ALEX CHOUEST is a 1999 offshore supply vessel. The Coast Guard has recorded 36 inspections since 1999, most recently in August 2018, along with 37 deficiencies — 2 with no resolution recorded —.

Records from 1999 to 2018. Most recent: inspection, 28 August 2018.

Built
1999
Last inspected
28 August 2018
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9132337 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCZ2532
470382
Flag
UNITED STATES
338469000 (licence lapsed)
Maury page id
psix-470382

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 18 calendar years (1999–2018)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)249.6 ft × 60.0 ft × 27.5 ft
Registered tonnagegross 3,969 / net 1,190
ITC dimensions (L × B × D)249.6 ft × 60.0 ft × 27.5 ft
ITC tonnagegross 3,969 / net 1,190
BuilderNORTH AMERICAN SHIPBLDG · LAROSE, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4063 - Dead Weight, Ton
3684 - Displacement, Ton
3969 - Convention (Subpart B), Gross Ton
1190 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ2532MMSI 338469000 · expired · voluntarily equipped · granted 12 March 2009, cancelled 13 July 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 36

28 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6525308
5 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5876531
19 October 2015 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5747050
18 August 2014 MARPOL Annex I Examination · MARPOL Annex V Examination · Internal Structural Exam · Administrative Inspection · Drydock Exam · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4958415
10 January 2012 MARPOL Annex VI Survey · Administrative Inspection · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4222361
30 December 2011 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4216160
12 September 2011 Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4142858
22 December 2010 MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3914544
16 February 2010 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3684836
4 December 2009 MTSA/ISPS Verification · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3644246
27 January 2009 Ballast Water Examination · MTSA/ISPS Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3397586
20 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3211974
28 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3245303
28 January 2008 MARPOL Annex V Examination · Deficiency Check · MARPOL Annex I Examination · Ballast Water Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3137372
2 November 2007 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3091851
26 April 2007 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2919021
12 February 2007 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2871116
30 January 2007 Administrative Inspection · Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2867389
10 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2743271
1 March 2006 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2593966
26 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501632
24 February 2005 Re-Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2298382
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293966
29 October 2004 Examination of Repairs · Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2230753
26 February 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2013481
11 February 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2003131
3 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979547
12 February 2003 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1743488
26 February 2002 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1489204
19 November 2001 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1405290
8 February 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366160
11 March 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046661
24 February 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049130
23 November 1999 Initial Certification · Initial Construction-Excluding Oversight · Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468952
30 June 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 794384
1 February 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808257

Deficiency record · 37

10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 28 August 2018 No resolution recorded
Vessel has failed to report via LRIT per 33 CFR 169.230.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 August 2014 Resolved
Leaks found at crankcase breathers. Oil found on lagging around turbo chargers. Hoses on crankcase breathers need to be replaced. Lagging on both port/stbd engines alaso need replaced. Furthermore, lagging throughout the engine room needs replaced. Replace to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 9 December 2014
Resolved 10 December 2014
Resolution: Received photo of new lagging placed around engine room. Hoses on crankcase breathers were also rectified to the satisfaction of the CG Marine Inspector.
Fire Fighting › Fire Pumps › Pressure
Issued 22 December 2010 Resolved
Calibrate bridge fire pump .
Action required: 705 - Other - as specified
Due 22 January 2011
Resolved 23 January 2011
Resolution: Cleared by class
Construction/Loadline › Penetrations › Weld
Issued 22 December 2010 Resolved
Provide continuoues weld for ROV water intake piping pentetration. MI will witness NDT test of weld.
Action required: 705 - Other - as specified
Due 22 January 2011
Resolved 23 December 2010
Resolution: cleared by class
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 22 December 2010 Resolved
Repair stbd generator overspeed & exhaust gas temp alarms at control room alarm panel.
Action required: 705 - Other - as specified
Due 22 January 2011
Resolved 23 December 2010
Resolution: cleared by class
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 22 December 2010 Resolved
Remove waste oil from below stbd MDE.
Action required: 705 - Other - as specified
Due 22 December 2010
Resolved 22 December 2010
Electrical › Electric Generation Source (emergency) › Switch
Issued 22 December 2010 Resolved
Replace missing labels for emergency generator switchboard or confirm they are spare switches.
Action required: 705 - Other - as specified
Due 22 January 2011
Resolved 23 December 2010
Resolution: cleared by class
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 22 December 2010 Resolved
provide up-to-date fire safety plan for plan in fire plan tube at main door.
Action required: 705 - Other - as specified
Due 22 January 2011
Resolved 23 December 2010
Resolution: cleared by class
Documentation › Certificates/Documents › Engine IAPP Certificate
Issued 22 December 2010 Resolved
provide current EIAPP certificate for 2007 port main engine prior to foreign voyage or by Jan 8, 2012 IAW CG-543 Policy Ltr 09-01.
Action required: 705 - Other - as specified
Due 8 January 2012
Resolved 30 December 2011
Resolution: Cleared last remaining def from annual inspection on 22DEC10. Engine in question was not replaced or repowered. Just rebuilt. No EIAPP required.
Lifesaving › Rescue Boat › Drain Valve
Issued 28 January 2008 Resolved
Remove excess water and fuel in the bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Resolution: Excess water and fuel removed, vent line secured to ensure no more fuel would spill into bilge.
Communications › Radio Communications › EPIRB
Issued 28 January 2008 Resolved
Move EPIRB down from Cabin Top or provide additional EPIRB.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Resolution: EPIRB moved down to Cabin level.
Stability › Watertight Integrity › General
Issued 28 January 2008 Resolved
Repair all Wire Penetrations "Rox Blocks" as discussed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Resolution: Packing boxes corrected and missing blocks installed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 28 January 2008 Resolved
Repair all Stair Tower Hinged doors.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Resolution: All repairs completed, all doors fully close when relaesed.
Fire Fighting › Fire Pumps › Pressure
Issued 28 January 2008 Resolved
Repair indicator located on Bridge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Resolution: New sending unit installed.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 28 January 2008 Resolved
Adjust all Self Closing devices in the Engine Room, to ensure doors will close.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Resolution: Self closing devices adjusted and hold doors closed when not fully dogged.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 28 January 2008 Resolved
Demonstrate that Switchboard has Load Shedding ability, as the "E" Generatorcan be manually back fed.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Resolution: Load shedding apperatus is installed on the "E Switchboard", tested and adjusted.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 28 January 2008 Resolved
Make repairs to the Lower Aft Engine Room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Resolution: Engineer assistance alarm repaired.
Deck/Cargo › Cargo Stowage › General
Issued 28 January 2008 Resolved
Provide "Annual" maintenance report for "Dry Bulk" relief valves.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Resolution: New Dry Bulk relief valves installed after they completed testing.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 28 January 2008 Resolved
Update Fire and Safety Plan and submit for approval.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Resolution: Fire and Safety Plans delievered and are under review.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 2 November 2007 Resolved
Vessel shall install and demonstrate proper steering deviation alarm.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 27 January 2009
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 12 February 2007 Resolved
Demonstrate proper operation of fire dampers in bow thruster room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2007
Electrical › Electric Generation Source (service) › Generator
Issued 12 February 2007 Resolved
demonstrate proper operation of #3 generator
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2007
Engineering › Compressed Air System (start air) › Valve
Issued 12 February 2007 Resolved
relocate pressure relief valve, not on bottom of tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2007
Lifesaving › Rescue Boat › Propeller
Issued 12 February 2007 Resolved
Install propeller guard on Rescue Boat.
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 29 January 2008
Resolution: New Trim plate installed to facilitate installation of guard.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 1 March 2006 No resolution recorded
PROVIDE APPROVED DRAWING FOR MACHINERY INSTALLATION (GENERATOR& FUEL TANK) FOR ROV PRIOR TO 01APR2006
Action required: 705 - Other - as specified
Due 1 April 2006 — due date passed with no resolution recorded
Resolution: Vsl removed ROV generator and fuel tank, they are using existing power source.
Communications › Alarms/Indicators
Issued 12 February 2003 Resolved
Repair rudder angle indicator in Rudder Room steering station. LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 13 February 2003
Communications › Alarms/Indicators
Issued 12 February 2003 Resolved
Repair general alarm light in Engine Room. LEGACY COMPONENT DESC: General Alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 13 February 2003
Communications › Internal Communications System
Issued 12 February 2003 Resolved
Repair engine order telegraph to the satisfaction of an attending CG marine inspector. LEGACY COMPONENT DESC: Engine Order Telegraph System
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 13 February 2003
Engineering › Diesel Engine (auxiliary)
Issued 12 February 2003 Resolved
Renew chaffed high pressure fuel lines on center generator. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2003
Resolved 14 February 2003
Stability › Watertight Integrity
Issued 12 February 2003 Resolved
Adjust dogs on port stack watertight door. LEGACY COMPONENT DESC: Watertight Door
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2003
Resolved 13 February 2003
Electrical › Lighting (emergency)
Issued 12 February 2003 Resolved
Renew Engine Room control booth and 02 level emergency light batteries. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 13 February 2003
Stability › Watertight Integrity
Issued 12 February 2003 Resolved
Adjust dog on Emergency Generator Room watertight door. LEGACY COMPONENT DESC: Watertight Door
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2003
Resolved 13 February 2003
Fire Fighting › Remote Fuel Shutoff
Issued 12 February 2003 Resolved
Repair day tank emergency shut-off valves to the satisfaction of an attending CG marine inspector. LEGACY COMPONENT DESC: Emergency Shut-off Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 13 February 2003
Electrical › Electric Supply System (service)
Issued 12 February 2003 Resolved
Demonstrate proper operation of reverse power relays on all generators to the satisfaction of an attending CG marine inspector. LEGACY COMPONENT DESC: Reverse Current Protection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 13 February 2003
Engineering
Issued 23 November 1999 Resolved
Aft console, Ulstein Propeller RPM guage, scales are differant on port and starboard controls. Stbd max rpm=350, port max rpm=250. Make both same and verify settings.
Condition: Unknown
Due 27 December 1999
Resolved 19 December 1999
Engineering
Issued 23 November 1999 Resolved
Aft pilot house console, starboard propeller emergency pitch control inoperative, repair/prove operation.
Condition: Unknown
Due 17 December 1999
Resolved 19 December 1999
Unknown
Issued 23 November 1999 Resolved
Prove proper operation of eng alarm panel test button on pilot house and engine control room alarm panels._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1999
Resolved 19 December 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.