MAURY USCG vessel records Sign in
← All vessels

BUXFAVOURITE

BUXFAVOURITE is a 1997 freight ship. The Coast Guard has recorded 39 inspections since 1998, most recently in June 2024, along with 33 deficiencies and 10 operational controls.

Records from 1998 to 2024. Most recent: operational control imposed, 7 June 2024.

Built
1997
Last inspected
6 June 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9150212 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
470444
Flag
LIBERIA
—
Maury page id
psix-470444

Inspections, by type

…with no type recorded20
Years with a record 13 calendar years (1998–2024)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it44719 - Displacement, Ton
34014 - Dead Weight, Ton
25713 - Convention (Subpart B), Gross Ton
12275 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 39

6 June 2024 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7929585
16 May 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7913610
11 May 2024 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7910466
27 March 2024 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7884546
18 March 2024 PSC A · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7880788
24 January 2024 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7853605
22 January 2024 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7852037
19 January 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7851148
25 September 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7797807
22 August 2023 In-Service Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7774146
27 June 2023 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7724956
7 June 2023 Deficiency Check · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7706191
1 May 2023 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7678841
28 April 2023 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7677426
26 April 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7676096
26 April 2023 PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7676349
4 November 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6299872
11 March 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5829854
12 February 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5814473
11 February 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5813671
10 February 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5812577
8 May 2012 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4305356
19 October 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3872922
12 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3662773
19 December 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3652888
30 March 2009 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3443051
29 March 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3439590
15 August 2004 ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2166584
23 December 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1968943
11 April 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1772104
8 January 2003 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1727643
4 October 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 294430
24 February 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 275095
9 February 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 425309
23 April 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 415068
11 March 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 413511
6 March 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 413512
4 March 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 413373
10 February 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 412638

Deficiency record · 33

10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 7 June 2024 Resolved
To assist in casualty investigations, cargo ships, when engaged on international voyages, shall be fitted with a VDR which may be a simplified voyage data recorder (S-VDR). PSCO's were notified and identified that the VDR is not fully functional.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2024
Resolved 7 June 2024
Resolution: Received technician report from Wartsila attesting to satisfactory repairs of the VDR.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 27 March 2024 Resolved
All items of rescue boat equipment...shall be secured within the rescue boat. PSCO observed rescue boat items in a storage locker.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2024
Resolved 11 May 2024
Resolution: Please see attached class survey and report from Flag.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 27 March 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons onboard. PSCO observed operation of the class approved temporary repair to the rescue boat davit.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 May 2024
Resolved 11 May 2024
Resolution: Please see attached class survey and report from Flag
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 18 March 2024 Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCOS OBSERVED NON-APPROVED RESCUE BOAT DAVIT OPERATION. RESCUE BOAT DAVIT IS MISSING ITS ELECTRIC MOTOR AND IS BEING OPERATED BY A PULLEY SYSTEM ATTACHED TO A MOORING WINCH. 74 SOLAS (97)III/19.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2024
Resolution: Vessel repaired INOP rescue boat davit IAW approved proposal. Class report attested to load test and satisfactory repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 January 2024 Resolved
All electrical apparatus shall be so constructed and installed so as not to cause injury when handled or touched in a normal manner. PSCO observed exposed wiring on the junction box for the purifier space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 January 2024 Resolved
Where penetrations of watertight bulkheads are necessary for access arrangements are to be made to maintain the watertight integrity. PSCO observed the port and starboard quick acting watertight doors from the engine room to have loose dogs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 24 January 2024 Resolved
Rapid recovery of the rescue boat shall be possible when loaded with its full compliment of persons and equipment. Vessels rescue boat winch is outfitted with an electric motor for launching and recovery that is not operational.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 March 2024
Resolution: Re-issued deficiency as at Code 17 (prior to departure) due to failure to meet repair timeline. Activity #7880877
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 January 2024 Resolved
the following basic principles underlie the regulations in this chapter and are embodied in the regulations as appropriate, having regard to the type of ships and the potential fire hazard involved: .3 Restricted use of combustiable materials. PSCO observed on multiple occasions oil and fuel oil stored in non-approved containers and approval containers scattered throughout the engine room space. Additionally, PSCO observed paint storage hidden in port side void of engine room. 74 SOLAS (97) II-2/2.2.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2024
Resolved 20 January 2024
Resolution: Received class report attesting to repairs. Containers moved to proper stowage locations.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 19 January 2024 Resolved
Every ship of 100 gross tonnage and above, and every ship which is certified to carry 15 or more persons, and fixed or flooding platforms shall carry a garbage management plan which the crew shall follow. PSCO observed immense ammount of trash in multiple areas of the engine room. Trash was incorrectly stored in some cases. MARPOL V/10.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2024
Resolved 20 January 2024
Resolution: Received class report attesting to repairs. Garbage sorted and arranged for removal.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 January 2024 Resolved
All electrical apparatus shall be so constructed and installed so as to cause injury when handled or touched in a normal manner. PSCO observed exposed wiring on the stop button for the purifier space. 74 SOLAS (97) II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2024
Resolved 20 January 2024
Resolution: Received class report attestings to repairs. Stop button replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 January 2024 Resolved
The machinery boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and constructed adequate for the service for which they are installed... PSCO observed excessive damage and wastage to clorifier and boiler hot well resulting in extreme water leakage and possible watchstander burns. 74 SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 January 2024
Resolved 20 January 2024
Resolution: Received class report attestings to repairs. Leak repaired.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 19 January 2024 Resolved
The company and the ship shall comply with the requirements of the international safety management code. For the pupose of this regulation, the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions or the relevant rules and regulations and with any additional requirements which may be established by the company. In accordance with the vessel's safety management system: the environmental program includes a commitment to continnual improvement and prevention of pollution, complywith relevant environmental legislation and regulation. the previouslynoted deficiency 2 demonstrates that they crew is not following their safety management system. An external audit is required. 74 SOLAS (20) IX/3.1 ISM Code Part A/ 10.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2024
Resolved 20 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 22 August 2023 Resolved
Each lifeboat shall be provided with an appliance which is capable of launching and recovering the lifeboat. Lifeboat stuck in position and unable to be recovered. Refer to 74SOLAS(97)CH III/15.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2023
Resolution: Replaced winch for the free fall life boat
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 7 June 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed a soft patch on a drain pipe leading into the steering gear room. Additionally, PSCO found 02 steam return pipes leaking with fabricated plastic catch basins in main machinery space. 74SOLAS(20)I-II/a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 26 June 2023
Resolution: Sec New York received documentations from vessel's class indicating the deficiency has been rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 June 2023 Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position. PSCO observed several cylinders stored improperly throughout the vessel's engine room. 46CFR147.60(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2023
Resolved 26 June 2023
Resolution: Sec New York received pictures from vessel providing proof of deficiency correction.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 April 2023 Resolved
The means for securing and maintaining weather tightness shall be to the satisfaction of the administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions. Hate cover securing devices in vicinity of bays 26, 30, 34, and 38 starboard side are warped and do not serve the intended purpose. Other locking devices for those hatch covers meet the requirements. ICLL(88) 16/4
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 May 2023
Resolved 7 June 2023
Resolution: Flag has authorized class to issue a short term ILLC for 3 months giving the vessel additional time to rectify this issue.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 April 2023 Resolved
The means for securing these doors weathertight shall consist of gaskets and clamping devices or other equivalent means. Door in vicinity of rescue boat does not close in a manner that provides for weather-tightness. ICLL(88) 12/1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2023
Resolved 27 April 2023
Resolution: Crew corrected door to the satisfaction of the Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 April 2023 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. Doors to the ship’s office and hospital space are identified as self-closing on FCP. Both have holdbacks not fitted w/ remote release. 74 SOLAS(97 cons) II-2/47.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 28 April 2023
Resolved 27 April 2023
Resolution: Crew corrected doors to the satisfaction of the Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 April 2023 Resolved
The fire resistance of doors shall as far as practicable, be equivalent to that of the division to which they are fitted. Doors to steering gear space and engine storeroom have key-locking mechanisms removed leaving opening in the doors. Door on main deck to cable trunk does not close completely. 74 SOLAS(97 cons) II-2/47.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2023
Resolved 27 April 2023
Resolution: Crew corrected doors to the satisfaction of the Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 26 April 2023 Resolved
…the minimum fire integrity of bulkheads and decks shall be as prescribed in table 44.1…flammable liquids found stored inside boundary of machinery space. 74 SOLAS(97 cons) II-2/44.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2023
Resolved 27 April 2023
Resolution: Crew removed fuel samples to forward paint locker with appropriate fire integrity to the satisfaction of the Coast Guard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 26 April 2023 Resolved
Efficient guard rails…shall be fitted to all exposed parts of the freeboard and superstructure decks. Guard rail in vicinity of bays 19 and 21 found broken. ICLL (88) 25/2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 May 2023
Resolved 7 June 2023
Resolution: Vessel has repaired these guardrails by replacing rusted/damaged ones.
Communications › Radio Communications › EPIRB
Issued 12 February 2016 Resolved
Satellite EPIRB shall be annually tested for all aspects of operational efficency, on cargo ships, 3 months before or aftger the anniversary date of the cargo ship safety radio certificate. PSCO found that the annual test of EPIRB was expired 04 months beyond the anniversay date. 74SOLAS (14 cons ed) IV/15.9.1.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2016
Resolved 12 February 2016
Resolution: A technician came aboard and tested the EPIRB successfully.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 12 February 2016 Resolved
A rescue boat shall be fitted with an inboard or outboard engine on the rescue boat. The outboard engine was not operational and the ship had a dispensation from Liberia until 29FEB2016 PSCO could not test the outboard engine on the rescue boat durin the course of examination. 74 SOLAS (97 cons ed) III/47.1.7
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 11 March 2016
Resolution: PSCO inspected and witnessed proper operation of the ship's rescue boat.
Navigation
Issued 6 March 1998 Resolved
vessel's agent, inchcape shipping, failed to notify COTP Philadelphia of vsl's arrival as outlined in 33CFR 160.207.
Condition: Unknown
Due 6 March 1998
Resolved 9 March 1998
Navigation
Issued 6 March 1998 Resolved
U.S. Lightlist vol. II used by vesssel not currently corrected to latest NTM available at time of transit._x001C_
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Fire Fighting
Issued 10 February 1998 Resolved
Provide gasket and washers for international shore connection.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Documentation
Issued 10 February 1998 Resolved
Provide original COFR onboard vessel prior to next U.S. port.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Lifesaving
Issued 10 February 1998 Resolved
Update all muster lists to include all duties described in SOLAS 74 ChapterIII/53. In addition, designate a GMDSS operator radio communication responsibilities in accordance with SOLAS 74 Chapter IV/16.1.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Lifesaving
Issued 10 February 1998 Resolved
Repair defective waterlight on ring buoy located at the starboard accommodation ladder.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Lifesaving
Issued 10 February 1998 Resolved
Properly mark rescue boat in accordance with SOLAS III/47.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Documentation
Issued 10 February 1998 Resolved
Provide German Administration endorsements for the third mate and third engineer who currently hold Filipino licenses IAW STCW 1/10.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 10 February 1998 Resolved
Provide SOLAS training manuals for each crew messroom and recreation room in a language of the crew.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Accommodation/Occupational Safety
Issued 10 February 1998 Resolved
Provide documentation that the Type II MSD is Coast Guard certified in accordance with 33CFR159.12.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.