← All vessels
TWIN STAR
Freight Ship · Bulk Carrier class · Built 1990s · USCG Northwest District (CGD-NW) · Other hulls named TWIN STAR
TWIN STAR is a 1998 freight ship. The Coast Guard has recorded 13 inspections since 1998, most recently in May 2005, along with 6 deficiencies and 1 operational control.
Records from 1998 to 2005. Most recent: inspection, 12 May 2005.
- Built
- 1998
- Last inspected
- 12 May 2005
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9171711 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FBV8
470501
Flag
PANAMA
—
Maury page id
psix-470501
Inspections, by type
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it8741 - Convention (Subpart B), Net Ton
23701 - Dead Weight, Ton
28732 - Displacement, Ton
14437 - Convention (Subpart B), Gross Ton
23701 - Dead Weight, Ton
28732 - Displacement, Ton
14437 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
12 May 2005
ISPS II Exam · PII Safety Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2356251
28 May 2004
Deficiency Check · Administrative Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2081157
17 January 2004
Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1987329
17 September 2003
MARPOL Annex I Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1907111
4 January 2003
Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1721335
31 July 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 292254
12 January 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 285821
3 July 2000
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 279784
23 March 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 275906
2 February 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 274193
30 June 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 430100
18 August 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 419226
11 February 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 413545
Deficiency record · 6
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 12 May 2005
Resolved
Vessel has three EEBDs not fully charged. Arrow indicated near empty on one, and the two others were no longer in the "green".
Pollution Prevention/Response › Prevention Equipment
Issued 17 January 2004
Resolved
Incinerator- Make permanent repairs to refractory on door of incinderator (where large chunk has broken off) to the satisfaction of USCG PSC). SOLAS 74 Amd. I/11 LEGACY COMPONENT DESC: Waste Oil Incinerator
Electrical
Issued 3 July 2000
Resolved
Install non-conductive deck covering in front of electrical switchboard located on port side in forecastle. SOLAS II-1/40.1.3
Fire Fighting
Issued 2 February 2000
Resolved
Have (3) semi-portable foam fire extinguishers in engine room serviced by an approved servicing facility. Extinguishers show evidence of leaking. SOLAS 74 amd II-2/6. Correct prior to next U.S. port after sailing foreign.
Navigation
Issued 30 June 1999
Resolved
PROVIDE CURRENT/CORRECTED COAST PILOT NO.7 PRIOR TO DEPARTURE FROM THIS PORT. 33 CFR 164
Fire Fighting
Issued 30 June 1999
Resolved
AMEND ALL FIRE CONTROL PLANS TO INCLUDE E/R DAMPERS AT FUNNEL ON "C" DECK. SOLAS 74 AMD II-2/20. CORRECT PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.