A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting › Fire Bucket › Availability
Issued 29 February 2008
Resolved
Replace 5 gallon fire buckets with 2.5 gallon buckets.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 3 March 2008
Resolution: Provided 2.5 Gallon fire buckets.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 29 February 2008
Resolved
Place Fire Extinguisher in forward compartment in mounting bracket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 3 March 2008
Resolution: Fire extinguisher remounted in new fire extinguisher bracket.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 29 February 2008
Resolved
Replace all of vessels flares. Replace 3 orange smoke signals.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 3 March 2008
Resolution: New replacement flairs and orange smoke signals were noted onboard.
Stability › Watertight Integrity › General
Issued 29 February 2008
Resolved
Repair Watertight Bulkhead through fitting between Head and Engineroom.
Due 3 April 2008
Resolved 3 April 2008
Resolution: Repairs were made to through fitting between head and engine room.
Stability › Watertight Integrity › General
Issued 29 February 2008
Resolved
Repair aft hatch to allow for easy operation and attach capturing device to both aft hatches.
Due 3 April 2008
Resolved 10 March 2008
Resolution: Repaired Aft Hatch and attached recapturing device (chain) to both hatches.
Stability › Watertight Integrity › General
Issued 29 February 2008
Resolved
Provide Gasket to forward hatch.
Due 3 April 2008
Resolved 10 March 2008
Resolution: Gasket provided on forward hatch
Stability › Weathertight Integrity › General
Issued 29 February 2008
Resolved
Repair holes in main deck (where table was formally mounted).
Due 3 April 2008
Resolved 3 April 2008
Resolution: Bolts were inserted where holes were located in deck.
Engineering › Bilge Water Management System › Pump
Issued 29 February 2008
Resolved
Repair aft bilge high level alarm and securely fasten.
Due 3 April 2008
Resolved 10 March 2008
Resolution: Reattached Bilge alarm and ensured proper operation.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 29 February 2008
Resolved
Repair Starboard side fuel tank valve.
Due 3 April 2008
Resolved 10 March 2008
Resolution: Fuel valve was repaired on starboard side.
Engineering › Steering Gear System › Rudder
Issued 29 February 2008
Resolved
Provide Means of Auxiliary Steering.
Due 3 April 2008
Resolved 10 March 2008
Resolution: New hardward was added to rudder post to enable the use of a T-bar for auxilary steering.
Engineering › Bilge Water Management System › Hose
Issued 29 February 2008
Resolved
Double Clamp Rubber hose section of bilge discharge starboard side.
Due 3 April 2008
Resolved 10 March 2008
Resolution: Additional clamps added to bilge discharge hose starboard side.
Electrical › Electric Supply System (service) › Cable
Issued 29 February 2008
Resolved
Remove all dead end cables in engine room.
Due 3 April 2008
Resolved 10 March 2008
Resolution: All dead end and unused cables were removed.
Electrical › Electric Supply System (service) › Cable
Issued 29 February 2008
Resolved
Remove all plastic cable supports and replace with metal.
Due 3 April 2008
Resolved 10 March 2008
Resolution: All metal cables used for support have been replaced by metal supports.
Fire Fighting › Combustible Materials › Insulation
Issued 29 February 2008
Resolved
Replace all insulation on turbos in engineroom prior to carrying passengers.
Due 3 April 2008
Resolved 10 March 2008
Resolution: All insulation on turbos was replaced.
Fire Fighting › Combustible Materials › Insulation
Issued 29 February 2008
Resolved
Replace all oil soaked insulation in engine overhead and walls.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2008
Resolution: All insullation soaked by oil was replaced.
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 29 February 2008
Resolved
Identify and repair source of oil leak in engineroom.
Due 3 April 2008
Resolved 10 March 2008
Resolution: Oil leak was repaired.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 February 2008
Resolved
Tighten battery connectors.
Due 3 April 2008
Resolved 10 March 2008
Resolution: Battery connectors were tightened.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 29 February 2008
Resolved
Pleace vessel name on all lifejackets, lifefloats and paddles, transom and bow.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2008
Resolution: Vessel Name was properly marked on vessel, lifejackets and paddles.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 29 February 2008
Resolved
Place fire extinguisher in forward compartment in proper bracket.
Due 3 April 2008
Resolved 10 March 2008
Resolution: Bracket in forward compartment was replaced and properly installed.
Construction/Loadline › Hull › Longitudinal Frame
Issued 4 September 2007
Resolved
Properly repair all cracked framing welds to the satisfaction of attending marine instpector.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2007
Resolution: All cracks repaired and additional stiffeners put in place in an effort to stop problem.
Construction/Loadline › Hull › Stiffener
Issued 4 September 2007
Resolved
Allow for satisfactory inspection of longitudinal stiffeners being added to vessel IVO aft fuel tank/lazerette area.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2007
Resolution: Completed satisfactory inspection of installation.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 September 2007
Resolved
Demonstrate satisfactory MOB drill.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2007
Resolution: Conducted Satisfactory MOB drill.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 13 June 2007
Resolved
Replace expired EPIRB hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2007
Resolution: hydrostatic release replaced.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 13 June 2007
Resolved
prove proper operation of water light for buoyant apparatus
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2007
Resolution: Life float battery replaced and light operational
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 13 June 2007
Resolved
Provide 01 child lifejackets
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2007
Resolution: 01 child lifejacket purchase and on board.
Engineering › Fuel Oil Service System › Filter
Issued 13 June 2007
Resolved
Provide flamecup for fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2007
Resolution: Flame cup provided.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 June 2007
Resolved
Provide cover for battery box.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2007
Resolution: Cover provided for battery box.
Navigation › Piloting/Steering › Magnetic Compass
Issued 13 June 2007
Resolved
Provide light for magnetic compass.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2007
Resolution: Light bulb replaced.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 13 June 2007
Resolved
Provide lid for trash can.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2007
Resolution: Lid provided.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 June 2007
Resolved
Remove excessive oil from bilges.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2007
Resolution: Oil removed and bilges scrubbed clean.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 8 August 2006
Resolved
Ensure bilge is clean and excess oil is removed.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2006
Resolution: Bilge was cleaned and clear of oil
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 8 August 2006
Resolved
Repair crack in stbd. side fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2006
Resolution: New starboard fuel tank installed, pressure tested sat
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 3 May 2006
Resolved
Remove oil from bilge
Condition: Unknown
Due 17 May 2006
Resolved 4 May 2006
Resolution: Sufficiently removed oil
Electrical › Lighting (service) › Lighting Fixture
Issued 3 May 2006
Resolved
Remove inoperable light fixture from engine room.
Condition: Improper/Lack of Maintenance
Due 17 May 2006
Resolved 4 May 2006
Resolution: Removed light and wiring.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 May 2006
Resolved
Provide metal support brackets every 24" for engine room wiring
Condition: Improper Installation
Due 17 May 2006
Resolved 4 May 2006
Resolution: Installed new metal brackets.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 3 May 2006
Resolved
Provide (1) additional childs pfd.
Condition: Unknown
Due 17 May 2006
Resolved 4 May 2006
Resolution: Purchased new pfd.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 21 July 2005
Resolved
Replace cutlass bearings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 July 2005
Resolution: Installed new bearings.
Engineering › Steering Gear System › Rudder
Issued 21 July 2005
Resolved
repair rudder support.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 July 2005
Resolution: installed new rudder supports.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 July 2005
Resolved
Reseal exhaust through hole.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 July 2005
Resolution: Sealed through hole with plating and foam.
Stability › Watertight Integrity › General
Issued 21 July 2005
Resolved
Seal all watertight bulkheads.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 July 2005
Resolution: Sealed bulkheads holes w/ foam, placed valves on water through holes.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 21 July 2005
Resolved
Provide shaft alignment report.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 July 2005
Resolution: Provided report.
Engineering › Bilge Water Management System › Pump
Issued 21 July 2005
Resolved
Provide proper operation of aft bilge pump.
Condition: Improper Installation
Due 10 August 2005
Resolved 16 August 2005
Resolution: Installed new bilge pump
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 July 2005
Resolved
Enclose all exposed wiring in fully encapsulated wire connectors.
Condition: Improper Installation
Due 10 August 2005
Resolved 16 August 2005
Resolution: Enclosed all splices and loose ends in proper connectors.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 July 2005
Resolved
Secure engine room wiring with metal brackets every 18 inches.
Condition: Improper Installation
Due 10 August 2005
Resolved 16 August 2005
Resolution: Installed proper brackets
Operations/Management › Pollution › Retention of Oily Mixture
Issued 21 July 2005
Resolved
Remove Oil from bilge
Condition: Unknown
Due 10 August 2005
Resolved 16 August 2005
Resolution: Removed
Operations/Management › Equipment Service/Testing › EPIRB
Issued 21 July 2005
Resolved
Properly mount EPIRB
Condition: Improper Installation
Due 10 August 2005
Resolved 16 August 2005
Resolution: New Mount
Engineering › Bilge Water Management System › Piping
Issued 21 July 2005
Resolved
Replace all bilge system with metallic piping.
Condition: Improper Installation
Due 10 August 2005
Resolved 16 August 2005
Resolution: Installed new piping.
Documentation › Markings/Placards › Warning Signs
Issued 21 July 2005
Resolved
Stencil marking on flare box.
Condition: Improper Installation
Due 17 August 2005
Resolved 16 August 2005
Resolution: Properly labeled.
Lifesaving › Rigid Liferafts › Weak Link
Issued 21 July 2005
Resolved
Weak link expired.
Condition: Improper/Lack of Maintenance
Due 17 August 2005
Resolved 16 August 2005
Resolution: New weak link installed.
Documentation › Markings/Placards › Lifejacket Placard
Issued 21 July 2005
Resolved
Provide donning placards for both types of pfd's onboard.
Condition: Improper Installation
Due 17 August 2005
Resolved 16 August 2005
Resolution: Installed seperate donning placards for both types of pfd''s onboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 18 August 2004
Resolved
B-II brackets rusted beyond repair.
Condition: Unknown
Due 1 September 2004
Resolved 19 August 2004
Resolution: Brackets replaced with new.
Fire Fighting › Fire Bucket › Availability
Issued 18 August 2004
Resolved
Missing a third bucket.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2004
Resolution: Third bucket added.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 18 August 2004
Resolved
Open holes in E/R fwd bulkbead.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2004
Resolution: Holes filled with approved fire stop.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 18 August 2004
Resolved
Manual vent closures frozen in open position.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2004
Resolution: Replaced hardware and made vent closures work as intended.
Lifesaving › Hand Flares › Quantity
Issued 18 August 2004
Resolved
Two red flares missing.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2004
Resolution: Two red flares added.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 August 2004
Resolved
Lifeline worn.
Condition: Unknown
Due 1 September 2004
Resolved 19 August 2004
Resolution: Line replaced.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 19 May 2003
Resolved
Engine room fixed fire extinguishing system passed inspection due date - Have inspected.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2003
Resolution: Fire boy inspected [name withheld] Fire & Safety.
Stability › Watertight Integrity
Issued 19 May 2003
Resolved
Seal all watertight bulkhead penetrations.
Due 2 June 2003
Resolved 22 May 2003
Resolution: Corrected
Engineering
Issued 19 May 2003
Resolved
Replace port side raw water suction valve.
Due 2 June 2003
Resolved 22 May 2003
Resolution: Gate valve replaced with ball valve.
Engineering › Fuel Oil Storage/Transfer System
Issued 18 June 2002
Resolved
Provide 30X30 flame screen for both port & starboard fuel vents. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper Installation
Due 28 June 2002
Resolved 19 May 2003
Resolution: Screens provided both port and stbd.
Navigation › Emergency Steering
Issued 18 June 2002
Resolved
Prove proper operation of emergency steering system
Due 28 June 2002
Resolved 18 June 2002
Documentation › Certificates/Documents
Issued 18 June 2002
Resolved
Provide proof of valid COD LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 28 June 2002
Resolved 19 May 2003
Construction/Loadline › Structures
Issued 3 April 2001
Resolved
RENEW WATER TIGHT BULKHEAD HATCH GASKET LOCATED AFT OF ENGINE ROOM. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Unknown
Due 28 May 2001
Resolved 14 May 2001
Navigation › Emergency Steering
Issued 3 April 2001
Resolved
PROVE PROPER OPERATION OF EMERGENCY TILLER ARM.
Condition: Unknown
Due 28 May 2001
Resolved 14 May 2001
Lifesaving › Lifejacket/PFD (Type I)
Issued 3 April 2001
Resolved
PROPERLY STENCIL STOWAGE COMPARTMENT FOR CHILD/ ADULT PFDS. LEGACY COMPONENT DESC: Marking
Condition: Unknown
Due 3 April 2001
Resolved 14 May 2001
Construction/Loadline › Structures
Issued 3 April 2001
Resolved
Renew 3" cracked weld located starboard side on stern dive platform. LEGACY COMPONENT DESC: Superstructure
Condition: Unknown
Due 28 May 2001
Resolved 14 May 2001
Engineering › Bilge Water Management System
Issued 3 April 2001
Resolved
Install UL approved bilge alarms with audible and visual indicators.
Due 28 May 2001
Resolved 14 May 2001
Construction/Loadline › Penetrations
Issued 3 April 2001
Resolved
Properly make hydraulic lines penetrations in stern watertight.
Condition: Unknown
Due 28 May 2001
Resolved 14 May 2001
Construction/Loadline › Structures
Issued 3 April 2001
Resolved
Prove collision bulkhead is watertight. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Due 28 May 2001
Resolved 14 May 2001