ST YAKOV

ST YAKOV is a 1998 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 2016, most recently in March 2026, along with 69 deficiencies, 2 operational controls and 2 casualty investigations between 2002 and 2014.

Records from 2002 to 2026. Most recent: inspection, 31 March 2026.

Built
1998
Last inspected
31 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 March 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ9827
470597
Flag
UNITED STATES
Maury page id
psix-470597

Documentation record

Registered dimensions (L × B × D)78.5 ft × 28.5 ft × 8.3 ft
Registered tonnagegross 91 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALLEN MARINE INC · SITKA, AK, UNITED STATES · built 1998
Hull materialAluminum
PropulsionJet Drive
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portSITKA, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Simplified, Gross Ton
73 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 36

31 March 2026 Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8338751
1 December 2025 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8276056
1 August 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8198566
17 April 2025 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8113465
2 May 2024 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7905726
25 September 2023 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7798273
7 April 2023 Deficiency Check · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7663380
21 February 2023 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7639892
1 September 2022 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7549289
2 May 2022 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7442806
19 July 2021 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7261211
28 May 2020 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6962898
18 February 2020 Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6911219
22 October 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6842159
9 October 2019 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6831772
11 September 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6810685
17 May 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6688879
3 May 2019 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6676331
9 April 2019 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6659167
25 March 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6649060
27 November 2018 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6588373
6 November 2018 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6576044
27 April 2018 Deficiency Check · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6404883
19 April 2018 Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6402902
16 April 2018 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6392923
5 April 2018 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6386167
23 March 2018 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6375237
12 December 2017 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6325023
5 June 2017 Damage Survey · Examination of Repairs
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6166859
11 May 2017 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6143901
5 May 2017 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6148863
12 April 2017 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6123302
14 November 2016 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6041121
12 May 2016 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5875457
27 April 2016 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5864902
21 April 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5859838

Deficiency record · 69

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 March 2026 Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Exhaust cooling line on stbd fwd, and both port side engines, are zip tied to framing and/or engine. Replace support with adequate securing mechanism.46CFR182.430(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2026
Resolution: Hoses were secured with metal/chaffing bracket.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 31 March 2026 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot). Stbd forward railing stanchion has a crack at base.46CFR177.900(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2026
Resolution: Crack was eliminated via weld.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 March 2026 Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI identified multiple loose/disconnected electrical cables under bridge operating station. Additionally standing water was observed in the same location. Remove any obsolete electrical cables. Remove water, identify source of water ingress, and make proper repairs.46CFR183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2026
Resolution: Operating station on stbd bridge wing was re-sealed. No water intrusion observed. Loose electrical cables were properly insulated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 March 2026 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Stbd fuel tank strainer is cracked. Repair and test bilge pick up with Marine Inspector present. 46CFR182.510(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2026
Resolution: Strainer was replaced and bilge suction was tested with MI present.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 2 May 2024 Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Compass light is inoperable. Vessel restricted to daylight operations. 46CFR184.402(c).
Action required: 705 - Other - as specified
Resolved 8 May 2024
Resolution: Attended vessel and verified light fature; all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 September 2023 Resolved
04 holes were located in the port engine room aft bulkhead where previous equipment was mounted. Make the bulkhead water/vapor tight.
Action required: 705 - Other - as specified
Resolved 7 April 2024
Resolution: Holes repaired sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 April 2023 Resolved
Whenever damage or deterioration to the hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks and may require the vessel to be drydocked or taken out of service to assess the extent of the of the damage, and to effect permanent repairs. Marine Inspector found pitting in the #2 void stbd side in the first sections on both sides of the CVK and in the #3 void stbd side in the first section on both sides of the CVK. Operator made temp repairs to voids. Operator is to make permanent repairs by cropping and renewing all areas were temp repairs were installed at the next Drydock in Mar 2024.
Action required: 705 - Other - as specified
Resolved 25 September 2023
Resolution: Cleared and re-added to DDX/ISE activity #7798273.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 April 2023 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. Replace missing / damaged lagging on the port aft engine where the exhaust exits the turbo charger there is a section of exposed dry exhaust.46 CFR 177.970
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2023
Resolved 28 April 2023
Resolution: Lagging installed as required.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 April 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. (b) Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Vessel did not have back up paper charts or secondary electronic charts. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2023
Resolved 7 April 2023
Resolution: Operator placed onboard 2023 up to date paper charts for all op areas - all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 April 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit is missing the ophthalmic ointment or eyewash. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2023
Resolved 28 April 2023
Resolution: Eye wash was added to first aid kit.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 April 2023 Resolved
Whenever damage or deterioration to the hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks and may require the vessel to be drydocked or taken out of service to assess the extent of the of the damage, and to effect permanent repairs. Marine Inspector found pitting in the #2 void stbd side in the first sections on both sides of the CVK and in the #3 void stbd side in the first section on both sides of the CVK. Operator is to provide plan to temporarily address pitting from corrosion and plans to permanently address the pitting from corrosion.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2023
Resolution: Temporary repairs were completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 7 April 2023 Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. The lifelines previously installed on the starboard aft of the vessel was missing the lower courses. Operator is to reinstall lifelines to original condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2023
Resolved 28 April 2023
Resolution: Lifelines were installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 May 2022 Resolved
The engine shutdown for the starboard fwd engine did not shutdown when the CO2 engine shutdown was initiated. Repair/renew to original condition prior to departure.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 May 2022
Resolution: Engine shutdown was tested and operated correctly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 May 2022 Resolved
The heat detector in the generator room appears to have been tested using an open flame. The detector was blackened and cracked. Repair/renew the detector to original condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2022
Resolution: New heat detector installed and tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 May 2022 Resolved
All four main engines had exposed exhaust piping that exceeded 200 degrees F. Insulate all piping that exceeds 140 degrees F on engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2022
Resolution: Owners mechanic replaced the missing exhaust lagging - all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2022 Resolved
Dead ended wires from old camera system were hanging in starboard engine room. Remove and properly terminate all dead ended wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2022
Resolution: Owners mechanic removed the dead end wires - all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2022 Resolved
The light fixture installed in the generator space was installed with a exposed "extension cord" style plug. Re-install cable properly as per regulations.
Action required: 10 - Deficiency Rectified
Resolved 3 May 2022
Resolution: Light fixture wired correctly.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 May 2022 Resolved
A New light fixture was installed in the generator space. Provide proof that the fixtures meet UL-595 as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 September 2022
Resolution: Operator installed an approved light fixture in the engine room - all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 February 2020 Resolved
At next dry dock provide inspection for repairs to Hull areea approximately 12' x 10' of tunnel cropped and renewed as well as inboard sideshell from tunnel down approximately 18" and 5' from transom forward
Action required: 705 - Other - as specified
Due 12 January 2021
Resolved 1 February 2022
Resolution: Areas inspected SAT.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 October 2019 Resolved
Replaced both port and starboard time delay bottles. Both trips at around 24 and 27 seconds on a 30 second bottle
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2022
Resolution: Received tech report. Annual servicing and time delay test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2019 Resolved
Port aft and starboard aft main engines have exhaust leaks. Vessel master and crew were unaware of length of time leaks existed. Repair exhaust systems to roiginal condition.
Action required: 30 - Ship detained
Resolved 9 October 2019
Resolution: Exhaust leaks repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 September 2019 Resolved
Racor filter for generator was leaking fuel near base of filter and had a plastic plug. Replace plug with one of proper material for filter and repair leak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 September 2019 Resolved
Generator has an oil leak at the rear seal causing oil to contaminate generator windings creating a fire risk.Oil leak must be repaired and generator windings must be cleaned prior to vessel operating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2019
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 September 2019 Resolved
Vessel logs do not show vessel crew has conducted drills on vessel or similar vessel within three months. Ensure vessel crew conducts drills and logs as appropriate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 April 2019 Resolved
Prove property operation of starboard forward main engine jet bearing
Action required: 705 - Other - as specified
Resolved 3 May 2019
Resolution: Witnessed a satisfactory operational test of the starboard outboard jet drive.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 March 2019 Resolved
Vessel is required to have an operational self priming power driven fire pump; vessel's fire pump was seized and failed to operate.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 29 March 2019
Resolution: Witnessed an opertional test of the vessel's fire pump.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 25 March 2019 Resolved
Vessel's required high water level alarms failed to operate.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 29 March 2019
Resolution: The panel fault was caused by a shorted pyrometer which was renewed. Witnessed an operational test.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 March 2019 Resolved
Vessel is required fire detection system failed to operate.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 29 March 2019
Resolution: The panel fault was caused by a shorted pyrometer which was renewed. Witnessed an operational test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 March 2019 Resolved
Vessel's bilge dewatering system was unavailable for testing.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 29 March 2019
Resolution: Witnessed an operational test of the vessel's bilge pumps and crossover.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 March 2019 Resolved
An EPIRB's battery shall be replaced prior to its expiration date; renew the EPIRB's expired battery. Vessel is restricted to voyages within 3nm of land.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 29 March 2019
Resolution: Verified the EPIRB's battery was renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2019 Resolved
Vessel must have a means of shutting down a propulsion engine from the pilothouse; the port aft engine failed to secure.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 29 March 2019
Resolution: Verified the port aft engine would secure from the pilot house.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 25 March 2019 Resolved
Each entrance to a space protected by co2 must be properly marked; the stbd engine room entrance warning label was unreadable.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 29 March 2019
Resolution: Veririfed both engine room entrances received new CO2 placards.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 March 2019 Resolved
The port fwd engine flywheel was uncovered and did not have adequate protection for personnel.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 29 March 2019
Resolution: Verified a flywheel cover was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2019 Resolved
All electrical circuits must be clearly marked/identified; the main breaker located at the generator was unlabeled.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 29 March 2019
Resolution: Verified the identified breaker was labeled.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 November 2018 Resolved
Prove port aft engine secures when CO2 is discharged,
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 March 2019
Resolution: Witnessed an operational test of the CO2 shutdown for the port aft engine.
Construction/Loadline › Hull › Weld
Issued 16 April 2018 Resolved
Repair five cracked hull welds to the satisfaction of the attending MI prior to carrying passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2018
Resolution: See narrative.
Construction/Loadline › Hull › Weld
Issued 16 April 2018 Resolved
Repair ~12 cracked welds connecting hull plating to stiffeners to the satisfaction of the attending CG MI prior to carrying passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2018
Resolution: See narrative.
Navigation › Collision/Grounding Avoidance › Transponder
Issued 23 March 2018 Resolved
Broadcasting incorrect AIS information.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 April 2018
Resolution: vessel has upadte AIS info
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 23 March 2018 Resolved
Provide a flame screen for the port fuel tank vent.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 5 April 2018
Resolution: Verified fuel tank vent was properly fitted with the appropriate flame screen.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 March 2018 Resolved
Provide an current Certificate of Documentation.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 April 2018
Resolution: Vessel has new COD
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 March 2018 Resolved
Post an SPV Decal in an area visible to passengers.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 5 April 2018
Resolution: Verified installation of current SPV Decals at points of passenger embarkation.
Construction/Loadline › Hull › Bottom Plating
Issued 23 March 2018 Resolved
Provide proposal to repair hull plate pin holes identified in the port jet room.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 5 April 2018
Resolution: Wasted area was cropped and renewed via insert. Conducted visual exam and vacuum test, all sat.
Construction/Loadline › Penetrations › Pipe Flange
Issued 23 March 2018 Resolved
Provide a valve for the p/w penetration in the fwd bulkhead of the port e/r.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 5 April 2018
Resolution: Verfied installation of metalic valve on the bulkhead penetration.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 23 March 2018 Resolved
Port aft main diesel engine failed to secure from the bridge.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 April 2018
Resolution: Engine Shutdown has been fixed
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 March 2018 Resolved
Conduct underway drills prior to the start of the season.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 April 2018
Resolution: Completed drills with CG Inspector
Communications › Public Address System › Announcing Station
Issued 23 March 2018 Resolved
Troubleshoot and repair the public address microphone at the operating station.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 5 April 2018
Resolution: Pilot house microphone cable was replaced, operational test sat.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 23 March 2018 Resolved
Conduct an operational test of the engine room heat detectors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 27 April 2018
Resolution: Heat detector tested sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 March 2018 Resolved
Correct life jacket stowage markings to reflect size and quantity.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 5 April 2018
Resolution: Verified forward cabin life jacket stowage locations were appropriately marked with the size and quantity.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 23 March 2018 Resolved
Mark entrances to spaces storing and protected by CO2 IAW regulation.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 5 April 2018
Resolution: Verified CO2 storage and discharge locations were marked IAW regulation.
Documentation › Certificates/Documents › FCC SSL
Issued 23 March 2018 Resolved
Provide a current Radio Station Authorization.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 5 April 2018
Resolution: Verified Radio Station Authorization was renewed and aboard.
Engineering › Non-conventional Propulsion/Steering › Hydraulic Bucket Cylinder (jet)
Issued 5 June 2017 Resolved
Repair STBD side buckets hydraulic system with the blown O-ring directional hydraulic valve. Call for inspection of repairs.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 5 June 2017
Resolution: Renew directional valve, tested sat.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 14 November 2016 Resolved
Flexible nonmetallic hose must be installed with approved end fittings. provide proper hose attachemtnts for the vessel's sewage piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 12 April 2017
Resolution: Allowed by Sector Juneau Determination. Alterations or repairs will be required to be done IAW current regs.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 November 2016 Resolved
Each connection to a conductor shall be made in an enclosure. Make all bilge pumps, floats, and miscellaneous salt water pump wiring connections in an enclosure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 12 April 2017
Resolution: Allowed by Sector Juneau Determination. Alterations or repairs will be required to be done IAW current regs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 November 2016 Resolved
Each conductor shall be held with metal supports not more than 24" apart. Provide supports for the sewage pump power supply conductors in the #3 port void.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 11 May 2017
Resolution: Done, sat.
Lifesaving › Hand Flares › Quantity
Issued 21 April 2016 Resolved
Provide 3 red hand held flares or proper substitution. 46CFR180.68
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 12 May 2016
Navigation › Piloting/Steering › Marine Charts
Issued 21 April 2016 Resolved
Provide adequate and up to date marine charts. 46CFR184.420
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 12 May 2016
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 April 2016 Resolved
Provide adequate and up to date CG Light List. 46CFR184.420
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 12 May 2016
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 April 2016 Resolved
Provide adequate and up to date Tide tables. 46CFR184.420
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 12 May 2016
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 April 2016 Resolved
Provide adequate and up to date current tables. 46CFR184.420
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 12 May 2016
Operations/Management › Drills/Instruction › Abandon Ship
Issued 21 April 2016 Resolved
Provide crew emergency training records. 46CFR185.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 12 May 2016
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 21 April 2016 Resolved
Prove proper operation of 12volt/Emerg lights. 46CFR183.200
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 27 April 2016
Accommodation/Occupational Safety › Ventilation › General
Issued 21 April 2016 Resolved
Prove proper operation of engine room fans. 46CFR182.465
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 27 April 2016
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 21 April 2016 Resolved
Prove proper operation of port engine room fire alarm. 46CFR181.400
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 27 April 2016
Lifesaving › Lifebuoys › Serviceable
Issued 21 April 2016 Resolved
Replace peeled retro tape on aft two ring buoys. 46CFR180.70
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 27 April 2016
Engineering › Steering Gear System › Fastener
Issued 21 April 2016 Resolved
Identify reason for hose clamps on #1port jet & repair if needed. 46CFR182.200
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 12 May 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 21 April 2016 Resolved
Replace wasted B-II extinguisher on stern of vessel. 46CFR181.500
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 27 April 2016
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 21 April 2016 Resolved
Repair coolant/oil leaks on generator. 46CFR182.310
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 12 May 2016
Operations/Management › Drills/Instruction › Abandon Ship
Issued 21 April 2016 Resolved
Conduct emergency drills with crew. 46CFR185.520
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 12 May 2016
Personnel › Certificates/Documents/Licenses › License, Master
Issued 21 April 2016 Resolved
Provide valid CG license for vessel operators.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 12 May 2016

Casualty record · 2

27 June 2002Routine · role: Subject to Marine Inspection · activity 1637853
4 June 2014Routine · role: Involved in a Marine Casualty · activity 4885210
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

KEET (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.