Records from 2016 to 2026. Most recent: inspection, 19 May 2026.
Inspection history · 20
19 May 2026
Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8380287
23 September 2025
Plan Review "T" Boat · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8194317
20 February 2025
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8082098
7 August 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7976024
5 September 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7785371
25 July 2023
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7751532
4 May 2022
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7442603
19 November 2021
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7352681
19 November 2021
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7356299
22 July 2021
Administrative Inspection · Internal Structural Exam · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7264439
13 August 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7029987
14 August 2019
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6782520
16 October 2018
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6562094
25 July 2018
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6492227
5 July 2018
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6467706
21 May 2018
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6419930
28 March 2017
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6113119
22 March 2017
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6109728
7 June 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5899876
12 January 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5796114
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 September 2025
Resolved
A fire pump must be capable of both remote operation from the operating station and local operations at the pump. Fire pump is only operable from Engine Room.
46 CFR 181.300(e)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 November 2025
Resolution: Conducted test of fire pump using new install start at operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 September 2025
Resolved
The individual bilge suction lines shall be led to a central control point or manifold. Each line shall be provided with a stop valve at the control point or manifold and in addition shall be provided with a check valve at some accessible point in the bilge line. 02 bilge suction lines are not equipped with stop valves or check valves.
46 CFR 182.25-5(c) old t
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 November 2025
Resolution: New def. entered due to all new install of bilge suctions.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 September 2025
Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. Flame screen serving the STBD fuel vent/gooseneck on vehicle deck is torn.
46 CFR 182.20-35 (d) (OLD - T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 November 2025
Resolution: New flame screen installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 September 2025
Resolved
An adult life jacket must be provided for each person carried on board and each life jacket vessel must be marked in accordance with § 185.604 of this chapter. Vessel had present 73 adult lifejackets and 6 children.
The vessel COI requires 107 adults and 11 children.
46 CFR 180.71 (Old T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 November 2025
Resolution: All lifejackets accounted for.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 September 2025
Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. Fire hydrant located on Port Side of vehicle deck is leaking at valve stem.
46 CFR 181.15-5 (c) (OLD - T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 20 November 2025
Resolution: Ran fire pump and energized port hose and valve, no leak.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 23 September 2025
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. 02 penetrations in FWD Engine Room bulkhead are not watertight.
46 CFR 179.320 (c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 20 November 2025
Resolution: Penetrations have been filled.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 September 2025
Resolved
Except as otherwise provided in this paragraph all unfired pressure vessels shall be Coast Guard approved and installed to the satisfaction of the Officer in Charge, Marine Inspection. Pressure vessel located in Engine Room that serves the vessel's horn and operating station controls contains a placard that is painted over
46 CFR 182.10-5 (d) (OLD - T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 20 November 2025
Resolution: Placard is now clear and legible. All paint removed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 23 September 2025
Resolved
Suitable covers and guards shall be installed in way of all exposed and hazardous places such as gears and machinery. No guards were present on all four main engines or the port generator.
46 CFR 177.35-15
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 20 November 2025
Resolution: Guards are now in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 September 2025
Resolved
Battery chargers must have an ammeter connected in the charging circuit. The battery chargers are installed after 1996 therefore applying with the new T regulations. All three battery chargers did not have ammeter connected.
46 CFR 183.350(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 20 November 2025
Resolution: Ammeter is now attached.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2025
Resolved
Non-conducting mats or gratings shall be provided on deck in front and rear of switchboards. Main switchboard
in Engine Room is missing non-conducting mats.
46 CFR 183.10-15(b) (Old T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 20 November 2025
Resolution: Mats are now present.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 September 2025
Resolved
Piping is an vital system must be composed of ferrous material. Bilge suction and check valves were constructed of plastic in all pickups. Rectify prior to carrying passengers or cargo.
46 CFR 182.710(c)
Action required: 705 - Other - as specified
Resolved 9 June 2026
Resolution: Verfieied metal.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 September 2025
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The markings required by paragraphs (a), (b), and (c) of this section, which may be made by the use of any means and materials which result in durable markings, must be made in clearly legible letters of the Latin alphabet or Arabic or Roman numerals not less than four inches in height. The vessel name on the stern only had "Caribbean" but should be "Caribbean Ferry". Rectify in 30 days.
46 CFR 67.123(a) & (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2025
Resolved 13 May 2026
Resolution: Vessel had name change to BLUE HIGHWAY 1. Name of vessel was marked on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 August 2024
Resolved
Fuel shutoff label was painted over. Re-stencil emergency fuel shutoffs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2024
Resolved 9 October 2024
Resolution: Recieved photos from vessel rep. showing the fuel shutoff labled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 August 2024
Resolved
E/R hatch gasket found damaged. Replace gasket on hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2024
Resolved 9 October 2024
Resolution: Recieved photos from vessel rep. showing a new gasket on the E/R hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 August 2024
Resolved
Port side life ring found wasted. Replace lifering.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2024
Resolved 7 August 2024
Resolution: New lifering provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 September 2023
Resolved
Provide bilge manifold labeling diagram.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2023
Resolved 11 October 2023
Resolution: New bilge diagram posted.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 September 2023
Resolved
Mount deck light on port side cabin house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2023
Resolved 11 October 2023
Resolution: Deck light mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 September 2023
Resolved
Provide 05 child lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2023
Resolved 11 October 2023
Resolution: Life jackets provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 May 2022
Resolved
Prove proper operation of bilge system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2022
Resolution: New bilge pump installed. De-watered all spaces.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 4 May 2022
Resolved
Crop and renew E/R escape hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 2 June 2022
Resolution: New escape hatch installed.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 4 May 2022
Resolved
Remove waste oil from E/R bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2022
Resolution: Oil was removed from E/R bilge.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 August 2020
Resolved
Make permenent repairs to hole in fire main salt water sea suction.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2020
Resolved 2 November 2020
Resolution: Fire/bilge line replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 August 2020
Resolved
Prove proper operation bilge high level alarm in void #1.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2020
Resolved 2 November 2020
Resolution: New bilge alarm installed and tested.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 August 2020
Resolved
Nav. lights do not comply with UL 1104.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 2 November 2020
Resolution: New UL lights installed.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 13 August 2020
Resolved
Repair hole in E/R hatch coming.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 2 November 2020
Resolution: E/R coming repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 August 2020
Resolved
Replace man hole gaskets on steering and center ballast hatch covers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 2 November 2020
Resolution: Man hole gaskets replaced on all deck hatches.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 August 2020
Resolved
Provide cover for electrical outlet in E/R.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 2 November 2020
Resolution: New cover installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 August 2020
Resolved
Provide double hose clamps on vital systems in E/R.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 2 November 2020
Resolution: double hose clamps installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 August 2019
Resolved
Repair stuffing tube and re-wire bow light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2019
Resolved 30 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 August 2019
Resolved
Repair or replace shore tie.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2019
Resolved 30 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2018
Resolved
Main engine seized and eas replaced
Action required: 10 - Deficiency Rectified
Due 27 July 2018
Resolved 27 July 2018
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 21 May 2018
Resolved
Fire extinguisher in pilot house was over due for inspection.
Action required: 10 - Deficiency Rectified
Due 21 May 2018
Resolved 21 May 2018
Resolution: Extinguisher replaced.
Lifesaving › Hand Flares › Expired
Issued 21 May 2018
Resolved
All hand held flares are expired.
Action required: 10 - Deficiency Rectified
Due 21 May 2018
Resolved 21 May 2018
Resolution: New flares were placed onboard during the inspection.
Fire Fighting › Fire Hoses › Condition
Issued 21 May 2018
Resolved
One fire hose had a hole
Action required: 10 - Deficiency Rectified
Due 21 May 2018
Resolved 21 May 2018
Resolution: Hose replaced.
Lifesaving › Inflatable Buoyant Apparatus › Float Free
Issued 21 May 2018
Resolved
Hydrostatic release was expired on the stbd IBA and both the port and stbd painter lines were not secured to the vessel.
Action required: 10 - Deficiency Rectified
Due 21 May 2018
Resolved 21 May 2018
Resolution: Hydrostatic release replaced and IBA properly rigged.
Engineering › Fuel Oil Service System › Valve, Control
Issued 21 May 2018
Resolved
On deck emergency fuel shut off valves needed to be relabled.
Action required: 10 - Deficiency Rectified
Due 21 May 2018
Resolved 21 May 2018
Resolution: Relabel emergency fuel shutoff.
Engineering › Steam System (auxiliary) › Piping
Issued 28 March 2017
Resolved
Package boiler exhaust has a large hole located at the elbow of the exhaust as it turns up and out of the engine room
Due 31 May 2017
Resolved 17 May 2017
Engineering › Steam System (auxiliary) › Piping
Issued 28 March 2017
Resolved
Return line for package boiler is wasted adjacent to the boiler
Due 31 May 2017
Resolved 17 May 2017