A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Unknown
Issued 12 April 1985
Resolved
MAKE PERMANENT REPAIRS TO PATCH ON ELBOW AREA BY SILVER CARGO PUMP DISCHARGE VALVE.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
MAKE PERMANENT REPAIRS IN WAY OF PATCH ON FOAM LINE BETWEEN STATION 4 AND 5.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
MAKE THE WASTE HEAT BOILER AVAILABLE FOR INTERNAL/EXTERNAL INSPECTION, INSPECTION OF MOUNTINGS, AND HYDRO TEST SAME.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
OPEN MOUNTINGS ON THE AUXILIARY BOILER FOR INSPECTION.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
REPAIR GROUND ON THE 120V, 3 PHASE BUS FOR THE EMERGENCY GENERATOR.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
EFFECT PREMANENT REPAIRS TO THE WASTED AREA ON THE AUXILIARY CONDENSER DISCHARGE HEATER.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
PROVE THE HIGH PRESSURE SHUT DOWN ON THE AUXILIARY BOILER.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
REPAIR AND PROVE MAIN PROPULSION AUTOMATION.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
MAKE PERMANENT REPAIRS TO WASTED AREAS IN WAY OF THE PAINT LOCKER VENT.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
REPAIR OR RENEW HATCH TO ANCHOR WINDLASS ROOM.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
REFASTEN ALL AIR CONTROL LINES TO DECK BRACKETS.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
REPAIR MAIN BALLAST PUMP.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
RENEW MIDSHIP SAFETY VALVE BLOW DOWN PIPE ON THE STEAM SYSTEM.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
RENEW OR REPAIR ENGINE COVERS ON BOTH LIFEBOATS.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
MAKE PERMANENT REPAIRS IN WAY OF TEMPORARY PATCH OF PORT LIFEBOAT.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
REPLACE OR REPAIR VALVE AT THE NO. 12 FIRE STATION.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
REPAIR RED PUMP STEAM STRAINER STUDS.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
REPAIR YELLOW CARGO PUMP DRAIN LINE OF STEAM STRAINER.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
REPLACE AFTER DECK WINCH SAFETY VALVE.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
HYDRO OR MAKE AVAILABLE FOR INTERNAL EXAMINATION THE D.C. HEATER.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
REPAIR AFTER COOLERS ON THE NO. 1 AND 2 AIR COMPRESSORS.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
TEST ALL UNFIRED PRESSURE VESSEL RELIEF VALVES.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
PROVE OVERSPEED TRIPS ON BOTH AUXILIARY BOILER FEED PUMPS.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 April 1985
Resolved
TEST THE AUTOMATION TEST PROCEDURE FOR THE WASTE HEAT BOILER.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 9 February 1985
Resolved
TEST COFFIN STEAM TURBINE FEED WATER PUMPS OVERSPEED TRIPS.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past