Inspection history · 21
6 June 2024
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7929585
16 May 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7913610
11 May 2024
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7910466
27 March 2024
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7884546
18 March 2024
PSC A · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7880788
24 January 2024
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7853605
22 January 2024
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7852037
19 January 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7851148
25 September 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7797807
22 August 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7774146
27 June 2023
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7724956
7 June 2023
Deficiency Check · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7706191
1 May 2023
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7678841
28 April 2023
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7677426
26 April 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7676096
26 April 2023
PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7676349
4 November 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6299872
11 March 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5829854
12 February 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5814473
11 February 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5813671
10 February 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5812577
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 7 June 2024
Resolved
To assist in casualty investigations, cargo ships, when engaged on international voyages, shall be fitted with a VDR which may be a simplified voyage data recorder (S-VDR). PSCO's were notified and identified that the VDR is not fully functional.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2024
Resolved 7 June 2024
Resolution: Received technician report from Wartsila attesting to satisfactory repairs of the VDR.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 27 March 2024
Resolved
All items of rescue boat equipment...shall be secured within the rescue boat. PSCO observed rescue boat items in a storage locker.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2024
Resolved 11 May 2024
Resolution: Please see attached class survey and report from Flag.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 27 March 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons onboard. PSCO observed operation of the class approved temporary repair to the rescue boat davit.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 May 2024
Resolved 11 May 2024
Resolution: Please see attached class survey and report from Flag
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 18 March 2024
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCOS OBSERVED NON-APPROVED RESCUE BOAT DAVIT OPERATION. RESCUE BOAT DAVIT IS MISSING ITS ELECTRIC MOTOR AND IS BEING OPERATED BY A PULLEY SYSTEM ATTACHED TO A MOORING WINCH.
74 SOLAS (97)III/19.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2024
Resolution: Vessel repaired INOP rescue boat davit IAW approved proposal. Class report attested to load test and satisfactory repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 January 2024
Resolved
All electrical apparatus shall be so constructed and installed so as not to cause injury when handled or touched in a normal manner.
PSCO observed exposed wiring on the junction box for the purifier space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 January 2024
Resolved
Where penetrations of watertight bulkheads are necessary for access arrangements are to be made to maintain the watertight integrity.
PSCO observed the port and starboard quick acting watertight doors from the engine room to have loose dogs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 24 January 2024
Resolved
Rapid recovery of the rescue boat shall be possible when loaded with its full compliment of persons and equipment.
Vessels rescue boat winch is outfitted with an electric motor for launching and recovery that is not operational.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 March 2024
Resolution: Re-issued deficiency as at Code 17 (prior to departure) due to failure to meet repair timeline. Activity #7880877
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 January 2024
Resolved
the following basic principles underlie the regulations in this chapter and are embodied in the regulations as appropriate, having regard to the type of ships and the potential fire hazard involved: .3 Restricted use of combustiable materials.
PSCO observed on multiple occasions oil and fuel oil stored in non-approved containers and approval containers scattered throughout the engine room space. Additionally, PSCO observed paint storage hidden in port side void of engine room.
74 SOLAS (97) II-2/2.2.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2024
Resolved 20 January 2024
Resolution: Received class report attesting to repairs. Containers moved to proper stowage locations.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 19 January 2024
Resolved
Every ship of 100 gross tonnage and above, and every ship which is certified to carry 15 or more persons, and fixed or flooding platforms shall carry a garbage management plan which the crew shall follow.
PSCO observed immense ammount of trash in multiple areas of the engine room. Trash was incorrectly stored in some cases.
MARPOL V/10.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2024
Resolved 20 January 2024
Resolution: Received class report attesting to repairs. Garbage sorted and arranged for removal.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 January 2024
Resolved
All electrical apparatus shall be so constructed and installed so as to cause injury when handled or touched in a normal manner.
PSCO observed exposed wiring on the stop button for the purifier space.
74 SOLAS (97) II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2024
Resolved 20 January 2024
Resolution: Received class report attestings to repairs. Stop button replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 January 2024
Resolved
The machinery boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and constructed adequate for the service for which they are installed...
PSCO observed excessive damage and wastage to clorifier and boiler hot well resulting in extreme water leakage and possible watchstander burns.
74 SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 January 2024
Resolved 20 January 2024
Resolution: Received class report attestings to repairs. Leak repaired.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 19 January 2024
Resolved
The company and the ship shall comply with the requirements of the international safety management code. For the pupose of this regulation, the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions or the relevant rules and regulations and with any additional requirements which may be established by the company. In accordance with the vessel's safety management system: the environmental program includes a commitment to continnual improvement and prevention of pollution, complywith relevant environmental legislation and regulation. the previouslynoted deficiency 2 demonstrates that they crew is not following their safety management system. An external audit is required.
74 SOLAS (20) IX/3.1
ISM Code Part A/ 10.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2024
Resolved 20 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 22 August 2023
Resolved
Each lifeboat shall be provided with an appliance which is capable of launching and recovering the lifeboat. Lifeboat stuck in position and unable to be recovered. Refer to 74SOLAS(97)CH III/15.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2023
Resolution: Replaced winch for the free fall life boat
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 7 June 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed a soft patch on a drain pipe leading into the steering gear room. Additionally, PSCO found 02 steam return pipes leaking with fabricated plastic catch basins in main machinery space.
74SOLAS(20)I-II/a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 26 June 2023
Resolution: Sec New York received documentations from vessel's class indicating the deficiency has been rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 June 2023
Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position. PSCO observed several cylinders stored improperly throughout the vessel's engine room.
46CFR147.60(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2023
Resolved 26 June 2023
Resolution: Sec New York received pictures from vessel providing proof of deficiency correction.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 April 2023
Resolved
The means for securing and maintaining weather tightness shall be to the satisfaction of the administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions. Hate cover securing devices in vicinity of bays 26, 30, 34, and 38 starboard side are warped and do not serve the intended purpose. Other locking devices for those hatch covers meet the requirements.
ICLL(88) 16/4
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 May 2023
Resolved 7 June 2023
Resolution: Flag has authorized class to issue a short term ILLC for 3 months giving the vessel additional time to rectify this issue.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 April 2023
Resolved
The means for securing these doors weathertight shall consist of gaskets and clamping devices or other equivalent means. Door in vicinity of rescue boat does not close in a manner that provides for weather-tightness.
ICLL(88) 12/1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2023
Resolved 27 April 2023
Resolution: Crew corrected door to the satisfaction of the Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 April 2023
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. Doors to the ship’s office and hospital space are identified as self-closing on FCP. Both have holdbacks not fitted w/ remote release.
74 SOLAS(97 cons) II-2/47.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 28 April 2023
Resolved 27 April 2023
Resolution: Crew corrected doors to the satisfaction of the Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 April 2023
Resolved
The fire resistance of doors shall as far as practicable, be equivalent to that of the division to which they are fitted. Doors to steering gear space and engine storeroom have key-locking mechanisms removed leaving opening in the doors. Door on main deck to cable trunk does not close completely.
74 SOLAS(97 cons) II-2/47.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2023
Resolved 27 April 2023
Resolution: Crew corrected doors to the satisfaction of the Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 26 April 2023
Resolved
…the minimum fire integrity of bulkheads and decks shall be as prescribed in table 44.1…flammable liquids found stored inside boundary of machinery space.
74 SOLAS(97 cons) II-2/44.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2023
Resolved 27 April 2023
Resolution: Crew removed fuel samples to forward paint locker with appropriate fire integrity to the satisfaction of the Coast Guard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 26 April 2023
Resolved
Efficient guard rails…shall be fitted to all exposed parts of the freeboard and superstructure decks. Guard rail in vicinity of bays 19 and 21 found broken.
ICLL (88) 25/2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 May 2023
Resolved 7 June 2023
Resolution: Vessel has repaired these guardrails by replacing rusted/damaged ones.
Communications › Radio Communications › EPIRB
Issued 12 February 2016
Resolved
Satellite EPIRB shall be annually tested for all aspects of operational efficency, on cargo ships, 3 months before or aftger the anniversary date of the cargo ship safety radio certificate. PSCO found that the annual test of EPIRB was expired 04 months beyond the anniversay date. 74SOLAS (14 cons ed) IV/15.9.1.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2016
Resolved 12 February 2016
Resolution: A technician came aboard and tested the EPIRB successfully.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 12 February 2016
Resolved
A rescue boat shall be fitted with an inboard or outboard engine on the rescue boat. The outboard engine was not operational and the ship had a dispensation from Liberia until 29FEB2016 PSCO could not test the outboard engine on the rescue boat durin the course of examination. 74 SOLAS (97 cons ed) III/47.1.7
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 11 March 2016
Resolution: PSCO inspected and witnessed proper operation of the ship's rescue boat.