Records from 1997 to 2019. Most recent: inspection, 9 May 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
9 May 2019
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6680194
10 January 2017
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6068541
3 June 2016
Damage Survey
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5896226
17 March 2014
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4817533
23 July 2009
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3542302
19 February 2009
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3420248
28 February 2007
COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2879344
27 February 2007
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2878345
26 October 2006
In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2810411
11 May 2005
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2696554
14 January 2004
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1984078
18 December 2003
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1966497
11 December 2003
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1962588
13 November 2003
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1950239
8 November 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 123732
7 November 2001
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1429653
10 August 2001
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1373574
6 February 2001
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1057859
17 September 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1452558
30 July 1999
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1436243
11 December 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 809395
17 November 1998
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1468895
10 September 1998
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1132023
10 November 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 788255
3 July 1997
Hull Examination · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1112525
Construction/Loadline › Hull › Bottom Plating
Issued 3 June 2016
Resolved
Submit repair plan for delaminated FRP IWO shaft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2017
Resolution: Delamination has been repaired.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 June 2016
No resolution recorded
Complete credit drydock and COI inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Certificates/Documents › FCC SSL
Issued 23 July 2009
Resolved
Provide a radio station license for the vessel.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 2 September 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 July 2009
Resolved
Demonstrate proper operation of the anchor light. Vessel restricted to daylight operation only.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 2 September 2009
Fire Fighting › Ventilation Systems › Ducts
Issued 23 July 2009
Resolved
Provide closure devices for each engine room compatment vents.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 2 September 2009
Engineering › Bilge Water Management System
Issued 13 November 2003
Resolved
Install indicator lights for all automatic bilge pumps, or disable automatic operation. 46CFR182.530(3)(c) LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 December 2003
Resolved 5 December 2003
Lifesaving › Lifebuoys
Issued 13 November 2003
Resolved
Provide operating metallic clip for life ring. 46CFR180.7(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2003
Resolved 5 December 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 13 November 2003
Resolved
replace missing items in firsr aid kit IAW 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2003
Resolved 5 December 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 13 November 2003
Resolved
provide drawings and calculations for fixed fire extinguishing system 46 CFR 181.400
5DEC2003: Calculations proved system was to small for space. Owner to install larger system. Extended date till 5FEB2004 LEGACY COMPONENT DESC: Quantity of Gas
Action required: 705 - Other - as specified
Due 5 February 2004
Resolved 18 December 2003
Fire Fighting › Miscellaneous Items
Issued 13 November 2003
Resolved
provide 3 2 1/2 gallon buckets with lanyards, buckets to be marked fire buckets 46CFR 181.610
Action required: 705 - Other - as specified
Due 5 December 2003
Resolved 5 December 2003
Engineering › Bilge Water Management System
Issued 13 November 2003
Resolved
provide hose for hand bilge pump that will reach overboard 187.520 (b)
Action required: 705 - Other - as specified
Due 5 December 2003
Resolved 5 December 2003
Engineering › Bilge Water Management System
Issued 13 November 2003
Resolved
demonstrate high bilge alarms 46 CFR 18270
Action required: 705 - Other - as specified
Due 5 December 2003
Resolved 26 November 2003
Fire Fighting
Issued 7 November 2001
Resolved
BI Fire-extinguisher was not inspected.
Condition: Unknown
Due 7 November 2001
Resolved 18 November 2001
Navigation
Issued 7 November 2001
Resolved
Horn inoperable.
Condition: Unknown
Due 7 November 2001
Resolved 18 November 2001
Navigation
Issued 7 November 2001
Resolved
No charts for area.
Condition: Unknown
Due 7 November 2001
Resolved 18 November 2001
Navigation
Issued 7 November 2001
Resolved
No means of emergency steering.
Condition: Unknown
Due 7 November 2001
Resolved 18 November 2001
Documentation
Issued 17 November 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Navigation
Issued 17 November 1998
Resolved
PROVE EMERGENCY TILLER.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998