire pump broke during test. Repair fire pump, demonstrate proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2024
Resolution: Witnessed proper operation of bilge and fire pump
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 May 2024
Resolved
Bessel required to have bilge pump. Bilge pump not able to take suction from voids. Make repairs, demonstrate proper operation,
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2024
Resolution: Witnessed proper operation of bilge and fire pump
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 August 2023
Resolved
Fire Hose nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. Nozzle missing. Replace.
46CFR181.320(d)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2023
Resolution: Installed Nozzle
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 August 2022
Resolved
Chemical testing of personnel must be conducted as required by 46 CFR 16.201 and in accordance with the procedures detailed in 49 CFR part 40. No evidence of chemical testing provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2022
Resolved 19 August 2022
Resolution: Provided objective evidence of compliance with 46CFR16.201
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 August 2022
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Extinguishers required on a vessel must be serviced and acceptable to the cognizant Officer in Charge, Marine Inspection. No evidence of extinguisher servicing avalilable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2022
Resolved 29 August 2022
Resolution: Provided objective evidence to clear deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 16 August 2022
Resolved
vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant OCMI. Line and anchor not satisfactory for vessel and waters it operates on.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 29 August 2022
Resolution: Provided objective evidence to clear deficiency.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 April 2017
Resolved
Water light battery expiration unknown: replace batteries annually if not marked with expiration date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 1 May 2017
Resolution: Batteries replaced and date stamped on batteries and external body of light.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 April 2017
Resolved
Life jacket placards containing instructions for donning are not posted. Post in conspicuous places which are regularly accessible and visible to the crew and passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2017
Resolved 1 May 2017
Resolution: Posted life jacket placards appropriately in a conspicuous place
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 April 2017
Resolved
Ring lifebuoy, port side, has frayed grab-line, missing type II retroreflective tape, illegible vessel name. Replace or repair (new grab lines, vessels's name in block letters and Type II retroflective tape in accordance with 46CFR 164.018).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2017
Resolved 1 May 2017
Resolution: Replaced life ring
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 25 April 2017
Resolved
Nav running light - red - missing lense. Repair prior to night or limited visibility ops to specs per Inland Rules of the Road.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 1 May 2017
Resolution: replaced red nav light lense.
Fire Fighting › Fire Hoses › Connections
Issued 25 April 2017
Resolved
Female connector for pump/fire hose not available. Keep adaptor attached to pump piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 1 May 2017
Resolution: Placed new female adapter onboard.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 February 2012
Resolved
The battery for the float lights are of the spring type, but the connection clips are designed for post type batteries. Ensure correct batteries are used for float lights in accordance with manufacturers guidelines.
Action required: 705 - Other - as specified
Due 24 March 2012
Resolved 17 April 2012
Resolution: New batteries with post type connections have been installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 February 2012
Resolved
The screens for the port and starboard running lights on both ends of the vessel need a new coat of matte black paint to meet the requirements of 33 CFR 84.09 of the NAVRULS. The screens are showing a great deal of rust & will need to be sanded down and refinished prior to operating after dusk or before dawn and in conditions of restricted visibility.
Action required: 705 - Other - as specified
Due 24 March 2012
Resolved 17 April 2012
Resolution: All four screens for the running lights on both ends of the vessel have been replaced with new screens painted in matte black.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 February 2012
Resolved
The float light for the ring buoy was connected directly to the becket of the ring buoy with a clip. The waterlight must have a lanyard of at least 3 feet in length but no more than 6 feet that secures the waterlight to the buoy with a corrosion-resistant clip that can be quickly disconnected from the ring buoy.
Action required: 705 - Other - as specified
Due 24 March 2012
Resolved 17 April 2012
Resolution: The waterlight is connected to the ring buoy via a lanyard of appropriate length and has a corrosion-resistant clip for quick disconnection.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 March 2010
Resolved
Navigation lights on passenger barge are not working properly. Prior to operating at night or in conditions of low visibility, provide proof of proper operation of navigation lights to the satisfaction of the U.S. Coast Guard.
Action required: 705 - Other - as specified
Resolved 1 December 2010
Resolution: All navigational lights were tested and are operational.
Communications › Audible Communications › Horn/Whistle
Issued 2 April 2009
Resolved
Tug's whistle is not producing any sound. Provide proper operation of the vessel’s whistle to the satisfaction of an attending Coast Guard marine inspector prior to getting underway.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2009
Resolved 14 May 2009
Resolution: Tug''s whistle has been repaired and performs satisfactory.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 2 April 2009
Resolved
Repair exhaust leak on expansion joint on vertical exhaust and exhaust leak on starboard side of engine to the satisfaction of an attending Coast Guard.
Action required: 705 - Other - as specified
Due 2 May 2009
Resolved 14 May 2009
Resolution: Vessel operator replaced entire section of vertical exhaust ductwork, no more leaks. Exhaust leak on starboard side of engine has been repaired.
Engineering › Fuel Oil Service System › Hose
Issued 2 April 2009
Resolved
Tug has a leak on a fuel supply hose at the fitting on the starboard side of the engine. Also a leak at the fuel hose fitting below the second valve from the diesel fuel tank just forward of the engine. Repair both leaks to the satisfaction of an attending marine inspector prior to getting underway.
Action required: 705 - Other - as specified
Due 2 May 2009
Resolved 14 May 2009
Resolution: Vessel operator replaced fuel supply hose on engine. Both leaks are repaired.
Engineering › Steering Gear System › Chain
Issued 5 April 2007
Resolved
Replace exterior steering cable on towing vessel.
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 2 April 2009
Resolution: Steering cable has been completely replaced.
Engineering › Steering Gear System › Bracket/Clamp
Issued 5 April 2007
Resolved
Double clamp steering cable in engine room.
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 2 April 2009
Resolution: Steering cable is double clamped.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 April 2007
Resolved
Repair exhaust leak on expansion joint on vertical exhaust.
Action required: 705 - Other - as specified
Due 7 May 2007
Resolved 5 April 2007
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 15 February 2006
Resolved
Properly label PFD storage lockers to reflect correct number of PFD's stowed inside
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 14 March 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 February 2006
Resolved
Install battery in engine room of towing vessel M/V Winfield in battery box IAW 46 CFR 183.354.
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 14 March 2006
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 15 February 2006
Resolved
Provide PFD donning placard IAW 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 14 March 2006
Engineering › Steering Gear System › Bracket/Clamp
Issued 31 March 2004
Resolved
Jockey bar installed with improper sized fastener, replace 3/4" bolt with proper sz. 15/16" or 1".
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2004
Resolution: Fastener renewed/replaced with proper size, satisfactorily.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 September 2002
Resolved
One Lifejacket deteriorated (holed) beyond repair.
Condition: Unknown
Due 16 September 2002
Resolved 16 September 2002
Resolution: Renewed jacket onsight.
Lifesaving
Issued 2 October 2000
Resolved
Prove proper operation of life buoy water light. To be corrected before vessel carries passengers or vehicles IAW the COI.
Condition: Unknown
Due 2 October 2000
Resolved 2 October 2000
Navigation
Issued 2 October 2000
Resolved
Prove proper operation of navigation lights before vessel carries passengers or vehicles IAW the COI.
Condition: Unknown
Due 2 October 2000
Resolved 2 October 2000
Lifesaving
Issued 2 October 2000
Resolved
Place 60' life line on life buoy before vessel carries passengers or vehicles IAW the COI.
Condition: Unknown
Due 2 October 2000
Resolved 2 October 2000
Documentation
Issued 2 October 2000
Resolved
Post vessel COI on the vessel. To be corrected before vessel carries passengers or vehicles IAW the COI.
Condition: Unknown
Due 2 October 2000
Resolved 2 October 2000
Lifesaving
Issued 2 October 2000
Resolved
Post Life Jacket instructions before vessel carries passengers or vehicles IAW the COI.
Condition: Unknown
Due 2 October 2000
Resolved 2 October 2000
Lifesaving
Issued 3 November 1999
Resolved
Repaint yellow safety line on center of loading deck.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Lifesaving
Issued 3 November 1999
Resolved
Restencil both warning signs and replace instructions for "Lifejacket Placards".
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Lifesaving
Issued 3 November 1999
Resolved
Remove all adult and child PFD's from storage area and clean and make readyfor inspection.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Navigation
Issued 3 November 1999
Resolved
Repair damaged flat black backgrounds for running lights, remount running lights and replace household 40 watt light bulbs with proper running light bulbs.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Lifesaving
Issued 3 November 1999
Resolved
Properly outfit vessel life buoy as per 46 CFR 180.70.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Lifesaving
Issued 3 November 1999
Resolved
Prove proper operation of towing vessel "M/V WINFIELD" particularly to towing vessel marine gear operation.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Construction/Loadline
Issued 3 November 1999
Resolved
Remove all water from void spaces, manufacture and install rubber gasket material for all void covers and replace all void cover hold down bolts.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Construction/Loadline
Issued 3 November 1999
Resolved
Prove proper operation of all bilge strainers and bilge pump by placing a bucket of water under each strainer and drawing suction with the bilge pumpin the presence of CG Inspector.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Construction/Loadline
Issued 27 August 1998
Resolved
Grind out and perform welding repair to 3" crack in deck plate on corner of#3 hold access plate as per 46 CFR 179.360.
Condition: Unknown
Due 27 August 1998
Resolved 31 August 1998
Lifesaving
Issued 27 August 1998
Resolved
Install corrosion resistant quick clip on waterlight lanyard as per _x001C_ 46 CFR 180.70d.
Condition: Unknown
Due 27 August 1998
Resolved 31 August 1998
Lifesaving
Issued 27 August 1998
Resolved
Install reflective tape at 90 degree intervals on life buoy as per _x001C_ 46 CFR 185.604(b).
Condition: Unknown
Due 27 August 1998
Resolved 31 August 1998
Documentation
Issued 6 October 1993
Resolved
POST STABILITY LETTER ON BOARD.
Condition: Unknown
Due 6 October 1993
Resolved 6 October 1993
Construction/Loadline
Issued 5 February 1993
Resolved
RENEW CRACKED WELDS ALONG FORWARD EDGE OF BOW LOADING RAMP.
Condition: Unknown
Due 7 March 1993
Resolved 26 February 1993
Deck/Cargo
Issued 5 February 1993
Resolved
DOUBLE NUT/SECURE THE BOLTS/PINS HOLDING RAMP CABLE PULLEYS IN PLACE AT EACH CORNER OF BARGE.
Condition: Unknown
Due 7 March 1993
Resolved 26 February 1993
Fire Fighting
Issued 5 February 1993
Resolved
SECURE FIRE PUMP SEA SUCTION PIPING TO FITTING.
Condition: Unknown
Due 7 March 1993
Resolved 26 February 1993
Construction/Loadline
Issued 5 February 1993
Resolved
IN HOLD #5, RENEW CRACKED WELDS ALONG AFT TWO OVERHEAD TRANSVERSE BEAMS AND MAIN DECK CONNECTIONS, AT AFT PORT MOORING BITT, AND AT 1/2 INCH HOLE IN VICINITY OF AFT PORT STANCHION.
Condition: Unknown
Due 7 March 1993
Resolved 26 February 1993
Construction/Loadline
Issued 5 February 1993
Resolved
ATTACH STRAINERS TO BILGE PIPING IN HOLD #1 AND #5.
Condition: Unknown
Due 7 March 1993
Resolved 26 February 1993
Unknown
Issued 15 December 1992
Resolved
Provide proof of compliance to the Federal Regulations for Drug testing.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Documentation
Issued 15 December 1992
Resolved
Provide a copy of stability calcualations from a Naval Architect.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Lifesaving
Issued 6 October 1992
Resolved
PROVIDE TOTAL OF 30 ADULT PFDS ONBD. VSL RESTRICTED TO NOT MORE THAN 29 ADULT PASSENGERS UNTIL CORRECTED.
Condition: Unknown
Due 6 October 1992
Resolved 6 October 1992
Lifesaving
Issued 6 October 1992
Resolved
ATTACH 60' FLOATING LINE TO RING BOUY AND ATTACH WATERLIGHT DURING LOW VISIBILITY OPERATIONS TO RING BOUY WITH SEPARATE LINE.
Condition: Unknown
Due 6 October 1992
Resolved 6 October 1992
Fire Fighting
Issued 6 October 1992
Resolved
PROVIDE METALLIC NOZZLE FOR FIRE HOSE.
Condition: Unknown
Due 6 October 1992
Resolved 6 October 1992
Documentation
Issued 6 October 1992
Resolved
PROVIDE GARBAGE PLACARD AND WASTE MANAGEMENT PLAN ONBD VSL.
Condition: Unknown
Due 6 October 1992
Resolved 6 October 1992
Deck/Cargo
Issued 6 October 1992
Resolved
PROVIDE ADEQUATE ANCHOR AND LINE ONBD VSL.
Condition: Unknown
Due 6 October 1992
Resolved 6 October 1992
Electrical
Issued 15 August 1989
Resolved
PROVIDE APPROVED WIRING FOR WINCH AND NAVIGATION LIGHTS.
Condition: Unknown
Due 15 August 1989
Resolved 15 August 1989
Construction/Loadline
Issued 15 August 1989
Resolved
WELD CRACK IN #1 VOID HATCH COVER.
Condition: Unknown
Due 15 August 1989
Resolved 15 August 1989
Construction/Loadline
Issued 15 August 1989
Resolved
PROVIDE SUITABLE GASKETS FOR HATCH COVERS TO VOIDS #1, 2, 4, AND 5.
Condition: Unknown
Due 15 August 1989
Resolved 15 August 1989
Fire Fighting
Issued 15 August 1989
Resolved
PROVIDE ONE ADDITIONAL B-I OR B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 15 August 1989
Resolved 15 August 1989
Fire Fighting
Issued 15 August 1989
Resolved
PROVIDE APPROVED BRACKETS FOR ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 15 August 1989
Resolved 15 August 1989